Electrical installations of buildings - Part 5-51: Selection and erection of electrical equipment - Common rules

Deals with the selection of equipment and its erection. It provides common rules for compliance with measures of protection for safety, requirements for proper functioning for intended use of the installation, and requirements appropriate to the external influences foreseen.

Installations électriques des bâtiments - Partie 5-51 : Choix et mise en oeuvre des matériels électriques - Règles communes

Traite du choix du matériel et de sa mise en uvre. Il doit permettre de satisfaire aux mesures de protection pour assurer la sécurité, aux prescriptions pour assurer un fonctionnement satisfaisant de l'installation pour l'utilisation prévue, et aux prescriptions appropriées aux conditions d'influences externes prévisibles.

General Information

Status
Published
Publication Date
16-Aug-2001
Current Stage
DELPUB - Deleted Publication
Start Date
14-Apr-2005
Completion Date
26-Oct-2025
Ref Project

Relations

Standard
IEC 60364-5-51:2001 - Electrical installations of buildings - Part 5-51: Selection and erection of electrical equipment - Common rules Released:8/17/2001 Isbn:2831858771
English and French language
77 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NORME CEI
INTERNATIONALE IEC
60364-5-51
INTERNATIONAL
Quatrième édition
STANDARD
Fourth edition
2001-08
Installations électriques des bâtiments –
Partie 5-51:
Choix et mise en œuvre des matériels électriques –
Règles communes
Electrical installations of buildings –
Part 5-51:
Selection and erection of electrical equipment –
Common rules
Numéro de référence
Reference number
CEI/IEC 60364-5-51:2001
Numérotation des publications Publication numbering

Depuis le 1er janvier 1997, les publications de la CEI As from 1 January 1997 all IEC publications are

sont numérotées à partir de 60000. Ainsi, la CEI 34-1 issued with a designation in the 60000 series. For
devient la CEI 60034-1. example, IEC 34-1 is now referred to as IEC 60034-1.

Editions consolidées Consolidated editions

Les versions consolidées de certaines publications de la The IEC is now publishing consolidated versions of its

CEI incorporant les amendements sont disponibles. Par publications. For example, edition numbers 1.0, 1.1
exemple, les numéros d’édition 1.0, 1.1 et 1.2 indiquent and 1.2 refer, respectively, to the base publication,
respectivement la publication de base, la publication de the base publication incorporating amendment 1 and

base incorporant l’amendement 1, et la publication de the base publication incorporating amendments 1
base incorporant les amendements 1 et 2. and 2.
Informations supplémentaires Further information on IEC publications
sur les publications de la CEI
Le contenu technique des publications de la CEI est The technical content of IEC publications is kept
constamment revu par la CEI afin qu'il reflète l'état under constant review by the IEC, thus ensuring that
actuel de la technique. Des renseignements relatifs à the content reflects current technology. Information
cette publication, y compris sa validité, sont dispo- relating to this publication, including its validity, is
nibles dans le Catalogue des publications de la CEI available in the IEC Catalogue of publications
(voir ci-dessous) en plus des nouvelles éditions, (see below) in addition to new editions, amendments
amendements et corrigenda. Des informations sur les and corrigenda. Information on the subjects under
sujets à l’étude et l’avancement des travaux entrepris consideration and work in progress undertaken by the
par le comité d’études qui a élaboré cette publication, technical committee which has prepared this
ainsi que la liste des publications parues, sont publication, as well as the list of publications issued,
également disponibles par l’intermédiaire de: is also available from the following:
• Site web de la CEI (www.iec.ch) • IEC Web Site (www.iec.ch)
• Catalogue des publications de la CEI • Catalogue of IEC publications
Le catalogue en ligne sur le site web de la CEI The on-line catalogue on the IEC web site
(www.iec.ch/catlg-f.htm) vous permet de faire des (www.iec.ch/catlg-e.htm) enables you to search
recherches en utilisant de nombreux critères, by a variety of criteria including text searches,
comprenant des recherches textuelles, par comité technical committees and date of publication. On-
d’études ou date de publication. Des informations line information is also available on recently
en ligne sont également disponibles sur les issued publications, withdrawn and replaced
nouvelles publications, les publications rempla- publications, as well as corrigenda.
cées ou retirées, ainsi que sur les corrigenda.
• IEC Just Published
• IEC Just Published
Ce résumé des dernières publications parues
This summary of recently issued publications
(www.iec.ch/JP.htm) est aussi disponible par
(www.iec.ch/JP.htm) is also available by email.
courrier électronique. Veuillez prendre contact
Please contact the Customer Service Centre (see
avec le Service client (voir ci-dessous) pour plus
below) for further information.
d’informations.
• Service clients
• Customer Service Centre
Si vous avez des questions au sujet de cette
If you have any questions regarding this
publication ou avez besoin de renseignements
publication or need further assistance, please
supplémentaires, prenez contact avec le Service
contact the Customer Service Centre:
clients:
Email: custserv@iec.ch
Email: custserv@iec.ch
Tél: +41 22 919 02 11
Tel: +41 22 919 02 11
Fax: +41 22 919 03 00
Fax: +41 22 919 03 00
.
NORME CEI
INTERNATIONALE IEC
60364-5-51
INTERNATIONAL
Quatrième édition
STANDARD
Fourth edition
2001-08
Installations électriques des bâtiments –
Partie 5-51:
Choix et mise en œuvre des matériels électriques –
Règles communes
Electrical installations of buildings –
Part 5-51:
Selection and erection of electrical equipment –
Common rules
 IEC 2001 Droits de reproduction réservés  Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in
utilisée sous quelque forme que ce soit et par aucun procédé, any form or by any means, electronic or mechanical,
électronique ou mécanique, y compris la photocopie et les including photocopying and microfilm, without permission in
microfilms, sans l'accord écrit de l'éditeur. writing from the publisher.
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http://www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
W
PRICE CODE
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue

