SIST EN IEC/IEEE 62582-4:2026
(Main)Nuclear power plants - Instrumentation and control important to safety - Electrical equipment condition monitoring methods - Part 4: Oxidation induction techniques (IEC/IEEE 62582-4:2022)
- Abstract
This part of IEC/IEEE 62582 specifies methods for condition monitoring of organic and polymeric materials in instrumentation and control systems using oxidation induction techniques in the detail necessary to produce accurate and reproducible measurements. It includes the requirements for sample preparation, the measurement system and conditions, and the reporting of the measurement results.
The different parts of IEC/IEEE 62582 are measurement standards, primarily for use in the management of ageing in initial qualification and after installation. IEC/IEEE 62582-1 includes requirements for the application of the other parts of the IEC/IEEE 62582 series and some elements which are common to all methods. Information on the role of condition monitoring in the qualification of equipment important to safety is found in IEC/IEEE 60780-323.
- Status
- Published
- Public Enquiry End Date
- 31-Dec-2025
- Publication Date
- 18-Jun-2026
- Technical Committee
- I09 - Imaginarni 09
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 09-Jun-2026
- Due Date
- 14-Aug-2026
- Completion Date
- 19-Jun-2026
SIST EN IEC/IEEE 62582-4:2026 is the Slovenian adoption of EN IEC/IEEE 62582-4:2026, carrying IEC/IEEE 62582-4:2022. It specifies oxidation induction techniques for condition monitoring of organic and polymeric materials in instrumentation and control systems important to safety in nuclear power plants. The document is aimed at test laboratories, nuclear power plant operators, systems evaluators, and licensors.
What does SIST EN IEC/IEEE 62582-4:2026 specify?
SIST EN IEC/IEEE 62582-4:2026 specifies how to measure oxidation induction time (OIT) and oxidation induction temperature (OITP) so the results are accurate and reproducible. It covers the sample, the instrument, the measurement conditions, and the reporting of results.
The document is organized into:
- Clause 1 - Scope
- Clause 2 - Normative references
- Clause 3 - Terms and definitions
- Clause 4 - Abbreviated terms and acronyms
- Clause 5 - General description
- Clause 6 - Applicability and reproducibility
- Clause 7 - Measurement procedure
- Annexes A to C - interpretation, reporting example, and temperature influence
| Annex | What it covers |
|---|---|
| Annex A | Interpretation of OIT and OITP thermograms |
| Annex B | Example measurement reports for OITP and OIT |
| Annex C | Influence of set temperature on the OIT value |
The scope is focused on laboratory measurement of samples taken from equipment, not on field measurement in the plant. The standard is intended primarily for ageing management in initial qualification and after installation.
What are the key requirements of SIST EN IEC/IEEE 62582-4:2026?
SIST EN IEC/IEEE 62582-4:2026 sets out the practical conditions needed to make OIT and OITP results comparable. The main requirements are in Clause 7, with interpretation and reporting guidance in the annexes.
Sampling, storage, and preparation
Clause 7.1 says newly manufactured polymeric materials should be allowed to stabilise before condition monitoring or accelerated ageing work begins. If the manufacturer’s stabilisation time is not available, a period of 6 months is used.
Clause 7.2 requires sampling locations to be chosen from representative plant areas and documented together with the environmental history of the location. In practice, this means the sample must be tied to a known operating environment, because OIT and OITP describe only the place that was sampled.
Clause 7.2 and 7.3 require clean samples, no solvent cleaning, and careful handling of dual-layer materials. The report must make it clear how a sample was taken, because mixed layers can change the measured value.
Sample mass and repeat measurements
Clause 7.2 says a minimum of 50 mg is needed to allow up to 5 measurements on one sample, while Clause 7.3 sets the test portion at 5 mg ± 1 mg, or 10 mg ± 1 mg for some older, less sensitive equipment. The sample pieces must be small and uniformly prepared, so the oxidation response is reproducible.
Clause 7.3 also requires at least 3 measurements. If the spread is too large, 2 more measurements should be taken if enough material is available, and the highest and lowest values are discarded before calculating the mean of the remaining three. This gives a more stable result when the material is inhomogeneous.
Instrumentation and calibration
Clause 7.4 requires an instrument capable of detecting sub-milliwatt exotherms, such as a differential scanning calorimeter (DSC), simultaneous thermal analyzer (STA), or differential thermal analyzer (DTA). It must hold temperature stable within ± 0.3 °C and allow controlled gas purging. For OIT work, the gas-switching dead time should be under 1 minute.
