IEC 60761-4:2002
(Main)Equipment for continuous monitoring of radioactivity in gaseous effluents - Part 4: Specific requirements for radioactive iodine monitors
Equipment for continuous monitoring of radioactivity in gaseous effluents - Part 4: Specific requirements for radioactive iodine monitors
Lays down specific standard requirements, including technical characteristics and general test conditions, and gives examples of acceptable methods for iodine monitors.
Equipements de surveillance en continu de la radioactivité dans les effluents gazeux - Partie 4: Exigences particulières aux moniteurs d'iode radioactif
Formule des exigences normatives spécifiques, notamment les caractéristiques techniques et les conditions générales d'essai, et donne des exemples de méthodes acceptables pour les moniteurs d'iode.
General Information
Standards Content (Sample)
NORME CEI
INTERNATIONALE IEC
60761-4
INTERNATIONAL
Deuxième édition
STANDARD
Second edition
2002-01
Equipements de surveillance en continu
de la radioactivité dans les effluents gazeux –
Partie 4:
Exigences particulières aux moniteurs
d'iode radioactif
Equipment for continuous monitoring
of radioactivity in gaseous effluents –
Part 4:
Specific requirements for radioactive
iodine monitors
Numéro de référence
Reference number
CEI/IEC 60761-4:2002
Numérotation des publications Publication numbering
Depuis le 1er janvier 1997, les publications de la CEI As from 1 January 1997 all IEC publications are
sont numérotées à partir de 60000. Ainsi, la CEI 34-1 issued with a designation in the 60000 series. For
devient la CEI 60034-1. example, IEC 34-1 is now referred to as IEC 60034-1.
Editions consolidées Consolidated editions
Les versions consolidées de certaines publications de la The IEC is now publishing consolidated versions of its
CEI incorporant les amendements sont disponibles. Par publications. For example, edition numbers 1.0, 1.1
exemple, les numéros d’édition 1.0, 1.1 et 1.2 indiquent and 1.2 refer, respectively, to the base publication,
respectivement la publication de base, la publication de the base publication incorporating amendment 1 and
base incorporant l’amendement 1, et la publication de the base publication incorporating amendments 1
base incorporant les amendements 1 et 2. and 2.
Informations supplémentaires Further information on IEC publications
sur les publications de la CEI
Le contenu technique des publications de la CEI est The technical content of IEC publications is kept
constamment revu par la CEI afin qu'il reflète l'état under constant review by the IEC, thus ensuring that
actuel de la technique. Des renseignements relatifs à the content reflects current technology. Information
cette publication, y compris sa validité, sont dispo- relating to this publication, including its validity, is
nibles dans le Catalogue des publications de la CEI available in the IEC Catalogue of publications
(voir ci-dessous) en plus des nouvelles éditions, (see below) in addition to new editions, amendments
amendements et corrigenda. Des informations sur les and corrigenda. Information on the subjects under
sujets à l’étude et l’avancement des travaux entrepris consideration and work in progress undertaken by the
par le comité d’études qui a élaboré cette publication, technical committee which has prepared this
ainsi que la liste des publications parues, sont publication, as well as the list of publications issued,
également disponibles par l’intermédiaire de: is also available from the following:
• Site web de la CEI (www.iec.ch) • IEC Web Site (www.iec.ch)
• Catalogue des publications de la CEI • Catalogue of IEC publications
Le catalogue en ligne sur le site web de la CEI The on-line catalogue on the IEC web site
(www.iec.ch/catlg-f.htm) vous permet de faire des (www.iec.ch/catlg-e.htm) enables you to search
recherches en utilisant de nombreux critères, by a variety of criteria including text searches,
comprenant des recherches textuelles, par comité technical committees and date of publication. On-
d’études ou date de publication. Des informations line information is also available on recently
en ligne sont également disponibles sur les issued publications, withdrawn and replaced
nouvelles publications, les publications rempla- publications, as well as corrigenda.
cées ou retirées, ainsi que sur les corrigenda.
• IEC Just Published
• IEC Just Published
Ce résumé des dernières publications parues
This summary of recently issued publications
(www.iec.ch/JP.htm) est aussi disponible par
(www.iec.ch/JP.htm) is also available by email.
courrier électronique. Veuillez prendre contact
Please contact the Customer Service Centre (see
avec le Service client (voir ci-dessous) pour plus
below) for further information.
d’informations.
