ISO/PRF 24823
(Main)Plastics — Test method for the experimental characterisation of out-of-plane permeability of fibrous reinforcements for liquid composite moulding
- Abstract
The standardisation of the test methods used to measure the out-of-plane permeability of fibrous reinforcements used in the manufacture of composite materials by liquid composite moulding. The test method details the equipment and procedure for measurement of the out-of-plane permeability, K3, at a known volume fraction.
- Status
- Not Published
- Technical Committee
- ISO/TC 61/SC 13 - Composites and reinforcement fibres
- Drafting Committee
- ISO/TC 61/SC 13/WG 1 - Reinforcements and reinforcement products
- Current Stage
- 5020 - Proof sent to secretariat or FDIS ballot initiated: 8 weeks - 50 Approval
- Start Date
- 29-Oct-2026
Buy Documents
ISO/PRF 24823 - Plastics — Test method for the experimental characterisation of out-of-plane permeability of fibrous reinforcements for liquid composite moulding
REDLINE ISO/PRF 24823 - Plastics — Test method for the experimental characterisation of out-of-plane permeability of fibrous reinforcements for liquid composite moulding
ISO/PRF 24823 is an ISO standard for the experimental characterisation of the out-of-plane permeability of fibrous reinforcements used in liquid composite moulding (LCM). It specifies the test equipment, test method and data analysis for measuring out-of-plane permeability, K3, at a known fibre volume fraction. The document is aimed at laboratories, process engineers and materials users who need comparable permeability data for LCM design and material selection.
What does ISO/PRF 24823 specify?
ISO/PRF 24823 specifies a test method for measuring out-of-plane permeability of fibrous reinforcements for LCM. It concentrates on a 1D saturated flow test, where fluid passes through the thickness of a compressed reinforcement and the result is calculated from measured pressure drop and flow rate.
| Annex | What it covers |
|---|---|
| Annex A | Informative precision data from interlaboratory comparison exercises |
The document is organized into clauses on scope, references, terms, principle, tool design, experiment design, specimen preparation, fluid preparation, measurement, method, precision and reporting. In practice, that means it tells users how to build the rig, prepare the specimen, run the test and report results in a consistent way.
What are the key requirements of ISO/PRF 24823?
ISO/PRF 24823 defines a complete procedure for producing out-of-plane permeability data that are comparable across laboratories. The main requirements are in clauses 4 to 12 and are tied directly to the way the test is built and run.
Apparatus and flow control
Clause 5 requires a rig with two rigid perforated plates, distribution chambers above and below the specimen, and sealing around the specimen edge to prevent race-tracking. The plates must keep the specimen at a uniform thickness, and no vacuum is applied to the vent. In practice, the rig has to create a controlled through-thickness flow field, otherwise the measured permeability will be distorted by edge leakage or uneven compaction.
Specimen preparation and stacking
Clause 7 requires accurate cutting, careful handling and defined reference direction and reference side for each reinforcement. The specimen size must be between 50 mm and 200 mm, and the stack orientation must be recorded. This matters because fibre orientation and edge damage directly affect flow paths and can change the measured value.
Fibre volume fraction and test conditions
Clause 6 requires repeated tests on new specimens, with at least five repeats for each test condition. The fibre volume fraction is set by mould height and layer count, and the document recommends testing several volume fractions. The pressure difference between inlet and outlet should be between 100 kPa and 200 kPa, and the test must be isothermal. In practice, users need to control compaction, pressure and temperature because permeability depends on all three.
Fluid, measurements and calculation
Clause 8 requires a quasi-Newtonian, incompressible test fluid with viscosity in the stated range, and clause 9 sets the required accuracy for pressure, temperature and flow measurements. Clause 10 then uses the measured flow rate, viscosity, plate spacing and pressure difference to calculate K by Darcy’s law. This means the laboratory must know the fluid properties at the test temperature and measure the test signals accurately enough for the calculation to be meaningful.
Reporting and precision
Clause 12 lists the information that must be reported, including reinforcement architecture, fibre type, layer count, volume fraction, sealant details, temperatures, fluid viscosity and the final K value with repeat statistics. Clause 11 points to Annex A for precision data. For users, this supports traceable reporting and helps compare results from different labs.
What terms does ISO/PRF 24823 define?
- Out-of-plane permeability - the material parameter that links through-thickness flow velocity to pressure gradient and fluid viscosity; the document refers to this component as K3.
