Coaxial cables - Part 2-5: Sectional specification for cables used in cabled distribution networks - Outdoor drop cables for systems operating at 5 MHz - 3 000 MHz

This European Standard relates to EN 50117-1 and should be read in conjunction with this generic specification. This specification applies to outdoor drop cables for use in cabled distribution systems operating at temperature between 40 °C and +70 °C 1) and at frequencies between 5 MHz and 3 000 MHz and complying with the requirements of EN 50083. The purpose of this European Standard is to specify the applicable test methods and requirements for the electrical, mechanical, environmental and fire performance of the cables

Koaxialkabel - Teil 2-5: Rahmenspezifikation für Kabel für Kabelverteilanlagen - Außenkabel im Bereich von 5 MHz - 3 000 MHz

Câbles coaxiaux - Partie 2-5: Spécification intermédiaire pour câbles utilisés dans les réseaux de distribution par câbles - Câbles de raccordement à usage extérieur pour les systèmes fonctionnant à 5 MHz - 3 000 MHz

Koaksialni kabli – 2-5. del: Področna specifikacija za kable v kabelskih razdelilnih omrežjih – Zunanji priključni kabli za sisteme, ki delujejo v območju 5 MHz do 3.000 MHz

Ta evropski standard je povezan s standardom EN 50117-1 in ga je treba brati skupaj s to rodovno specifikacijo. Ta specifikacija velja za zunanje priključne kable v kabelskih razdelilnih sistemih, ki delujejo pri temperaturi med –40 °C in +70 °C 1) in pri frekvencah med 5 MHz in 3 000 MHz ter ustrezajo zahtevam standarda EN 50083. Namen tega evropskega standarda je določiti veljavne preskusne metode in zahteve za električne, mehanske, okoljske in požarne lastnosti kablov.

General Information

Status
Withdrawn
Publication Date
04-Nov-2004
Withdrawal Date
31-Aug-2007
Drafting Committee
Parallel Committee
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
29-Mar-2022
Completion Date
29-Mar-2022

Relations

Buy Standard

Standard
EN 50117-2-5:2005
English language
12 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI SIST EN 50117-2-5:2005

STANDARD
november 2005
Koaksialni kabli – 2-5. del: Področna specifikacija za kable v kabelskih
razdelilnih omrežjih – Zunanji priključni kabli za sisteme, ki delujejo v
območju 5 MHz do 3.000 MHz
Coaxial cables - Part 2-5: Sectional specification for cables used in cabled
distribution networks - Outdoor drop cables for systems operating at 5 MHz - 3 000
MHz
ICS 33.120.10 Referenčna številka
©  Standard je založil in izdal Slovenski inštitut za standardizacijo. Razmnoževanje ali kopiranje celote ali delov tega dokumenta ni dovoljeno

EUROPEAN STANDARD EN 50117-2-5
NORME EUROPÉENNE
EUROPÄISCHE NORM November 2004

ICS 33.120.10
English version
Coaxial cables
Part 2-5: Sectional specification for cables
used in cabled distribution networks –
Outdoor drop cables for systems operating at 5 MHz - 3 000 MHz

Câbles coaxiaux Koaxialkabel
Partie 2-5: Spécification intermédiaire Teil 2-5: Rahmenspezifikation für Kabel
pour les câbles utilisés dans les réseaux für Kabelverteilanlagen –
de distribution câblés – Aussenkabel im Bereich
Câbles de raccordement von 5 MHz - 3 000 MHz
à usage extérieur pour des systèmes
fonctionnant à 5 MHz - 3 000 MHz

This European Standard was approved by CENELEC on 2004-09-01. CENELEC members are bound to
comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and
notified to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden,
Switzerland and United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels

© 2004 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.