• Service clients
• Customer Service Centre
Si vous avez des questions au sujet de cette
If you have any questions regarding this
publication ou avez besoin de renseignements
publication or need further assistance, please
supplémentaires, prenez contact avec le Service
contact the Customer Service Centre:
clients:
Email: custserv@iec.ch
Email: custserv@iec.ch
Tél: +41 22 919 02 11
Tel: +41 22 919 02 11
Fax: +41 22 919 03 00
Fax: +41 22 919 03 00
.
NORME CEI
INTERNATIONALE IEC
60761-4
INTERNATIONAL
Deuxième édition
STANDARD
Second edition
2002-01
Equipements de surveillance en continu
de la radioactivité dans les effluents gazeux –
Partie 4:
Exigences particulières aux moniteurs
d'iode radioactif
Equipment for continuous monitoring
of radioactivity in gaseous effluents –
Part 4:
Specific requirements for radioactive
iodine monitors
IEC 2002 Droits de reproduction réservés Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in
utilisée sous quelque forme que ce soit et par aucun procédé, any form or by any means, electronic or mechanical,
électronique ou mécanique, y compris la photocopie et les including photocopying and microfilm, without permission in
microfilms, sans l'accord écrit de l'éditeur. writing from the publisher.
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http://www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
P
PRICE CODE
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue
– 2 – 60761-4 CEI:2002
SOMMAIRE
AVANT-PROPOS .4
1 Domaine d’application et objet .8
2 Références normatives .8
3 Termes et définitions .10
4 Classification des moniteurs d’iode .10
5 Ensemble de prélèvement et de détection (le cas échéant) .10
6 Source de contrôle.14
7 Expression des résultats.14
8 Réponse à d'autres rayonnements ionisants.14
9 Discrimination de l’activité naturelle .14
10 Conditions normales d'essai .14
11 Essais effectués avec variation des grandeurs d'influence.16
12 Sources de référence et sources spéciales .16
13 Essais de performance avec des rayonnements .16
14 Essais du circuit d'air .18
15 Rapport sur les essais de type et certificat .20
Tableau 1 – Conditions de référence et conditions normales d’essai.22
Tableau 2 – Essais effectués dans les conditions normales d’essais.24
Tableau 3 – Essais effectués avec variation des grandeurs d’influence.26
Tableau 4 – Essais du circuit d’air .30
60761-4 IEC:2002 – 3 –
CONTENTS
FOREWORD.5
1 Scope and object .9
2 Normative references.9
3 Terms and definitions .11
4 Classification of iodine monitors.11
5 Sampling and detection assembly (where applicable) .11
6 Check source .15
7 Expression of measurement.15
8 Response to other ionizing radiations.15
9 Discrimination against natural activity.15
10 Standard test conditions .15
11 Tests performed with variation of the influence quantities .17
12 Reference and special sources .17
13 Radiation performance tests .17
14 Tests of the air circuit .19
15 Type test report and certificate.21
Table 1 – Reference conditions and standard test conditions .23
Table 2 – Tests performed under standard test conditions .25
Table 3 – Tests performed with variation of influence quantities.27
Table 4 – Tests of air circuit .31
– 4 – 60761-4 CEI:2002
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
___________
ÉQUIPEMENTS DE SURVEILLANCE EN CONTINU DE LA RADIOACTIVITÉ
DANS LES EFFLUENTS GAZEUX –
Partie 4: Exigences particulières aux moniteurs d'iode radioactif
AVANT-PROPOS
1) La CEI (Commission Electrotechnique Internationale) est une organisation mondiale de normalisation composée
de l’ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a pour objet de
favoriser la coopération internationale pour toutes les questions de normalisation dans les domaines de
l’électricité et de l’électrotechnique. A cet effet, la CEI, entre autres activités, publie des Normes
internationales. Leur élaboration est confiée à des comités d’études, aux travaux desquels tout Comité national
intéressé par le sujet traité peut participer. Des organisations internationales, gouvernementales et non
gouvernementales, en liaison avec la CEI, participent également aux travaux. La CEI collabore étroitement avec
l’Organisation Internationale de Normalisation (ISO), selon des conditions fixées par accord entre les deux
organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux intéressés
sont représentés dans chaque comité d’études.
3) Les documents produits se présentent sous la forme de recommandations internationales. Ils sont publiés
comme normes, spécifications techniques, rapports techniques ou guides et agréés comme tels par les Comités
nationaux.
4) Dans le but d’encourager l’unification internationale, les Comités nationaux de la CEI s’engagent à appliquer de
façon transparente, dans toute la mesure du possible, les Normes internationales de la CEI dans leurs normes
nationales et régionales. Toute divergence entre la norme de la CEI et la norme nationale ou régionale
correspondante doit être indiquée en termes clairs dans cette dernière.
