IEC 60364-4-41:1992/AMD2:1999
(Amendment)Amendment 2 - Electrical installations of buildings - Part 4: Protection for safety - Chapter 41: Protection against electric shock
Amendment 2 - Electrical installations of buildings - Part 4: Protection for safety - Chapter 41: Protection against electric shock
Amendement 2 - Installations électriques des bâtiments - Quatrième partie: Protection pour assurer la sécurité - Chapitre 41: Protection contre les chocs électriques
General Information
- Status
- Published
- Publication Date
- 22-Feb-1999
- Technical Committee
- TC 64 - Electrical installations and protection against electric shock
- Current Stage
- DELPUB - Deleted Publication
- Start Date
- 20-Aug-2001
- Completion Date
- 13-Feb-2026
Relations
- Effective Date
- 05-Sep-2023
- Effective Date
- 05-Sep-2023
Get Certified
Connect with accredited certification bodies for this standard

ICC Evaluation Service
Building products evaluation and certification.

NSF International
Global independent organization facilitating standards development and certification.

QAI Laboratories
Building and construction product testing and certification.
Sponsored listings
Frequently Asked Questions
IEC 60364-4-41:1992/AMD2:1999 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Amendment 2 - Electrical installations of buildings - Part 4: Protection for safety - Chapter 41: Protection against electric shock". This standard covers: Amendment 2 - Electrical installations of buildings - Part 4: Protection for safety - Chapter 41: Protection against electric shock
Amendment 2 - Electrical installations of buildings - Part 4: Protection for safety - Chapter 41: Protection against electric shock
IEC 60364-4-41:1992/AMD2:1999 is classified under the following ICS (International Classification for Standards) categories: 13.260 - Protection against electric shock. Live working; 91.140.50 - Electricity supply systems. The ICS classification helps identify the subject area and facilitates finding related standards.
IEC 60364-4-41:1992/AMD2:1999 has the following relationships with other standards: It is inter standard links to IEC 60364-4-41:1992, IEC 60364-4-41:2001. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
IEC 60364-4-41:1992/AMD2:1999 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
NORME CEI
INTERNATIONALE IEC
60364-4-41
INTERNATIONAL
STANDARD
AMENDEMENT 2
AMENDMENT 2
1999-02
PUBLICATION FONDAMENTALE DE SÉCURITÉ
BASIC SAFETY PUBLICATION
Amendement 2
Installations électriques des bâtiments –
Partie 4:
Protection pour assurer la sécurité –
Chapitre 41: Protection contre
les chocs électriques
Amendment 2
Electrical installations of buildings –
Part 4:
Protection for safety –
Chapter 41: Protection against electric shock
IEC 1999 Droits de reproduction réservés Copyright - all rights reserved
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http://www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
B
PRICE CODE
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue
– 2 – 60364-4-41 amend. 2 © CEI:1999
AVANT-PROPOS
Le présent amendement a été établi par le comité d'études 64 de la CEI: Installations
électriques des bâtiments.
Le texte de cet amendement est issu des documents suivants:
FDIS Rapport de vote
64/1045/FDIS 64/1064/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cet amendement.
___________
Page 14
411.1.5.2
Remplacer ce paragraphe par ce qui suit:
411.1.5.2 La protection contre les contacts directs, conformément à 411.1.5.1, n'est pas
nécessaire dans un bâtiment ou à l’extérieur de celui-ci si la liaison équipotentielle principale
est conforme à 413.1.2, si les masses des matériels TBTP sont reliées à la borne principale de
terre par un conducteur de protection et si la tension nominale n'est pas supérieure à:
– 25 V valeur efficace en courant alternatif ou 60 V en courant continu lisse si le matériel est
normalement utilisé dans des emplacements secs
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...