Solderless connections - Part 4: Solderless non-accessible insulation displacement connections - General requirements, test methods and practical guidance

EN following parallel vote * D114/118: CLC/TC 48B disbanded

Lötfreie elektrische Verbindungen - Teil 4: Lötfreie nichtzugängliche Schneidklemmverbindungen - Allgemeine Anforderungen, Prüfverfahren und Anwendungshinweise

Connexions sans soudure - Partie 4: Connexions autodénudantes, non accessibles sans soudure - Règles générales, méthodes d'essai et guide pratique

Solderless connections - Part 4: Solderless non-accessible insulation displacement connections - General requirements, test methods and practical guidance - Amendment A1 (IEC 60352-4:1994/A1:2000)

General Information

Status
Withdrawn
Publication Date
06-Dec-2000
Withdrawal Date
31-Oct-2003
Technical Committee
Drafting Committee
Parallel Committee
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
16-Jul-2023
Completion Date
16-Jul-2023

Relations

Buy Standard

Amendment
EN 60352-4:2002/A1:2002
English language
22 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI SIST EN 60352-4:2002/A1:2002
prva izdaja
STANDARD
september 2002
Solderless connections - Part 4: Solderless non-accessible insulation displacement
connections - General requirements, test methods and practical guidance -
Amendment A1 (IEC 60352-4:1994/A1:2000)
ICS 29.120.20 Referenčna številka
©  Standard je založil in izdal Slovenski inštitut za standardizacijo. Razmnoževanje ali kopiranje celote ali delov tega dokumenta ni dovoljeno

EUROPEAN STANDARD EN 60352-4/A1
NORME EUROPÉENNE
EUROPÄISCHE NORM December 2000

ICS 29.120.20
English version
Solderless connections
Part 4: Solderless non-accessible insulation displacement connections -
General requirements, test methods and practical guidance
(IEC 60352-4:1994/A1:2000)
Connexions sans soudure Lötfreie elektrische Verbindungen
Partie 4: Connexions autodénudantes, Teil 4: Lötfreie nichtzugängliche
non accessibles sans soudure - Schneidklemmverbindungen -
Règles générales, méthodes d'essai Allgemeine Anforderungen,
et guide pratique Prüfverfahren und Anwendungshinweise
(CEI 60352-4:1994/A1:2000) (IEC 60352-4:1994/A1:2000)

This amendment A1 modifies the European Standard EN 60352-4:1994; it was approved by CENELEC
on 2000-11-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this amendment the status of a national standard without any
alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This amendment exists in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CENELEC member into its own language and notified to the
Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic,
Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway,
Portugal, Spain, Sweden, Switzerland and United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels

© 2000 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.

Ref. No. EN 60352-4:1994/A1:2000 E

Page 2
Foreword
The text of document 48B/908/FDIS, future amendment 1 to IEC 60352-4:1994, prepared by SC 48B,
Connectors, of IEC TC 48, Electromechanical components and mechanical structures for electronic
equipment, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as
amendment A1 to EN 60352-4:1994 on 2000-11-01.
The following dates were fixed:
– latest date by which the amendment has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2001-08-01
– latest date by which the national standards conflicting
with the amendment have to be withdrawn (dow) 2003-11-01

Annexes designated "normative" are part of the body of the standard.
In this standard, annex ZA is normative.
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of amendment 1:2000 to the International Standard IEC 60352-4:1994 was approved by
CENELEC as an amendment to the European Standard without any modification.
__________
Page 3
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
Publication Year Title EN/HD Year
Add:
IEC Guide 109 1995 Environmental aspects - Inclusion in - -
electrotechnical product standards

IEC 60512-11-7 1996 Electromechanical components for EN 60512-11-7 1996
electronic equipment - Basic testing
procedures and measuring methods
Part 11: Climatic tests
Section 7: Test 11g: Flowing mixed
gas corrosion test
NORME
CEI
INTERNATIONALE IEC
60352-4
INTERNATIONAL
STANDARD
AMENDEMENT 1
AMENDMENT 1
2000-07
Amendement 1
Connexions sans soudure –
Partie 4:
Connexions autodénudantes, non accessibles
sans soudure – Règles générales,
méthodes d'essai et guide pratique
Amendment 1
Solderless connections –
Part 4:
Solderless non-accessible insulation
displacement connections –
General requirements, test methods and
practical guidance
© IEC 2000 Droits de reproduction réservés ⎯ Copyright - all rights reserved
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http://www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
R
PRICE CODE
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue

