EN 60398:1999
(Main)Industrial electroheating installations - General test methods
Industrial electroheating installations - General test methods
Describes the test conditions, fundamental measurements and general test methods applicable to all industrial electroheat installations to confirm their safety and performance specifications. It is intended to be used in conjunction with the relevant particular standards where there exist.
Industrielle Elektrowärmeanlagen - Allgemeine Prüfverfahren
Chauffage électrique industriel - Méthodes générales d'essai
Décrit les conditions d'essais, les mesures fondamentales et les méthodes générales d'essais applicables à toutes les installations électrothermiques industrielles pour confirmer leurs spécifications de fonctionnement et de sécurité. Elle est destinée à être utilisée conjointement avec les règles particulières, lorsqu'elles existent.
Industrial electroheating installations - General test methods
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2001
Industrial electroheating installations - General test methods
Industrial electroheating installations - General test methods
Industrielle Elektrowärmeanlagen - Allgemeine Prüfverfahren
Chauffage électrique industriel - Méthodes générales d'essai
Ta slovenski standard je istoveten z: EN 60398:1999
ICS:
25.180.10 (OHNWULþQHSHþL Electric furnaces
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
-
...
This May Also Interest You
This part of IEC 60519 is applicable to equipment using high frequency or microwave energy alone or in combination with other kinds of energy for industrial heating and processing of materials. It is also applicable to HF and MW generators made available to users as separate units. This part is applicable to equipment operating in the frequency range 3 MHz to 300 GHz, with the following limitations. - This document applies to only high frequency dielectric heating and processing as defined in 3.1.103. It does not apply to induction heating, which it is possible to carry out in the lower part of the specified frequency band and is covered by IEC 60519-3, with magnetic field safety aspects addressed in IEC TS 62997:2017, the latter to be replaced by a technical report (TR) or by a revised technical specification (TS). - The ISM centre frequencies for dielectric heating and processing of industrial interest are narrow bands about 6,78 MHz, 13,56 MHz, 27,12 MHz and 40,68 MHz. Different field emission measurement procedures and limiting values are applicable, depending on the processing frequency in the high frequency range 3 to 300 MHz. Specifications are in Annex BB. - This document specifies limits for microwave emission only for the ISM frequencies between 800 MHz and 6 MHz, as specified in Annex CC. For other microwave frequencies the basic restriction and IEC 62311 apply. - The foundations for compliance with emission values are the basic restrictions, referred to in the IEEE/ANSI C95.1:2019 and Directive 2013/35/EU. However, maximum HF processing frequency electric and magnetic field values are taken from the IEEE/ANSI C95.1:2019 standard, as indicated in Annex BB. - This document is not applicable to: -- appliances for household and similar use (covered by e.g. IEC 60335-2-25); -- commercial use (covered by IEC 60335-2-90 and IEC 60335-2-110); -- laboratory use (covered by IEC 61010-2-010); -- medical high frequency equipment and accessories (covered by IEC 60601-2-2). NOTE 101 Since high frequency and microwave tunnel ovens and also some other types of microwave and high frequency equipment are sometimes intended either for commercial, laboratory or industrial use, the following criteria are suitable for determination of the classification as industrial equipment: - commercial equipment is typically designed and planned for series production of many identical units, whereas industrial equipment is typically produced in small series or even as single units. The processed goods are consumed or ready for final use at the end of the heating process. - laboratory heating equipment is for preparing material in a laboratory environment, and the processed material is immediately available for investigations or further processing. Regular production of large quantities of material is not foreseen. - with industrial equipment, the processed goods are not immediately accessible to the end user, and the goods are sometimes not in a final state from the perspective of the end user.
- Standard70 pagesEnglish languagesale 10% offe-Library read for×1 day
- 09-May-2024
- 25-Sep-2022
- 25.180.10
- 2006/95/EC
- 2014/35/EU
- M/511
- CLC/SR 27
IEC 60676:2024 This document specifies the basic test procedures, conditions and methods for establishing the main performance parameters and the main operational characteristics of furnaces for direct arc heating, forming arcs between the electrode and metal, such as electric arc furnaces using alternating current (EAF AC) or direct current (EAF DC), and ladle furnaces (LF), with rated power level above 500 kVA . This fourth edition cancels and replaces the third edition published in 2011. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) The structure has been redrafted according to IEC 60398:2015. b) The scope has been redrafted. c) The terms/definitions, normative references and bibliography have been updated and completed. d) The test methods and content from IEC 60398:2015 have been confirmed, replaced, or complemented with regards to direct arc furnaces (EAF, LF). e) The annexes from IEC 60398:2015 have been confirmed, replaced, or complemented with regards to direct arc furnaces (EAF, LF).
- Standard41 pagesEnglish languagesale 10% offe-Library read for×1 day
This part of IEC 60519 provides particular safety requirements for arc furnace installations. This document deals with the significant hazards, hazardous situations or hazardous events relevant to industrial arc furnace installations, as listed in Annex A, for normal operation and for single fault condition as well as under conditions of reasonably foreseeable misuse. This document specifies the requirements intended to be met by the manufacturer to ensure the safety of persons and property during the complete life cycle of the equipment from design through commissioning, operation, maintenance, inspection, to decommissioning, as well as in the event of foreseeable single fault condition that can occur in the equipment. The rated voltage of arc furnace installation can be in the range of low voltage or high voltage, details are given in 4.2. This standard is applicable to arc furnace installations such as: a) furnaces for direct arc heating, forming arcs between the electrode and metal such as the electric arc furnace using alternating current (EAF AC) or direct current (EAF DC), and the ladle furnace (LF); b) furnaces for arc-resistance heating forming arcs between the electrode and the charge material or heating the charge material by the Joule effect, such as the submerged arc resistance furnace using alternating current (SAF AC), or direct current (SAF DC). NOTE In some documents the terms smelter or electrical reduction furnace are used. Furnace installation for unattended operation is not covered by this standard. This document does not provide requirements for type testing. NOTE Industrial equipment covered by this document is typically produced as a single unit or a very small number of units; such unit usually has a very high value and can cause severe harm at disintegration. This document does not address data security and hazards arising from neglect of security. With respect to noise of electrical an arc furnace, ISO 13578:2017, 6.1.23 applies.