5) La CEI n’a fixé aucune procédure concernant le marquage comme indication d’approbation et sa responsabilité
n’est pas engagée quand un matériel est déclaré conforme à l’une de ses normes.
6) L’attention est attirée sur le fait que certains des éléments de la présente Norme internationale peuvent faire
l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence.
La Norme internationale CEI 60761-4 a été établie par le sous-comité 45B: Instrumentation
pour la radioprotection, du comité d'études 45 de la CEI: Instrumentation nucléaire.
Cette norme doit être lue conjointement avec la CEI 60761-1 (2002).
Cette deuxième édition annule et remplace la première édition, publiée en 1983. Elle constitue
une révision technique.
Le texte de la présente norme est issu de la première édition et des documents suivants:
FDIS Rapport de vote
45B/336/FDIS 45B/347/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l’approbation de cette norme.
Cette publication a été rédigée selon les directives ISO/CEI, Partie 3.
60761-4 IEC:2002 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSlON
___________
EQUIPMENT FOR CONTINUOUS MONITORING OF RADIOACTIVITY
IN GASEOUS EFFLUENTS –
Part 4: Specific requirements for radioactive iodine monitors
FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, the IEC publishes International Standards. Their preparation is
entrusted to technical committees; any IEC National Committee interested in the subject dealt with may
participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. The IEC collaborates closely with the International Organization
for Standardization (ISO) in accordance with conditions determined by agreement between the two
organizations.
2) The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an
international consensus of opinion on the relevant subjects since each technical committee has representation
from all interested National Committees.
3) The documents produced have the form of recommendations for international use and are published in the form
of standards, technical specifications, technical reports or guides and they are accepted by the National
Committees in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International.
Standards transparently to the maximum extend possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with one of its standards.
6) Attention is drawn to the possibility that some of the elements of this International Standard may be the subject
of patent rights. The IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60761-4 has been prepared by subcommittee 45B: Radiation
protection instrumentation, of IEC technical committee 45: Nuclear instrumentation.
This standard shall be read in conjunction with IEC 60761-1 (2002).
This second edition cancels and replaces the first edition, published in 1983, of which it
constitutes a technical revision.
The text of this standard is based on the first edition, and the following documents:
FDIS Report on voting
45B/336/FDIS 45B/347/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 3.
– 6 – 60761-4 CEI:2002
Le comité a décidé que le contenu de cette publication ne sera pas modifié avant 2006. A cette
date, la publication sera
• reconduite;
• supprimée;
• remplacée par une édition révisée, ou
• amendée.
La CEI 60761 comprend les parties suivantes, présentées sous le titre général: Equipements
de surveillance en continu de la radioactivité dans les effluents gazeux.
Partie 1: Exigences générales
Partie 2: Exigences particulières aux moniteurs d'aérosols radioactifs, y compris les aérosols
transuraniens
Partie 3: Exigences particulières aux moniteurs de gaz rares radioactifs
Partie 4: Exigences particulières aux moniteurs d'iode radioactif
Partie 5: Exigences particulières aux moniteurs de tritium
60761-4 IEC:2002 – 7 –
The committee has decided that the contents of this publication will remain unchanged until
2006. At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
IEC 60761 consists of the following parts, under the general title: Equipment for continuous
monitoring of radioactivity in gaseous effluents.
Part 1: General requirements
Part 2: Specific requirements for radioactive aerosol monitors including transuranic aerosols
Part 3: Specific requirements for radioactive noble gas monitors
Part 4: Specific requirements for radioactive iodine monitors
Part 5: Specific requirements for tritium monitors
– 8 – 60761-4 CEI:2002
ÉQUIPEMENTS DE SURVEILLANCE EN CONTINU DE LA RADIOACTIVITÉ
DANS LES EFFLUENTS GAZEUX –
Partie 4: Exigences particulières aux moniteurs d'iode radioactif
1 Domaine d’application et objet
La présente partie de la CEI 60761 est applicable aux équipements destinés à la mesure en
continu, différée ou séquentielle discrète de l’iode radioactif sous toutes ses formes. Lorsque
l’effluent est prélevé pour la mesure, l’iode lié aux aérosols est généralement recueilli sur un
préfiltre qu’il convient d’analyser séparément en laboratoire, de façon à obtenir un résultat
complet.
Elle est applicable aux équipements conçus pour remplir les fonctions suivantes:
– la mesure de l’activité volumique d’iode et des composés iodés radioactifs dans les
effluents gazeux ou de l’activité totale d’iode rejeté;
– le déclenchement d’une alarme lorsqu’une concentration prédéterminée ou une activité
totale prédéterminée d’iode ou de ses composés est dépassée dans l’effluent gazeux.
