General Information

Abstract

This document is applicable to safety-related electronic systems (including subsystems and equipment) for railway signalling applications. This document applies to generic systems (i.e. generic products or systems defining a class of applications), as well as to systems for specific applications. The scope of this document and its relationship with other CENELEC standards are shown in Figure 1. This document is applicable only to the functional safety of systems. It does not deal with other aspects of safety such as occupational health and safety of personnel or potential threats created by the technology regardless of their intended functions (e.g. presence of sharp edges, presence of electric voltage, presence of combustible material). Cybersecurity aspects of functional safety are addressed only to the extent consistent with the application of the relevant standards, where needed. This document applies to all the phases of the life cycle of a safety-related electronic system, focusing in particular on phases from 4 (specification of system requirements) to 10 (system acceptance) as defined in EN 50126 1:2017. Requirements for systems which are not related to safety are outside the scope of this document. This document is not necessarily applicable to systems, subsystems or equipment which had already been accepted prior to the date of withdrawal (dow) of the standards conflicting with this document. However, so far as reasonably practicable, it is applicable to modifications and extensions to such systems, subsystems and equipment. NOTE In the case of partial modifications, it can happen that the system can no longer be declared compliant with a single version of the standard, meaning that the modified part will be compliant with the current version and the unmodified parts will be compliant with the previous version. This document is primarily applicable to systems, subsystems or equipment which have been specifically designed and manufactured for railway signalling applications. It is also applicable, to the extent of 6.2, to general-purpose or industrial equipment (e.g. power supplies, display screens, or other commercial off the shelf items) which is procured for use as part of a safety-related electronic system. This document is aimed at railway duty holders, railway suppliers, and assessors as well as at safety authorities, although it does not define an approval process to be applied by the safety authorities. Figure 1 - Scope of the main CENELEC railway application standards

Status
Published
Publication Date
14-May-2026
Current Stage
6060 - Document made available - Publishing
Start Date
15-May-2026
Due Date
25-Jun-2025
Completion Date
15-May-2026

Buy Documents

Standard

EN 50129:2026

English language (140 pages)
Preview
Preview
e-Library read for
1 day

Overview

EN 50129:2026 is a key CENELEC standard for the railway sector, focusing on the safety-related electronic systems used in railway signalling. Published by the European Committee for Electrotechnical Standardization (CLC), this standard outlines functional safety requirements for electronic systems, subsystems, and equipment within railway signalling applications. EN 50129:2026 applies to both generic products or systems and specific applications throughout the system lifecycle-from specification through to system acceptance.

The standard primarily targets functional safety. It covers requirements relating to hardware and software integration but does not address other safety aspects such as occupational health and safety risks not linked to system function or non-safety-related technology threats. EN 50129:2026 also touches on cybersecurity, though only as it relates to functional safety and in conjunction with other relevant standards (e.g., EN 50159, CLC/TS 50701).

Its goal is to foster harmonization and facilitate the cross-acceptance of safety approvals across European railway infrastructure, supporting safety authorities, duty holders, suppliers, and assessors.

Key Topics

  • Functional Safety Requirements
    Focuses on electronic systems directly tied to railway signalling safety, including detailed frameworks for developing, verifying, and validating safety-related properties.

  • System Lifecycle Phases
    Applies primarily from requirements specification (phase 4) through system acceptance (phase 10), as defined in related CENELEC standards, ensuring consistent safety management throughout the lifecycle.

  • Quality and Safety Management
    Emphasizes organizational processes for managing quality and safety-including safety planning, hazard logging, safety verification, validation, and independent safety assessment.

  • Use of Pre-existing and COTS Equipment
    Outlines provisions for incorporating commercial off-the-shelf (COTS) and pre-existing items into safety-related electronic systems, maintaining safety integrity.

  • Safety Case Structuring
    Describes the necessary documentary evidence to demonstrate system safety, supporting the acceptance and deployment of signalling solutions.

  • Modification, Maintenance, and Decommissioning
    Details requirements for updates, retrofits, and end-of-life management to ensure sustained system safety and compliance.

Applications

EN 50129:2026 is widely applied in the design, development, and approval of:

  • Train control and signalling equipment
    Ensures vital systems responsible for routing, train detection, and safety interlocks comply with rigorous safety standards.

  • Level crossing protection
    Applies to systems protecting road/rail intersections, guaranteeing electronic safety integrity.

  • Interlocking and control centers
    Supports control systems managing route setting and movement authorities with robust functional safety management.

  • On-board and trackside safety systems
    Governs the integration, qualification, verification, and validation of electronic safety subsystems, including adoption of suitable tools and techniques for hazard detection and fail-safe response.

The standard is used by suppliers, system integrators, railway operators, and independent assessors for project development, tendering, cross-acceptance, and regulatory compliance. It supports modifications, expansions, and upgrades to existing infrastructure-ensuring continued conformity as technologies evolve.

Related Standards

EN 50129:2026 is closely linked with several other CENELEC and international railway standards, including:

  • EN 50126-1/2: RAMS process and approach to overall system reliability, availability, maintainability, and safety.
  • EN 50124-1: Insulation coordination for railway applications.
  • EN 50125-1/3: Environmental conditions for rolling stock and signalling equipment.
  • EN 50159: Safety-related communication in transmission systems.
  • EN 50716: Software development requirements for railway applications.
  • CLC/TS 50701: Cybersecurity for the railway domain.
  • EN 61508 series: Generic standards for functional safety of electrical/electronic/programmable safety-related systems.

