Abstract

This part of the IEC/IEEE 62582 series contains requirements for application of the other parts of IEC/IEEE 62582 related to specific methods for condition monitoring in electrical equipment important to safety of nuclear power plants. It also includes requirements which are common to all methods. The procedures defined in IEC/IEEE 62582 are intended for detailed condition monitoring.
IEC/IEEE 62582 specifies condition monitoring methods in sufficient detail to enhance the accuracy and repeatability, and provide standard formats for reporting the results. The methods specified are applicable to electrical equipment containing polymeric materials. Some methods are especially designed for the measurement of condition of a limited range of equipment whilst others can be applied to all types of equipment for which the polymeric parts are accessible.
Although the scope of IEC/IEEE 62582 is limited to the application of instrumentation and control systems important to safety, the condition monitoring methods can also be applicable to other components which include polymeric materials.
The different parts of IEC/IEEE 62582 are measurement standards, primarily for use in the management of ageing in initial qualification and after installation. For the technical background of condition monitoring methods, reference is made to other IEC standards, e.g. IEC 60544-5 [1]. Information on the role of condition monitoring in qualification of electrical equipment important to safety is found in IEC/IEEE 60780-323. General information on management of ageing can be found in IEC 62342 [5] and IEEE 1205 [6].
NOTE A simplified version of the procedures can be appropriate for preliminary assessment of the need for detailed measurements.

Status
Published
Public Enquiry End Date
31-Dec-2025
Publication Date
18-Jun-2026
Technical Committee
I09 - Imaginarni 09
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
09-Jun-2026
Due Date
14-Aug-2026
Completion Date
19-Jun-2026

Buy Documents

Standard

SIST EN IEC/IEEE 62582-1:2026

English language (24 pages)
Preview
Preview
e-Library read for
×1 day

SIST EN IEC/IEEE 62582-1:2026 is the Slovenian adoption of EN IEC/IEEE 62582-1:2026, which reproduces IEC/IEEE 62582-1:2024. It gives the general requirements for electrical equipment condition monitoring methods in nuclear power plants (NPPs), with a focus on instrumentation and control important to safety and on equipment that contains polymeric materials. The document is intended for operators of NPPs, systems evaluators and licensors who need repeatable measurements, trend data and standard reporting for detailed condition monitoring.

What does SIST EN IEC/IEEE 62582-1:2026 specify?

SIST EN IEC/IEEE 62582-1:2026 specifies the common requirements for the IEC/IEEE 62582 series and how the other parts are to be applied. It is a general part: it sets the framework for detailed condition monitoring, but it is not a technology-specific standard.

The standard is organised into clauses 1 to 7 and one informative annex:

  • Clause 1 - scope
  • Clause 2 - normative references
  • Clause 3 - terms and definitions
  • Clause 4 - condition indicators
  • Clause 5 - applicability of condition indicators to different types of polymeric materials
  • Clause 6 - destructive and non-destructive condition monitoring
  • Clause 7 - application of condition monitoring in equipment qualification and management of ageing
  • Annex A - diffusion limited oxidation (DLO), informative

SIST EN IEC/IEEE 62582-1:2026 applies to electrical equipment important to safety in nuclear power plants, especially equipment containing polymeric materials. The document also says the same methods can be used on other components that include polymeric materials. It does not add functional requirements for safety systems, and it is not meant to cover specific technologies.

What are the key requirements of SIST EN IEC/IEEE 62582-1:2026?

Condition indicators must track ageing in a usable way

Clause 4.1 requires a condition indicator to be measurable, to change monotonically with time, and to be linked to functional degradation of the qualified equipment. The indicator also has to show a consistent trend from the unaged state to the limit of the qualified pre-accident condition, and it is to be applied according to IEC/IEEE 60780-323.

In practice, this means the measured value has to move in one direction as ageing progresses, so the result can support prediction and decision-making. A signal that stays flat and then changes suddenly is not useful for prognostic work.

The standard groups indicators by the property they monitor

Clauses 4.2 to 4.6 group condition indicators into chemical, physical, electrical, other, and visual and tactile observation. Chemical indicators follow changes in the polymer chemistry, physical indicators follow properties such as tensile strength, elongation and hardness, and electrical indicators follow dielectric properties or changes in electrical response during normal operation.