Ces équipements sont prévus pour effectuer des mesures sur une large étendue d’activité et
en présence d’autres radionucléides, dans l’effluent gazeux, notamment des radionucléides
naturels. La compensation de ces autres radionucléides peut être importante quand on mesure
de faibles niveaux d’iode radioactif.
La présente norme prend en considération tant l’utilisation de milieux collecteurs d’iode, tel le
charbon actif, que la mesure directe de l’iode dans les conduits de fumée ou de ventilation.
L’objet de la présente norme est de formuler des exigences normatives spécifiques, et
notamment les caractéristiques techniques et les conditions générales d’essai, et de donner
des exemples de méthodes acceptables pour les moniteurs d’iode définis dans l’article 4.
Les exigences générales, les caractéristiques techniques, les procédures d’essai, les
caractéristiques des rayonnements, les caractéristiques électriques et mécaniques, de sécurité
et d’environnement figurent dans la CEI 60761-1.
Ces exigences sont applicables, sauf spécification contraire, à la présente norme.
2 Références normatives
Les documents normatifs suivants contiennent des dispositions qui, par suite de la référence
qui y est faite, constituent des dispositions valables pour la présente partie de la CEI 60761.
Pour les références datées, les amendements ultérieurs ou les révisions de ces publications
ne s’appliquent pas. Toutefois, les parties prenantes aux accords fondés sur la présente partie
de la CEI 60761 sont invitées à rechercher la possibilité d'appliquer les éditions les plus
récentes des documents normatifs indiqués ci-après. Pour les références non datées, la
dernière édition du document normatif en référence s’applique. Les membres de la CEI et de
l'ISO possèdent le registre des Normes internationales en vigueur.
CEI 60068-2-27:1987, Essais d’environnement – Deuxième partie: Essais. Essai Ea et guide:
Chocs
CEI 60761-1:2002, Equipements de surveillance en continu de la radioactivité dans les
effluents gazeux – Partie 1: Exigences générales
60761-4 IEC:2002 – 9 –
EQUIPMENT FOR CONTINUOUS MONITORING OF RADIOACTIVITY
IN GASEOUS EFFLUENTS –
Part 4: Specific requirements for radioactive iodine monitors
1 Scope and object
This part of IEC 60761 is applicable to equipment intended for the simultaneous, delayed or
discrete sequential measurement of radioactive iodine in all forms. When the effluent is
sampled for measurement, iodine bound on aerosols is generally collected on a prefilter which
should be analyzed separately in a laboratory to provide a complete measurement.
It is applicable to equipment designed to fulfill the following functions:
– the measurement of the volumic activity of iodine and compounds of radioactive iodine in
gaseous effluents or of the released iodine total activity;
– the actuation of an alarm signal when either a predetermined concentration or a
predetermined total released activity due to iodine or its compounds is exceeded.
This equipment is intended for measurement over a wide range of activity in the presence of
other radionuclides in the gaseous effluent, including naturally occurring radioactive nuclides.
Discrimination against other radionuclides can be important in measuring low levels of
radioactive iodine.
This standard considers both the use of iodine collection media such as activated charcoal and
the direct measurement of iodine in stacks or ventilation ducts.
The object of this standard is to lay down specific standard requirements, including technical
characteristics and general test conditions, and to give examples of acceptable methods for
iodine monitors as defined in clause 4.
The general requirements, technical characteristics, test procedures, radiation characteristics,
electrical, mechanical, safety and environmental characteristics are given in IEC 60761-1.
Unless otherwise stated, these requirements apply in this standard.
2 Normative references
The following normative documents contain provisions which, through reference in this text,
constitute provisions of this part of IEC 60761. For dated references, subsequent amendments
to, or revisions of, any of these publications do not apply. However, parties to agreements
based on this part of IEC 60761 are encouraged to investigate the possibility of applying the
most recent editions of the normative documents indicated below. For undated references, the
latest edition of the normative document referred to applies. Members of IEC and ISO maintain
registers of currently valid International Standards.
IEC 60068-2-27:1987, Environmental testing – Part 2: Tests. Test Ea and guidance: Shock
IEC 60761-1:2002, Equipment for continuous monitoring of radioactivity in gaseous effluents –
Part 1: General requirements
– 10 – 60761-4 CEI:2002
CEI 61000 (toutes les parties), Compatibilité électromagnétique (CEM)
EN 55022:1994, Limites et méthodes de mesure des caractéristiques de perturbation
radioélectriques produites par les appareils de traitement de l’information
3 Termes et définitions
Pour les besoins de la présente partie de la CEI 60761, les définitions suivantes s’appliquent:
3.1
iode
sauf spécification contraire, le mot «iode» désigne dans la présente norme l’iode radioactif
sous toutes ses formes, combinées chimiquement ou non, y compris l’iode fixé sur des
aérosols
NOTE L’iode lié à des aérosols est généralement piégé sur un préfiltre qu’il convient d’analyser séparément en
laboratoire.