By harmonizing these standards, EN 50129:2026 provides a robust framework for functional safety in railway signalling, ensuring the safe integration and operation of advanced electronic systems across European rail networks.

Keywords: EN 50129:2026, railway signalling safety, electronic systems, functional safety, CENELEC, safety case, railway applications, system lifecycle, RAMS, cross-acceptance, signalling standards, railway safety standards.

Relations

Effective Date
14-Feb-2023
Effective Date
14-Feb-2023
Effective Date
19-May-2026
Effective Date
19-May-2026
Effective Date
19-May-2026
Effective Date
19-May-2026
Effective Date
19-May-2026
Effective Date
19-May-2026
Effective Date
19-May-2026
Effective Date
19-May-2026
Effective Date
19-May-2026
Effective Date
19-May-2026
Effective Date
19-May-2026
Effective Date
19-May-2026

Buy Documents

Standard

EN 50129:2026

English language (140 pages)
Preview
Preview
e-Library read for
1 day

Get Certified

Connect with accredited certification bodies for this standard

Zavod za gradbeništvo Slovenije (ZAG) - Inšpekcija

ZAG inspection body for construction products, structures, and materials.

SA Slovenia Verified

Sponsored listings

Frequently Asked Questions

EN 50129:2026 is a standard published by CLC. Its full title is "Railway Application - Communication, signalling and processing system - Safety related electronic systems for signalling". This standard covers: This document is applicable to safety-related electronic systems (including subsystems and equipment) for railway signalling applications. This document applies to generic systems (i.e. generic products or systems defining a class of applications), as well as to systems for specific applications. The scope of this document and its relationship with other CENELEC standards are shown in Figure 1. This document is applicable only to the functional safety of systems. It does not deal with other aspects of safety such as occupational health and safety of personnel or potential threats created by the technology regardless of their intended functions (e.g. presence of sharp edges, presence of electric voltage, presence of combustible material). Cybersecurity aspects of functional safety are addressed only to the extent consistent with the application of the relevant standards, where needed. This document applies to all the phases of the life cycle of a safety-related electronic system, focusing in particular on phases from 4 (specification of system requirements) to 10 (system acceptance) as defined in EN 50126 1:2017. Requirements for systems which are not related to safety are outside the scope of this document. This document is not necessarily applicable to systems, subsystems or equipment which had already been accepted prior to the date of withdrawal (dow) of the standards conflicting with this document. However, so far as reasonably practicable, it is applicable to modifications and extensions to such systems, subsystems and equipment. NOTE In the case of partial modifications, it can happen that the system can no longer be declared compliant with a single version of the standard, meaning that the modified part will be compliant with the current version and the unmodified parts will be compliant with the previous version. This document is primarily applicable to systems, subsystems or equipment which have been specifically designed and manufactured for railway signalling applications. It is also applicable, to the extent of 6.2, to general-purpose or industrial equipment (e.g. power supplies, display screens, or other commercial off the shelf items) which is procured for use as part of a safety-related electronic system. This document is aimed at railway duty holders, railway suppliers, and assessors as well as at safety authorities, although it does not define an approval process to be applied by the safety authorities. Figure 1 - Scope of the main CENELEC railway application standards

This document is applicable to safety-related electronic systems (including subsystems and equipment) for railway signalling applications. This document applies to generic systems (i.e. generic products or systems defining a class of applications), as well as to systems for specific applications. The scope of this document and its relationship with other CENELEC standards are shown in Figure 1. This document is applicable only to the functional safety of systems. It does not deal with other aspects of safety such as occupational health and safety of personnel or potential threats created by the technology regardless of their intended functions (e.g. presence of sharp edges, presence of electric voltage, presence of combustible material). Cybersecurity aspects of functional safety are addressed only to the extent consistent with the application of the relevant standards, where needed. This document applies to all the phases of the life cycle of a safety-related electronic system, focusing in particular on phases from 4 (specification of system requirements) to 10 (system acceptance) as defined in EN 50126 1:2017. Requirements for systems which are not related to safety are outside the scope of this document. This document is not necessarily applicable to systems, subsystems or equipment which had already been accepted prior to the date of withdrawal (dow) of the standards conflicting with this document. However, so far as reasonably practicable, it is applicable to modifications and extensions to such systems, subsystems and equipment. NOTE In the case of partial modifications, it can happen that the system can no longer be declared compliant with a single version of the standard, meaning that the modified part will be compliant with the current version and the unmodified parts will be compliant with the previous version. This document is primarily applicable to systems, subsystems or equipment which have been specifically designed and manufactured for railway signalling applications. It is also applicable, to the extent of 6.2, to general-purpose or industrial equipment (e.g. power supplies, display screens, or other commercial off the shelf items) which is procured for use as part of a safety-related electronic system. This document is aimed at railway duty holders, railway suppliers, and assessors as well as at safety authorities, although it does not define an approval process to be applied by the safety authorities. Figure 1 - Scope of the main CENELEC railway application standards