For readers, this helps with method selection. The standard is not prescribing one test; it is describing the main families of methods and how they relate to polymer ageing.

Visual and tactile observation is a screening method

Clause 4.6 treats visual and tactile observation as non-intrusive methods for accessible components. They are used to identify cracks, discolouration, contamination, chemical or oil presence, swelling or deformation, and similar local damage.

In practice, this is a quick first check. If the inspection suggests degradation, the standard points the user to more detailed methods in the other parts of IEC/IEEE 62582.

Not every indicator fits every polymeric material

Clause 5 states that no single condition monitoring method suits all polymeric materials. A useful indicator must be sensitive to ageing effects, change monotonically with degradation, and correlate with safety-related performance.

That matters because method selection depends on the material and the equipment. The standard warns against using an indicator that responds too late or too abruptly for prognostic use, especially with some semi-crystalline materials and thermosetting resins.

Destructive and non-destructive methods are both recognised

Clause 6 distinguishes destructive and non-destructive condition monitoring. Non-destructive field use is preferred, but the standard notes that it is currently limited for some equipment types, mainly cables with accessible parts.

This means users may need deposited samples or replaceable samples when field access is limited. The choice affects installation planning, sampling strategy and whether the equipment can stay in service during testing.

Condition monitoring is used in qualification and ageing management

Clause 7.1 lists the main uses: determining acceleration factors for qualified life, extending qualified life, establishing qualified condition, and periodically checking installed equipment against the qualified condition. This ties condition monitoring directly to ageing management and equipment qualification.

Clause 7.2.2 explains that accelerated thermal ageing uses an Arrhenius-based approach to calculate the acceleration factor from activation energy. In practice, the measured condition indicator values at different temperatures are used to estimate the ageing rate, so accuracy and repeatability are important because small errors in activation energy strongly affect qualified life.

Clause 7.4 explains condition-based qualification: the qualified condition is established from incremental pre-ageing measurements, then compared with periodic post-installation measurements on representative samples. The acceptance criteria in the plant have to leave enough time to replace equipment before the qualified condition is exceeded.

Annex A explains diffusion limited oxidation

Annex A gives background on diffusion limited oxidation (DLO), which can make oxidation non-uniform through the thickness of a polymer part. This is especially important in thicker parts and when high acceleration factors are used during accelerated ageing.

For users, Annex A helps explain why measured ageing results can differ between the surface and the interior of a sample. It also identifies profiling methods and gives a theoretical approach for estimating when DLO may occur.

What terms does SIST EN IEC/IEEE 62582-1:2026 define?

  • Condition indicator - A measurable characteristic used to infer or directly indicate the current and future ability of a structure, system or component to meet acceptance criteria.
  • Condition monitoring - Continuous or periodic testing, inspection, measurement or trending used to indicate current or future performance and the potential for failure.
  • Equipment qualification - The generation and maintenance of evidence that equipment will operate on demand under specified service conditions and meet system performance requirements.
  • Equipment important to safety - Equipment whose failure could lead to undue radiation exposure or that is needed to prevent or mitigate unsafe conditions.
  • Qualified condition - The condition of equipment before a design basis event, when it has been shown to meet the design requirements for the specified service conditions.
  • Qualified life - The period for which a structure, system or component has been shown, by testing, analysis or experience, to function within acceptance criteria while retaining its safety function in accident conditions.
  • Service conditions - The actual physical states or influences during the service life of equipment, including normal, abnormal, design basis event, post-event and design extension conditions.

Who uses SIST EN IEC/IEEE 62582-1:2026?

SIST EN IEC/IEEE 62582-1:2026 is intended for operators of nuclear power plants, systems evaluators and licensors. It is also used by teams responsible for equipment qualification, ageing management, condition monitoring and post-installation assessment of electrical equipment important to safety.

In practice, these users apply the standard when they need to justify qualified life, compare installed equipment against a qualified condition, choose a monitoring method for polymeric parts, or document repeatable results in a standard format.

What changed in SIST EN IEC/IEEE 62582-1:2026 from the previous edition?

SIST EN IEC/IEEE 62582-1:2026 is the second edition and it replaces the first edition published in 2011. The standard states two significant technical changes:

  • it integrates experience from IAEA-TECDOC-1825:2017 on condition monitoring test techniques for low-voltage cables in nuclear power plants
  • it refers to IEC/IEEE 60780-323 instead of IEC 60780 and IEEE 323

Which standards are used with SIST EN IEC/IEEE 62582-1:2026?