Ref. No. EN 50117-2-5:2004 E
Foreword
This European Standard was prepared by SC 46XA, Coaxial cables, of Technical Committee CENELEC
TC 46X, Communication cables.
The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 50117-2-5
on 2004-09-01.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2005-09-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2007-09-01
__________
– 3 – EN 50117-2-5:2004
Contents
1 Scope . 4
2 Normative references . 4
3 Definitions. 4
4 Requirements for cable construction. 5
4.1 General . 5
4.2 Inner conductor . 5
4.3 Dielectric . 5
4.4 Outer conductor or screen . 5
4.5 Filling compounds. 5
4.6 Moisture barriers . 5
4.7 Wrapping layers . 5
4.8 Sheath. 5
4.9 Metallic protection . 6
4.10 Cable integral suspension strand (Messenger wire). 6
4.11 Oversheath. 6
4.12 Fauna proofing . 6
4.13 Chemical and/or environmental proofing . 6
4.14 Cable identification . 6
4.14.1 Sheath marking . 6
4.14.2 Labelling. 6
5 Tests for completed cables . 7
5.1 Electrical tests . 7
5.1.1 Low-frequency and D.C. electrical measurements . 7
5.1.2 High-frequency electrical and transmission measurements . 7
5.2 Mechanical tests. 9
5.3 Environmental tests . 11
5.4 Fire performance test methods . 12

Table 1 – Low-frequency and D.C. electrical measurements . 7
Table 2 – High-frequency electrical and transmission measurements. 7
Table 3 – Mechanical tests. 9
Table 4 – Environmental tests .11
Table 5 – Fire performance test methods . 12

1 Scope
This European Standard relates to EN 50117-1 and should be read in conjunction with this generic
specification. This specification applies to outdoor drop cables for use in cabled distribution systems
1)
operating at temperature between -40 °C and +70 °C and at frequencies between 5 MHz and
3 000 MHz and complying with the requirements of EN 50083.
The purpose of this European Standard is to specify the applicable test methods and requirements for the
electrical, mechanical, environmental and fire performance of the cables.
2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition of the
referenced document (including any amendments) applies.
EN 50083 series Cable networks for television signals, sound signals and interactive services
EN 50117-1 Coaxial cables – Part 1: Generic specification
EN 50289-1-6 Communication cables – Specifications for test methods – Part 1-6: Electrical test
methods – Electromagnetic performance
EN 50289-3-9 Communication cables – Specifications for test methods – Part 3-9: Mechanical
test methods – Bending tests
2)
EN 50290-1-2 Communication cables – Part 1-2: Definitions
EN 50290-2-23 Communication cables – Part 2-23: Common design rules and construction –
PE insulation
EN 50290-2-24 Communication cables – Part 2-24: Common design rules and construction –
PE sheathing
EN 50290-2-25 Communication cables – Part 2-25: Common design rules and construction –
Polypropylene insulation compounds
EN 50290-2-27 Communication cables – Part 2-27: Common design rules and construction –
Halogen free flame retardant thermoplastic sheathing compounds
EN 50290-4-1 Communication cables – Part 4-1: General considerations for the use of cables –
Environmental conditions and safety aspects
EN 62153-1-1 Metallic telecommunication cable test methods – Part 1-1: Electrical –
Measurement of the pulse/step return loss in the frequency domain using the
Inverse Discrete Fourier Transformation (IDFT) (IEC 62153-1-1)
2)
Coaxial communication cables – Part 1-115: Electrical test methods – Test for
IEC 61196-1-115
pulse return loss (regularity of impedance)
3 Definitions
For the purposes of this European Standard, the definitions of EN 50290-1-2 and EN 50117-1 apply.