EN 50129:2026 is classified under the following ICS (International Classification for Standards) categories: 93.100 - Construction of railways. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 50129:2026 has the following relationships with other standards: It is inter standard links to EN 50129:2018/AC:2019-04, EN 50129:2018, EN 16207:2014+A1:2019, EN 50617-2:2015, EN 15595:2018+A1:2023, EN 15595:2018, EN 17168:2021, EN 15437-2:2012, CLC/TR 50451:2007, EN 16704-2-1:2016, CLC/TR 50126-2:2007, EN 50617-1:2015, EN 50556:2018, EN 16207:2014. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 50129:2026 is associated with the following European legislation: EU Directives/Regulations: 2016/797/EU; Standardization Mandates: M/483. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

EN 50129:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-oktober-2026
Nadomešča:
SIST EN 50129:2019
SIST EN 50129:2019/AC:2019
Železniške naprave - Komunikacijski, signalni in procesni sistemi - Signalno-
varnostni elektronski sistemi
Railway Application - Communication, signalling and processing system - Safety related
electronic systems for signalling
Bahnanwendungen - Telekommunikationstechnik, Signaltechnik und
Datenverarbeitungssysteme - Sicherheitsrelevante elektronische Systeme für
Signaltechnik
Applications ferroviaires - Systèmes de signalisation, de télécommunication et de
traitement - Systèmes électroniques de sécurité pour la signalisation
Ta slovenski standard je istoveten z: EN 50129:2026
ICS:
35.240.60 Uporabniške rešitve IT v IT applications in transport
prometu
45.020 Železniška tehnika na Railway engineering in
splošno general
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN 50129
NORME EUROPÉENNE
EUROPÄISCHE NORM May 2026
ICS 93.100 Supersedes EN 50129:2018; EN 50129:2018/AC:2019-04
English Version
Railway Application - Communication, signalling and processing
system - Safety related electronic systems for signalling
Applications ferroviaires - Systèmes de signalisation, de Bahnanwendungen - Telekommunikationstechnik,
télécommunications et de traitement - Systèmes Signaltechnik und Datenverarbeitungssysteme -
électroniques de sécurité pour la signalisation Sicherheitsbezogene elektronische Systeme für
Signaltechnik
This European Standard was approved by CENELEC on 2026-04-20. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Türkiye and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2026 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 50129:2026 E
Contents Page
European foreword . 4
Introduction . 5
1 Scope . 6
2 Normative references . 7
3 Terms, definitions and abbreviated terms . 7
3.1 Terms and definitions . 7
3.2 Abbreviated terms . 18
4 Overall framework of this document . 19
5 Requirements for developing safety-related electronic systems . 21
5.1 General . 21
5.2 The quality management process . 21
5.3 The safety management process . 23
6 Requirements for elements following different life cycles . 35
6.1 General . 35
6.2 Use of pre-existing items . 35
6.3 Safety-related tools for electronic systems . 37
6.4 Physical security and cybersecurity . 39
7 The safety case: structure and content . 41
7.1 The safety case structure . 41
7.2 The technical safety report . 42
7.3 Generic and specific safety cases . 50
7.4 Provisions for the specific application safety case . 51
7.5 Dependencies between safety cases . 52
7.6 Safety report for Basic Integrity functions . 52
8 System safety acceptance and subsequent phases . 53
8.1 System safety acceptance process . 53
8.2 Operation, maintenance and performance monitoring . 57
8.3 Modification and retrofit . 57
8.4 Decommissioning and disposal . 57
Annex A (normative) Safety Integrity Levels . 58
A.1 General . 58
A.2 Safety requirements . 58
A.3 Safety Integrity . 59
A.4 Determination of Safety Integrity requirements . 60
A.5 Allocation of SILs . 70
Annex B (normative) Management of faults for safety-related functions . 73
B.1 General . 73
B.2 General concepts . 73
B.3 Effects of faults . 75
Annex C (normative) Identification of hardware component failure modes . 89
C.1 General . 89
C.2 General procedure . 89
C.3 Procedure for integrated circuits . 89
C.4 Procedure for components with inherent physical properties . 90
C.5 General provisions concerning component failure modes . 90
Annex D (informative) Example of THR/TFFR/FR apportionment and SIL allocation . 108
Annex E (normative) Techniques and measures for the avoidance of systematic faults and the
control of random and systematic faults . 110
E.1 General . 110
E.2 Tables of techniques and measures . 112
Annex F (informative) Guidance on User Programmable Integrated Circuits . 120
F.1 General . 120
F.2 UPIC life cycle . 121
F.3 Detailed technical requirements for UPIC. 126
Annex G (informative) Changes in this document compared to EN 50129:2018. 136
Bibliography . 139