Clause 7.5 requires calibration with a suitable standard for the temperature range used, and a reference sample must be measured before each batch. In practice, this is how the laboratory checks that the temperature and measurement system are still valid before reporting ageing data.
OIT measurement method
Clause 7.6 defines OIT as an isothermal oxygen test. The sample is heated in nitrogen, held at the set temperature, and then exposed to oxygen while the heat flow is monitored until oxidation begins.
For OIT, the set temperature is 210 °C if the OIT for unaged material is at least 30 min. If the value is outside the target range, the temperature is adjusted in 10 °C steps and then kept constant for that material in later measurements. Oxygen flow is 75 ml∙min ± 25 ml∙min, and the onset is taken at 0.1 W∙g relative to the chosen baseline. In practice, that means the laboratory must use one consistent thermal history for a given material if it wants comparable ageing data.
OITP measurement method and reporting
Clause 7.7 defines OITP as a dynamic test in oxygen with a heating rate of 10 °C∙min. The onset is taken at 0.5 W∙g relative to the baseline, and the temperature at which oxidation starts is reported.
Both OIT and OITP reports must identify the sample, its prehistory, the sampling method, the instrument and software, the calibration method, the pan type, gas flow, temperature profile, baseline choice, onset choice, number of samples, and the mean with standard deviation. This matters because the result is only meaningful if another laboratory can understand exactly how it was produced.
What terms does SIST EN IEC/IEEE 62582-4:2026 define?
SIST EN IEC/IEEE 62582-4:2026 defines the key terms needed to interpret the measurements and the acronyms used throughout the document.
- Oxidation induction time (OIT) - the time to the onset of exothermic oxidation at a specified temperature in oxygen, expressed in minutes.
- Oxidation induction temperature (OITP) - the temperature at which exothermic oxidation begins during a programmed temperature rise in oxygen, expressed in degrees Celsius.
- Differential scanning calorimeter (DSC) - an instrument named in the document as suitable for detecting the oxidation exotherm.
- Simultaneous thermal analyzer (STA) - an instrument named in the document as suitable for oxidation induction measurements.
- Ethylene propylene rubber (EPR) - one of the material families listed as suitable for the method.
- Cross-linked polyethylene (XLPE) - one of the material families specifically mentioned for cable jackets and insulation.
Who uses SIST EN IEC/IEEE 62582-4:2026?
SIST EN IEC/IEEE 62582-4:2026 is used by test laboratories, nuclear power plant operators, systems evaluators, and licensors. It is relevant to people who manage ageing of cable jackets, insulation, and other polymeric materials in instrumentation and control systems important to safety.
In practice, users apply it to qualification work, post-installation monitoring, and laboratory assessment of removed samples. Quality and engineering staff use it to compare ageing state, document sampling history, and produce reports that can be reviewed across sites and laboratories.
What changed in SIST EN IEC/IEEE 62582-4:2026 from the previous edition?
SIST EN IEC/IEEE 62582-4:2026 is the second edition and it cancels and replaces the first edition published in 2011. The document states these significant changes:
- consideration of IEC/IEEE 60780-323
- an example added in Annex B and updated
- Annex C added
These changes matter because they link the method more clearly to equipment qualification, improve reporting examples, and add guidance on how set temperature affects the OIT value.
Which standards are used with SIST EN IEC/IEEE 62582-4:2026?
SIST EN IEC/IEEE 62582-4:2026 is intended to be read with IEC/IEEE 62582-1, which gives the general requirements and common elements for the IEC/IEEE 62582 series. The introduction also points to IEC/IEEE 60780-323, which addresses the role of condition monitoring in qualification of equipment important to safety.
The bibliography names ISO 11357-6 for oxidation induction time and oxidation induction temperature measurements by DSC, IEC 60544-5 for ageing assessment procedures for electrical insulating materials, and related background references from IAEA, JNES, and NUREG. These references help users align this nuclear standard with broader thermal analysis and ageing practice.
What does the SIST EN IEC/IEEE 62582-4:2026 document contain?
SIST EN IEC/IEEE 62582-4:2026 contains two full measurement procedures, one for OIT and one for OITP, each with its temperature profile, gas flow, baseline choice, onset definition, and reporting items. It also includes schematic figures for the test profiles and the onset definition.
Annex A gives practical examples of thermogram interpretation, including flat baselines, sloping baselines, multiple onsets, and endothermic features. Annex B gives example measurement reports for OITP and OIT, which is useful when building laboratory report templates. Annex C shows how the selected set temperature changes the OIT value, which helps laboratories choose a consistent test condition for a material family.