– 2 – 60364-5-51 © CEI:2001
SOMMAIRE
AVANT-PROPOS . 4

510  Introduction . 8

510.1  Domaine d’application . 8

510.2  Références normatives. 8

510.3  Généralités. 12
511  Conformité aux normes . 12
512  Conditions de service et influences externes . 12
512.1 Conditions de service . 12
512.2 Influences externes . 14
513  Accessibilité . 38
513.1  Généralités. 38
514  Identification. 38
514.1  Généralités. 38
514.2 Canalisations . 38
514.3 Identification des conducteurs neutre et de protection . 38
514.4 Dispositifs de protection . 38
514.5 Schémas . 38
515  Indépendance des matériels. 40
Annexe A (informative) Liste abrégée des influences externes . 42
Annexe B (informative) Relations entre la température de l'air, l'humidité relative
et l'humidité absolue . 44
Annexe C (normative) Classification des conditions mécaniques . 64
Annexe D (normative) Classification des macro-environnements . 66
Annexe E (informative) CEI 60364 – Parties 1 à 6: Restructuration . 68
Bibliographie . 76

Tableau 51A – Caractéristiques des influences externes .16 à 36

60364-5-51 © IEC:2001 – 3 –
CONTENTS
FOREWORD . 5

510 Introduction.9

510.1 Scope.9

510.2 Normative references.9

510.3 General.13
511 Compliance with standards .13
512 Operational conditions and external influences. 13
512.1 Operational conditions. 13
512.2 External influences.15
513 Accessibility.39
513.1 General.39
514 Identification.39
514.1 General.39
514.2 Wiring systems.39
514.3 Identification of neutral and protective conductors . 39
514.4 Protective devices.39
514.5 Diagrams.39
515 Prevention of mutual detrimental influence . 41
Annex A (informative) Concise list of external influences. 43
Annex B (informative) Interdependence of air temperature, relative air humidity and
absolute air humidity . 45
Annex C (normative)  Classification of mechanical conditions. 65
Annex D (normative)  Classification of macro-environments . 67
Annex E (informative) IEC 60364 – Parts 1 to 6: Restructuring. 69
Bibliography . 77

Table 51A – Characteristics of external influences .17 – 37

– 4 – 60364-5-51 © CEI:2001
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE

____________
INSTALLATIONS ÉLECTRIQUES DES BÂTIMENTS –

Partie 5-51: Choix et mise en œuvre des matériels électriques –

Règles communes
AVANT-PROPOS
1) La CEI (Commission Électrotechnique Internationale) est une organisation mondiale de normalisation
composée de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a
pour objet de favoriser la coopération internationale pour toutes les questions de normalisation dans les
domaines de l'électricité et de l'électronique. A cet effet, la CEI, entre autres activités, publie des Normes
internationales. Leur élaboration est confiée à des comités d'études, aux travaux desquels tout Comité national
intéressé par le sujet traité peut participer. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec la CEI, participent également aux travaux. La CEI collabore étroitement
avec l'Organisation Internationale de Normalisation (ISO), selon des conditions fixées par accord entre les
deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux intéressés
sont représentés dans chaque comité d’études.
3) Les documents produits se présentent sous la forme de recommandations internationales. Ils sont publiés
comme normes, spécifications techniques, rapports techniques ou guides et agréés comme tels par les
Comités nationaux.
4) Dans le but d'encourager l'unification internationale, les Comités nationaux de la CEI s'engagent à appliquer de
façon transparente, dans toute la mesure possible, les Normes internationales de la CEI dans leurs normes
nationales et régionales. Toute divergence entre la norme de la CEI et la norme nationale ou régionale
correspondante doit être indiquée en termes clairs dans cette dernière.
5) La CEI n’a fixé aucune procédure concernant le marquage comme indication d’approbation et sa responsabilité
n’est pas engagée quand un matériel est déclaré conforme à l’une de ses normes.
6) L’attention est attirée sur le fait que certains des éléments de la présente Norme internationale peuvent faire
l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence.
La Norme internationale CEI 60364-5-51 a été établie par le comité d'études 64 de la CEI:
Installations électriques et protection contre les chocs électriques.
La série des normes CEI 60364 (parties 1 à 6) est actuellement en restructuration, sans
changements techniques, sous une forme simple (voir annexe E).
Sur la décision unanime du Comité d'action (CA/1720/RV (2000-03-21)), les parties de la

CEI 60364 établies selon la nouvelle structure, n'ont pas été soumises aux Comités nationaux
pour approbation.
Le texte de la présente quatrième édition de la CEI 60364-5-51 est le résultat d'une
compilation de, et remplace
– la partie 5-51, troisième édition (1997),
– la partie 3, seconde édition (1993), son amendement 1 (1994) et son amendement 2 (1995);
La présente publication a été élaborée, autant que possible, conformément aux Directives
ISO/CEI partie 3.
L’annexe C et D font partie intégrante de cette norme.
Les annexes A et B sont données uniquement à titre d'information.

60364-5-51 © IEC:2001 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION

____________
ELECTRICAL INSTALLATIONS OF BUILDINGS –

Part 5-51: Selection and erection of electrical equipment –

Common rules
FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, the IEC publishes International Standards. Their preparation is
entrusted to technical committees; any IEC National Committee interested in the subject dealt with may
participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. The IEC collaborates closely with the International
Organization for Standardization (ISO) in accordance with conditions determined by agreement between the
two organizations.
2) The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an
international consensus of opinion on the relevant subjects since each technical committee has representation
from all interested National Committees.
3) The documents produced have the form of recommendations for international use and are published in the form
of standards, technical specifications, technical reports or guides and they are accepted by the National
Committees in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with one of its standards.
6) Attention is drawn to the possibility that some of the elements of this International Standard may be the subject
of patent rights. The IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60364-5-51 has been prepared by IEC technical committee 64:
Electrical installations and protection against electric shock.
The IEC 60364 series (parts 1 to 6), is currently being restructured, without any technical
changes, into a more simple form (see annex E).
According to a unanimous decision by the Committee of Action (CA/1720/RV (2000-03-21)),
the restructured parts of IEC 60364 have not been submitted to National Committees for
approval.
The text of this fourth edition of IEC 60364-5-51 is compiled from and replaces
– part 5-51, third edition (1997),
– part 3, second edition (1993), its amendment 1 (1994) and amendment 2 (1995);
This publication has been drafted, as close as possible, in accordance with the
ISO/IEC Directives, Part 3.
Annexes C and D form an integral part of this standard.
Annexes A and B are for information only.

– 6 – 60364-5-51 © CEI:2001
Le comité a décidé que le contenu de cette publication ne sera pas modifié avant 2005.
A cette date, la publication sera

reconduite;
supprimée;
remplacée par une édition révisée, ou

amendée.
60364-5-51 © IEC:2001 – 7 –
The committee has decided that the contents of this publication will remain unchanged
until 2005. At this date, the publication will be