  • IEC/IEEE 60780-323 - Provides the qualification framework that this part uses for condition indicators, qualified condition and qualified life.
  • IEC/IEEE 62582 (all parts) - The series of method-specific standards that this general part supports.
  • IEC 60544-5 - Gives technical background on assessment of ageing in service by radiation-related procedures.
  • IEC 62342 - Provides general information on management of ageing.
  • IEEE 1205 - Provides guidance on assessing, monitoring and mitigating ageing effects on electrical equipment.

What does the SIST EN IEC/IEEE 62582-1:2026 document contain?

The document explains the main classes of condition indicators and how they relate to polymer ageing in electrical equipment important to safety. It also describes how to use those indicators in qualification, life extension and condition-based qualification.

It includes figures showing an Arrhenius diagram, the effect of activation energy on qualified life, and the principle of condition-based qualification. Annex A adds background on DLO, including its effect on thermal ageing and the methods used to profile oxidation through a sample.

The bibliography points to supporting work on cable ageing, ageing management, and related IEC, IAEA and IEEE documents.

Relations

Effective Date
09-Jun-2026
Effective Date
09-Jun-2026
Effective Date
09-Jun-2026
Effective Date
19-May-2026
Effective Date
03-Feb-2026

Buy Documents

Standard

SIST EN IEC/IEEE 62582-1:2026

English language (24 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

DNV

DNV is an independent assurance and risk management provider.

NA Norway Verified

Lloyd's Register

Lloyd's Register is a global professional services organisation specialising in engineering and technology.

UKAS United Kingdom Verified

DNV Energy Systems

Energy and renewable energy certification.

NA Norway Verified

Sponsored listings

Frequently Asked Questions

SIST EN IEC/IEEE 62582-1:2026 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Nuclear power plants - Instrumentation and control important to safety - Electrical equipment condition monitoring methods - Part 1: General (IEC/IEEE 62582-1:2024)". This standard covers: This part of the IEC/IEEE 62582 series contains requirements for application of the other parts of IEC/IEEE 62582 related to specific methods for condition monitoring in electrical equipment important to safety of nuclear power plants. It also includes requirements which are common to all methods. The procedures defined in IEC/IEEE 62582 are intended for detailed condition monitoring. IEC/IEEE 62582 specifies condition monitoring methods in sufficient detail to enhance the accuracy and repeatability, and provide standard formats for reporting the results. The methods specified are applicable to electrical equipment containing polymeric materials. Some methods are especially designed for the measurement of condition of a limited range of equipment whilst others can be applied to all types of equipment for which the polymeric parts are accessible. Although the scope of IEC/IEEE 62582 is limited to the application of instrumentation and control systems important to safety, the condition monitoring methods can also be applicable to other components which include polymeric materials. The different parts of IEC/IEEE 62582 are measurement standards, primarily for use in the management of ageing in initial qualification and after installation. For the technical background of condition monitoring methods, reference is made to other IEC standards, e.g. IEC 60544-5 [1]. Information on the role of condition monitoring in qualification of electrical equipment important to safety is found in IEC/IEEE 60780-323. General information on management of ageing can be found in IEC 62342 [5] and IEEE 1205 [6]. NOTE A simplified version of the procedures can be appropriate for preliminary assessment of the need for detailed measurements.

This part of the IEC/IEEE 62582 series contains requirements for application of the other parts of IEC/IEEE 62582 related to specific methods for condition monitoring in electrical equipment important to safety of nuclear power plants. It also includes requirements which are common to all methods. The procedures defined in IEC/IEEE 62582 are intended for detailed condition monitoring. IEC/IEEE 62582 specifies condition monitoring methods in sufficient detail to enhance the accuracy and repeatability, and provide standard formats for reporting the results. The methods specified are applicable to electrical equipment containing polymeric materials. Some methods are especially designed for the measurement of condition of a limited range of equipment whilst others can be applied to all types of equipment for which the polymeric parts are accessible. Although the scope of IEC/IEEE 62582 is limited to the application of instrumentation and control systems important to safety, the condition monitoring methods can also be applicable to other components which include polymeric materials. The different parts of IEC/IEEE 62582 are measurement standards, primarily for use in the management of ageing in initial qualification and after installation. For the technical background of condition monitoring methods, reference is made to other IEC standards, e.g. IEC 60544-5 [1]. Information on the role of condition monitoring in qualification of electrical equipment important to safety is found in IEC/IEEE 60780-323. General information on management of ageing can be found in IEC 62342 [5] and IEEE 1205 [6]. NOTE A simplified version of the procedures can be appropriate for preliminary assessment of the need for detailed measurements.

