Abstract

This part of IEC/IEEE 62582 contains methods for condition monitoring of organic and polymeric materials in instrumentation and control systems using the indenter measurement technique in the detail necessary to produce accurate and reproducible measurements. It includes the requirements for the selection of samples, the measurement system and measurement conditions, and the reporting of the measurement results.
The different parts of IEC/IEEE 62582 are measurement standards, primarily for use in the management of ageing in initial qualification and after installation. IEC/IEEE 62582-1 includes requirements for the application of the other parts of the IEC/IEEE 62582 series and some elements which are common to all methods. Information on the role of condition monitoring in the qualification of equipment important to safety is found in IEC/IEEE 60780-323.
This document is intended for application to non-energised equipment.

Status
Published
Public Enquiry End Date
31-Dec-2025
Publication Date
18-Jun-2026
Technical Committee
I09 - Imaginarni 09
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
09-Jun-2026
Due Date
14-Aug-2026
Completion Date
19-Jun-2026

Buy Documents

Standard

SIST EN IEC/IEEE 62582-2:2026

English language (24 pages)
Preview
Preview
e-Library read for
×1 day

SIST EN IEC/IEEE 62582-2:2026 is the Slovenian adoption of the IEC/IEEE method for indenter measurements used to monitor the condition of organic and polymeric materials in nuclear power plant instrumentation and control systems important to safety. It specifies how to select samples, set up and calibrate the measurement system, control measurement conditions, and report results so the measurements are accurate and reproducible. The method is intended for non-energised equipment and is used mainly in ageing management, initial qualification, and after-installation checks.

What does SIST EN IEC/IEEE 62582-2:2026 specify?

SIST EN IEC/IEEE 62582-2:2026 specifies the indenter measurement technique for condition monitoring of organic and polymeric materials in instrumentation and control systems for nuclear power plants. The document is written for measurements that must be repeatable and comparable, which matters in practice when results are used to judge ageing, compare locations, or support qualification decisions.

The scope also sets clear boundaries. SIST EN IEC/IEEE 62582-2:2026 is intended for non-energised equipment, and it does not add functional requirements for safety systems.

The document is organised into seven clauses and two informative annexes.

AnnexWhat it covers
Annex AExamples showing factors that change indenter modulus, including construction variability, temperature effects, and drying out after high-temperature ageing
Annex BExample of a laboratory measurement report for indenter measurements

The main clauses cover the scope, references, terms, abbreviations, the general method, applicability and reproducibility, and the measurement procedure.

What are the key requirements of SIST EN IEC/IEEE 62582-2:2026?

SIST EN IEC/IEEE 62582-2:2026 focuses on getting one thing right: measuring indenter modulus in a way that reflects the condition of the material rather than the setup, temperature, or handling. In practice, that means careful control of where, how, and under what conditions the measurement is made.

Where the method applies

  • Clause 5 describes the method as a probe-driven measurement that uses force and displacement to calculate indenter modulus. This matters because the result comes from the slope of the force-displacement curve, not from a visual judgement.
  • Clause 6 says ageing of organic and polymeric materials often changes hardness, which is why the method is used to estimate degradation level and ageing rate.
  • Clause 6.2 says the method is commonly used on cables, especially jackets and insulation, and on O-rings. For the reader, this means fixtures and access planning may be different for each geometry.
  • Clause 6.2 also says the method should be used only for materials whose hardness changes monotonically with ageing. That is important because a non-monotonic material response can make the measurement hard to interpret.
  • Clause 6.2 limits field use to measurements on accessible exterior surfaces and requires justification if jacket measurements are used to infer cable insulation condition.

How measurements are controlled

  • Clause 7.1 requires time for recently manufactured polymeric materials to stabilise before condition monitoring or accelerated ageing work. If no manufacturer data are available, a 6 month period should be allowed.
  • Clause 7.2 requires the choice of sampling and measurement locations to reflect the plant environment history, especially proximity to heat and radiation sources. In practice, the user needs to document where the sample came from and why that location was selected.
  • Clause 7.3 requires clean surfaces, forbids solvent cleaning, and sets laboratory conditions at (20 ± 5) °C and 45 % to 75 % relative humidity. If field conditions differ, temperature at the measurement surface has to be recorded.
  • Clause 7.4 fixes the probe shape as a truncated steel cone and describes the instrument as a probe, load cell, displacement transducer, clamp, and controller. This matters because the geometry and sensor chain affect comparability between instruments.
  • Clause 7.5 requires calibration before each series of measurements, with force sensor and probe velocity checked. The force error must stay below 3 % of the upper limit of the force range, and velocity error below 2 %, so the result is not dominated by instrument error.