reconfirmed;
withdrawn;
replaced by a revised edition, or

amended.
– 8 – 60364-5-51 © CEI:2001
INSTALLATIONS ÉLECTRIQUES DES BÂTIMENTS –

Partie 5-51: Choix et mise en œuvre des matériels électriques –

Règles communes
510  Introduction
510.1  Domaine d’application
La présente partie de la CEI 60364 traite du choix du matériel et de sa mise en œuvre. Il doit
permettre de satisfaire aux mesures de protection pour assurer la sécurité, aux prescriptions
pour assurer un fonctionnement satisfaisant de l'installation pour l'utilisation prévue, et aux
prescriptions appropriées aux conditions d'influences externes prévisibles.
510.2  Références normatives
Les documents normatifs suivants contiennent des dispositions qui, par suite de la référence
qui y est faite, constituent des dispositions valables pour la présente partie de la CEI 60364.
Au moment de la publication, les éditions indiquées étaient en vigueur. Tout document
normatif est sujet à révision et les parties prenantes aux accords fondés sur la présente partie
de la CEI 60364 sont invitées à rechercher la possibilité d'appliquer les éditions les plus
récentes des documents normatifs indiqués ci-après. Les membres de la CEI et de l'ISO
possèdent le registre des Normes internationales en vigueur.
CEI 60068-2-11:1981, Essais d’environnement – Deuxième partie: Essais. Essai Ka:
Brouillard salin
CEI 60073:1996, Principes fondamentaux et de sécurité pour l'interface homme-machine, le
marquage et l'identification – Principes de codage pour les dispositifs indicateurs et les
organes de commande
CEI 60079 (toutes les parties), Matériel électrique pour atmosphères explosives gazeuses
CEI 60255-22-1:1988, Relais électriques – Partie 22: Essais d'influence électrique concernant
les relais de mesure et dispositifs de protection – Section 1: Essais à l'onde oscillatoire
amortie à 1 MHz
CEI 60364-1:2001, Installations électriques des bâtiments – Partie 1: Principes fondamentaux
CEI 60364-4-41:2001, Installations électriques des bâtiments – Partie 4-41: Protection pour
assurer la sécurité – Protection contre les chocs électriques

CEI 60364-4-42:2001, Installations électriques des bâtiments – Partie 4-42: Protection pour
assurer la sécurité – Protection contre les effets thermiques
CEI 60364-4-44:2001, Installations électriques des bâtiments – Partie 4-44: Protection pour
assurer la sécurité – Protection contre les perturbations de tension et électromagnétiques
CEI 60364-5-52:2001, Installations électriques des bâtiments – Partie 5-52: Choix et mise en
œuvre des matériels électriques – Canalisations
CEI 60364-5-54, Installations électriques des bâtiments – Partie 5-54: Choix et mise en
œuvre des matériels électriques – Mise à la terre et conducteurs de protection

60364-5-51 © IEC:2001 – 9 –
ELECTRICAL INSTALLATIONS OF BUILDINGS –

Part 5-51: Selection and erection of electrical equipment –

Common rules
510  Introduction
510.1  Scope
This part of IEC 60364 deals with the selection of equipment and its erection. It provides

common rules for compliance with measures of protection for safety, requirements for proper
functioning for intended use of the installation, and requirements appropriate to the external
influences foreseen.
510.2  Normative references
The following normative documents contain provisions which, through reference in this text,
constitute provisions of this part of IEC 60364. For dated references, subsequent
amendments to, or revisions of, any of these publications do not apply. However, parties to
agreements based on this part of IEC 60364 are encouraged to investigate the possibility of
applying the most recent editions of the normative documents indicated below. For undated
references, the latest edition of the normative document referred to applies. Members of
IEC and ISO maintain registers of currently valid International Standards.
IEC 60068-2-11:1981, Environmental testing – Part 2: Tests. Test Ka: Salt mist
IEC 60073:1996, Basic and safety principles for man-machine interface, marking and
identification – Coding principles for indication devices and actuators
IEC 60079 (all parts), Electrical apparatus for explosive gas atmospheres
IEC 60255-22-1:1988, Electrical relays – Part 22: Electrical disturbance tests for measuring
relays and protection equipment – Section 1: 1 MHz burst disturbance tests
IEC 60364-1:2001, Electrical installations of buildings – Part 1: Fundamental principles
IEC 60364-4-41:2001, Electrical installations of buildings – Part 4-41: Protection for safety –
Protection against electric shock

IEC 60364-4-42:2001, Electrical installations of buildings – Part 4-42: Protection for safety –
Protection against thermal effects
IEC 60364-4-44:2001, Electrical installations of buildings – Part 4-44: Protection for safety –
Protection against voltage disturbances and electromagnetic disturbances
IEC 60364-5-52:2001, Electrical installations of buildings
− Part 5-52: Selection and erection
of electrical equipment – Wiring systems
IEC 60364-5-54, −
Electrical installations of buildings Part 5-54: Selection and erection of
electrical equipment – Earthing arrangements and protective conductors and equipotential
bonding
– 10 – 60364-5-51 © CEI:2001
CEI 60446:1999, Principes fondamentaux et de sécurité pour les interfaces homme-machines,
le marquage et l'identification – Identification des conducteurs par des couleurs ou par des

repères numériques
CEI 60447:1993, Interface homme-machine (IHM) – Principes de manœuvre