European foreword
This document (EN 50129:2026) has been prepared by CLC/SC 9XA “Communication, signalling and
processing systems” of CLC/TC 9X “Electrical and electronic applications for railways”.
The following dates are fixed:
• latest date by which this document has to be (dop) 2027-05-31
implemented at national level by publication of
an identical national standard or by
endorsement
• latest date by which the national standards (dow) 2029-05-31
conflicting with this document have to be
withdrawn
This document supersedes EN 50129:2018 and all of its amendments and corrigenda (if any).
Requirements and guidance have been added on the following topics:
— Clause 5: update of requirements and guidance on safety qualification tests;
— Clause 6: update of requirements and guidance on safety-related tools, cybersecurity;
— Clause 7: update of requirements and guidance on cybersecurity; a significant portion of 7.2 has been
incorporated into Table 2;
— Annex C: update of insulation coordination requirements for better readability;
— Annex E: a new column has been added for Basic Integrity.
A more detailed comparison of changes between EN 50129:2018 and this document can be found in
Annex G.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
Any feedback and questions on this document should be directed to the users’ national committee. A
complete listing of these bodies can be found on the CENELEC website.
Introduction
This document defines requirements for the development and acceptance of safety-related electronic systems
in the railway signalling field.
Safety-related electronic systems for signalling include hardware and software aspects. To develop complete
safety-related systems, both aspects need to be taken into account throughout the whole life cycle of the
system. The requirements for the overall safety-related electronic system and for its hardware aspects are
defined in this document. Other requirements are defined in associated CENELEC standards.
General requirements for a consistent approach to the management of RAMS are given in EN 50126-1:2017
and EN 50126-2:2017. For safety-related systems which include software, additional requirements are defined
in EN 50716:2023. Additional requirements for safety-related communication are defined in EN 50159:2010.
Cyberattacks can affect the safety of a system, but this document does not specify the cybersecurity
requirements for the development, implementation, maintenance and operation of security policies, services,
or systems. For cybersecurity, appropriate standards apply.
NOTE ISO/IEC and CEN/CENELEC publications that address cybersecurity in depth are EN ISO/IEC 27000 and
ISO/IEC TR 19791. In the field of industrial automation and control systems, the EN IEC 62443 series have been defined.
CLC/TS 50701:2023 addresses cybersecurity for the railway domain and was derived from the EN IEC 62443 series.
The aim of European railway duty holders and of European railway industry is to develop compatible railway
systems based on common standards. Therefore cross-acceptance of safety approvals for systems,
subsystems or equipment by the different national railway duty holders is needed. This document is the
common European base for safety acceptance of electronic systems for railway signalling applications.
Cross-acceptance is aimed at the acceptance of generic products or generic applications that can be used for
a number of different specific applications, and not at the acceptance of any single specific application. Public
procurement within the European Community concerning safety-related electronic systems for railway
signalling applications will refer to this document.
This document is concerned with the evidence to be presented for the acceptance of safety-related systems.
However, it specifies not only those life cycle activities which need to be completed before the system
acceptance phase, but also the additional planned activities to be carried out afterwards. In this way, safety
justification will cover the whole life cycle.
This document is concerned with what evidence is to be presented. Except where considered appropriate, it
does not specify who carries out the necessary work. The necessary work can be carried out by different
people, in different circumstances or organisational structures, provided that independence of roles is
respected.
This document consists of Clause 1 to Clause 8, which form the main part, and Annexes A, B, C, D, E, F and
G . The requirements defined in Clause 5 to Clause 8 and in Annexes A, B, C and E are normative, whilst
Annexes D, F and G are informative.
This document is in line with, and contains references to:
— EN 50126-1:2017, Railway Applications — The Specification and Demonstration of Reliability,
Availability, Maintainability and Safety (RAMS) — Part 1: Generic RAMS Process,
— EN 50126-2:2017, Railway Applications — The Specification and Demonstration of Reliability,
Availability, Maintainability and Safety (RAMS) — Part 2: Systems Approach to Safety.
This document is based on the system life cycle described in EN 50126-1:2017, EN 50126-2:2017 and is in
line with the EN 61508 series. EN 50126-1:2017, EN 50126-2:2017, EN 50716:2023 and this document
comprise the railway sector equivalent of the EN 61508 series so far as Railway Communication, Signalling
and Processing Systems are concerned. Given that compliance with these documents has been
demonstrated, there are no requirements in this document for further evaluation of compliance with the
EN 61508 series.
1 Scope
This document is applicable to safety-related electronic systems (including subsystems and equipment) for
railway signalling applications.
This document applies to generic systems (i.e. generic products or systems defining a class of applications),
as well as to systems for specific applications.
The scope of this document and its relationship with other CENELEC standards are shown in Figure 1.
This document is applicable only to the functional safety of systems. It does not deal with other aspects of
safety such as occupational health and safety of personnel or potential threats created by the technology
regardless of their intended functions (e.g. presence of sharp edges, presence of electric voltage, presence of
combustible material). Cybersecurity aspects of functional safety are addressed only to the extent consistent
with the application of the relevant standards, where needed.
This document applies to all the phases of the life cycle of a safety-related electronic system, focusing in
particular on phases from 4 (specification of system requirements) to 10 (system acceptance) as defined in
EN 50126-1:2017.
Requirements for systems which are not related to safety are outside the scope of this document.
This document is not necessarily applicable to systems, subsystems or equipment which had already been
accepted prior to the date of withdrawal (dow) of the standards conflicting with this document. However, so far
as reasonably practicable, it is applicable to modifications and extensions to such systems, subsystems and
equipment.
NOTE In the case of partial modifications, it can happen that the system can no longer be declared compliant with a
single version of the standard, meaning that the modified part will be compliant with the current version and the unmodified
parts will be compliant with the previous version.
This document is primarily applicable to systems, subsystems or equipment which have been specifically
designed and manufactured for railway signalling applications. It is also applicable, to the extent of 6.2, to
general-purpose or industrial equipment (e.g. power supplies, display screens, or other commercial off the
shelf items) which is procured for use as part of a safety-related electronic system.
This document is aimed at railway duty holders, railway suppliers, and assessors as well as at safety
authorities, although it does not define an approval process to be applied by the safety authorities.