3.2
moniteur d’iode
équipement conçu pour la surveillance en continu ou séquentielle de l’iode contenu dans les
effluents gazeux rejetés dans l’environnement
3.3
durée de vie du milieu collecteur
la durée d’échantillonnage depuis le début du prélèvement avec ce milieu jusqu'au moment où
l’efficacité de collecte est égale à 90 % de sa valeur nominale
4 Classification des moniteurs d’iode
Les équipements peuvent être classés, selon le type de rayonnement mesuré, en:
– moniteurs pour la mesure de l’iode 131 uniquement;
– moniteurs pour la mesure de l’iode 125 et/ou de l’iode 129;
– moniteurs pour la mesure globale de tous les isotopes de l'iode.
Les équipements peuvent également être classés en fonction du mode de fonctionnement, par
exemple:
– équipement avec milieu absorbant statique et mesure simultanée;
– équipement avec milieu absorbant mobile et mesure simultanée;
– équipement pour mesure directe de l’iode dans le conduit de fumée ou de ventilation.
5 Ensemble de prélèvement et de détection (le cas échéant)
5.1 Dispositif de prélèvement et d'échappement
En plus des exigences générales de la CEI 60761-1, les caractéristiques suivantes doivent être
prises en considération et faire l’objet d’un accord entre le constructeur et l’acheteur:
– nature des matériaux utilisés, en tenant compte en particulier de l’adsorption de l’iode;
– régulation de la température des passages d’air pour éviter la condensation de l’iode ou de
ses composés.
60761-4 IEC:2002 – 11 –
IEC 61000 (all parts), Electromagnetic compatibility (EMC)
EN 55022:1994, Limits and Methods of Measurement of Radio Disturbance Characteristics of
Information Technology Equipment
3 Terms and definitions
For the purpose of this part of IEC 60761, the following definitions apply:
3.1
iodine
unless otherwise specified, the use of the word “iodine” in this standard covers radioactive
iodine in all forms whether chemically combined or not, including iodine bound on aerosols
NOTE Iodine bound on aerosols is in general trapped on a prefilter which should be analyzed separately in a
laboratory.
3.2
iodine monitor
equipment designed for the continuous or sequential measurement of iodine in gaseous
effluents discharged to the environment
3.3
life time of the sampling medium
the time of sampling from operation with a medium to the time when the collection efficiency is
equal to 90 % of the nominal value
4 Classification of iodine monitors
The equipment may be classified according to the type of radiation measured as:
– monitors for the measurement of Iodine-131 only;
– monitors for the measurement of Iodine-125 and/or Iodine-129;
– monitors for the overall measurement of all iodine isotopes.
It may also be classified according to the method of operation, for example:
– equipment with static absorption medium and simultaneous measurement;
– equipment with moving absorption medium and simultaneous measurement;
– equipment for the direct measurement of iodine in the stack or duct.
5 Sampling and detection assembly (where applicable)
5.1 Sampling and exhaust system
In addition to the general requirements of IEC 60761-1, the following characteristics shall be
considered and shall be agreed upon between manufacturer and purchaser:
– the nature of the materials used paying particular attention to iodine adsorption;
– regulation of the temperature of the air passages to avoid condensation of iodine or its
compounds.
– 12 – 60761-4 CEI:2002
5.2 Pompe à air
Les exigences des articles 11 et 29 de la CEI 60761-1 s’appliquent.
De plus, la pompe à air ou à gaz doit être capable de maintenir le débit d’air ou de gaz requis,
indépendamment des variations de pression différentielle induites par les conditions normales
de fonctionnement (temps de prélèvement maximal prévu, dispositifs utilisables pour retenir
l’iode, empoussièrement atmosphérique, etc.). A la fin du prélèvement, le débit d’air ne doit
pas avoir diminué de plus de 10 % par rapport au débit nominal ou l’erreur sur le volume total
d’air prélevé ne doit pas dépasser 8 %.
Une alarme doit signaler tant la rupture du milieu collecteur d’iode (faible pression différen-
tielle) que le colmatage de ce milieu (différence de pression supérieure à celle qui entraîne une
chute de 10 % du débit).
