ENV 50269:1997
(Main)Assessment and representative testing of high-voltage machines
Assessment and representative testing of high-voltage machines
Corrigendum to ENV issued March 1997 * Superseded by EN 60079-7:2003
Auswahl und repräsentative Prüfung von Hochspannungsmaschinen
Assesment and representative testing of high-voltage machines
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST ENV 50269:1998
01-april-1998
Assesment and representative testing of high-voltage machines
Assessment and representative testing of high-voltage machines
Auswahl und repräsentative Prüfung von Hochspannungsmaschinen
Ta slovenski standard je istoveten z: ENV 50269:1997
ICS:
29.020 Elektrotehnika na splošno Electrical engineering in
general
SIST ENV 50269:1998 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST ENV 50269:1998
---------------------- Page: 2 ----------------------
S
...
This May Also Interest You
This document provides specific emission and immunity requirements, tests and performance criteria for residual current-operated protective devices (RCDs), for household and similar use, for rated voltages not exceeding 440 V. Household and similar use corresponds to the description given in the generic standard IEC 61000-6-1 for residential, commercial, and light-industrial electromagnetic environments. This document is intended to be referred to by RCD product standards and is not intended to be used as a standalone document. Residual current-operated protective devices are: - Residual current operated circuit-breakers without integral overcurrent protection for household and similar use (RCCBs) covered by IEC 61008 series and IEC 62423; - Residual current operated circuit-breakers with integral overcurrent protection for household and similar use (RCBOs) covered by IEC 61009 series and IEC 62423; - Residual current devices with or without overcurrent protection for socket-outlets (SRCDs) covered by IEC 62640; - Portable residual current devices without integral overcurrent protection (PRCDs) covered by IEC 61540; - Devices with an RCD functionality for household and similar use according product standards following the group safety publications for general safety requirements for RCDs, IEC 60755. This edition applies if it is referred to as a dated reference in the relevant product standard. This document is also intended to be used as a guideline in the preparation of EMC requirements and tests for other product standards under the scope of SC 23E. It also specifies generic performance criteria intended to be transformed into specific performance criteria by the relevant product standard. Note: Examples of other product standards under the scope of SC 23E are: - IEC 62020-1 "Electrical accessories - Residual current monitors (RCMs) – Part 1: RCMs for household and similar uses"; - IEC 62606 "General requirements for arc fault detection devices"; - IEC 63024 "Requirements for automatic reclosing devices (ARDs) for circuit breakers, RCBOs-RCCBs for household and similar uses"; - IEC 63052 "Power frequency overvoltage protective devices (POPs) for household and similar applications"; - IEC 62752 "In-cable control and protection device for mode 2 charging of electric road vehicles (IC-CPD)"; - IEC 62955 "Residual direct current detecting device (RDC-DD) to be used for mode 3 charging of electric vehicles".
- Draft15 pagesEnglish languagesale 10% offe-Library read for×1 day
This part of IEC 62561 specifies the requirements and tests for devices intended to count the number of lightning strikes based on the current flowing in a conductor. This conductor may be part of a lightning protection system (LPS) or connected to an SPD installation or other conductors, which are not intended to conduct a significant portion of lightning currents. LSCs for use in hazardous atmospheres, extra requirements for the components may be necessary to be taken. NOTE In CENELEC countries, testing requirements of components for explosive atmosphere are specified in CLC/TS 50703-2.
- Standard28 pagesEnglish languagesale 10% offe-Library read for×1 day
- 22-Jun-2023
- 29.020
- 91.120.40
- CLC/TC 81X
IEC 62561-1:2023 is available as IEC 62561-1:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62561-1:2023 specifies the requirements and tests for metallic connection components that form part of a lightning protection system (LPS). Typically, these can be connectors, clamps, bonding and bridging components, expansion pieces and test joints. This third edition cancels and replaces the second edition published in 2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) definitions of connection types mentioned in the scope have been added; b) location classification has been expanded in detail; c) the document has been updated in line with the new edition of ISO 22479:2019 on humid sulphurous atmosphere treatment; d) a new normative Annex E for reduced test procedures has been introduced.