1)
This value is valid for applications without ampacity only.
2)
At draft stage.
– 5 – EN 50117-2-5:2004
4 Requirements for cable construction
4.1 General
Designing the cable, consideration should be paid to the maximum admissible current stated in the detail
specification. It is assumed that the raise if temperature of the inner conductor when submitted to the
maximum current under nominal ambient conditions does not affect the mechanical and electrical
properties of the cable (details are under study).
4.2 Inner conductor
The conductor shall meet the requirements of Subclause 4.2 of EN 50117-1, and shall be solid or tube.
Individual wires can be plain or metal coated. Dimensions shall be in accordance with the detailed
specification.
There shall be no joint made subsequent to the last drawing operation.
4.3 Dielectric
The dielectric material(s) shall be in accordance with Subclause 4.3 of EN 50117-1 and shall consist of
polyolefin materials, with EN 50290-2-23 (polyethylene), EN 50290-2-25 (polypropylene) or any relevant
part of EN 50290-2-XX. Dimensions shall be in accordance with the detail specification.
Unless otherwise specified, the nominal diameter over the dielectric should be one of the preferred values,
namely 2,9 mm, 3,7 mm, 4,8 mm and 7,2 mm.
4.4 Outer conductor or screen
The construction and material of the outer conductor and/or screen shall be meet the requirements of
clause Subclause 4.4, items b), c), f) or g) of EN 50117-1. Where option b) is used, a double braid layer is
required.
For braid constructions or helically wound wires, the braid angle shall be between 15° and 45°. The
coverage factor shall be greater than or equal to 65 %, or, when the cable is provided with a metal foil,
greater than or equal to 25 %. These values are also valid for cables with two bi-directional layers of
helically wound wires.
Dimensions shall be in accordance with the detailed specification.
4.5 Filling compounds
Not applicable
4.6 Moisture barriers
Not applicable
4.7 Wrapping layers
Not applicable
4.8 Sheath
Sheath material(s) shall meet the requirements of EN 50290-2-24 for PE sheaths or EN 50290-2-27 for
halogen free flame retardant materials.

Sheaths of cables used in aerial or external applications shall meet the requirement of the UV resistance
test.
The sheath shall also meet the requirements of Subclause 4.8 of EN 50117-1.
Dimensions shall be in accordance with the detailed specification.
4.9 Metallic protection
Not applicable
4.10 Cable integral suspension strand (Messenger wire)
When applicable messenger wires shall be in accordance with Subclause 4.10 of EN 50117-1.
When applicable messenger wires shall meet the requirements of the relevant detail specification.
4.11 Oversheath
Not applicable
4.12 Fauna proofing
Not applicable
4.13 Chemical and/or environmental proofing
Not applicable
4.14 Cable identification
Cable identification shall be in accordance with Subclause 4.14 of EN 50117-1.
4.14.1 Sheath marking
Sheath marking shall be achieved as a non-degradable print containing the following minimum
information:
– designation of the cable;
– attenuation value (in dB/100 m at 800 MHz, rounded);
– screening class;
– Euro-class;
– name of supplier.
EXAMPLE EN 50117-2-5 21 < XXX > Class B Euro-class C < YYY >
4.14.2 Labelling
Unless otherwise specified in the detail specification drums or coils shall be provided with a label with a
non-degradable print containing the following minimum information:
– designation of the cable;
– attenuation value (in dB/100 m at 800 MHz, rounded);
– screening class;
– Euro-class;
– 7 – EN 50117-2-5:2004
– name of supplier;
– batch part number;
– length of cable.
EXAMPLE EN 50117-2-5 21 < XXX > Class B Euro-class C < YYY > 03/04 543m
5 Tests for completed cables
When tested in accordance with the requirements of EN 50117-1, the requirements given below shall
apply.
5.1 Electrical tests
5.1.1 Low-frequency and D.C. electrical measurements
Table 1 – Low-frequency and D.C. electrical measurements
EN 50117-1 Parameter Requirements/Remarks
Subclause n°
5.1.1.1 Conductor resistance Applicable, value in accordance with the detail specification
5.1.1.2 Dielectric strength 2 kV D.C. or 1,5 kV A.C. for 1 min
5.1.1.3 Insulation resistance
≥ 10 MΩ x km
5.1.1.4 Mutual capacitance When required, in accordance with the detail specification
5.1.1.5 Voltage test of sheath 2,5 kV A.C. or 3,75 kV D.C., unless otherwise specified in the
relevant detail specification.
a
Test in accordance with EN 50289-1-X
5.1.1.6 Discharge (corona) test Not applicable
5.
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.