5.3 Filtre d'entrée
Lorsque cela est nécessaire, pour les moniteurs d’iode sous forme de vapeur, un filtre peut
être placé dans un porte-filtre à l’entrée du circuit de prélèvement pour éliminer les poussières
et les aérosols. Afin de préserver les performances spécifiées pour l’ensemble, ce filtre ne doit
ni piéger, ni retenir, même temporairement, l’iode (sauf si ce dernier se trouve sous forme
d’aérosol).
Ce dispositif doit également être placé suffisamment loin du détecteur de rayonnement ou
protégé par un écran de façon que la contribution du filtre à l’indication soit négligeable.
5.4 Matériau de collecte de l’iode
– Le matériau de collecte peut avoir des géométries différentes selon le mode de
fonctionnement (voir article 4).
– Il convient que le dépôt d’iode soit aussi uniforme que possible. L’uniformité peut être
améliorée par l’utilisation d’un dispositif annulaire de circulation d'air.
– Les caractéristiques de conception du dispositif de rétention de l’iode (dimensions,
géométrie, etc.) doivent tenir compte des caractéristiques du milieu collecteur employé et
des caractéristiques de la pompe d'échantillonnage de l'air (ou du gaz).
41 85 133 222
– La présence de gaz radioactifs (par exemple Ar, Kr, Xe ou Rn) dans l’air surveillé
peut avoir une influence sur la mesure de l’iode. Cette remarque est particulièrement vraie
pour les détecteurs non sélectifs. Pour réduire les effets de ces radionucléides, l’espace
d’air autour du détecteur et dans le milieu collecteur de l'iode doit être réduit au minimum,
tout en tenant compte des exigences de 13.3.
– La conception doit viser à réduire au minimum les fuites d’air, et notamment les fuites
internes entraînant un contournement du milieu collecteur de l'iode.
– L’accès au dispositif de rétention de l’iode et au filtre doit être conçu de façon à permettre
le remplacement facile et rapide de ces derniers sans risque d’endommagement du
détecteur ou du dispositif de rétention. L’enlèvement du dispositif de collecte de l’iode ou
du filtre ne doit en outre pas exposer le personnel à une dose excessive de rayonnement.
– Le constructeur doit indiquer la durée de vie du milieu de collecte de l’iode. Celle-ci doit
être d’au moins huit jours pour les conditions de température et d’humidité relative de
référence. La durée du prélèvement à 90 % d’humidité relative doit être spécifiée par le
constructeur.
5.5 Efficacité de collecte et comportement du milieu collecteur
Le constructeur doit préciser le rendement de collecte ainsi que les capacités de conservation
du milieu collecteur pour l'iode élémentaire et ses composés volatils en fonction des différents
paramètres de piégeage.
60761-4 IEC:2002 – 13 –
5.2 Air pump
The requirements of clauses 11 and 29 of IEC 60761-1 are applicable.
Additionally, the air or gas pump shall be capable of maintaining the required air or gas flow-
rate independently of differences in differential pressure induced by normal operating
conditions (maximum expected sampling time, useable iodine retention devices, atmospheric
dust, etc.) so that, at the end of sampling, there shall not be a reduction from nominal air flow-
rate of more than 10 % or an error in the value of total air volume sampled of more than 8 %.
An alarm shall be fitted to detect both a rupture of the iodine retention medium (low differential
pressure) and blockage of the medium (pressure difference greater than that required to give a
10 % drop in flow-rate).
5.3 Inlet filter
When appropriate, in the case of an iodine vapour monitor, a filter may be placed in a filter
holder at the sampling circuit inlet to collect any dust and aerosols. In order to maintain the
specific performance of the equipment, such a filter shall not trap or even temporarily retain
iodine (except in aerosol form).
This device shall also be situated sufficiently far from the radiation detector or shielded, so that
the filter contribution to the reading is insignificant.
5.4 Iodine collection medium
– The collection medium may have different geometries according to the method of operation
of the assembly (see clause 4).
– The deposition of iodine should be as uniform as possible. Increased uniformity can be
acheived through the use of an annular air passage.
– The iodine retention device design characteristics (dimensions, geometry, etc.) shall take
account of the characteristics of the actual retention medium and the characteristics of the
air (or gas) sampling pump.
41 85 133 222
– The presence of radioactive gases (for example Ar, Kr, Xe or Rn) in the air being
monitored can have an effect on the monitoring of iodine. This is especially true for non-
selective detectors. To reduce the effects of these radionuclides, the air space in the
vicinity of the detector and inside the iodine collection medium shall be kept to the minimum
possible, taking into account the requirements of 13.3.