CEI 60617 (toutes les parties): Symboles graphiques pour schémas

CEI 60707:1999, Inflammabilité des matériaux solides non métalliques soumis à des sources

d'allumage à flamme – Liste des méthodes d'essai

CEI 60721-3-0:1984, Classification des conditions d'environnement – Troisième partie:

Classification des groupements des agents d'environnement et de leurs sévérités –
Introduction
CEI 60721-3-3:1994, Classification des conditions d'environnement – Troisième partie:
Classification des groupements des agents d'environnement et de leurs sévérités – Section 3:
Utilisation à poste fixe, protégé contre les intempéries
CEI 60721-3-4:1995, Classification des conditions d'environnement – Troisième partie:
Classification des groupements des agents d'environnement et de leurs sévérités – Section 4:
Utilisation à poste fixe, non protégé contre les intempéries
CEI 61000-2 (toutes les parties), Compatibilité électromagnétique (CEM) – Deuxième partie:
Environnement
CEI 61000-2-1:1990, Compatibilité électromagnétique (CEM) – Partie 2: Environnement –
Section 1: Description de l’environnement – Environnement électromagnétique pour les
perturbations conduites basse fréquence et la transmission de signaux sur les réseaux
publics d’alimentation
CEI 61000-2-2:1990, Compatibilité électromagnétique (CEM) – Partie 2: Environnement –
Section 2: Niveaux de compatibilité pour les perturbations conduites basse fréquence et la
transmission des signaux sur les réseaux publics d’alimentation à basse tension
CEI 61000-2-5:1995, Compatibilité électromagnétique (CEM) – Partie 2: Environnement –
Section 5: Classification des environnements électromagnétiques Compatibilité électro-
magnétique (CEM) – Deuxième partie: Environnement. Publication fondamentale en CEM
CEI 61000-4-2:1995, Compatibilité électromagnétique (CEM) – Partie 4: Techniques d’essai
et de mesure – Section 2: Essai d’immunité aux décharges électrostatiques. Publication
fondamentale en CEM
CEI 61000-4-4:1995, Compatibilité électromagnétique (CEM) – Partie 4: Techniques d’essai

et de mesure – Section 4: Essais d’immunité aux décharges électrostatiques. Publication
fondamentale en CEM
CEI 61000-4-6:1996, Compatibilité électromagnétique (CEM) – Partie 4: Techniques d’essai
et de mesure – Section 6: Immunité aux perturbations conduites, induites par les champs
radioélectriques
CEI 61000-4-8:1993, Compatibilité électromagnétique (CEM) – Partie 4: Techniques d’essai
et de mesure – Section 8: Essai d’immunité au champ magnétique à la fréquence du réseau.
Publication fondamentale en CEM
CEI 61000-4-12:1995, Compatibilité électromagnétique (CEM) – Partie 4: Techniques d’essai
et de mesure – Section 12: Essai d’immunité aux ondes oscillatoires. Publication fonda-
mentale en CEM
60364-5-51 © IEC:2001 – 11 –
IEC 60446:1999, Basic and safety principles for man-machine interface, marking and
identification – Identification of conductors by colours or numerals

IEC 60447:1993, Man-machine interface (MMI) – Actuating principles

IEC 60617 (all parts), Graphical symbols for diagrams

IEC 60707:1999, Flammability of solid non-metallic materials when exposed to flame sources –

List of test methods
IEC 60721-3-0:1984, Classification of environmental conditions – Part 3: Classification of
groups of environmental parameters and their severities. Introduction
IEC 60721-3-3:1994, Classification of environmental conditions – Part 3: Classification of
groups of environmental parameters and their severities – Section 3: Stationary use at
weather-protected locations
IEC 60721-3-4:1995, Classification of environmental conditions – Part 3: Classification of
groups of environmental parameters and their severities – Section 4: Stationary use at non-
weatherprotected locations
IEC 61000-2 (all parts) Electromagnetic compatibility (EMC) – Part 2: Environment
IEC 61000-2-1:1990, Electromagnetic compatibility (EMC) – Part 2: Environment – Section 1:
Description of the environment – Electromagnetic environment for low-frequency conducted
disturbances and signalling in public power supply systems
IEC 61000-2-2:1990, Electromagnetic compatibility (EMC) – Part 2: Environment – Section 2:
Compatibility levels for low-frequency conducted disturbances and signalling in public low-
voltage power supply systems
IEC 61000-2-5:1995, Electromagnetic compatibility (EMC) – Part 2: Environment – Section 5:
Classification of electromagnetic environments. Basic EMC publication
IEC 61000-4-2:1995, Electromagnetic compatibility (EMC) – Part 4: Testing and measurement
techniques – Section 2: Electrostatic discharge immunity test. Basic EMC publication
IEC 61000-4-4:1995, Electromagnetic compatibility (EMC) – Part 4: Testing and measurement
techniques – Section 4: Electrical fast transient/burst immunity test. Basic EMC publication

