Secondary cells and batteries containing alkaline or other non-acid electrolytes - Nickel-cadmium prismatic secondary single cells with partial gas recombination

This International Standard specifies marking, designation, dimensions, tests and require-ments for vented nickel-cadmium prismatic secondary single cells where special provisions have been made in order to have partial or, under very specific conditions, full gas recombination.

Sekundärzellen und -batterien mit alkalischem oder anderen nichtsäurehaltigen Elektrolyten - Wiederaufladbare prismatische Nickel-Cadmium-Einzelzellen mit teilweiser Gasrekombination

Accumulateurs alcalins et autres accumulateurs à électrolyte non acide - Eléments d'accumulateurs individuels parallélépipédiques au nickel-cadmium à recombinaison partielle des gaz

La présente Norme internationale spécifie le marquage, la désignation, les dimensions, les essais et les prescriptions applicables aux éléments d'accumulateurs individuels parallé-lépipédiques, ouverts, au nickel-cadmium pour lesquels des dispositions spéciales ont été prises afin d'avoir une recombinaison partielle, ou dans certaines conditions très spécifiques, une recombinaison complète des gaz.

Secondary cells and batteries containing alkaline or other non-acid electrolytes - Nickel-cadmium prismatic secondary single cells with partial gas recombination

General Information

Status
Published
Publication Date
11-Jan-2004
Withdrawal Date
30-Nov-2006
Current Stage
6060 - Document made available - Publishing
Start Date
12-Jan-2004
Completion Date
12-Jan-2004

Relations

Overview

EN 62259:2004 (CLC) is the European adoption of an international standard for secondary cells and batteries containing alkaline or other non‑acid electrolytes. It specifically covers nickel‑cadmium prismatic secondary single cells with partial gas recombination. The standard specifies marking, designation, dimensions, tests and requirements for vented prismatic Ni‑Cd cells where special design provisions enable partial - and in very specific conditions, full - gas recombination.

Key Topics

The standard addresses the essential technical and conformity aspects of vented nickel‑cadmium prismatic cells, including:

  • Marking and designation: mandatory identification and labeling requirements for safe use and traceability.
  • Dimensions: physical size and form‑factor specifications to ensure compatibility with holders and battery assemblies.
  • Tests: standardized test requirements to assess behaviour of vented prismatic Ni‑Cd single cells with gas recombination features.
  • Requirements for gas recombination: provisions and acceptance criteria for cells designed to recombine evolved gases partially (or under specific conditions, fully) rather than venting them freely.
  • Venting and safety considerations: measures related to venting behaviour when recombination provisions are present.

These topics help define both manufacturing tolerances and QA/test regimes without prescribing proprietary cell designs.

Applications

EN 62259:2004 is used where prismatic nickel‑cadmium single cells are manufactured, tested, specified or purchased. Typical users include:

  • Battery manufacturers designing and certifying vented Ni‑Cd prismatic cells with recombination features.
  • Test laboratories and conformity assessment bodies performing standardized tests and issuing certificates.
  • Product designers and system integrators who specify battery cells for emergency power, industrial equipment, communications or transportable electronics.
  • Quality assurance and procurement teams ensuring incoming cell batches meet European standard requirements.
  • Regulators and safety engineers assessing compliance with harmonized Europe-wide battery requirements.

Using EN 62259 helps ensure consistent marking, interchangeability, predictable venting/recombination behaviour, and reliable baseline testing across suppliers.

Related Standards

For broader battery safety and performance context, EN 62259:2004 is part of a family of EN/IEC standards for secondary cells and batteries covering different chemistries, test methods and safety topics. When specifying or testing Ni‑Cd prismatic cells, stakeholders commonly reference related EN/IEC documents governing cell safety, transport, and system integration.

Keywords: EN 62259:2004, nickel‑cadmium prismatic, partial gas recombination, vented Ni‑Cd cells, battery standards, CLC, marking designation dimensions tests requirements.

Standard
EN 62259:2004
English language
21 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-marec-2004
Secondary cells and batteries containing alkaline or other non-acid electrolytes -
Nickel-cadmium prismatic secondary single cells with partial gas recombination
Secondary cells and batteries containing alkaline or other non-acid electrolytes - Nickel-
cadmium prismatic secondary single cells with partial gas recombination
Sekundärzellen und -batterien mit alkalischem oder anderen nichtsäurehaltigen
Elektrolyten - Wiederaufladbare prismatische Nickel-Cadmium-Einzelzellen mit teilweiser
Gasrekombination
Accumulateurs alcalins et autres accumulateurs à électrolyte non acide - Eléments
d'accumulateurs individuels parallélépipédiques au nickel-cadmium à recombinaison
partielle des gaz
Ta slovenski standard je istoveten z: EN 62259:2004
ICS:
29.220.30 $ONDOQLVHNXQGDUQLþOHQLLQ Alkaline secondary cells and
EDWHULMH batteries
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...

Frequently Asked Questions

EN 62259:2004 is a standard published by CLC. Its full title is "Secondary cells and batteries containing alkaline or other non-acid electrolytes - Nickel-cadmium prismatic secondary single cells with partial gas recombination". This standard covers: This International Standard specifies marking, designation, dimensions, tests and require-ments for vented nickel-cadmium prismatic secondary single cells where special provisions have been made in order to have partial or, under very specific conditions, full gas recombination.

This International Standard specifies marking, designation, dimensions, tests and require-ments for vented nickel-cadmium prismatic secondary single cells where special provisions have been made in order to have partial or, under very specific conditions, full gas recombination.

EN 62259:2004 is classified under the following ICS (International Classification for Standards) categories: 29.220.99 - Other cells and batteries. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 62259:2004 has the following relationships with other standards: It is inter standard links to prEN IEC 62259:2025. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

You can purchase EN 62259:2004 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of CLC standards.