EN 60318-1:1998
(Main)Electroacoustics - Simulators of human head and ear - Part 1: Ear simulator for the calibration of supra-aural earphones
Electroacoustics - Simulators of human head and ear - Part 1: Ear simulator for the calibration of supra-aural earphones
Relates to the specification of an ear simulator which covers the frequency band 20 Hz to 10 000 Hz and is intended for calibrating supra-aural earphones used in audiometry and telephonometry applied to the ear without acoustical leakage.
Elektroakustik - Simulatoren des menschlichen Kopfes und Ohres - Teil 1: Ohrsimulator zur Kalibrierung von supra-auralen Kopfhörern
Electroacoustique - Simulateurs de tête et d'oreille humaines - Partie 1: Simulateur d'oreille pour l'étalonnage des écouteurs supra-auraux
Cette norme est relative à la spécification d'un simulateur d'oreille couvrant le domaine des fréquences comprises entre 20 Hz et 10 000 Hz et destiné à l'étalonnage des écouteurs supra-auraux utilisés en audiométrie et en téléphonométrie et appliqués sur l'oreille sans fuite acoustique.
Electroacoustics - Simulator of human head and ear - Part 1: Ear simulator for the calibration of supra-aural earphones (IEC 60318-1:1998)
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2002
Electroacoustics - Simulator of human head and ear - Part 1: Ear simulator for the
calibration of supra-aural earphones (IEC 60318-1:1998)
Electroacoustics - Simulators of human head and ear -- Part 1: Ear simulator for the
calibration of supra-aural earphones
Elektroakustik - Simulatoren des menschlichen Kopfes und Ohres - Teil 1: Ohrsimulator
zur Kalibrierung von supra-auralen Kopfhörern
Electroacoustique - Simulateurs de tête et d'oreille humaines -- Partie 1: Simulateur
d'oreille pour l'étalonnage des écouteurs supra-auraux
Ta slovenski standard je istoveten z: EN 60318-1:1998
ICS:
13.140 Vpliv hrupa na ljudi Noise with respect to human
beings
17.140.50 Elektroakustika Electroacoustics
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
NORME
CEI
INTERNATIONALE
IEC
60318-1
INTERNATIONAL
Première édition
STANDARD
First edition
1998-07
Electroacoustique –
Simulateurs de tête et d’oreille humaines –
Partie 1:
Simulateur d’oreille pour l’étalonnage
des écouteurs supra-auraux
Electroacoustics –
Simulators of human head and ear –
Part 1:
Ear simulator for the calibration
of supra-aural earphones
IEC 1998 Droits de reproduction réservés Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in
utilisée sous quelque forme que ce soit et par aucun any form or by any means, electronic or mechanical,
procédé, électronique ou mécanique, y compris la photo- including photocopying and microfilm, without permission in
copie et les microfilms, sans l'accord écrit de l'éditeur. writing from the publisher.
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http: //www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
PRICE CODE L
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue
60318-1 IEC:1998 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
––––––––––
ELECTROACOUSTICS –
SIMULATORS OF HUMAN HEAD AND EAR –
Part 1: Ear simulator for the calibration of
supra-aural earphones
FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, the IEC publishes International Standards. Their preparation is
entrusted to technical committees; any IEC National Committee interested in the subject dealt with may
participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. The IEC collaborates closely with the International Organization
for Standardization (ISO) in accordance with conditions determined by agreement between the two
organizations.
2) The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an
international consensus of opinion on the relevant subjects since each technical committee has representation
from all interested National Committees.
3) The documents produced have the form of recommendations for international use and are published in the form
of standards, technical reports or guides and they are accepted by the National Committees in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with one of its standards.
6) Attention is drawn to the possibility that some of the elements of this International Standard may be the subject
of patent rights. The IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60318-1 has been prepared by IEC technical committee 29:
Electroacoustics.
This standard cancels and replaces IEC 60318:1970 and constitutes a technical revision.
The text of this standard is based on the following documents:
FDIS Report on voting
29/402/FDIS 29/412/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
Annexes A and B are for information only.
60318-1 IEC:1998 – 5 –
ELECTROACOUSTICS –
SIMULATORS OF HUMAN HEAD AND EAR –
Part 1: Ear simulator for the calibration of
supra-aural earphones
1 Scope
This International Standard relates to the specification of an ear simulator which covers the
frequency band 20 Hz to 10 000 Hz and is intended for calibrating supra-aural earphones used
in audiometry and telephonometry applied to the ear without acoustical leakage.
NOTE – This device is not intended for the calibration of circumaural earphones. However, IEC 60318-2 specifies
an adaptor for use with this ear simulator to provide an interim acoustic coupler for the calibration of a circumaural
audiometric earphone.
2 Normative reference
The following normative document contains provisions which, through reference in this text,
constitute provisions of this International Standard. At the time of publication, the edition
indicated was valid. All normative documents are subject to revision, and parties to agreements
based on this International Standard are encouraged to investigate the possibility of applying
the most recent editions of the normative documents indicated below. Members of IEC and ISO
maintain registers of currently valid International Standards.
IEC 61094-4:1995, Measurement microphones – Part 4: Specifications for working standard
microphones
3 Definitions
For the purpose of this International Standard, the following definitions apply.
3.1
ear simulator
device for the calibration of earphones which incorporates a calibrated microphone for the
measurement of sound pressure and an acoustic coupler. The overall acoustic impedance of
the simulator approximates that of the average human ear in a given frequency band
3.2
supra-aural earphone
earphone applied externally to the outer ear
3.3
circumaural earphone
earphone having a cavity large enough to cover the region of the head including
...