Figure 1 — Scope of the main CENELEC railway application standards
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes
requirements of this document. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
EN 50124-1:2017, Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances
and creepage distances for all electrical and electronic equipment
EN 50125-1:2014, Railway applications - Environmental conditions for equipment - Part 1: Rolling stock and
on-board equipment
EN 50125-3:2003, Railway applications - Environmental conditions for equipment - Part 3: Equipment for
signalling and telecommunications
EN 50126-1:2017, Railway Applications - The Specification and Demonstration of Reliability, Availability,
Maintainability and Safety (RAMS) - Part 1: Generic RAMS Process
EN 50126-2:2017, Railway Applications - The Specification and Demonstration of Reliability, Availability,
Maintainability and Safety (RAMS) - Part 2: Systems Approach to Safety
EN 50159:2010, Railway applications - Communication, signalling and processing systems - Safety-related
communication in transmission systems
EN 50716:2023, Railway Applications - Requirements for software development
EN IEC 60664-1:2020, Insulation coordination for equipment within low-voltage supply systems - Part 1:
Principles, requirements and tests (IEC 60664-1:2020)
3 Terms, definitions and abbreviated terms
3.1 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https://www.iso.org/obp/
— IEC Electropedia: available at https://www.electropedia.org/
3.1.1
accident
unintended event or series of events that results in harm
[SOURCE: IEC 60050-821:2017, 821-12-02, modified – “that results in death, injury, loss of a system or
service, or environmental damage” has been replaced with “that results in harm”.]

