Discharge lamps (excluding fluorescent lamps) - Safety specifications

Specifies the safety requirements for discharge lamps (excluding fluorescent lamps) for general lighting purposes. This International Standard is applicable to low-pressure sodium vapour lamps and to high-intensity discharge (HID) lamps, i.e. high-pressure mercury vapour lamps (including blended lamps), high-pressure sodium vapour lamps and metal halide lamps. It applies to single- and double-capped lamps.

Entladungslampen (ausgenommen Leuchtstofflampen) - Sicherheitsanforderungen

Lampes à décharge (à l'exclusion des lampes à fluorescence) - Prescriptions de sécurité

Spécifie les prescriptions de sécurité auxquelles doivent répondre les lampes à décharge (à l'exclusion des lampes à fluorescence) destinées à l'éclairage général. Cette Norme internationale est applicable aux lampes à vapeur de sodium à basse pression et aux lampes à décharge à haute intensité (DHI), c'est-à-dire les lampes à vapeur de mercure à haute pression (y compris lampes à lumière mixte), lampes à vapeur de sodium à haute pression et lampes aux halogénures métalliques.

Razelektrilne sijalke (razen fluorescenčnih sijalk) - Varnostne specifikacije (IEC 62035:1999)

Ta mednarodni standard določa varnostne zahteve za razelektrilne sijalke (razen fluorescenčnih sijalk) za splošno uporabo v razsvetljavi. Ta mednarodni standard se uporablja za nizkotlačne natrijeve sijalke in razelektrilne sijalke visoke intenzivnosti (HID), npr. visokotlačne sijalke iz živega srebra (vključno z mešanimi sijalkami), visokotlačne natrijeve sijalke in sijalke s kovinskim halidom. Uporablja se za sijalke z enim ali dvema vznožkoma, ki so navedene v prilogi A. Zahteve iz tega standarda veljajo samo za tipsko preskušanje. Pogoji skladnosti, vključno z metodami statističnega ocenjevanja, so v obravnavi. OPOMBA Ta standard se nanaša samo na varnostne zahteve in ne upošteva zmogljivosti. Te značilnosti obravnavajo standardi za zmogljivost IEC 60188, IEC 60192, IEC 60662, IEC 61167 in IEC 61549. Pričakuje se lahko, da se bodo sijalke, ki so v skladu s tem standardom, varno delovale pri napetostih od 90 % do 110 % nazivne napajalne napetosti in ko so opremljene z dušilko, ki je v skladu s standardoma IEC 60922 in IEC 60923, vklopno napravo, ki je v skladu s standardoma IEC 60926 in IEC 60927 ter svetilko, ki je v skladu s standardom IEC 60598-1.

General Information

Status
Withdrawn
Publication Date
23-Jan-2000
Withdrawal Date
30-Nov-2002
Drafting Committee
Parallel Committee
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
15-Sep-2017
Completion Date
15-Sep-2017

Relations

Buy Standard

Standard
EN 62035:2000
English language
25 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-junij-2000
5D]HOHNWULOQHVLMDONH UD]HQIOXRUHVFHQþQLKVLMDON 9DUQRVWQHVSHFLILNDFLMH ,(&

Discharge lamps (excluding fluorescent lamps) - Safety specifications (IEC 62035:1999)
Entladungslampen (ausgenommen Leuchtstofflampen) - Sicherheitsanforderungen (IEC
62035:1999)
Lampes à décharge (à l'exclusion des lampes à fluorescence) - Prescriptions de sécurité
(CEI 62035:1999)
Ta slovenski standard je istoveten z: EN 62035:2000
ICS:
29.140.30 )OXRUHVFHQþQHVLMDONH6LMDONH Fluorescent lamps.
Discharge lamps
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

NORME CEI
INTERNATIONALE IEC
INTERNATIONAL
Première édition
STANDARD
First edition
1999-10
Lampes à décharge
(à l'exclusion des lampes à fluorescence) –
Prescriptions de sécurité
Discharge lamps
(excluding fluorescent lamps) –
Safety specifications
 IEC 1999 Droits de reproduction réservés  Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in
utilisée sous quelque forme que ce soit et par aucun procédé, any form or by any means, electronic or mechanical,
électronique ou mécanique, y compris la photo-copie et les including photocopying and microfilm, without permission in
microfilms, sans l'accord écrit de l'éditeur. writing from the publisher.
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http://www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
S
PRICE CODE
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue

62035  IEC:1999 – 3 –
CONTENTS
Page
FOREWORD . 5
Clause
1 Scope . 7
2 Normative references . 7
3 Definitions. 9
4 General safety requirements. 11
4.1 General. 11
4.2 Marking. 13
4.3 Mechanical requirements . 13
4.4 Electrical requirements. 17
4.5 Thermal requirements . 19
5 Particular safety requirements . 21
5.1 High-pressure sodium vapour lamps. 21
5.2 Metal halide lamps . 21
6 Information for luminaire design . 21
Annex A (normative) List of lamp caps and gauges . 23
Annex B (normative) Pull and torsion test values . 25
Annex C (normative) Torsion test holders. 27
Annex D (normative) Information for thermal tests . 31
Annex E (normative) Measurement of pulse height for lamps with internal starting device. 33
Annex F (informative) Information for luminaire design. 39

62035  IEC:1999 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
DISCHARGE LAMPS
(EXCLUDING FLUORESCENT LAMPS) –
SAFETY SPECIFICATIONS
FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, the IEC publishes International Standards. Their preparation is
entrusted to technical committees; any IEC National Committee interested in the subject dealt with may
participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. The IEC collaborates closely with the International Organization
for Standardization (ISO) in accordance with conditions determined by agreement between the two
organizations.
2) The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an
international consensus of opinion on the relevant subjects since each technical committee has representation
from all interested National Committees.
3) The documents produced have the form of recommendations for international use and are published in the form
of standards, technical reports or guides and they are accepted by the National Committees in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with one of its standards.
6) Attention is drawn to the possibility that some of the elements of this International Standard may be the subject
of patent rights. The IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 62035 has been prepared by subcommittee 34A: Lamps, of IEC
technical committee 34: Lamps and related equipment.
This standard replaces and combines the safety requirements previously contained in
IEC 60188, IEC 60192, IEC 60662 and IEC 61167.
The text of this standard is based on the following documents:
FDIS Report on voting
34A/885/FDIS 34A/899/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with ISO/IEC Directives, Part 3.
Annexes A, B, C, D and E form an integral part of this standard.
Annex F is for information only.
The committee has decided that this publication remains valid until 2002-09. At this date, in
accordance with the committee's decision, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
62035  IEC:1999 – 7 –
DISCHARGE LAMPS
(EXCLUDING FLUORESCENT LAMPS) –
SAFETY SPECIFICATIONS
1 Scope
This International Standard specifies the safety requirements for discharge lamps (excluding
fluorescent lamps) for general lighting purposes.
This International Standard is applicable to low-pressure sodium vapour lamps and to high-
intensity discharge (HID) lamps, i.e. high-pressure mercury vapour lamps (including blended
lamps), high-pressure sodium vapour lamps and metal halide lamps. It applies to single- and
double-capped lamps, having caps as listed in annex A.
The requirements of this standard relate only to type testing. Conditions of compliance,
including methods of statistical assessment, are under consideration.
NOTE This standard only concerns safety criteria and does not take into account performance. The performance
standards IEC 60188, IEC 60192, IEC 60662, IEC 61167 and IEC 61549 should be referred to for such
characteristics.
It may be expected that lamps which comply with this standard will operate safely at supply
voltages between 90 % and 110 % of rated supply voltage and when operated with a ballast
complying with IEC 60922 and IEC 60923, with a starting device complying with IEC 60926 and
IEC 60927, and in a luminaire complying with IEC 60598-1.
2 Normative references
The following normative documents contain provisions which, through reference in this text,
constitute provisions of this International Standard. For dated references, subsequent
amendments to, or revisions of, these publications do not apply. However, parties to
agreements based on this International Standard are encouraged to investigate the possibility
of applying the most recent editions of the normative documents indicated below. For undated
references, the latest edition of the normative document referred to applies. Members of IEC
and ISO maintain registers of currently valid International Standards.
IEC 60050(845), International Electrotechnical Vocabulary (IEV) – Chapter 845: Lighting
IEC 60061-1, Lamp caps and holders together with gauges for the control of interchangeability
and safety – Part 1: Lamp caps
IEC 60061-2, Lamp caps and holders together with gauges for the control of interchangeability
and safety – Part 2: Lampholders
IEC 60061-3, Lamp caps and holders together with gauges for the control of interchangeability
and safety – Part 3: Gauges
IEC 60061-4, Lamp caps and holders together with gauges for the control of interchangeability
and safety – Part 4: Guidelines and general information
IEC 60155, Glow-starters for fluorescent lamps