- Saturated flow - steady flow in which all pore spaces are filled with fluid, so the flow state does not change with time.
- 1D flow - injection across the full surface area so the fluid moves through the thickness in one direction only.
- Race-tracking - locally faster flow in gaps between the specimen and the mould, which can corrupt the measured result.
- Fibrous reinforcement - the porous textile or reinforcement material being tested for its permeability in LCM use.
Who uses ISO/PRF 24823?
ISO/PRF 24823 is used by test laboratories, composite material suppliers, LCM process engineers, design teams and quality managers. They use it to measure reinforcement permeability, compare candidate materials, support process simulation and check whether a reinforcement behaves consistently from batch to batch. It is also relevant to buyers who need a documented test method for supplier qualification.
Which standards are used with ISO/PRF 24823?
- ISO 4410 - provides related terminology and the companion test method for in-plane permeability of fibrous reinforcements.
- ISO 2555 - supports viscosity-related control of the liquid state test fluid and the temperature-dependent viscosity work used in the method.
- ISO 6721-10 - supports the stated temperature measurement accuracy for the test fluid and test environment.
What does the ISO/PRF 24823 document contain?
ISO/PRF 24823 includes a schematic rig design, a permeability calculation based on Darcy’s law, and a fibre volume fraction formula used to set test conditions. It also gives requirements for specimen cutting, stacking, mass measurement, fluid preparation, pressure sensing, temperature sensing and flow-rate measurement.
Annex A provides informative precision data from interlaboratory comparison exercises, including repeatability and reproducibility statistics. The bibliography cites benchmark and support literature used in developing the method.
Buy Documents
ISO/PRF 24823 - Plastics — Test method for the experimental characterisation of out-of-plane permeability of fibrous reinforcements for liquid composite moulding
REDLINE ISO/PRF 24823 - Plastics — Test method for the experimental characterisation of out-of-plane permeability of fibrous reinforcements for liquid composite moulding
Get Certified
Connect with accredited certification bodies for this standard
DIN CERTCO
DIN Group product certification.

Smithers Quality Assessments
US management systems and product certification.
Sponsored listings
Frequently Asked Questions
ISO/PRF 24823 is a draft published by the International Organization for Standardization (ISO). Its full title is "Plastics — Test method for the experimental characterisation of out-of-plane permeability of fibrous reinforcements for liquid composite moulding". This standard covers: The standardisation of the test methods used to measure the out-of-plane permeability of fibrous reinforcements used in the manufacture of composite materials by liquid composite moulding. The test method details the equipment and procedure for measurement of the out-of-plane permeability, K3, at a known volume fraction.
The standardisation of the test methods used to measure the out-of-plane permeability of fibrous reinforcements used in the manufacture of composite materials by liquid composite moulding. The test method details the equipment and procedure for measurement of the out-of-plane permeability, K3, at a known volume fraction.
ISO/PRF 24823 is classified under the following ICS (International Classification for Standards) categories: 83.120 - Reinforced plastics. The ICS classification helps identify the subject area and facilitates finding related standards.
ISO/PRF 24823 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 out-of-plane permeability
- 3.2 saturated flow
- 3.3 1D flow
- 3.4 race-tracking
- 4 Principle
- 5 Tool design
- 5.1 Apparatus design
- 5.2 Specimen thickness control
- 6 Design of experiments
- 6.1 Number of repeat tests
- 6.2 Setting the fibre volume fraction
- 6.3 Selection of the fluid injection pressure
- 6.4 Temperature conditions
- 7 Test specimen and specimen preparation
- 7.1 Specimen cutting
- 7.2 Specimen stacking
- 7.3 Specimen mass measurement
- 8 Test fluid and fluid injection system preparation
- 8.1 Test fluid
- 8.2 Preparing the fluid and the injection system
- 9 Measurement of fluid pressure, temperature, and flow rate
- 9.1 Fluid pressure measurement
- 9.2 Fluid temperature measurement
- 9.3 Fluid flow rate measurement
- 10 Method
- 10.1 Test preparation
- 10.2 Data acquisition
- 10.3 Data processing
- 11 Precision
- 12 Test report
- Annex A
- Bibliography
Introduction
This document focuses on the measurement of the out-of-plane permeability of textile reinforcements used in the manufacture of polymer matrix composites by liquid composite moulding (LCM). Complete saturation of the textile reinforcement by the liquid resin prior to curing during LCM manufacture is critical to ensuring the desired properties are achieved in the finished part. Characterisation of the out-of-plane permeability provides crucial information on how well the liquid resin will penetrate in the through-thickness direction of the textile reinforcement, facilitating the design of the manufacturing process and aiding in material selection.