As impacted by EN 50125-3/2003/corrigendum May 2010.
As impacted by EN 50126-1:2017/A1:2024.
As impacted by EN 50126-2:2017/A1:2024.
As impacted by EN 50159:2010/A1:2020.
As impacted by EN IEC 60664-1:2020/AC:2020-12 and EN IEC 60664-1:2020/A1:2025.
3.1.2
audit
systematic, independent, documented process for obtaining records, statements of fact or other relevant
information and assessing them objectively to determine the extent to which specified requirements are
fulfilled
Note 1 to entry: Whilst “audit” applies to management systems, “assessment” applies to conformity assessment bodies
as well as more generally.
[SOURCE: IEC 60050-902:2013, 902-03-04]
3.1.3
basic insulation
insulation that provides basic protection
Note 1 to entry: This concept does not apply to insulation used exclusively for functional purposes.
[SOURCE: IEC 60050-195:2021, 195-06-06]
3.1.4
Basic Integrity
integrity attribute for a safety-related function with a tolerable functional failure rate equal to, or higher than
−5 −1
(less demanding), 10 h ; or for a non-safety-related function
Note 1 to entry: In this document Basic Integrity requirements relate only to safety-related functions. If a non-safety-
related function has been given Basic Integrity requirements on the basis of the process described in EN 50126-2:2017,
no additional requirements are defined in this document.
[SOURCE: EN 50126-1:2017, 3.7, modified – Note 1 to entry has been added.]
3.1.5
causal analysis
analysis of the reasons how and why a particular hazard can come into existence
[SOURCE: IEC 60050-821:2017, 821-12-07]
3.1.6
common cause failures
failures of multiple items, which would otherwise be considered independent of one another, resulting from a
single cause
[SOURCE: IEC 60050-192:2015, 192-03-18, modified – Notes 1 and 2 to entry have been deleted.]
3.1.7
configuration
structuring and interconnection of the hardware and software of a system for its intended application
[SOURCE: IEC 60050-821:2017, 821-12-12]
3.1.8
consequence analysis
analysis of events which are likely to happen after a hazard has occurred
[SOURCE: IEC 60050-821:2017, 821-12-14]
3.1.9
cross-acceptance
status achieved by a product that has been accepted by one authority to the relevant standards and is
acceptable to other authorities without the necessity for further assessment
[SOURCE: IEC 60050-821:2017, 821-12-15]
3.1.10
cybersecurity
actions required to preclude unauthorized use of, denial of service to, modifications to, disclosure of, or
damage to systems or informational assets
Note 1 to entry: Cybersecurity includes the concepts of identification, authentication, accountability, authorization,
availability, and privacy.
Note 2 to entry: It is recognized that the term “cybersecurity” has a broader meaning in other standards and guidance,
often including non-malevolent threats, human errors, and protection against natural disasters. Those aspects, except
human errors degrading security controls, are not included in this document.
3.1.11
DC fault model
fault category that includes the following failure modes: stuck-at faults, stuck-open, open or high impedance
outputs and short circuit between signal lines, and for integrated circuits short circuit between any two
connections (pins)
3.1.12
design
activity applied in order to analyse and transform specified requirements into acceptable solutions
[SOURCE: IEC 60050-821:2017, 821-12-16, modified – The end of the definition “design solutions which have
the required Safety Integrity level” has been replaced with “solutions”.]
3.1.13
diversity
existence of two or more different ways or means of achieving a specified objective
Note 1 to entry: Diversity is specifically provided as a defence against common cause failures. It can be achieved by
providing systems that are physically different from each other or by functional diversity, where similar systems achieve
the specified objective in different ways.
[SOURCE: IEC 60050-395:2014, 395-07-115, modified – The supplementary information has been moved to
a new Note 1 to entry, which replaces the original Note 1 to entry.]
3.1.14
double insulation
insulation comprising both basic insulation and supplementary insulation
Note 1 to entry: In double insulation, each layer shall be able to be tested or analysed separately. In particular:
— the clearance distance shall be the basic distance. In addition, also the supplementary solid layer shall be
dimensioned taking into account the same rated impulse voltage (U ).
Ni
— the creepage distance shall be the sum of basic and supplementary distances. The basic distance shall be evaluated
against the rated insulation voltage (U ). In addition, also the supplementary distance shall be evaluated against the
Nm
same UNm . The UNm shall not be apportioned.
Note 2 to entry: With respect to Note 1 to entry, for definition of rated insulation voltage and rated impulse voltage, see
EN 50124-1:2017. Similar definitions can also be found in EN IEC 60664-1:2020.
[SOURCE: IEC 60050-195:2021, 195-06-08 modified – Notes to entry 1 and 2 have been added.]
3.1.15
electronic component
hardware component
electronic device that cannot be taken apart without destruction or impairment of its intended use
EXAMPLE Resistors, capacitors, diodes, integrated circuits, hybrids, application specific integrated circuits, wound
components and relays.
[SOURCE: IEC 60050-904:2014, 904-01-09, modified – The preferred terms “electronic part” and “piece part”
have been deleted and a new preferred term “hardware component” has been added.]
3.1.16
equipment
single apparatus or set of devices or apparatuses, or the set of main devices of an installation, or all devices
necessary to perform a specific task
Note 1 to entry: Examples of equipment are a power transformer, the equipment of a substation, measuring equipment.
[SOURCE: IEC 60050-151:2001, 151-11-25]
3.1.17
error
discrepancy between a computed, observed or measured value or condition and the true, specified or
theoretically correct value or condition
Note 1 to entry: An error can be caused by a faulty item, e.g. a computing error made by faulty computer equipment.
Note 2 to entry: A human error can be seen as a human action or inaction that can produce an unintended result.
[SOURCE: IEC 60050-192:2015, 192-03-02, modified – Notes 1 and 2 to entry have been modified.]
3.1.18
fail-safe
able to enter or remain in a safe state in the event of a failure
[SOURCE: IEC 60050-821:2017, 821-01-10]
3.1.19
failure
loss of ability to perform as required
Note 1 to entry: Qualifiers, such as catastrophic, critical, major, minor, marginal and insignificant, can be used to
categorize failures according to the severity of consequences, the choice and definitions of severity criteria depending
upon the field of application.
Note 2 to entry: Qualifiers, such as misuse, mishandling and weakness, can be used to categorize failures according to
the cause of failure.