Relations
- Effective Date
- 09-Jun-2026
Get Certified
Connect with accredited certification bodies for this standard

DNV
DNV is an independent assurance and risk management provider.

Lloyd's Register
Lloyd's Register is a global professional services organisation specialising in engineering and technology.

DNV Energy Systems
Energy and renewable energy certification.
Sponsored listings
Frequently Asked Questions
SIST EN IEC/IEEE 62582-4:2026 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Nuclear power plants - Instrumentation and control important to safety - Electrical equipment condition monitoring methods - Part 4: Oxidation induction techniques (IEC/IEEE 62582-4:2022)". This standard covers: This part of IEC/IEEE 62582 specifies methods for condition monitoring of organic and polymeric materials in instrumentation and control systems using oxidation induction techniques in the detail necessary to produce accurate and reproducible measurements. It includes the requirements for sample preparation, the measurement system and conditions, and the reporting of the measurement results. The different parts of IEC/IEEE 62582 are measurement standards, primarily for use in the management of ageing in initial qualification and after installation. IEC/IEEE 62582-1 includes requirements for the application of the other parts of the IEC/IEEE 62582 series and some elements which are common to all methods. Information on the role of condition monitoring in the qualification of equipment important to safety is found in IEC/IEEE 60780-323.
This part of IEC/IEEE 62582 specifies methods for condition monitoring of organic and polymeric materials in instrumentation and control systems using oxidation induction techniques in the detail necessary to produce accurate and reproducible measurements. It includes the requirements for sample preparation, the measurement system and conditions, and the reporting of the measurement results. The different parts of IEC/IEEE 62582 are measurement standards, primarily for use in the management of ageing in initial qualification and after installation. IEC/IEEE 62582-1 includes requirements for the application of the other parts of the IEC/IEEE 62582 series and some elements which are common to all methods. Information on the role of condition monitoring in the qualification of equipment important to safety is found in IEC/IEEE 60780-323.
SIST EN IEC/IEEE 62582-4:2026 is classified under the following ICS (International Classification for Standards) categories: 27.120.20 - Nuclear power plants. Safety. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN IEC/IEEE 62582-4:2026 has the following relationships with other standards: It is inter standard links to SIST EN IEC/IEEE 62582-1:2026. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN IEC/IEEE 62582-4:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 Oxidation induction time
- 3.2 Oxidation induction temperature
- 4 Abbreviated terms and acronyms
- 5 General description
- 6 Applicability and reproducibility
- 7 Measurement procedure
- 7.1 Stabilisation of the polymeric materials
- 7.2 Sampling
- 7.3 Sample preparation
- 7.4 Instrumentation
- 7.5 Calibration
- 7.6 OIT measurement method
- 7.7 OITP measurement method
- Annex A
- Annex B
- Annex C
- Bibliography
INTRODUCTION a) Technical background, main issues and organisation of this standard This part of IEC/IEEE 62582 specifically focuses on oxidation induction methods for condition monitoring for the management of ageing of electrical equipment installed in nuclear power plants. The methods are primarily suited to samples taken from materials that are polyolefinbased, but they can also be used for some materials based on ethylene-propylene polymers and for some ethylene vinyl acetate materials.
This part 4 of IEC/IEEE 62582 is the fourth part of the IEC/IEEE 62582 series. IEC/IEEE 62582 series is issued with a joint logo which makes it applicable to the management of ageing of electrical equipment qualified to IEEE as well as IEC Standards. IEC/IEEE 60780-323 includes the concept and role that condition based qualification could be used in equipment qualification as an adjunct to qualified life. In equipment qualification, the condition of the equipment for which acceptable performance was demonstrated is the qualified condition. The qualified condition is the condition of equipment, prior to the start of a design basis event, for which the equipment was demonstrated to meet the design requirements for the specified service conditions.
Significant research has been performed on condition monitoring techniques and the use of these techniques in equipment qualification as noted in NUREG/CR-6704, Vol. 2 (BNL-NUREG- 52610) JNES-SS-0903, 2009 and IAEA-TECDOC-1825:2017.
It is intended that this document be used by test laboratories, operators of nuclear power plants, systems evaluators, and licensors.
b) Situation of the current standard in the structure of the IEC SC 45A standard series IEC/IEEE 62582-4 is the third level IEC SC 45A document tackling the specific issue of application and performance of oxidation induction measurements in the management of ageing of electrical instrument and control equipment in nuclear power plants. IEC/IEEE 62582-4 is to be read in association with IEC/IEEE 62582-1, which provides background and guidelines for the application of methods for condition monitoring of electrical equipment important to safety of nuclear power plants.