This document covers the most common method used for measuring the out-of-plane permeability, the 1D saturated test method. It uses the Darcy equation to derive the out-of-plane permeability from the measured pressure differential and flow rate of a model fluid through the specimen. PROOF/ÉPREUVE
International Standard ISO 24823:2026(en) Plastics — Test method for the experimental characterisation of out-of-plane permeability of fibrous reinforcements for liquid composite moulding
1 Scope
This document specifies the test method for the experimental characterisation of the out-of-plane permeability of fibrous reinforcements for liquid composite moulding. It gives requirements for test equipment, test method and data analysis to ensure optimal accuracy and reproducibility of the results.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 4410, Test methods for the experimental characterization of in-plane permeability of fibrous reinforcements for liquid composite moulding ISO 2555, Plastics — Resins in the liquid state or as emulsions or dispersions — Determination of apparent viscosity using a single cylinder type rotational viscometer method ISO 6721-10, Plastics — Determination of dynamic mechanical properties — Part 10: Complex shear viscosity using a parallel-plate and a cone-and-plate oscillatory rheometer
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 4410 and the following apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https:// www .iso .org/ obp
- IEC Electropedia: available at https:// www .electropedia .org/
3.1 out-of-plane permeability
K
quantitative material parameter of a fibrous reinforcement (a porous medium), relating the phase-averaged flow velocity of a liquid in the reinforcement to the applied pressure gradient and the dynamic viscosity of the fluid Note 1 to entry: The permeability is calculated using Darcy’s law:
PROOF/ÉPREUVE
ISO 24823:2026(en) K v p (1)
where v is a vector describing the phase-averaged flow velocity; K is a matrix describing the directional permeability of the reinforcement; µ is the dynamic viscosity of the (incompressible) fluid; ∇p is a flow-driving pressure gradient
Note 2 to entry: The permeability is given in units of square metres (m ). Note 3 to entry: The out-of-plane permeability is referred to as K , as a component of the tensor, K, perpendicular to
the textile plane.
Note 4 to entry: The permeability of a reinforcement depends on the fibre volume fraction and the geometrical fibre arrangement. Because of the directionality of the fibre arrangement in a reinforcement, the permeability is generally anisotropic.
3.2 saturated flow
steady-state flow in a porous medium where all pore spaces are filled with fluid Note 1 to entry: Filling state and flow velocity distribution do not change with time.
3.3 1D flow
injection of fluid through the entire surface area of a porous medium, resulting in a non-divergent flow through the thickness of the medium in one direction only
3.4 race-tracking
locally increased flow velocity in gaps between specimen and mould
4 Principle
A specimen of the textile reinforcement is compressed between two porous, parallel plates at a defined and uniform thickness. Then, a test fluid with known viscosity is injected at either constant injection pressure or constant flow rate through an inlet below the specimen. The fluid passes through a preliminary chamber below the specimen and parallel plates, of areal dimensions such that a one-dimensional flow pattern through the specimen is established. This 1D flow passes through the specimen prior to ejection through a secondary chamber and the outlet. Once the reinforcement is completely wetted and a steady-state, saturated flow has developed, the flow rate and pressure difference between the inlet and outlet side of the specimen are monitored, and the known porosity and fluid viscosity are used to calculate the out-of-plane permeability, K , with Darcy’s law.
5 Tool design
5.1 Apparatus design
The apparatus, depicted in Figure 1, shall allow the following. - A specimen made of reinforcement layers is compressed between two rigid perforated plates at uniform gap height, h. The perforated plates shall be of 10 mm minimum thick steel. It is recommended that the coverage ratio be greater than 50 %, i.e. the space for flow shall be greater than the contact surface area between the specimen and the plate. The holes shall be homogenously distributed across the plate with a recommended diameter of 5 to 10 mm.
PROOF/ÉPREUVE
ISO 24823:2026(en) - The specimen shall be enclosed in a chamber which allows for the specimen to be sealed around the edge with either an o-ring, silicone paste or grease to prevent race-tracking of the test fluid between the edges of the specimen and the walls of the enclosing chamber.
- A test fluid is injected into a distribution chamber beneath the bottom perforated plate at constant injection pressure or constant flow rate.