- Standard32 pagesEnglish languagesale 10% offe-Library read for×1 day
- 11-May-2023
- 29.020
- 91.120.40
- CLC/TC 81X
IEC 61547:2020 is available as IEC 61547:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61547:2020 which deals with electromagnetic immunity requirements, applies to lighting equipment which is within the scope of IEC technical committee 34, including apparatus such as lamps, luminaires, and modules. This third edition cancels and replaces the second edition, published in 2009. This edition constitutes a technical revision This edition includes the following significant technical changes with respect to the previous edition: - extension of scope with end-user replaceable modules and the combination of end-user replaceable module and independent auxiliary; - clarification of module testing in a host system; - increased ESD and surge test levels for road and street lighting equipment; - the introduction of ESD testing under normal operation and handling conditions; - removal of line to ground surge test for self-ballasted lamps ≤ 25 W.
- Standard24 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 60216-5:2022 specifies the experimental and calculation procedures to be used for deriving the relative temperature index of a material from experimental data obtained in accordance with the instructions of IEC 60216-1 and IEC 60216-2. The calculation procedures are supplementary to those of IEC 60216-3. Guidance is also given for assessment of thermal ageing after a single fixed time and temperature, without extrapolation. This edition includes the following significant technical changes with respect to the previous edition: Annex C “Computer program” has been completely reworked; in 3.1, the terms “ATE” and “RTE” were replaced by “ATI” and “RTI” to emphasize their reference to an electrical insulating material (EIM). This standard is to be read in conjunction with IEC 60216-1:2013, IEC 60216-2:2005 and IEC 60216-3:2021.
- Standard32 pagesEnglish languagesale 10% offe-Library read for×1 day
- 22-Dec-2022
- 19.020
- 29.020
- 29.035.01
- CLC/SR 112
1.1 Application This document specifies the main characteristics of the voltage at a network user's supply terminals in public low voltage, medium, high, and extra-high voltage AC electricity networks under normal operating conditions. This document specifies the limits or values within which the voltage characteristics can be expected to remain at any supply terminal in public European electricity networks, only. Industrial networks are excluded from the scope of EN 50160. NOTE 1 If non-public networks (e.g. residential quarters, energy communities, office centres, shopping centres) have similar end-users as public networks, it is strongly advised to apply the same requirements as for public networks. This document does not apply under abnormal operating conditions, including the following: a) a temporary supply arrangement to keep network users supplied during conditions arising as a result of a fault, maintenance and construction work, or to minimize the extent and duration of a loss of supply; b) in the case of non-compliance of a network user's installation or equipment with the relevant standards or with the technical requirements for connection, established either by the public authorities or the network operator, including the limits for the emission of conducted disturbances; NOTE 2 A network user’s installation can include load and generation. c) in exceptional situations, in particular: 1) exceptional weather conditions and other natural disasters; 2) third party interference; 3) acts by public authorities, 4) industrial actions (subject to legal requirements); 5) force majeure; 6) power shortages resulting from external events. The voltage characteristics given in this document refer to conducted disturbances in public electric power networks. They are not intended to be used as electromagnetic compatibility (EMC) levels or product emission limits. Power quality is related to EMC in several ways – especially because compliance with power quality requirements depends on the control of cumulative effect of electromagnetic emissions from all/multiple equipment and/or installations. Therefore, the voltage characteristics given in this document gives guidance for specifying requirements in equipment product standards and in installation standards. NOTE 3 The performance of equipment might be impaired if it is subjected to supply conditions which are not specified in the equipment product standard. NOTE 4 This document can be superseded in total or in part by the terms of a contract between the individual network user and the network operator. The sharing of complaint management and problem mitigation costs between the involved parties is outside the scope of EN 50160. Measurement methods to be applied in this document are described in EN 61000-4-30. [...]