62035  IEC:1999 – 9 –
IEC 60598-1, Luminaires – Part 1: General requirements and tests
IEC 60662, High-pressure sodium vapour lamps
IEC 60695-2-1/0, Fire hazard testing – Part 2: Test methods – Section 1/Sheet 0: Glow-wire
test methods – General
IEC 60922, Auxiliaries for lamps – Ballasts for discharge lamps (excluding tubular fluorescent
lamps) – General and safety requirements
IEC 60923, Auxiliaries for lamps – Ballasts for discharge lamps (excluding tubular fluorescent
lamps) – Performance requirements
IEC 60926, Auxiliaries for lamps – Starting devices (other than glow starters) – General and
safety requirements
IEC 60927, Auxiliaries for lamps – Starting devices (other than glow starters) – Performance
requirements
IEC 61167, Metal halide lamps
ISO 4046, Paper, board, pulp and related terms – Vocabulary
3 Definitions
For the purposes of this International Standard, the following terms and definitions apply, as
well as others given in IEC 60050(845).
3.1
high-intensity discharge lamp; HID lamp
electric discharge lamp in which the light-producing arc is stabilized by wall temperature and
the arc has a bulb wall loading in excess of 3 watts per square centimetre
NOTE HID lamps include groups of lamps known as high-pressure mercury, metal halide and high-pressure
sodium lamps.
[IEV 845-07-19]
3.2
high-pressure mercury (vapour) lamp
high-intensity discharge lamp in which the major portion of the light is produced, directly or
indirectly, by radiation from mercury operating at a partial pressure in excess of 100 kilo-
pascals
NOTE This term covers clear, phosphor coated (mercury fluorescent) and blended lamps. In a fluorescent mercury
discharge lamp, the light is produced partly by the mercury vapour and partly by the layer of phosphors excited by
the ultraviolet radiation of the discharge.
[IEV 845-07-20]
3.3
blended lamp; self-ballasted mercury lamp (USA)
lamp containing in the same bulb certain elements of a mercury vapour lamp and an
incandescent lamp filament connected in series
NOTE The bulb may be diffusing or coated with phosphors.
[IEV 845-07-21, modified]
62035  IEC:1999 – 11 –
3.4
high-pressure sodium (vapour) lamp
high-intensity discharge lamp in which the light is produced mainly by radiation from sodium
vapour operating at a partial pressure of the order of 10 kilopascals
NOTE The term covers lamps with clear or diffusing bulb.
[IEV 845-07-23]
3.5
low-pressure sodium (vapour) lamp
discharge lamp in which the light is produced by radiation from sodium vapour operating at a
partial pressure of 0,1 to 1,5 pascal
[IEV 845-07-24]
3.6
metal halide lamp
high-intensity discharge lamp in which the major portion of the light is produced by radiation
from a mixture of metallic vapour, metal halides and the products of the dissociation of metal
halides
NOTE The definition covers clear and coated lamps.
[IEV 845-07-25, modified]
3.7
nominal wattage
approximate quantity value of lamp wattage used to designate or identify a lamp
3.8
specific effective radiant UV power
effective power of the UV radiation of a lamp related to its luminous flux (unit: mW/klm)
NOTE The effective power of the UV radiation is obtained by weighting the spectral power distribution of the lamp
with the action spectrum published by the American Conference of Governmental Industrial Hygienists (ACGIH),
which is endorsed by the World Health Organization (WHO) and recommended by the International Radiation
Protection Association (IRPA).
3.9
type test
test or series of tests made on a type test sample for the purpose of checking compliance of
the design of a given product with the requirements of the relevant standard
3.10
type test sample
sample consisting of one or more similar units submitted by the manufacturer or responsible
vendor for the purpose of the type test
4 General safety requirements
4.1 General
Lamps shall be so designed and constructed that in normal use they present no danger to the
user or the surroundings.
In general, compliance is checked by carrying out all the tests specified in this standard.

62035  IEC:1999 – 13 –
4.2 Marking
4.2.1 Lamp marking
Lamps shall be marked as follows:
– mark of origin, which may take the form of a trade mark, the manufacturer's name or the
name of the responsible vendor;
– nominal wattage (marked "W" or "watts") and/or any other indication which identifies the
lamp.
NOTE 1 In the relevant lamp performance standards, the nominal wattage may still be indicated as "rated" wattage
(and the rated wattage as "objective" wat
...