- Above the upper perforated plate is another distribution chamber with an exit vent for the fluid, which ensures that 1D flow is achieved.
- No vacuum is applied to the vent.
NOTE 1 If the coverage ratio is too small, compaction of the reinforcement might not be uniform, resulting in local variations in Vf. If the coverage ratio is too large, the flow field is affected significantly, and the permeability of the plates can be small enough to have a measurable effect on the outcome. NOTE 2 Silicone paste and grease are available in different viscosities. The appropriate selection will be dependent upon the design of the apparatus.
NOTE 3 At the time of publication, there is insufficient evidence to suggest a recommended number of perforations, spacing or diameter. At the location of the perforations, there can be a local variation in fibre volume fraction in the specimen.
a) Isometric view b) Cross-sectional view Key 1 fluid inlet 2 fluid outlet 3 bottom perforated plate 4 top perforated plate 5 bottom distribution chamber 6 top distribution chamber 7 test specimen Figure 1 — Schematic diagram of the rig design
5.2 Specimen thickness control
The tool shall comprise of two flat, parallel, horizontal perforated plates that contain the specimen. Adjustment of the distance between the plates shall be possible at high accuracy. Methods used for adjustment of the distance shall not interfere with the test method. The thickness can be set with the use PROOF/ÉPREUVE
ISO 24823:2026(en) of shims or spacers of known thickness. If the tool is designed to be mounted in a universal test machine (UTM), the thickness can be set via the displacement of the UTM crosshead.
...
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Principle
- 5 Tool design
- 5.1 Apparatus design
- 5.2 Specimen thickness control
- 6 Design of experiments
- 6.1 Number of repeat tests
- 6.2 Setting the fibre volume fraction
- 6.3 Selection of the fluid injection pressure
- 6.4 Temperature conditions
- 7 Test specimen and specimen preparation
- 7.1 Specimen cutting
- 7.2 Specimen stacking
- 7.3 Specimen mass measurement
- 8 Test fluid and fluid injection system preparation
- 8.1 Test fluid
- 8.2 Preparing the fluid and the injection system
- 9 Measurement of fluid pressure, temperature, and flow rate
- 9.1 Fluid pressure measurement
- 9.2 Fluid temperature measurement
- 9.3 Fluid flow rate measurement
- 10 Method
- 10.1 Test preparation
- 10.2 Data acquisition
- 10.3 Data processing
- 11 Precision
- 12 Test report
- Annex A
- Bibliography
Introduction
This document focuses on the measurement of the out-of-plane permeability of textile reinforcements used in the manufacture of polymer matrix composites by liquid composite moulding (LCM). Complete saturation of the textile reinforcement by the liquid resin prior to curing during LCM manufacture is critical to ensuring the desired properties are achieved in the finished part. Characterisation of the out-of-plane permeability provides crucial information on how well the liquid resin will penetrate in the through-thickness direction of the textile reinforcement, facilitating the design of the manufacturing process and aiding in material selection. This document covers the most common method used for measuring the out-of-plane permeability, the 1D saturated test method. It uses the Darcy equation to derive the out-of-plane permeability from the measured pressure differential and flow rate of a model fluid through the specimen.
ISO/PRF 24823:2026(en) Plastics — Test method for the experimental characterisation of outof-plane permeability of fibrous reinforcements for liquid composite moulding
1 Scope
This document specifies the test method for the experimental characterisation of the out-of-plane permeability of fibrous reinforcements for liquid composite moulding. It gives requirements for test equipment, test method and data analysis to ensure optimal accuracy and reproducibility of the results.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 4410, Test methods for the experimental characterization of in-plane permeability of fibrous reinforcements for liquid composite moulding ISO 2555, Plastics — Resins in the liquid state or as emulsions or dispersions — Determination of apparent viscosity using a single cylinder type rotational viscometer method ISO 6721--10, Plastics — Determination of dynamic mechanical properties — Part 10: Complex shear viscosity using a parallel-plate and a cone-and-plate oscillatory rheometer
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 4410 and the following apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- — ISO Online browsing platform: available at https://www.iso.org/obp
- — IEC Electropedia: available at https://www.electropedia.org/ 3.1 3.1 out-of-plane permeability K
quantitative material parameter of a fibrous reinforcement (a porous medium), relating the phase-averaged flow velocity of a liquid in the reinforcement to the applied pressure gradient and the dynamic viscosity of the fluid.