SIST EN IEC/IEEE 62582-1:2026 is classified under the following ICS (International Classification for Standards) categories: 27.120.20 - Nuclear power plants. Safety. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN IEC/IEEE 62582-1:2026 has the following relationships with other standards: It is inter standard links to SIST EN IEC/IEEE 62582-4:2026, SIST EN IEC/IEEE 62582-3:2026, SIST EN IEC/IEEE 62582-2:2026, SIST EN IEC/IEEE 62582-6:2021, SIST EN 60780-323:2017. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN IEC/IEEE 62582-1:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 condition indicator
  • 3.2 condition monitoring
  • 3.3 equipment qualification
  • 3.4 equipment important to safety
  • 3.5 tactile observation
  • 3.6 visual observation
  • 3.7 qualified condition
  • 3.8 qualified life
  • 3.9 service life
  • 3.10 design basis events
  • 3.11 service conditions
  • 3.12 ageing
  • 3.13 accelerated ageing
  • 4 Condition indicators
  • 4.1 General
  • 4.2 Chemical indicators
  • 4.3 Physical indicators
  • 4.4 Electrical indicators
  • 4.5 Other indicators
  • 4.6 Visual and tactile observation
  • 5 Applicability of condition indicators to different types of polymeric materials
  • 6 Destructive and non-destructive condition monitoring
  • 7 Application of condition monitoring in equipment qualification and
  • 7.1 General
  • 7.2 Use of condition monitoring in the establishment of qualified life
  • 7.3 Use of condition monitoring in the extension of qualified life
  • 7.4 Use of condition monitoring in the establishment and assessment of qualified
  • 7.5 Use of baseline data
  • Annex A
  • Bibliography

INTRODUCTION a) Technical background, main issues and organisation of this document This part of this IEC/IEEE 62582 series focuses on methods for condition monitoring for management of ageing of electrical equipment installed in nuclear power plants and for application of the concept of qualified condition.

IEC/IEEE 6258-1 is the first part of the IEC/IEEE 62582 series of standards, containing background and guidelines for the application of methods for condition monitoring of electrical equipment important to safety of nuclear power plants. The detailed descriptions of the methods are given in the other parts, one part for each method. This document also includes some elements which are common to all methods.

IEC/IEEE 62582 series is issued with a joint logo which makes it applicable to the management of ageing of electrical equipment qualified to IEEE as well as IEC Standards. Condition monitoring is a developing field and more methods will be added to the IEC/IEEE 62582 series when they are considered widely applied and a good reproducibility of the condition monitoring method can be demonstrated.

IEC/IEEE 60780-323 defined condition-based qualification which is an adjunct to type testing. The qualified condition is established by condition indicator(s) prior to the start of accident conditions for which the equipment was demonstrated to meet the design requirements for the specified service conditions. IEC/IEEE 60780-323 defined condition indicator. Significant research has been performed on condition monitoring techniques and the use of these techniques in equipment qualification as noted in NUREG/CR-6704, Vol. 2

(BNL -NUREG-52610) [1], JNES-SS-0903, 2009 [2] and IAEA-TECDOC-1825:2017 [3]. It is intended that this IEC/IEEE document be used by operators of nuclear power plants, systems evaluators and by licensors.

b) Situation of the current standard in the structure of the IEC SC 45A standard series IEC/IEEE 62582-1 is the third level IEC SC 45A document tackling the issue of application of condition monitoring in equipment qualification and management of ageing of electrical I&C equipment in nuclear power plants.

IEC/IEEE 62582-1 is to be read in association with IEC/IEEE 60780-323, which provides general requirements for qualification of I&C systems and equipment that are used to perform functions important to safety in NPPs and nuclear facilities.