How the measurement itself is performed

  • Clause 7.6 requires several measurement points at each selected location and reporting of the mean value and standard deviation. For cables, the document requires multiple points around the circumference at three longitudinal positions, which helps capture local variation.
  • Clause 7.6 also says that if more than seven points are measured, the highest and lowest values are removed before calculating the mean and standard deviation. This reduces the influence of outliers.
  • Clause 7.7 sets the probe velocity at 5 mm·min to 5.2 mm·min and requires the selected velocity to be reported. It also discusses maximum force as a compromise between resolution and avoiding damage.
  • Clause 7.8 says cables should be clamped with the minimum force needed to hold them in place, and the clamping method should be consistent. This matters because clamp force can change the measured modulus.
  • Clause 7.9 defines indenter modulus from the slope of the force-displacement curve using the force interval 1 N to 4 N. The practical point is that the user must calculate the same way every time, or the results will not be comparable.

What the report has to contain

  • Clause 7.10 requires the report to identify the equipment and material formulation, record prehistory, place and date, temperature, instrument and software version, calibration, measurement points, probe velocity, maximum force, clamping, any field deviations, and the mean value with standard deviation.
  • Clause 7.10 also recommends reporting the value normalised to 20 °C when measurements are made above 25 °C. That helps compare field results with laboratory or qualified-condition values.

What terms does SIST EN IEC/IEEE 62582-2:2026 define?

SIST EN IEC/IEEE 62582-2:2026 defines the key measurement term and uses a set of abbreviations that matter in reports and setup notes.

  • Indenter modulus (IM) - the ratio of the change in applied force to the corresponding displacement of the probe driven into the material; it is the main result of the method.
  • Design basis event (DBE) - the event basis used in qualification discussions when comparing the measured condition with required performance.
  • Silicone rubber (SiR) - a polymer material named in the document because it may need a lower maximum force to avoid excessive penetration.
  • Chlorosulphonated polyethylene (CSPE) - a cable jacket or insulation material used in the examples in Annex A and Annex B.
  • Ethylene propylene diene monomer (EPDM) - another polymeric cable material used in the examples and common in cable ageing work.
  • Crosslinked polyethylene (XLPE) - a cable insulation material used in the examples to show temperature dependence.
  • IEC/IEEE 62582-1 - the general part of the series that gives the common rules for applying the 62582 measurement standards.

Who uses SIST EN IEC/IEEE 62582-2:2026?

SIST EN IEC/IEEE 62582-2:2026 is intended for test laboratories, operators of nuclear power plants, systems evaluators, and licensors. These users need a common way to measure ageing-related changes in cables, O-rings, and other polymeric parts important to safety.

In practice, the document supports initial qualification work and after-installation condition monitoring. It is also useful when a plant team needs to compare field measurements with laboratory ageing results and document the basis for a qualified condition.

What changed in SIST EN IEC/IEEE 62582-2:2026 from the previous edition?

SIST EN IEC/IEEE 62582-2:2026 is the second edition of IEC/IEEE 62582-2. It cancels and replaces the first edition published in 2011 and Amendment 1:2016.

The foreword identifies two significant technical changes:

  • modification of the title
  • consideration of the publication of IEC/IEEE 60780-323

Which standards are used with SIST EN IEC/IEEE 62582-2:2026?

SIST EN IEC/IEEE 62582-2:2026 is meant to be read with related documents in the same qualification and ageing-management area.

  • IEC/IEEE 62582-1 - provides the general requirements for applying the 62582 series and the common elements shared by the measurement methods.
  • IEC/IEEE 60780-323 - explains the role of condition monitoring in the qualification of equipment important to safety.
  • IEC 60544-5 - appears in the bibliography as related background on assessing ageing in service of electrical insulating materials.
  • NUREG/CR-6704, Vol. 2, JNES-SS-0903:2009, IAEA-TECDOC-1188:2000, and IAEA-TECDOC-1825:2017 - provide research and benchmark background on cable ageing and condition monitoring techniques.

What does the SIST EN IEC/IEEE 62582-2:2026 document contain?

SIST EN IEC/IEEE 62582-2:2026 contains the measurement framework, the calculation method, and the reporting items needed to use indenter measurements consistently. It also includes a figure for probe geometry, a figure for penetration depth, and a figure showing how the indenter modulus is calculated from the force-displacement curve.

Annex A gives worked examples showing how equipment construction, temperature, and drying out can change measured values. Annex B provides a sample laboratory report and an example force-versus-time trace, which are useful when building test records or laboratory forms.

The document therefore serves three practical tasks: planning measurements, performing them under controlled conditions, and recording them in a report that other reviewers can understand and compare.

Relations

Effective Date
09-Jun-2026

Buy Documents

Standard

SIST EN IEC/IEEE 62582-2:2026

English language (24 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

DNV

DNV is an independent assurance and risk management provider.

NA Norway Verified

Lloyd's Register

Lloyd's Register is a global professional services organisation specialising in engineering and technology.

UKAS United Kingdom Verified

DNV Energy Systems

Energy and renewable energy certification.