Note 1 to entry: The permeability is calculated using Darcy’s law:
𝐾𝐾 𝑣𝑣 =− ∇𝑝𝑝 (1) 𝜇𝜇 where 𝑣𝑣 is a vector describing the phase-averaged flow velocity; 𝐾𝐾 is a matrix describing the directional permeability of the reinforcement; µ is the dynamic viscosity of the (incompressible) fluid; ∇p is a flow-driving pressure gradient
ISO/PRF 24823:2026(en)
Note 2 to entry: The permeability is given in units of square metres (m ). Note 3 to entry: The out-of-plane permeability is referred to as K3, as a component of the tensor, K, perpendicular to the textile plane.
Note 4 to entry: The permeability of a reinforcement depends on the fibre volume fraction and the geometrical fibre arrangement. Because of the directionality of the fibre arrangement in a reinforcement, the permeability is generally anisotropic.
3.2 3.2 saturated flow steady-state flow in a porous medium where all pore spaces are filled with fluid Note 1 to entry: Filling state and flow velocity distribution do not change with time. 3.3 3.3 1D flow injection of fluid through the entire surface area of a porous medium, resulting in a non-divergent flow through the thickness of the medium in one direction only 3.4 3.4 race-tracking locally increased flow velocity in gaps between specimen and mould
4 Principle
A specimen of the textile reinforcement is compressed between two porous, parallel plates at a defined and uniform thickness. Then, a test fluid with known viscosity is injected at either constant injection pressure or constant flow rate through an inlet below the specimen. The fluid passes through a preliminary chamber below the specimen and parallel plates, of areal dimensions such that a one-dimensional flow pattern through the specimen is established. This 1D flow passes through the specimen prior to ejection through a secondary chamber and the outlet. Once the reinforcement is completely wetted and a steady-state, saturated flow has developed, the flow rate and pressure difference between the inlet and outlet side of the specimen are monitored, and the known porosity and fluid viscosity are used to calculate the out-of-plane permeability, K ,
with Darcy’s law.
5 Tool design
5.1 Apparatus design
The apparatus, depicted in Figure 1Figure 1,, shall allow the following:. - — A specimen made of reinforcement layers is compressed between two rigid perforated plates at uniform gap height, h. The perforated plates shall be of 10 mm minimum thick steel. It is recommended that the coverage ratio be greater than 50 %, i.e. the space for flow shall be greater than the contact surface area between the specimen and the plate. The holes shall be homogenously distributed across the plate with a recommended diameter of 5 to 10 mm.
- — The specimen shall be enclosed in a chamber which allows for the specimen to be sealed around the edge with either an o-ring, silicone paste or grease to prevent race-tracking of the test fluid between the edges of the specimen and the walls of the enclosing chamber.
- — A test fluid is injected into a distribution chamber beneath the bottom perforated plate at constant injection pressure or constant flow rate.
ISO/PRF 24823:2026(en) - — Above the upper perforated plate is another distribution chamber with an exit vent for the fluid, which ensures that 1D flow is achieved.
- — No vacuum is applied to the vent.
NOTE 1 If the coverage ratio is too small, compaction of the reinforcement maymight not be uniform, resulting in local variations in Vf. If the coverage ratio is too large, the flow field is affected significantly, and the permeability of the plates maycan be small enough to have a measurable effect on the outcome. NOTE 2 Silicone paste and grease are available in different viscosities. The appropriate selection will be dependent upon the design of the apparatus.
NOTE 3 At the time of publication, there is insufficient evidence to suggest a recommended number of perforations, spacing or diameter. At the location of the perforations, there can be a local variation in fibre volume fraction in the specimen.
a) Isometric view b) Cross-sectional view Key
ISO/PRF 24823:2026(en) 1 fluid inlet 2 fluid outlet 3 bottom perforated plate 4 top perforated plate 5 bottom distribution chamber 6 top distribution chamber 7 test specimen Figure 1 — Schematic diagram of the rig design
5.2 Specimen thickness control
The tool shall comprise of two flat, parallel, horizontal perforated plates that contain the specimen. Adjustment of the distance between the plates shall be possible at high accuracy. Methods used for adjustment of the distance shall not interfere with the test method. The thickness can be set with the use of shims or spacers of known thickness. If the tool is designed to be mounted in a universal test machine (UTM), the thickness can be set via the displacement of the UTM crosshead.
...