- Standard57 pagesEnglish languagesale 10% offe-Library read for×1 day
- 03-Feb-2022
- 25.180.10
- 2014/35/EU
- M/511
- CLC/SR 27
IEC 60779:2020 specifies the test procedures, conditions and methods for determining the main performance parameters and operational characteristics of electroslag remelting furnaces. Measurements and tests that are solely used for the verification of safety requirements of the installations are outside the scope of this document and are covered by IEC 60519-1 and IEC 60519-8. This third edition cancels and replaces the second edition published in 2005. It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - the structure has been redrafted according to IEC 60398:2015; - the scope and object have been redrafted; - the terms/definitions, normative references and bibliography have been updated and completed; - all test methods and content from IEC 60779:2005 that have been included in IEC 60398:2015 have been removed to avoid any duplication.
- Standard26 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 60519-8:2020 specifies particular safety requirements for electroslag remelting equipment and installations. This document specifies safety requirements applicable to mainly electroheating installations for remelting and, in some cases, for refining processes of metals through direct resistance heating of a conductive slag. The object of this document is to specify the particular requirements for the safety of persons in or around an electroslag remelting furnace. The general requirements are included in IEC 60519-1. This third edition cancels and replaces the second edition published in 2005. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) the structure has been redrafted according to IEC 60519-1:2020; b) the Scope has been redrafted; c) the terms and definitions, normative references and bibliography have been updated and completed; d) all requirements and content from IEC 60519-8:2005 that have been included in IEC 60519‑1:2020 have been removed to avoid any duplication.
- Standard28 pagesEnglish languagesale 10% offe-Library read for×1 day
- 25-Jun-2020
- 25.180.10
- 2014/35/EU
- CLC/SR 27
IEC 60519-1:2020 is available as IEC 60519-1:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60519-1:2020 specifies the general safety requirements for industrial installations or equipment intended for electroheating (EH) and electroheating based treatment technologies as well as for electromagnetic processing of materials (EPM). This document deals with the significant hazards, hazardous situations or hazardous events relevant to industrial EH and EPM equipment, as listed in Annex A, for normal operation and for single fault condition as well as under conditions of reasonably foreseeable misuse. This sixth edition cancels and replaces the fifth edition published in 2015. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - removal of noise from the scope; - clarification of EMC requirements; - risk classification of hazards based on emission for all processing frequencies; - clarification of boundaries between IEC 60519 (all parts) and ISO 13577 (all parts).
- Standard105 pagesEnglish languagesale 10% offe-Library read for×1 day
- 28-May-2020
- 25.180.10
- 2014/35/EU
- M/511
- CLC/SR 27
IEC 63078:2019 specifies the test procedures, conditions and methods for determining the main performance parameters and operational characteristics of induction through-heating installations. Measurements and tests that are solely used for the verification of safety requirements of the installations are outside the scope of this document and are covered by IEC 60519-1 and IEC 60519-3.
- Standard38 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 60519-12:2016 specifies safety requirements for industrial electroheating equipment and installations in which infrared radiation – usually generated by infrared emitters – is significantly dominating over heat convection or heat conduction as means of energy transfer to the workload. A further limitation of the scope is that the infrared emitters have a maximum spectral emission at longer wavelengths than 780 nm in air or vacuum, and are emitting wideband continuous spectra such as by thermal radiation or high pressure arcs. This second edition cancels and replaces the first edition published in 2013. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a. the structure has been redrafted according to IEC 60519-1:2015; b. terms/definitions, normative references and bibliography have been updated and completed; c. all requirements and content from IEC 60519-12:2013 that have been included in IEC 60519-1:2015 have been removed to avoid any duplication.
- Standard36 pagesEnglish languagesale 10% offe-Library read for×1 day
- Standard36 pagesEnglish languagesale 10% offe-Library read for×1 day
- 01-Mar-2018
- 01-Mar-2021
- 25.180.10
- 2006/42/EC
- 2014/35/EU
- M/396
- M/511
- CLC/SR 27
IEC 60398:2015 specifies the basic test procedures, conditions and methods for establishing the main performance parameters and the main operational characteristics of industrial installations and equipment intended for electroheating (EH) or electromagnetic processing of materials (EPM). This third edition cancels and replaces the second edition of IEC 60398 published in 1999 and the first edition of IEC TS 62796 published in 2013. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - the title and scope of the standard have been expanded to include installations and equipment for electromagnetic processing of materials; - the requirements have been restructured; - tests concerning safety have been moved to IEC 60519-1; - new tests and clauses addressing energy efficiency considerations have been added; - a new annex placing this standard in the context of energy efficiency assessment as developed by ISO and IEC has been added; - new annexes addressing visual display of data, estimation of energy use and energy recoverability of fluids have been added.
- Standard39 pagesEnglish languagesale 10% offe-Library read for×1 day
- Corrigendum1 pageEnglish and French languagesale 10% offe-Library read for×1 day
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.