Radio frequency and coaxial cable assemblies - Part 1: Generic specification - General requirements and test methods

Establishes uniform requirements for testing the electrical, mechanical and climatic properties of r.f. and coaxial cable assemblies composed of cables and connectors operating in the transverse electromagnetic mode (TEM). Tests are described in IEC 61196-1 and IEC 61169-1 respectively.

Konfektionierte Koaxial- und Hochfrequenzkabel - Teil 1: Fachgrundspezifikation - Allgemeine Anforderungen und Prüfverfahren

Ensembles de cordons coaxiaux et de cordons pour fréquences radioélectriques - Partie 1: Spécification générique - Généralités et méthodes d'essai

Fixe des prescriptions uniformes pour contrôler les propriétés électriques, mécaniques et climatiques des ensembles de cordons coaxiaux et de cordons pour fréquences radioélectriques composés de câbles et de connecteurs travaillant en mode électromagnétique transversal (TEM). Les essais sont respectivement décrits dans la CEI 61196-1 et la CEI 61169-1.

Radio frequency and coaxial assemblies - Part 1: Generic specification - General requirements and test methods (IEC 60966-1:1999)

General Information

Status
Withdrawn
Publication Date
01-Jun-1999
Withdrawal Date
30-Apr-2002
Drafting Committee
Parallel Committee
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
15-Mar-2022
Completion Date
15-Mar-2022

Relations

Buy Standard

Standard
EN 60966-1:2001
English language
59 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Radio frequency and coaxial assemblies - Part 1: Generic specification - General requirements and test methods (IEC 60966-1:1999)Konfektionierte Koaxial- und Hochfrequenzkabel -- Teil 1: Fachgrundspezifikation - Allgemeine Anforderungen und PrüfverfahrenEnsembles de cordons coaxiaux et de cordons pour fréquences radioélectriques -- Partie 1: Spécification générique - Généralités et méthodes d'essaiRadio frequency and coaxial cable assemblies -- Part 1: Generic specification - General requirements and test methods33.120.10Koaksialni kabli. ValovodiCoaxial cables. WaveguidesICS:Ta slovenski standard je istoveten z:EN 60966-1:1999SIST EN 60966-1:2001en01-februar-2001SIST EN 60966-1:2001SLOVENSKI
STANDARDSIST EN 60966-1:19961DGRPHãþD

NORMEINTERNATIONALECEIIECINTERNATIONALSTANDARD60966-1QC 140000Deuxième éditionSecond edition1999-04Ensembles de cordons coaxiaux et de cordonspour fréquences radioélectriques –Partie 1:Spécification générique –Généralités et méthodes d'essaiRadio frequency and coaxial cable assemblies –Part 1:Generic specification –General requirements and test methods Commission Electrotechnique Internationale International Electrotechnical CommissionPour prix, voir catalogue en vigueurFor price, see current catalogueÓ IEC 1999
Droits de reproduction réservés
¾
Copyright - all rights reservedAucune partie de cette publication ne peut être reproduite niutilisée sous quelque forme que ce soit et par aucun procédé,électronique ou mécanique, y compris la photo-copie et lesmicrofilms, sans l'accord écrit de l'éditeur.No part of this publication may be reproduced or utilized inany form or by any means, electronic or mechanical,including photocopying and microfilm, without permission inwriting from the publisher.International Electrotechnical Commission 3, rue de Varembé
Geneva, SwitzerlandTelefax: +41 22 919 0300 e-mail: inmail@iec.ch
IEC web site
http://www.iec.chCODE PRIXPRICE CODE XASIST EN 60966-1:2001

60966-1 © IEC:1999– 3 –CONTENTSPageFOREWORD.11Clause1Scope.132Normative references.133Definitions.154Design and manufacturing requirements.194.1Cable design and construction.194.2Connector design and construction.194.3Outline and interface dimensions.195Workmanship, marking and packaging.195.1Workmanship.195.2Marking.215.3End caps.215.4Packaging and labelling.216Quality assessment.217Test methods – General.217.1Standard atmospheric conditions for testing.217.2Visual inspection.217.3Dimensions inspection.218Electrical tests.238.1Reflection properties.238.2Uniformity of impedance.258.3Insertion loss.258.4Insertion loss stability.278.5Propagation time.278.6Stability of electrical length.278.7Phase difference.338.8Phase variation with temperature.358.9Screening effectiveness.358.10Voltage proof.378.11Insulation resistance.378.12Inner and outer conductor continuity.398.13Void.398.14Power rating.398.15Intermodulation level measurement.41SIST EN 60966-1:2001

60966-1 © IEC:1999– 5 –ClausePage9Mechanical robustness tests.419.1Tensile.419.2Flexure.419.3Flexing endurance.439.4Cable assembly crushing.459.5Torque.479.6Multiple bending.499.7Abrasion test of cable assembly.519.8Vibrations, shocks and impact.519.9Mechanical endurance.5110Environmental tests.5110.1Recommended severities.5110.2Vibration, bumps and shock.5110.3Climatic sequence.5110.4Damp heat, steady state.5310.5Rapid change of temperature.5310.6Solvents and contaminating fluids.5510.7Water immersion.5510.8Salt mist and sulphur dioxide tests.5510.9Dust tests.5710.10Flammability.6111Specialized test methods.6312Test schedules.63Annex A (normative)
Test methods for insertion loss determination.65A.1Purpose.65A.2Test methods.65A.2.1Test method 1 .65A.2.2Test method 2 .69A.2.3Test method 3.71A.3Correction for characteristic impedance differences.75Annex B (informative)
Measuring methods for propagation time.77B.1Resonance method for propagation time measurement.77B.2Time domaine method for propagation time measurement.79Annex C (informative)
Measurement method for screening effectiveness.81C.1Introduction.81C.2Test method.83Annex D (informative)
Recommended severities for environmental tests.87D.1Introduction to the relationship between environmental conditionsand test severities.87D.1.1General.87D.1.2Environmental conditions.87D.1.3Environmental testing.87SIST EN 60966-1:2001

60966-1 © IEC:1999– 7 –AnnexesPageD.2Severities for environmental testing.89D.2.1Vibration.89D.2.2Bump.91D.2.3Shock.91D.2.4Climatic sequence.93D.2.5Damp heat, steady state.93D.2.6Rapid change of temperature.93D.2.7Salt mist.93D.2.8Sulphur dioxide test.93D.2.9Dust test.93Annex E (normative)
Quality assessment.95E.1Object.95E.2General.95E.2.1Related documents.95E.2.2Standards and preferred values.95E.2.3Marking of the cable assembly and packaging.95E.2.4Terminology.97E.3Quality assessment procedures.97E.3.1Procedures for qualification approval.97E.3.2Procedures for capability approval.99E.3.3Quality conformance inspection.101E.4Capability manual and approval.103E.4.1Responsibilities.103E.4.2Contents of the capability manual.105E.4.3Criteria for capability limits.107TablesD.1Relationship between displacement and acceleration.91D.2Relationship between peak acceleration and velocity change.91E.1Example of capability limits for cable assemblies.107E.2Example of capability limits for flexible cables.107E.3Example of capability limits for connectors.107E.4Example of flow chart.109Figures1Bending test: U shape assembly.292Bending test: straight assembly.313Twisting test: U shape assembly.334Fixture for cable assembly flexu
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.