– The design shall be such as to minimize air leaks, particularly internal leaks causing the
flow to by-pass the iodine retention medium.
– Access to the iodine retention device and filter shall be such as to permit fast and easy
removal without damage to either the radiation detector or the iodine retention device. Also,
removal of the iodine retention device or the filter shall not expose personnel to an
excessive dose of radiation.
– The manufacturer shall state the life time of the iodine retention medium. This shall be at
least eight days for reference conditions of temperature and relative humidity. The duration
of sampling at 90 % of relative humidity shall be specified by the manufacturer.
5.5 Collection efficiency and retention behaviour
The manufacturer shall state the collection efficiency and the retention behaviour of the
collection medium for elemental and volatile compounds of iodine against various loading
factors.
– 14 – 60761-4 CEI:2002
Il est recommandé que le temps de contact de l’iode avec le milieu collecteur soit supérieur à
0,2 s. Si le temps de contact avec le milieu collecteur est inférieur à 0,2 s (par exemple pour
un moniteur ayant un grand débit de prélèvement), la diminution du rendement de collecte doit
être indiquée. Le rendement de collection doit être précisé par le constructeur et accepté par
l’acheteur.
Le constructeur doit indiquer de quelle manière le rendement de collecte est influencé par la
forme chimique de l’iode, les conditions atmosphériques et la présence de produits chimiques
dans l’air prélevé. Le constructeur doit préciser les conditions de stockage des milieux de
collecte.
5.6 Détecteur de rayonnement
Le constructeur doit spécifier toutes les caractéristiques du détecteur, et notamment ses
dimensions et ses caractéristiques de transmission telles que la surface utile de détection.
Lorsque le logement du détecteur est en contact direct avec le milieu gazeux surveillé, un soin
particulier doit être apporté à la conception pour faciliter la décontamination du détecteur.
6 Source de contrôle
Il convient qu’une source de contrôle soit fournie avec l’équipement. Dans le cas des
ensembles de mesure indirects, la source doit être conçue de manière à remplacer le milieu de
collecte de l’iode (voir aussi l’article 14 de la CEI 60761-1). Dans le cas des ensembles de
mesure directe, il doit être possible de placer la source en position fixe, près du détecteur.
7 Expression des résultats
Conformément aux exigences de l’article 9 de la CEI 60761-1, il convient que l'ensemble
électronique de mesure associé au détecteur fournisse normalement une lecture exprimée
directement dans l'unité d'activité volumique (Bq/m ).
Le constructeur doit indiquer le coefficient d'étalonnage et le ou les isotopes de l'iode auxquels
il s'applique.
8 Réponse à d'autres rayonnements ionisants
L'équipement de mesure doit être conçu pour réduire autant que possible l'influence des rayon-
nements ionisants autres que ceux spécifiés. Le constructeur doit spécifier, le cas échéant, les
perturbations provoquées par les autres rayonnements ionisants.
9 Discrimination de l’activité naturelle
Il est recommandé que l'équipement soit conçu (forme, détecteur, traitement) de sorte à être le
moins perturbé possible par les radionucléides naturels et leurs produits de décroissance. Si
tel n'est pas le cas, le constructeur doit indiquer l'ampleur de ces effets.
10 Conditions normales d'essai
Sauf spécification contraire, les essais doivent être considérés comme des essais de type,
mais certains d’entre eux ou tous peuvent être considérés comme des essais d’acceptation par
accord entre le constructeur et l'acheteur.
Les conditions normales d'essai sont indiquées dans le tableau 1. Elles représentent les
valeurs et les tolérances des diverses grandeurs d'influence pour les essais effectués sans
variation de ces grandeurs.
60761-4 IEC:2002 – 15 –
The contact time of the iodine with the sampling medium should be greater than 0,2 s. If the
contact time with the retention medium is less than 0,2 s (for example in a monitor with a high
sampling flow-rate), the reduced collection efficiency shall be indicated. The actual collection
efficiency shall be specified by the manufacturer and shall be agreed by the purchaser.
The manufacturer shall state how the collection efficiency is influenced by the chemical form of
iodine, atmospheric conditions and the presence of chemical products in sampled air. The
manufacturer shall specify the storage conditions of the collection medium.
5.6 Radiation detector
The manufacturer shall fully specify the detector characteristics, including the detector
dimensions and transmission characteristics such as the effective surface area of detection.
When the housing of the detector is in direct contact with the gaseous medium being
monitored, special care shall be taken in the design to facilitate decontamination of the
detector.