For more details on the structure of the IEC SC 45A standard series, see item d) of this introduction.
c) Recommendations and limitations regarding the application of this standard It is important to note that this document establishes no additional functional requirements for safety systems.
d) Description of the structure of the IEC SC45A standard series and relationships with other IEC documents and other bodies documents (IAEA, ISO) The IEC SC 45A standard series comprises a hierarchy of four levels. The top-level documents of the IEC SC 45A standard series are IEC 61513 and IEC 63046. IEC 61513 provides general requirements for instrumentation and control (I&C) systems and equipment that are used to perform functions important to safety in nuclear power plants (NPPs). IEC 63046 provides general requirements for electrical power systems of NPPs; it covers power supply systems including the supply systems of the I&C systems.
SIST EN IEC/IEEE 62582-4:2026
IEC 61513 and IEC 63046 are to be considered in conjunction and at the same level. IEC 61513 and IEC 63046 structure the IEC SC 45A standard series and shape a complete framework establishing general requirements for instrumentation, control and electrical power systems for nuclear power plants.
IEC 61513 and IEC 63046 refer directly to other IEC SC 45A standards for general requirements for specific topics, such as categorization of functions and classification of systems, qualification, separation, defence against common cause failure, control room design, electromagnetic compatibility, human factors engineering, cybersecurity, software and hardware aspects for programmable digital systems, coordination of safety and security requirements and management of ageing. The standards referenced directly at this second level should be considered together with IEC 61513 and IEC 63046 as a consistent document set. At a third level, IEC SC 45A standards not directly referenced by IEC 61513 or by IEC 63046 are standards related to specific requirements for specific equipment, technical methods, or activities. Usually these documents, which make reference to second-level documents for general requirements, can be used on their own.
A fourth level extending the IEC SC 45 standard series, corresponds to the Technical Reports which are not normative.
The IEC SC 45A standards series consistently implements and details the safety and security principles and basic aspects provided in the relevant IAEA safety standards and in the relevant documents of the IAEA nuclear security series (NSS). In particular this includes the IAEA requirements SSR-2/1 , establishing safety requirements related to the design of nuclear power plants (NPPs), the IAEA safety guide SSG-30 dealing with the safety classification of structures, systems and components in NPPs, the IAEA safety guide SSG-39 dealing with the design of instrumentation and control systems for NPPs, the IAEA safety guide SSG-34 dealing with the design of electrical power systems for NPPs, the IAEA safety guide SSG-51 dealing with human factors engineering in the design of NPPs and the implementing guide NSS17 for computer security at nuclear facilities. The safety and security terminology and definitions used by the SC 45A standards are consistent with those used by the IAEA.
IEC 61513 and IEC 63046 have adopted a presentation format similar to the basic safety publication IEC 61508 with an overall life-cycle framework and a system life-cycle framework. Regarding nuclear safety, IEC 61513 and IEC 63046 provide the interpretation of the general requirements of IEC 61508-1, IEC 61508-2 and IEC 61508-4, for the nuclear application sector. In this framework, IEC 60880, IEC 62138 and IEC 62566 correspond to IEC 61508-3 for the nuclear application sector.
IEC 61513 and IEC 63046 refer to ISO 9001 as well as to IAEA GSR part 2 and IAEA GS-G-3.1 and IAEA GS-G-3.5 for topics related to quality assurance (QA). At level 2, regarding nuclear security, IEC 62645 is the entry document for the IEC/SC 45A security standards. It builds upon the valid high level principles and main concepts of the generic security standards, in particular ISO/IEC 27001 and ISO/IEC 27002; it adapts them and completes them to fit the nuclear context and coordinates with the IEC 62443 series. At level 2, IEC 60964 is the entry document for the IEC/SC 45A control rooms standards, IEC 63351 is the entry document for the human factors engineering standards and IEC 62342 is the entry document for the ageing management standards.
NOTE 1 It is assumed that for the design of I&C systems in NPPs that implement conventional safety functions (e.g. to address worker safety, asset protection, chemical hazards, process energy hazards) international or national standards would be applied.
NOTE 2 IEC TR 64000 provides a more comprehensive description of the overall structure of the IEC SC 45A standards series and of its relationship with other standards bodies and standards.