60352-4 Amend. 1 © IEC:2000 – 3 –
FOREWORD
This amendment has been prepared by subcommittee 48B: Connectors, of IEC technical
committee 48: Electromechanical components and mechanical structures for electronic
equipment.
The text of this amendment is based on the following documents:
FDIS Report on Voting
48B/908/FDIS 48B/937/RVD
Full information on the voting for the approval of this amendment can be found in the Report
on Voting in the above table.
The committee has decided that the contents of the base publication and its amendments will
remain unchanged until 2003. At this date, the publication will be
 reconfirmed;
 withdrawn;
 replaced by a revised edition, or
 amended.
–––––––––––
Page 3
CONTENTS
Replace Section 4 and clauses 14 to 18 by the following:
SECTION 4 – PRACTICAL GUIDANCE
14 General
15 Tool information
16 Termination information
17 Wire information
18 Connection information
19 ID connections, open housing design
20 ID connections, closed housing design
21 General additional information about ID connections as part of a multi-pole connector
22 Final remarks
60352-4 Amend. 1 © IEC:2000 – 5 –
Page 9
INTRODUCTION
Add, after Figure 1, the following new text:
IEC Guide 109 advocates the need to minimise the impact of a product on the natural
environment throughout the product life cycle.
It is understood that some of the materials permitted in this standard may have a negative
environmental impact.
As technological advances lead to acceptable alternatives for these materials, they will be
eliminated from the standard.
Page 11
3 Normative references
Add the following new references:
IEC Guide 109:1995, Environmental aspects – Inclusion in electrotechnical product standards
IEC 60512-11-7:1996, Electromechanical components for electronic equipment – Basic testing
procedures and measuring methods – Part 11: Climatic tests – Section 7: Test 11g: Flowing
mixed gas corrosion test
Page 43
12.4.3 Corrosion, industrial atmosphere
Replace the title and the text of this subclause by the following:
12.4.3 Flowing mixed gas, corrosion test
The test shall be carried out in accordance with test 11g of IEC 60512-11-7.
Unless otherwise specified by the detail specification, the following details shall apply:
Method: 1
Duration of exposure: 10 days
NOTE This test is a method with two mixed gases.
–9
H S: 100 ± 20 (10 vol/vol)
–9
SO : 500 ± 100 (10 vol/vol)
60352-4 Amend. 1 © IEC:2000 – 7 –
Page 47
Replace the existing table 3 by the following new table 3:
Table 3 – Number of specimens required
Non-reusable terminations Reusable terminations
Test For one wire For a range of wire For one wire For a range of wire
Subclause
schedule diameter diameters diameter diameters
only only
Maximum Minimum Maximum Minimum
Basic test 13.2.2.1 20 and 2 20 and 2 20 and 2 20 and 2 20 and 2 20 and 2
a a a a a a
schedule (optional) (optional) (optional) (optional) (optional) (optional)
13.2
b b
2 and 2 2 and 2
13.2.2.2
c c
(optional) (optional)
a a a a a a
Full test 13.3.2.1.1 2 (optional) 2 (optional) 2 (optional) 2 (optional) 2 (optional) 2 (optional)
schedule 13.3.2.1.2 20 20 20 20 20 20
13.3 13.3.2.1.3 20 20 20 20 20 20
13.3.2.1.4
20 20 20 20 20 20
b b
40 and 2 40 and 2
13.3.2.2
c c
(optional) (optional)
a
for microsection
b
for repeated connection (with the same termination, see 12.2.3)
c
for repeated connection (with the same termination, see 12.2.3) and microsection
13.2.2.1 Testing of non-accessible ID connections with reusable or
non-reusable terminations
Replace the first sentence by the following:
For testing non-reusable ID terminations, 20 specimens and 2 specimens (optional) are
required, and additionally, if terminations suitable for a range of wire diameters are to be
tested, 20 specimens and 2 specimens (optional).
Page 49
13.2.2.2 Additional testing of non-accessible ID connections with
reusable terminations
Replace the first line by the following:
For testing reusable ID terminations additionally 2 specimens and 2 specimens (optional) are
required.
60352-4 Amend. 1 © IEC:2000 – 9 –
Page 51
13.3.2.1 Testing of non-accessible ID connections with reusable or
non-reusable terminations
Replace the first sentence by the following:
For testing non-reusable ID terminations, 60 specimens and 2 specimens optional are
required, and additionally, if terminations suitable for a range of wire diameters are to be
tested, 60 specimens and 2 specimens (optional).
Page 57
13.3.2.2 Additional testing of non-accessible ID-connections with
reusable terminations
Replace the first line by the following:
For testing reusable ID terminations additionally 40 specimens and 2 specimens (optional) are
required.
60352-4 Amend. 1 © IEC:2000 – 11 –
Page 59
Replace the existing figure 11 by the following new figure 11:
Examination of parts
General examination of ID terminations and wires 12.1
20 or 22 sets of parts for non-reusable or reusable ID terminations
or
2 x (20 or 22) sets of parts for non-reusable or reusable ID terminations
suitable for a wire range
additionally
2 or 4 sets of parts for reusable ID terminations
- Visual examination test 1a
- Examination of dimensions and mass test 1b
Preparation of specimens
Initial examination of ID connections
20 or 22 specimens for non-reusable or reusable ID terminations
or
2 x (20 or 22) specimens for non-reusable or reusable ID terminations
suitable for a wire range
additionally
2 or 4 specimens for reusable ID terminations
- Visual examination test 1a
Testing
Non-reusable or reusable Reusable ID terminations
ID terminations additionally
2 specimens or
20 specimens or
2 specimens
for a wire range
for a wire range
2 specimens
(optional test)
2 x 2 specimens
2 x 20 specimens
(optional test)
- Contact
- Contact
- Microsection 12.2.4
- Repeated con-
resistance 2a/2b
resistance 2a/2b
nection and
- Bending of the
- Repeated con-
disconnection 12.2.3
wire 12.2.1
nection and
- Microsection 12.2.4
- Rapid change of
disconnection 12.2.3
temperature 11d
- Contact
- Damp heat,
resistance 2a/2b
cyclic 11m
- Contact
resistance 2a/2b
IEC  1552/2000
Figure 11 – Basic test schedule (see 13.2)