6 Check source
A check source should be supplied with the equipment. In the case of indirect monitoring
assemblies, this shall be designed in such a way as to replace the iodine retention medium
(see also clause 14 of IEC 60761-1). In the case of direct measuring assemblies, it shall be
possible to place the source in a fixed position close to the detector.
7 Expression of measurement
In accordance with the requirements of clause 9 of IEC 60761-1, the electronic measuring
assembly associated with the detector should normally provide a reading expressed directly in
a unit of volumic activity (Bq/m ).
The manufacturer shall state the calibration factor and the iodine isotopes for which it applies.
8 Response to other ionizing radiations
The equipment shall be designed so as to limit, as far as possible, the influence of ionizing
radiations other than those specified. The manufacturer shall specify, where applicable, the
interference effects due to other ionizing radiations.
9 Discrimination against natural activity
The design of the equipment (shape, detector, treatment) should be such that the interference
from naturally occurring radionuclides and their decay products is negligible. If this is not the
case, the manufacturer shall state the magnitude of any such effects.
10 Standard test conditions
Except where otherwise specified, tests are to be considered as type tests, although any or all
may be considered as acceptance tests by agreement between manufacturer and purchaser.
The standard test conditions are shown in Table 1. These represent the values and tolerances
of the various influence quantities for tests carried out with no variation of these values.
– 16 – 60761-4 CEI:2002
Les essais réalisés dans les conditions normales d'essai sont indiqués dans le tableau 2.
11 Essais effectués avec variation des grandeurs d'influence
Ces essais sont indiqués dans les tableaux 3 et 4. Ils doivent être effectués conformément à
l’article 24 de la CEI 60761-1.
12 Sources de référence et sources spéciales
12.1 Sources de référence
Pour déterminer la réponse de référence pendant un essai de type, la source de référence doit
être de l'air contenant une activité volumique connue en vapeur de l'isotope particulier et la
forme chimique particulière d'iode pour laquelle l'équipement est conçu. La forme chimique
peut être de l'iode moléculaire ou organique (ICH ou HIO par exemple). Une source solide
3 3
homogène d'activité connue et de mêmes caractéristiques que le milieu collecteur peut être
utilisée comme étalon de transfert.
Il convient que la source de référence soit une source du radionucléide concerné, mais la
période relativement courte de certains peut pousser à utiliser d'autres radionucléides (par
exemple du baryum 133 à la place de l'iode 131, ou de l'iode 129 à la place de l'iode 125). Le
constructeur doit conseiller l'acheteur en la matière.
12.2 Sources spéciales
Les sources utilisées pour les essais de réponse en énergie et les sources utilisées pour
produire des rayonnements perturbateurs sont définies comme des sources spéciales.
12.3 Incertitude sur l’activité des sources d’essais
L’activité volumique conventionnellement vraie de l'iode dans l'air doit être connue avec une
incertitude inférieure à ±10 % (k = 2).
Le taux d'émission surfacique, ou l’activité, conventionnellement vrai des sources solides
utilisées doit être connu avec une incertitude inférieure à ±10 % (k = 2 ).
13 Essais de performance avec des rayonnements
13.1 Réponse de référence
13.1.1 Exigence
La réponse de référence ne doit pas différer de plus de 20 % des spécifications du
constructeur.
13.1.2 Méthode d'essai
L’iode, sous la forme appropriée, doit être introduit directement dans le moniteur. L'activité
d'iode indiquée à l'équilibre ne doit pas différer de plus de 20 % de l’activité convention-
nellement vraie.
13.2 Linéarité
13.2.1 Exigence
Les exigences et méthodes d'essais décrites en 26.3 de la CEI 60761-1 sont applicables.
60761-4 IEC:2002 – 17 –
Tests carried out under standard test conditions are listed in Table 2.
11 Tests performed with variation of the influence quantities
These tests are listed in Tables 3 and 4. They shall be carried out in accordance with clause 24
of IEC 60761-1.
12 Reference and special sources
12.1 Reference sources
For the determination of the reference response during type tests, the reference source shall
be air with a known volumic activity of vapour of the particular isotope and chemical form of
iodine which the equipment is designed to measure. The chemical form may be molecular
iodine or organic iodine (e.g. ICH or HIO ). Homogeneous solid sources with known activity
3 3
and the same physical features as the collection medium may be used as transfer standards.
The reference source should be a source of the radionuclide of interest; however, because of the
relatively short half-lives of some of these, other radionuclides may be used (i.e. Barium-133
for Iodine-131 and Iodine-129 for Iodine-125). The manufacturer shall advise the purchaser
when alternatives are used.
12.2 Special sources
The sources used for tests related to energy response and those used to produce in
...








Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...