For more details on the structure of the IEC SC 45A standard series, see item d) of this introduction.

c) Recommendations and limitations regarding the application of this document It is important to note that this document establishes no additional functional requirements for safety systems.

This document discusses the general measurement technique for current condition monitoring methods and is not meant to cover any specific technologies.

Numbers in square brackets refer to the Bibliography.

SIST EN IEC/IEEE 62582-1:2026

d) Description of the structure of the IEC SC 45A standard series and relationships with other IEC documents and other bodies documents (IAEA, ISO) The IEC SC 45A standard series comprises a hierarchy of four levels. The top-level documents of the IEC SC 45A standard series are IEC 61513 and IEC 63046. IEC 61513 provides general requirements for instrumentation and control (I&C) systems and equipment that are used to perform functions important to safety in nuclear power plants (NPPs). IEC 63046 provides general requirements for electrical power systems of NPPs; it covers power supply systems including the supply systems of the I&C systems. IEC 61513 and IEC 63046 are to be considered in conjunction and at the same level. IEC 61513 and IEC 63046 structure the IEC SC 45A standard series and shape a complete framework establishing general requirements for instrumentation, control and electrical power systems for nuclear power plants.

IEC 61513 and IEC 63046 refer directly to other IEC SC 45A standards for general requirements for specific topics, such as categorization of functions and classification of systems, qualification, separation, defence against common cause failure, control room design, electromagnetic compatibility, human factors engineering, cybersecurity, software and hardware aspects for programmable digital systems, coordination of safety and security requirements and management of ageing. The standards referenced directly at this second level should be considered together with IEC 61513 and IEC 63046 as a consistent document set. At a third level, IEC SC 45A standards not directly referenced by IEC 61513 or by IEC 63046 are standards related to specific requirements for specific equipment, technical methods, or activities. Usually these documents, which make reference to second-level documents for general requirements, can be used on their own.

A fourth level extending the IEC SC 45 standard series, corresponds to the Technical Reports which are not normative.

The IEC SC 45A standards series consistently implements and details the safety and security principles and basic aspects provided in the relevant IAEA safety standards and in the relevant documents of the IAEA nuclear security series (NSS). In particular this includes the IAEA requirements SSR-2/1 , establishing safety requirements related to the design of nuclear power plants (NPPs), the IAEA safety guide SSG-30 dealing with the safety classification of structures, systems and components in NPPs, the IAEA safety guide SSG-39 dealing with the design of instrumentation and control systems for NPPs, the IAEA safety guide SSG-34 dealing with the design of electrical power systems for NPPs, the IAEA safety guide SSG-51 dealing with human factors engineering in the design of NPPs and the implementing guide NSS42-G for computer security at nuclear facilities. The safety and security terminology and definitions used by the SC 45A standards are consistent with those used by the IAEA.

IEC 61513 and IEC 63046 have adopted a presentation format similar to the basic safety publication IEC 61508 with an overall life-cycle framework and a system life-cycle framework. Regarding nuclear safety, IEC 61513 and IEC 63046 provide the interpretation of the general requirements of IEC 61508-1, IEC 61508-2 and IEC 61508-4, for the nuclear application sector. In this framework, IEC 60880, IEC 62138 and IEC 62566 correspond to IEC 61508-3 for the nuclear application sector.

IEC 61513 and IEC 63046 refer to ISO 9001 as well as to IAEA GSR part 2 and IAEA GS-G-3.1 and IAEA GS-G-3.5 for topics related to quality assurance (QA).

SIST EN IEC/IEEE 62582-1:2026

At level 2, regarding nuclear security, IEC 62645 is the entry document for the IEC/SC 45A security standards. It builds upon the valid high level principles and main concepts of the generic security standards, in particular ISO/IEC 27001 and ISO/IEC 27002; it adapts them and completes them to fit the nuclear context and coordinates with the IEC 62443 series. At level 2, IEC 60964 is the entry document for the IEC SC 45A control rooms standards, IEC 63351 is the entry document for the human factors engineering standards and IEC 62342 is the entry document for the ageing management standards.

NOTE 1 It is assumed that for the design of I&C systems in NPPs that implement conventional safety functions (e.g. to address worker safety, asset protection, chemical hazards, process energy hazards) international or national standards would be applied.