IEC 61000-4-6:1996, Electromagnetic compatibility (EMC) – Part 4: Testing and measurement
techniques – Section 6: Immunity to conducted disturbances, induced by radio-frequency
fields
IEC 61000-4-8:1993, Electromagnetic compatibility (EMC) – Part 4: Testing and measurement
techniques – Section 8: Power frequency magnetic field immunity test. Basic EMC publication
IEC 61000-4-12:1995, Electromagnetic compatibility (EMC) – Part 4: Testing and measurement
techniques – Section 12: Oscillatory waves immunity test. Basic EMC publication

– 12 – 60364-5-51 © CEI:2001
CEI 61024-1:1990, Protection des structures contre la foudre – Première partie: Principes
généraux
CEI 61082 (toutes les parties), Etablissement des documents utilisés en électrotechnique

CEI 61140:1997, Protection contre les chocs électriques – Aspects communs pour les

installations et les matériels

CEI 61346-1:1996, Systèmes industriels, installations et appareils et produits industriels –

Principes de structuration et désignations de référence – Partie 1: Règles de base

510.3  Généralités
Chaque matériel doit être choisi et mis en œuvre de manière à se conformer aux règles
prescrites dans les articles de la présente partie de la CEI 60364 et aux règles appropriées
des autres parties de la série CEI 60364.
511  Conformité aux normes
511.1 Les matériels doivent satisfaire aux normes de la CEI qui leur sont applicables ainsi
qu'à toute norme de l'ISO qui les concerne.
511.2 A défaut de normes CEI ou ISO applicables, les matériels concernés doivent être
choisis par accord spécial entre le maître d'œuvre et l'installateur.
512  Conditions de service et influences externes
512.1 Conditions de service
512.1.1 Tension
Les matériels doivent être adaptés à la tension nominale (valeur efficace en courant
alternatif) de l'installation.
Si, dans une installation IT, le conducteur neutre est distribué, les matériels connectés entre
une phase et le neutre doivent être isolés pour la tension entre phases.
NOTE Pour certains matériels, il peut être nécessaire de tenir compte de la tension la plus élevée ou la plus
faible susceptible de se présenter en régime normal.
512.1.2 Courant
Les matériels doivent être choisis compte tenu du courant d'emploi (valeur efficace en
courant alternatif) qui les parcourt en service normal.
Il y a également lieu de considérer le courant susceptible de les parcourir dans des conditions
anormales, en tenant compte de la durée du passage d'un tel courant en fonction des
caractéristiques de fonctionnement des dispositifs de protection.
512.1.3 Fréquence
Si la fréquence a une influence sur les caractéristiques des matériels, la fréquence assignée
des matériels doit correspondre à la fréquence du courant dans le circuit correspondant.

60364-5-51 © IEC:2001 – 13 –
IEC 61024-1:1990, Protection of structures against lightning – Part 1: General principles

IEC 61082 (all parts), Preparation of documents used in electrotechnology

IEC 61140:1997, Protection against electric shock – Common aspects for installation and

equipment
IEC 61346-1:1996, Industrial systems, installations and equipment and industrial products –

Structuring principles and reference designations – Part 1: Basic rules

510.3  General
Every item of equipment shall be selected and erected so as to allow compliance with the
rules stated in the following clauses of this part of IEC 60364 and the relevant rules in other
parts of the IEC 60364 series.
511  Compliance with standards
511.1  Every item of equipment shall comply with such standards as are appropriate and, in
addition, with any applicable standards of the ISO.
511.2  Where there are no applicable or ISO standards, the item of equipment concerned
shall be selected by special agreement between the person specifying the installation, and the
installer.
512  Operational conditions and external influences
512.1  Operational conditions
512.1.1  Voltage
Equipment shall be suitable for the nominal voltage (r.m.s. value for a.c.) of the installation.
If, in IT installations, the neutral conductor is distributed, equipment connected between
phase and neutral shall be insulated for the voltage between phases.
NOTE For certain equipment, it may be necessary to take account of the highest and/or lowest voltage likely to
occur in normal service.
512.1.2  Current
Equipment shall be selected for the design current (r.m.s. value for a.c.) which it has to carry
in normal service.
Equipment shall also be capable of carrying the currents likely to flow in abnormal conditions
for such periods of time as are determined by the characteristics of the protective devices.
512.1.3  Frequency
If frequency has an influence on the characteristics of equipment, the rated frequency of the
equipment shall correspond to the frequency of the current in the circuit concerned.