- Standard53 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 60364-5-54:2011 addresses the earthing arrangements and protective conductors including protective bonding conductors in order to satisfy the safety of the electrical installation. This third edition cancels and replaces the second edition, published in 2002, and constitutes a technical revision. The main changes with respect to the previous edition are listed below: - clarification of the definition of protective conductor; - improved specification of mechanical characteristics of the earth electrode; - introduction of earth electrode for protection against electric shock and lighting protection; - annexes describing concrete-embedded foundation earth electrodes and soil-embedded earth electrode. IEC 60364-5-54:2011 has the status of a basic safety publication in accordance with IEC Guide 104. This document also includes requirements regarding earthing and equipotential bonding for information and communication technology (ICT) with the aim of: - reducing the risk of electrical hazards for correct operation of these devices and the information and communication technology wiring; - providing the telecommunication systems with a reliable signal reference plane that can improve resistance to electromagnetic interference (EMI) by reference to ISO/IEC 30129. NOTE Examples of information and communication technology (ICT) include: - DC supply networks (and systems) for supplying power to ICT equipment within a building; - star-shaped private automatic branch exchanges (PABX) or their equipment; - local area (communication) networks (LANs); - fire and intruder alarms communication systems; - building automation systems, e.g. direct digital control systems; - systems for computer-aided manufacturing (CAM) and other computer-aided services; - broadcast and communication technology.
- Amendment4 pagesEnglish languagesale 10% offe-Library read for×1 day
This part of IEC 61340 describes test methods for measuring the rate of dissipation of static charge of insulating and static materials and products. It includes a generic description of test methods and detailed test procedures for specific applications. The two test methods for measuring charge decay time, one using corona charging and one using a charged metal plate are different and might not give equivalent results. Nevertheless, each method has a range of applications for which it is best suited. The corona charging method is suitable for evaluating the ability of materials, for example textiles, packaging, etc., to dissipate charge from their own surfaces. The charged metal plate method is suitable for evaluating the ability of materials and objects such as gloves, finger cots, hand tools, etc. to dissipate charge from conductive objects placed on or in contact with them. The charged plate method might not be suitable for evaluating the ability of materials to dissipate charge from their own surfaces. In addition to its general application, this horizontal standard is also intended for use by technical committees in the preparation of standards in accordance with the principles laid down in IEC Guide 108. One of the responsibilities of a technical committee is, wherever applicable, to make use of horizontal standards in the preparation of its publications. The contents of this horizontal standard shall not apply unless specifically referred to or included in the relevant publications.
- Amendment11 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft8 pagesEnglish languagesale 10% offe-Library read for×1 day
- 11-Aug-2022
- 17.220.99
- 29.020
- CLC/SR 101
CLC/TC 34 took decision to unlink project from LVD
- Amendment9 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft4 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies a marking — of electrical and electronic equipment (EEE) with a view to minimizing the disposal of waste EEE (WEEE) as unsorted waste and to facilitating its separate collection. NOTE 1 This is in accordance with Article 14(4) of Directive 2012/19/EU (WEEE, recast) — that serves to clearly identify the producer of the equipment and — that the equipment has been put on the market after 13 August 2005. NOTE 2 This is in accordance with Articles 12(3) and 15(2) of Directive 2012/19/EU (WEEE, recast) — that applies to categories of electrical and electronic equipment subject to WEEE collection, treatment, recovery and environmentally sound disposal as defined by European and national regulations, provided the equipment concerned is not part of another type of equipment that does not fall within the scope of above mentioned regulations. NOTE 3 This is in accordance with Article 2 and Annexes I – IV of Directive 2012/19/EU (WEEE, recast) [1] The definition of a technical carrier medium for machine based identifying the producer, such as a barcode, electronic data medium or microchip, is not covered by this document.
- Standard10 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft10 pagesEnglish languagesale 10% offe-Library read for×1 day
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.