NOTE 2 IEC TR 63400 provides a more comprehensive description of the overall structure of the IEC SC 45A standards series and of its relationship with other standards bodies and standards.

SIST EN IEC/IEEE 62582-1:2026

NUCLEAR POWER PLANTS – INSTRUMENTATION AND CONTROL IMPORTANT TO SAFETY – ELECTRICAL EQUIPMENT CONDITION MONITORING METHODS –

Part 1: General

1 Scope

This part of the IEC/IEEE 62582 series contains requirements for application of the other parts of IEC/IEEE 62582 related to specific methods for condition monitoring in electrical equipment important to safety of nuclear power plants. It also includes requirements which are common to all methods. The procedures defined in IEC/IEEE 62582 are intended for detailed condition monitoring.

IEC/IEEE 62582 specifies condition monitoring methods in sufficient detail to enhance the accuracy and repeatability, and provide standard formats for reporting the results. The methods specified are applicable to electrical equipment containing polymeric materials. Some methods are especially designed for the measurement of condition of a limited range of equipment whilst others can be applied to all types of equipment for which the polymeric parts are accessible. Although the scope of IEC/IEEE 62582 is limited to the application of instrumentation and control systems important to safety, the condition monitoring methods can also be applicable to other components which include polymeric materials.

The different parts of IEC/IEEE 62582 are measurement standards, primarily for use in the management of ageing in initial qualification and after installation. For the technical background of condition monitoring methods, reference is made to other IEC standards, e.g. IEC 60544-5 [1]. Information on the role of condition monitoring in qualification of electrical equipment important to safety is found in IEC/IEEE 60780-323. General information on management of ageing can be found in IEC 62342 [5] and IEEE 1205 [6]. NOTE A simplified version of the procedures can be appropriate for preliminary assessment of the need for detailed measurements.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

IEC/IEEE 60780-323, Nuclear facilities – Electrical equipment important to safety – Qualification IEC/IEEE 62582 (all parts), Nuclear power plants – Instrumentation and control important to safety – Electrical equipment condition monitoring methods

SIST EN IEC/IEEE 62582-1:2026

3 Terms and definitions

For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • IEC Electropedia: available at https://www.electropedia.org/
  • ISO Online browsing platform: available at https://www.iso.org/obp
  • IEEE Standards Dictionary Online: available at http://dictionary.ieee.org

3.1 condition indicator

characteristic of a structure, system or component that can be observed, measured or trended to infer or directly indicate the current and future ability of the structure, system or component to function within acceptance criteria [SOURCE: IAEA Nuclear Safety and Security Glossary, 2022 (Interim) Edition]

3.2 condition monitoring

continuous or periodic tests, inspections, measurement or trending of the performance or physical characteristics of structures, systems and components to indicate current or future performance and the potential for failure [SOURCE: IAEA Safety Glossary, 2018 Edition, modified – note removed.]

3.3 equipment qualification

generation and maintenance of evidence to ensure that equipment will operate on demand, under specified service conditions, to meet system performance requirements [SOURCE: IAEA Nuclear Safety and Security Glossary, 2022 (Interim) Edition, modified – notes not included.]

3.4 equipment important to safety

equipment that is part of a safety group and/or whose malfunction or failure could lead to undue radiation exposure of the site personnel or members of the public. Equipment including:

  • those structures, systems and components that prevent anticipated operational occurrences from leading to accident conditions;
  • those features that are provided to mitigate the consequences of malfunction or failure of structures, systems and components.

Note 1 to entry:

a) For usage consistent with IEC 61226 [11], equipment important to safety are as follows:

1) all I&C equipment performing Category A to Category C functions (in accordance with the IEC 61226 [11] categorisation scheme); 2) all electrical equipment necessary to ensure emergency energy supply to this equipment in case of a loss of normal power supply; 3) all electrical equipment necessary to ensure ultimate energy supply in case of total loss of on-site power (if selected as design extension condition to be mitigated).

SIST EN IEC/IEEE 62582-1:2026

b) For usage consistent with other IEEE documents and a Class 1E categorization; for equipment important to safety, qualification is essential to the following:

1) electric equipment and systems that are essential to emergency reactor shutdown, containment isolation, reactor core cooling, and containment and reactor heat removal, or; 2) electric equipment that are otherwise essential in preventing significant release of radioactive material to the environment.

...