Note 3 to entry: “Failure” is an event, as distinguished from “fault”, which is a state.
[SOURCE: IEC 60050-821:2017, 821-11-19, modified – “may” has been changed to “can” in notes to entry 1
and 2. Note 3 to entry has been added.]
3.1.20
failure rate
limit of the ratio of the conditional probability that the instant of time, T, of a failure of a product falls within a
given time interval (t, t + Δt) and the duration of this interval, Δt, when Δt tends towards zero, given that the
item is in an up state at the start of the time interval
Note 1 to entry: For applications where distance travelled or number of cycles of operation is more relevant than time,
the unit of time can be replaced by the unit of distance or cycles, as appropriate.
Note 2 to entry: The term “failure rate” is often used in the sense of “mean failure rate” defined in IEV 192-05-07.
[SOURCE: IEC 60050-821:2017, 821-12-21]
3.1.21
fault
abnormal condition that could lead to an error in a system
Note 1 to entry: A fault can be random or systematic.
[SOURCE: IEC 60050-821:2017, 821-11-20]
3.1.22
fault detection time
time interval between failure and detection of the resulting fault
[SOURCE: IEC 60050-192:2024, 192-07-11, modified – The deprecated term “undetected fault time” as well
as Figures 1 and 2 have been deleted.]
3.1.23
function
specified action or activity which can be performed by technical means or human beings and has
a defined output in response to a defined input
Note 1 to entry: A function can be specified or described without reference to the physical means of achieving it.
3.1.24
functional safety
part of the overall safety that depends on functional and physical units operating correctly in response to their
inputs
[SOURCE: IEC 60050-351:2013, 351-57-06, modified – Note 1 to entry has been deleted.]
3.1.25
harm
injury or damage to the health of people, or damage to property or the environment
[SOURCE: ISO/IEC Guide 51:2014, 3.1]
3.1.26
hazard
condition that can lead to an accident
Note 1 to entry: The equivalent definition in IEC 60050-903:2013, 903–01–02 refers to “harm” instead of “accident”.
Note 2 to entry: This means that there is at least one scenario in which the hazard, under credible circumstances, leads
to an accident.
3.1.27
hazard analysis
process of identifying hazards and analysing their causes, and the derivation of requirements to limit the
likelihood and consequences of hazards to a tolerable level
[SOURCE: IEC 60050-821:2017, 821-11-23]
3.1.28
hazard log
document in which hazards identified, decisions made, solutions adopted, and their implementation status are
recorded or referenced
[SOURCE: IEC 60050-821:2017, 821-12-27]
3.1.29
implementation
activity applied in order to transform the specified designs into their realization
[SOURCE: IEC 60050-821:2017, 821-12-29, modified – “physical realization” changed to “realization”.]
3.1.30
independence of roles
freedom from involvement in the same intellectual, commercial or management entity
3.1.31
independent safety assessment
process to determine whether a system or product meets the specified safety requirements and to form a
judgement as to whether the product is fit for its intended purpose in relation to safety
[SOURCE: EN 50126-1:2017, 3.33, modified – “the system/product” has been changed to “a system or
product”. Note 1 to entry has been deleted.]
3.1.32
maintenance
combination of all technical and management actions intended to retain an item in, or restore it to, a state in
which it can perform as required
Note 1 to entry: Management is assumed to include supervision activities.
[SOURCE: IEC 60050-192:2015, 192-06-01]
3.1.33
negation
enforcement of a safe state following detection of a hazardous fault
[SOURCE: IEC 60050-821:2017, 821-12-38]
3.1.34
negation time
time interval which begins when the existence of a fault is detected and ends when a safe state is enforced
[SOURCE: IEC 60050-821:2017, 821-12-39]
3.1.35
pre-existing item
item that already exists and that was not developed specifically for the current project
3.1.36
product
collection of elements, interconnected to form a system, a subsystem or an equipment, in a
manner which meets the specified requirements
[SOURCE: IEC 60050-821:2017, 821-12-40, modified — The specific use “in signalling” has been made more
general with “in railway”.]
3.1.37
railway duty holder
body with the overall accountability for operating a railway system within the legal framework
Note 1 to entry: Railway duty holder accountabilities for the overall system or its parts and life cycle activities are
sometimes split between one or more bodies or entities. For example:
— the owner(s) of one or more parts of the system assets and their purchasing agents;
— the operator of the system;
— the maintainer(s) of one or more parts of the system.
Note 2 to entry: Typically the railway duty holders are railway undertakings and the infrastructure managers. Such splits
are based on either statutory instruments or contractual agreements. Such responsibilities are defined at the earliest
stages of a system life cycle.
[SOURCE: EN 50126-1:2017, 3.48]
3.1.38
random failure integrity
degree to which a system is free from hazardous random faults
Note 1 to entry: This definition can be read as “integrity from failures due to random faults”.
[SOURCE: IEC 60050-821:2017, 821-12-45, modified – Note 1 to entry has been added.]
3.1.39
random fault
unpredictable occurrence of a fault
[SOURCE: IEC 60050-821:2017, 821-12-46]
3.1.40
redundancy
provision of more than one means for performing a function
[SOURCE: IEC 60050-192: 2015, 192-10-02, modified – Note 1 to entry has been deleted.]
3.1.41
reinforced insulation
insulation that provides a degree of protection against electric shock equivalent to double insulation
Note 1 to entry: Reinforced insulation can comprise several layers which cannot be tested singly as basic insulation or
supplementary insulation.
[SOURCE: IEC 60050-195:2021, 195-06-09]
3.1.42
reliability
ability to perform as required, without failure, for a given time interval, under given conditions
Note 1 to entry: The time interval duration can be expressed in units appropriate to the item concerned, e.g. calendar
time, operating cycles, distance run etc., and the units should always be clearly stated.
Note 2 to entry: Given conditions include aspects that affect reliability, such as: mode of operation, stress levels,
environmental conditions, and maintenance.
Note 3 to entry: Reliability can be quantified using measures defined in IEC 60050-192:2015, Section 192–05, Reliability
related concepts: measures.
[SOURCE: IEC 60050-192:2015, 192-01-24]
3.1.43
repair
direct action taken to effect restoration
Note 1 to entry: Repair includes fault localization (IEV 192-06-19), fault diagnosis (IEV 192-06-20), fault correction
(IEV 192-06-21), and function checkout (IEV 192-06-22).
[SOURCE: IEC 60050-192:2015, 192-06-14]
3.1.44
risk