– 14 – 60364-5-51 © CEI:2001
512.1.4  Puissance
Les matériels choisis d'après leurs caractéristiques de puissance, doivent être appropriés aux

conditions normales de service compte tenu de coefficients d'utilisation.

512.1.5 Compatibilité
A moins que les dispositions appropriées ne soient prises lors de la mise en œuvre, les

matériels doivent être choisis de manière à n'apporter, en service normal, de troubles ni aux

autres matériels ni au réseau d'alimentation, y compris lors de manœuvres.

512.2 Influences externes
NOTE Des références antérieures aux influences externes sont traitées en 320.1 et 320.2 de la CEI 60364-3.
512.2.1 Les matériels électriques doivent être choisis et mis en œuvre conformément aux
prescriptions du tableau 51A; ce tableau indique les caractéristiques des matériels en
fonction des influences externes auxquelles ils peuvent être soumis.
Les caractéristiques des matériels doivent être déterminées, soit par un degré de protection,
soit par la conformité à des essais.
512.2.2  Lorsqu'un matériel ne comporte pas, par construction, les caractéristiques
correspondant aux influences externes du local (ou de l'emplacement), il peut néanmoins être
utilisé à condition qu'il soit pourvu, lors de la réalisation de l'installation, d'une protection
complémentaire appropriée. Cette protection ne doit pas nuire aux conditions de
fonctionnement du matériel ainsi protégé.
512.2.3  Lorsque différentes influences externes se produisent simultanément, leurs effets
peuvent être indépendants ou s'influencer mutuellement et les degrés de protection doivent
être choisis en conséquence.
512.2.4  Le choix des caractéristiques des matériels en fonction des influences externes est
nécessaire, non seulement pour leur fonctionnement correct, mais aussi pour garantir la
fiabilité des mesures de protection pour assurer la sécurité conformément aux règles
générales de la CEI 60364. Les mesures de protection associées à la construction des
matériels sont en effet valables pour des conditions d'influences externes données dans la
mesure où les essais correspondants prévus par les spécifications des matériels sont
effectués dans ces conditions d'influences externes.
NOTE 1  Dans le cadre de la présente norme, les classes suivantes d'influences externes sont considérées
conventionnellement comme normales:

AA Température ambiante AA4
AB Humidité atmosphérique AB4
Autres conditions d'environnement XX1 de chaque paramètre
(AC à AR)

Conditions d'utilisation XX1 pour tous les paramètres, excepté

et de construction des bâtiments (B et C) XX2 pour le paramètre BC

NOTE 2  Le mot «normal» figurant dans la troisième colonne du tableau signifie que le matériel doit satisfaire
d'une façon générale aux normes de la CEI qui lui sont applicables.

60364-5-51 © IEC:2001 – 15 –
512.1.4  Power
Equipment selected for its power characteristics shall be suitable for the normal operational
conditions taking account of the load factor.

512.1.5  Compatibility
Unless other suitable precautions are taken during erection, all equipment shall be selected

so that it will not cause harmful effects on other equipment nor impair the supply during
normal service, including switching operations.

512.2  External influences
NOTE Previous mention to external influences was dealt with in 320.1 and 320.2 of 60364-3.
512.2.1 Electrical equipment shall be selected and erected in accordance with the
requirements of table 51A, which indicates the characteristics of equipment necessary
according to the external influences to which the equipment may be subjected.
Equipment characteristics shall be determined either by a degree of protection or by
conformity to tests.
512.2.2 If the equipment does not, by its construction, have the characteristics relevant to
the external influences of its location, it may nevertheless be used on condition that it is
provided with appropriate additional protection in the erection of the installation. Such
protection shall not adversely affect the operation of the equipment thus protected.
512.2.3 When different external influences occur simultaneously, they may have
independent or mutual effect and the degree of protection shall be provided accordingly.
512.2.4 The selection of equipment according to external influences is necessary not only
for proper functioning, but also to ensure the reliability of the measures of protection for
safety complying with the rules of 60364 generally. Measures of protection afforded by the
construction of equipment are valid only for the given conditions of external influence if the
corresponding equipment specification tests are made in these conditions of external
influence.
NOTE 1  For the purpose of this standard, the following classes of external influences are conventionally regarded
as normal:
AA Ambient temperature AA4
AB Atmospheric humidity AB4
Other environmental conditions XX1 of each parameter
(AC to AR)

Utilization and construction XX1 of each parameter, except

of buildings (B and C) XX2 for the parameter BC

NOTE 2  The word "normal" appearing in the third column of the table signifies that the equipment must generally
satisfy applicable IEC standards.