SIST EN IEC/IEEE 62582-4:2026
NUCLEAR POWER PLANTS – INSTRUMENTATION AND CONTROL IMPORTANT TO SAFETY – ELECTRICAL EQUIPMENT CONDITION MONITORING METHODS –
Part 4: Oxidation induction techniques
1 Scope
This part of IEC/IEEE 62582 specifies methods for condition monitoring of organic and polymeric materials in instrumentation and control systems using oxidation induction techniques in the detail necessary to produce accurate and reproducible measurements. It includes the requirements for sample preparation, the measurement system and conditions, and the reporting of the measurement results.
The different parts of IEC/IEEE 62582 are measurement standards, primarily for use in the management of ageing in initial qualification and after installation. IEC/IEEE 62582-1 includes requirements for the application of the other parts of the IEC/IEEE 62582 series and some elements which are common to all methods. Information on the role of condition monitoring in the qualification of equipment important to safety is found in IEC/IEEE 60780-323.
2 Normative references
There are no normative references in this document.
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply. ISO, IEC and IEEE maintain terminological databases for use in standardization at the following addresses:
- IEC Electropedia: available at http://www.electropedia.org/
- ISO Online browsing platform: available at http://www.iso.org/obp
- IEEE Standards Dictionary Online: available at http://dictionary.ieee.org
3.1 Oxidation induction time
OIT relative measure of a stabilised material’s resistance to oxidative decomposition, determined by the calorimetric measurement of the time interval to the onset of exothermic oxidation of the material at a specified temperature in an oxygen atmosphere, under atmospheric pressure Note 1 to entry: OIT is expressed in minutes (min).
3.2 Oxidation induction temperature
OITP calorimetric measurement of the temperature of the onset of exothermic oxidation of the material when subjected to a specified heating rate in an oxygen atmosphere, under atmospheric pressure Note 1 to entry: OITP is expressed in degrees Celsius (°C).
SIST EN IEC/IEEE 62582-4:2026
4 Abbreviated terms and acronyms
CSPE chlorosulphonated polyethylene DSC differential scanning calorimeter EPDM ethylene propylene diene monomer EPR ethylene propylene rubber EVA ethylene vinyl acetate OIT oxidation induction time OITP oxidation induction temperature PE polyethylene PEEK poly ether ether ketone PVC poly vinyl chloride STA simultaneous thermal analyzer XLPE cross-linked polyethylene
5 General description
Oxidation induction methods are based on the detection of the oxidation exotherm that occurs when a sample is heated in the presence of oxygen. This exotherm is sensitive to the level of degradation in some organic and polymeric materials and can be used as an indicator of ageing. There are two oxidation induction methods available, based on the time required to reach the onset of oxidation at a constant temperature (oxidation induction time – OIT) or based on the temperature at the onset of oxidation during a constant temperature ramp rate (oxidation induction temperature – OITP). The two methods are complementary, in that OITP is often effective in those materials where OIT is difficult to determine. OIT and OITP decrease with increasing degradation. The methods are generally related to the amount of antioxidants present in the material. As degradation proceeds, these antioxidants are depleted. For material without antioxidants OIT is not suitable, but OITP may give a useful result. In general, OIT and OITP are used to measure the thermal stability of polymers under isothermal (OIT) and dynamic (OITP) heating conditions in oxygen.
6 Applicability and reproducibility
The oxidation induction method is primarily suited to samples taken from materials (such as cable jackets or insulation) that are polyolefin-based (e.g. PE, XLPE). It can also be used for some materials based on ethylene-propylene polymers (e.g. EPR, EPDM) and for some ethylene vinyl acetate (EVA) materials. Oxidation Induction techniques may not be applicable to high temperature polymers in some cases. It is not applicable to high temperature polymers, such as PEEK. The method can be applied to other materials but problems with interpretation of the results may reduce the effectiveness of the test.
The method is generally not suitable for chlorinated polymers (e.g. PVC, CSPE) because of the corrosive degradation products evolved during the measurements, which can damage the instrument. For these materials, smaller sample masses (1 mg to 2 mg) may enable the method to be used with care. In addition, some modern systems are designed with features that protect the equipment from volatile off gases. To determine if the equipment is protected or if additional protective components are needed, consult the equipment manufacturer. The method is not suitable for field use in the nuclear power plant but uses samples taken from the plant, which are then measured in the laboratory. Each OIT measurement in the laboratory can take up to 90 min to complete for unaged samples, decreasing for heavily aged samples, whereas OITP measurements typically take 30 min to 40 min.
SIST EN IEC/IEEE 62582-4:2026
...