IEC 61000-4-15:2010/ISH1:2017
(Main)Interpretation Sheet 1 - Electromagnetic compatibility (EMC) - Part 4-15: Testing and measurement techniques - Flickermeter - Functional and design specifications
Interpretation Sheet 1 - Electromagnetic compatibility (EMC) - Part 4-15: Testing and measurement techniques - Flickermeter - Functional and design specifications
General Information
Relations
Standards Content (Sample)
IEC 2017
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
IEC 61000-4-15
Edition 2.0 2010-08
ELECTROMAGNETIC COMPATIBILITY (EMC) –
Part 4-15: Testing and measurement techniques –
Flickermeter – Functional and design specifications
INTERPRETATION SHEET 1
This interpretation sheet has been prepared by subcommittee 77A: EMC – Low frequency
phenomena, of IEC technical committee 77: Electromagnetic compatibility.
The text of this interpretation sheet is based on the following documents:
FDIS Report on voting
77A/966/FDIS 77A/973/RVD
Full information on the voting for the approval of this interpretation sheet can be found in the
report on voting indicated in the above table.
___________
Interpretation of requirements for rectangular voltage modulation with duty ratio
according to IEC 61000-4-15: Electromagnetic compatibility (EMC) – Testing and
measurement techniques – Flickermeter – Functional and design specifications.
IEC 61000-4-15 Ed 2 gives requirements in 6.8 for what is called “Rectangular voltage
changes with 20 % duty cycle”. Table 11 provides the test specification for rectangular voltage
changes with duty ratio. The requirements per Table 11 and th
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.