Deals with the safety of tools which the rated voltage is not more than 250 V for single-phase a.c. or d.c. tools and 440 V for three-phase a.c. tools. Supplements or modifies the corresponding clauses of IEC 60745-1
Handgeführte motorbetriebene Elektrowerkzeuge - Sicherheit - Teil 2-21: Besondere Anforderungen für Rohrreinigungsgeräte
Outils électroportatifs à moteur - Sécurité - Partie 2-21: Règles particulières pour les curettes
Traite de la sécurité des outils dont la tension assignée n'est pas supérieure à 250 V en courant monophasé alternatif ou courant continu et 440 V en courant alternatif triphasé. Complète ou modifie les articles correspondants de la CEI 60745-1.
Ročna električna orodja - Varnost - 2-21. del: Posebne zahteve za čistilnike odtokov (IEC 60745-2-21:2002, spremenjen)
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Hand-held motor-operated electric tools - Safety - Part 2-21: Particular requirements for drain cleanersOutils électroportatifs a moteur - Sécurité - Partie 2-21: Regles particulieres pour les curettesHandgeführte motorbetriebene Elektrowerkzeuge - Sicherheit - Teil 2-21: Besondere Anforderungen für RohrreinigungsgeräteTa slovenski standard je istoveten z:EN 60745-2-21:2007SIST EN 60745-2-21:2008en,fr,de91.140.70Sanitarne napraveSanitary installations25.140.20Electric toolsICS:SLOVENSKI
STANDARDSIST EN 60745-2-21:200801-januar-2008
EUROPEAN STANDARD EN 60745-2-21 NORME EUROPÉENNE
EUROPÄISCHE NORM May 2007
CENELEC European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2007 CENELEC -
All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60745-2-21:2007 E
ICS 25.140.20; 91.140.70
English version
Hand-held motor-operated electric tools -
Safety -
Part 2-21: Particular requirements for drain cleaners (IEC 60745-2-21:2002, modified)
Outils électroportatifs à moteur -
Sécurité -
Partie 2-21: Règles particulières
pour les curettes
(CEI 60745-2-21:2002, modifiée)
Handgeführte motorbetriebene Elektrowerkzeuge -
Sicherheit -
Teil 2-21: Besondere Anforderungen
für Rohrreinigungsgeräte (IEC 60745-2-21:2002, modifiziert)
This European Standard was approved by CENELEC on 2007-05-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom.
EN 60745-2-21 on 2007-05-01. The following dates were fixed: – latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement
(dop)
2008-05-01 – latest date by which the national standards conflicting with the EN have to be withdrawn
(dow)
2010-05-01 This standard is divided into two parts: Part 1: General requirements which are common to most hand-held electric motor operated tools (for the purpose of this standard referred to simply as tools) which could come within the scope of this standard; Part 2: Requirements for particular types of tools which either supplement or modify the requirements given in Part 1 to account for the particular hazards and characteristics of these specific tools. This European Standard has been prepared under a mandate given to CENELEC by the European Commission and the European Free Trade Association and covers essential health and safety requirements of EC Directive 98/37/EC, amended by EC Directive 98/79/EC. See Annex ZZ. Compliance with the clauses of Part 1 together with this Part 2 provides one means of conforming with the essential health and safety requirements of the Directives concerned. Warning: Other requirements and other EC Directives can be applicable to the products falling within the scope of this standard. This standard follows the overall requirements of EN ISO 12100-1 and EN ISO 12100-2. This Part 2-21 is to be used in conjunction with EN 60745-1:2006. When this standard states "addition", "modification" or "replacement", the relevant text in Part 1 is to be adapted accordingly. Subclauses and figures which are additional to those in Part 1 are numbered starting from 101. Subclauses, tables and figures which are additional to those in IEC 60745-2-21 are prefixed “Z”. Annex ZZ was added by CENELEC. NOTE In this standard the following print types are used:
- requirements proper: in roman type;
- test specifications: in italic type;
- explanatory matter: in smaller roman type. __________
- 3 - EN 60745-2-21:2007 Endorsement notice The text of the International Standard IEC 60745-2-21:2002 was approved by CENELEC as a European Standard with agreed common modifications as given below. COMMON MODIFICATIONS 6 Void Replace by: 6 Environmental requirements This clause of Part 1 is applicable except as follows: 6.1.2.4 Modification: Drain cleaners are suspended at an angle of 45° downwards from the horizontal. 6.1.2.5 Modification: Drain cleaners are tested at no load in the forward direction. During the test, the drain cleaner cable is inside the drum. 6.2.4.2 Location of the measurement Addition: Figure Z101 shows the positions for drain cleaners. 6.2.6.3 Operating conditions Modification: Table Z101 - Operating conditions for drain cleaners Orientation Drain cleaners are tested at no load in the forward direction. The drain cleaner is held at an angle of 45° downwards from the horizontal. Tool bit The drain cleaner cable is inside the drum. Grip force Hold the machine with normal gripping force, at the pistol handle and the drum hand grip surface, avoiding excessive gripping force. Test cycle One test cycle is given when the tool is switched on for no load at maximum speed for more than 10 s and then switched off again. The measurement is conducted during 10 s within this period. NOTE
For drain cleaners, no load condition is the worst case for vibration. Typically these tools carry 8 m to 12 m of drain cleaner cable and a large portion of any vibration is due to the cable in the drum not running true. Also, the highest speed is at idle and therefore will cause the highest vibration. Little or no vibration is transmitted from the cable being in the drain since the drain cleaner cable is basically a large spring and acts as a dampener.
Figure Z101 - Positions of transducers for drain cleaners
- 5 - EN 60745-2-21:2007 Add the following annex: Annex ZZ (informative)
Coverage of Essential Requirements of EC Directives This European Standard has been prepared under a mandate given to CENELEC by the European Commission and the European Free Trade Association and within its scope the standard covers all relevant essential requirements as given in Annex I of the Machinery Directive 98/37/EC, amended by Directive 98/79/EC. Compliance with this standard provides one means of conformity with the specified essential requirements of the Directives concerned. WARNING: Other requirements and other EC Directives may be applicable to the products falling wi
...