60352-4 Amend. 1 © IEC:2000 – 13 –
Page 61
Replace the existing figure 12 by the following new figure 12:
Examination of parts
General examination of ID terminations and wires
12.1
60 or 62 sets of parts for non-reusable or reusable ID terminations
or
2 x (60 or 62) sets of parts for non-reusable or reusable ID terminations
suitable for a wire range
additionally
40 or 42 sets of parts for reusable ID terminations
- Visual examination test 1a
- Examination of dimensions and mass
test 1b
Preparation of specimens
Initial examination of ID connections
62 specimens for non-reusable or reusable ID terminations
or
2 x (60 or 62) specimens for non-reusable or reusable ID terminations
suitable for a wire range
additionally
40 or 42 specimens for reusable ID terminations
test 1a
- Visual examination
Testing
Non-reusable or reusable
Reusable ID terminations
ID terminations
additionally
-  Repeated connection and
disconnection     12.2.3
2 specimens or 20 specimens or 20 specimens or 20 specimens or
2 specimens
20 specimens 20 specimens
2 x 2 specimens 2 x 20 2 x 20 2 x 20
(optional test)
a) a) a)
a)
(optional test) specimens specimens specimens
Group A Group B Group D Group C
Group C Group A Group D
- Contact resis- - Contact resis- - Contact resis- - Contact resis-
- Contact resis-
- Microsection 12.2.4 - Microsection 12.2.4
tance      2a/2b tance     2a/2b tance     2a/2b tance      2a/2b
tance     2a/2b
- Vibration plus
- Bending of the - Flowing mixed - Vibration plus - Flowing mixed
contact disturb-
wire       12.2.1 gases       11g contact disturb- gases      11g
- Electric load ance     6d+6e - Contact resis- ance     6d+ 6e
- Contact resis-
and tempera- - Rapid change tance     2a/2b - Rapid change
tance     2a/2b
of temperat ur  e 11d
ture          9b of temperat ur  e  11d
- Contact resis-
tance      2a/2b - Climatic - Climatic
seqence    11a sequence    11a
- Contact resis-
- Contact resis-
tance      2a/2b
tance     2a/2b
a)
Twice the number of specimens for a wire range
IEC  1553/2000
Figure 12 – Full test schedule (see 13.3)

60352-4 Amend. 1 © IEC:2000 – 15 –
Page 63
SECTION 4: PRACTICAL GUIDANCE
Replace the existing clauses of section 4 by the following new clauses:
14 General
This practical guidance is applicable for non-accessible ID connections made with insulated
stranded or solid copper conductors and is for information only. These connections shall be
produced by special wire insertion tools (fully automatic, semi-automatic or hand-operated
insertion tools). Conductors made of other materials (aluminium, etc.) often require special
actions regarding the ID-terminations and the insertion tools, which should be agreed upon by
the manufacturer.
14.1 Advantages of ID connections
An ID connection made by the ID technique is usually a permanent electrical connection
between one conductor and an ID termination of any shape. There are also terminations that
allow more than one wire insertion in the same connection slot. Good electrical connections
are achieved by exactly matching i
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.