– 16 – 60364-5-51 © CEI:2001
Tableau 51A – Caractéristiques des influences externes (tableaux 321 et 322

de la CEI 60364-3, 1993 et tableau 51A de la CEI 60364-5-51, 1997)

Code Influences externes Caractéristiques pres- Référence

crites pour le choix et
la mise en œuvre
des matériels
A Conditions d’environnement
AA Température ambiante
La température ambiante est celle de l’air
ambiant à l’emplacement où le matériel doit
être installé
Il est supposé que cette température tient
compte des effets de tous les autres matériels
installés dans le même local
La température ambiante à considérer pour le
matériel est la température à l’endroit où ce
matériel doit être installé, résultant de
l’influence de tous les autres matériels placés
dans le même endroit et en fonctionnement,
sans tenir compte de la contribution thermique
du matériel considéré
Limites inférieures et supérieures des plages de
température ambiante:
AA1 –60 °C +5 °C
− Comprend la plage de

température de la classe 3K8

de la CEI 60721-3-3, la

 température supérieure de l’air

étant limitée

à +5 °C. Partie de la plage de

température de la classe 4K4

de la CEI 60721-3-4, la

température inférieure de l’air

 étant limitée à

–60 °C et la température

supérieure de l’air à +5 °C


− Partie de la plage de

température de la classe 3K7
AA2

–40 °C +5 °C
de la CEI 60721-3-3, la

température supérieure de l’air

Matériel spécialement
étant limitée

étudié ou dispositions
 à +5 °C. Comprend une partie
a

appropriées de la plage de température de la

classe 4K3 de la CEI 60721-3-4,

la température supérieure de l’air

étant limitée à +5 °C


AA3 –25 °C +5 °C − Partie de la plage de

température de la classe 3K6

de la CEI 60721-3-3, la

 température supérieure de l’air

étant limitée à +5 °C. Comprend

la plage de température de la

classe 4K1 de la CEI 60721-3-4,

la température supérieure de l’air

étant limitée à +5 °C


AA4 –5 °C +40 °C Normal (dans certains
− Partie de la plage de
cas des précautions
température de la classe 3K5
spéciales peuvent être de la CEI 60721-3-3, la
nécessaires) température supérieure de l’air
étant limitée à +40 °C
AA5 +5 °C +40 °CNormal − Identique à la plage de
température de la classe 3K3
de la CEI 60721-3-3
a
Peut nécessiter certaines précautions supplémentaires (par exemple lubrification spéciale)
b
Signifie qu’un matériel ordinaire fonctionnera de manière sûre dans les conditions d’influences externes décrites.
c
Signifie que des dispositions particulières doivent être prises, par exemple, entre le concepteur de l’installation
et le fabricant de matériels, par exemple pour des matériels spécialement étudiés.

60364-5-51 © IEC:2001 – 17 –
Table 51A – Characteristics of external influences (tables 321, 322 of 60364-3,1993

and table 51a of 60364-5-51, 1997)

Code External influences Characteristics required Reference

for selection and
erection of equipment
A Environmental conditions
AA Ambient temperature
The ambient temperature is that of the ambient

air where the equipment is to be installed

It is assumed that the ambient temperature

includes the effects of other equipment
installed in the same location
The ambient temperature to be considered for
the equipment is the temperature at the place
where the equipment is to be installed resulting
from the influence of all other equipment in the
same location, when operating, not taking into
account the thermal contribution of the
equipment to be installed
Lower and upper limits of ranges of ambient
temperature:

AA1 –60 °C +5 °C
Includes temperature range

of IEC 60721-3-3, class 3K8,

with high air temperature

restricted to +5 °C. Part of

 temperature range of
 IEC 60721-3-4, class 4K4,

with low air temperature

restricted to –60 °C and high

air temperature restricted

to +5 °C


Part of temperature range of

AA2 –40 °C +5 °C
IEC 60721-3-3, class 3K7,

with high air temperature

 restricted to +5 °C. Includes

pa
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...