combination of the frequency of occurrence of harm and the severity of that harm
[SOURCE: IEC 60050-351:2013, 351-57-03, modified — “probability” has been replaced with “frequency”.]
3.1.45
safe state
condition which continues to preserve safety
[SOURCE: IEC 60050-821:2017, 821-12-49]
3.1.46
safety
freedom from unacceptable risk
[SOURCE: IEC 60050-903:2013, 903-01-19]
3.1.47
safety acceptance
safety status given to a product by the final user
[SOURCE: IEC 60050-821:2017, 821-12-50]
3.1.48
safety approval
safety status given to a product by the requisite authority when the product has fulfilled a set of pre-
determined conditions
[SOURCE: IEC 60050-821:2017, 821-12-51]
3.1.49
safety authority
body responsible for delivering the authorization for the operation of the safety-related system
[SOURCE: IEC 60050-821:2017, 821-12-52]
3.1.50
safety case
documented demonstration that the product (e.g. a system, subsystem or equipment) complies with the
specified safety requirements
[SOURCE: IEC 60050-821:2017, 821-12-53]
3.1.51
safety function
function whose sole purpose is to ensure safety
Note 1 to entry: All safety functions are safety-related, but not vice versa.
Note 2 to entry: A safety function can contribute to one or more safety barriers. However, a safety barrier is not
necessarily implemented by a safety function.
[SOURCE: EN 50126−1:2017, 3.68, modified – Note 1 to entry has been simplified and “may” has been
changed to “can” in note 2 to entry.]
3.1.52
Safety Integrity
ability of a safety-related system or product to achieve its required safety-related functions under all the stated
conditions within a stated operational environment and within a stated duration
[SOURCE: IEC 60050-821:2017, 821-12-54, modified — “or product” has been added; “safety functions” has
been changed to “safety-related functions”.]
3.1.53
Safety Integrity Level
one of a number of defined discrete levels for specifying the Safety Integrity requirements of safety-related
functions to be allocated to the safety-related systems
Note 1 to entry: Safety Integrity Level with the highest figure has the highest level of Safety Integrity.
Note 2 to entry: It is not possible to allocate a Safety Integrity Level to safety-related processes or other measures. For
further explanations on SIL misuse, refer to EN 50126-2:2017, 10.2.12.
[SOURCE: IEC 60050-821:2017, 821-11-46, modified – “number which indicates the required degree of
confidence that a system will meet its specified safety functions with respect to systematic failures” has been
replaced with “one of a number of defined discrete levels for specifying the Safety Integrity requirements of
safety-related functions to be allocated to the safety-related systems”. Notes 1 and 2 to entry have been
added]
3.1.54
safety life cycle
additional series of activities carried out in conjunction with the system life cycle for safety-related systems
[SOURCE: IEC 60050-821:2017, 821-12-55]
3.1.55
safety plan
documented set of time scheduled activities, resources and events serving to implement the organization,
responsibilities, procedures, activities, capabilities and resources that together ensure that an item will satisfy
given safety requirements relevant to a given contract or project
[SOURCE: IEC 60050-821:2017, 821-12-57]
3.1.56
safety process
series of procedures that are followed to enable all safety requirements of a product to be identified and met
[SOURCE: IEC 60050-821:2017, 821-12-58]
3.1.57
safety-related
carries responsibility for safety
Note 1 to entry: A function, component, product, system, or procedure is called safety-related if at least one of its
properties is used in the safety argument for the system in which it is applied. These properties can be of functional or
non-functional nature.
[SOURCE: IEC 60050-821:2017, 821-01-73, modified – Note 1 to entry has been added.]
3.1.58
signalling system
system to ensure the safe movement of trains
Note 1 to entry: For the purposes of this document, railway signalling applications encompass all systems which control
and protect train movements by conveying instructions or warnings to trains or trackside systems. Where a signalling
system includes subsystems or equipment on board of the train, this document is intended to apply up to the interface with
the braking system, traction control system or other relevant train systems.
[SOURCE: IEC 60050-821:2017, 821-01-03, modified — The end of the definition “by means of one or more
of the following: lineside indications, wayside/onboard data exchange, indications given in the driver's cab”
has been omitted and Note 1 to entry has been added.]
3.1.59
solid insulation
solid insulating material, or a combination of solid insulating materials, placed between two conductive parts or
between a conductive part and a body part
EXAMPLE In the case of a printed board with a coating, solid insulation consists of the board itself as
well as the coating. In other cases, solid insulation consists of the encapsulating material
[SOURCE: IEC 60050-903:2013, 903-04-14]
3.1.60
stress profile
degree and number of external influences which a system can withstand whilst performing its required
functionality
[SOURCE: IEC 60050-821:2017, 821-12-65]
3.1.61
subsystem
part of a system, which is itself a system
[SOURCE: IEC 60050-192:2015, 192-01-04, modified – Note 1 to entry has been omitted.]
3.1.62
supplementary insulation
independent insulation applied in addition to basic insulation, that provides fault protection
[SOURCE: IEC 60050-195:2021, 195-06-07]
3.1.63
system
set of interrelated elements considered in a defined context as a whole and separated from their environment
[SOURCE: IEC 60050-351:2013, 351-42-08, modified — Notes to entry have been deleted.]
3.1.64
system life cycle
activities occurring during a given time interval that starts when a system is conceived and ends when the
system is no longer available for use, is decommissioned and is disposed of
[SOURCE: IEC 60050-821:2017, 821-12-66]
3.1.65
systematic failure integrity
degree to which a system is free from hazardous systematic faults
Note 1 to entry: This definition can be read as “integrity from failures due to systematic faults”, in analogy with
IEC 60050-821:2017, 821–12–46, where “random” is replaced by “systematic”.
[SOURCE: IEC 60050-821:2017, 821-12-68, modified — “unidentified hazardous errors and the causes
thereof” has been replaced with “hazardous systematic faults” and Note 1 to entry has been added.]
3.1.66
systematic fault,
inherent fault in the specification, design, construction, installation, operation or maintenance of a
system, subsystem or equipment
[SOURCE: IEC 60050-821:2017, 821-12-69]
3.1.67
technical safety report
documented technical evidence for the safety of the design of a system, subsystem or equipment
Note 1 to entry: The technical safety report is part of the safety case.
[SOURCE: IEC 60050-821:2017, 821-12-70, modified – Note 1 to entry has been adde
...