NA Norway Verified

Sponsored listings

Frequently Asked Questions

SIST EN IEC/IEEE 62582-2:2026 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Nuclear power plants - Instrumentation and control important to safety - Electrical equipment condition monitoring methods - Part 2: Indenter measurements (IEC/IEEE 62582-2:2022)". This standard covers: This part of IEC/IEEE 62582 contains methods for condition monitoring of organic and polymeric materials in instrumentation and control systems using the indenter measurement technique in the detail necessary to produce accurate and reproducible measurements. It includes the requirements for the selection of samples, the measurement system and measurement conditions, and the reporting of the measurement results. The different parts of IEC/IEEE 62582 are measurement standards, primarily for use in the management of ageing in initial qualification and after installation. IEC/IEEE 62582-1 includes requirements for the application of the other parts of the IEC/IEEE 62582 series and some elements which are common to all methods. Information on the role of condition monitoring in the qualification of equipment important to safety is found in IEC/IEEE 60780-323. This document is intended for application to non-energised equipment.

This part of IEC/IEEE 62582 contains methods for condition monitoring of organic and polymeric materials in instrumentation and control systems using the indenter measurement technique in the detail necessary to produce accurate and reproducible measurements. It includes the requirements for the selection of samples, the measurement system and measurement conditions, and the reporting of the measurement results. The different parts of IEC/IEEE 62582 are measurement standards, primarily for use in the management of ageing in initial qualification and after installation. IEC/IEEE 62582-1 includes requirements for the application of the other parts of the IEC/IEEE 62582 series and some elements which are common to all methods. Information on the role of condition monitoring in the qualification of equipment important to safety is found in IEC/IEEE 60780-323. This document is intended for application to non-energised equipment.

SIST EN IEC/IEEE 62582-2:2026 is classified under the following ICS (International Classification for Standards) categories: 27.120.20 - Nuclear power plants. Safety. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN IEC/IEEE 62582-2:2026 has the following relationships with other standards: It is inter standard links to SIST EN IEC/IEEE 62582-1:2026. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN IEC/IEEE 62582-2:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 indenter modulus
  • 4 Abbreviated terms and acronyms
  • 5 General description
  • 6 Applicability, reproducibility and complexity
  • 6.1 General
  • 6.2 Applicability
  • 6.3 Reproducibility
  • 6.4 Complexity
  • 7 Measurement procedure
  • 7.1 Stabilisation of the polymeric materials
  • 7.2 Sampling and measurement locations
  • 7.3 Conditions for measurement
  • 7.4 Instrumentation
  • 7.5 Calibration and tolerances
  • 7.6 Selection of measurement points
  • 7.7 Selection of probe velocity and maximum force
  • 7.8 Clamping
  • 7.9 Determination of the value of the indenter modulus
  • 7.10 Reporting
  • Annex A
  • Annex B
  • Bibliography

INTRODUCTION a) Technical background, main issues and organisation of this standard This part of IEC/IEEE 62582 specifically focuses on indenter modulus methods for condition monitoring for the management of ageing of electrical equipment installed in nuclear power plants. The indenter method is commonly used to carry out measurements on cables (jackets, insulation) and O-rings.

This part 2 of IEC/IEEE 62582 contains detailed descriptions of condition monitoring based on indenter modulus measurements.

The IEC/IEEE 62582 series is issued with a joint logo which makes it applicable to the management of ageing of electrical equipment qualified to IEEE as well as IEC Standards. IEC/IEEE 60780-323 includes the concept and role that condition based qualification could be used in equipment qualification as an adjunct to qualified life. In equipment qualification, the condition of the equipment for which acceptable performance was demonstrated is the qualified condition. The qualified condition is the condition of equipment, prior to the start of a design basis event, for which the equipment was demonstrated to meet the design requirements for the specified service conditions.

Significant research has been performed on condition monitoring techniques and the use of these techniques in equipment qualification as noted in NUREG/CR-6704, Vol. 2 (BNL-NUREG-52610) and JNES-SS-0903, 2009 and IAEA-TECDOC-1825:2017. It is intended that this IEC/IEEE document be used by test laboratories, operators of nuclear power plants, systems evaluators, and licensors.

b) Situation of the current standard in the structure of the IEC SC 45A standard series IEC/IEEE 62582-2 is the third level IEC SC 45A document tackling the specific issue of application and performance of indenter modulus measurements in management of ageing of electrical instrument and control equipment in nuclear power plants. IEC/IEEE 62582-2 is to be read in association with IEC/IEEE 62582-1, which provides background and guidelines for the application of methods for condition monitoring of electrical equipment important to safety of nuclear power plants.

For more details on the structure of the IEC SC 45A standard series, see item d) of this introduction.

c) Recommendations and limitations regarding the application of this standard It is important to note that this document establishes no additional functional requirements for safety systems.

d) Description of the structure of the IEC SC 45A standard series and relationships with other IEC documents and other bodies documents (IAEA, ISO) The IEC SC 45A standard series comprises a hierarchy of four levels. The top-level documents of the IEC SC 45A standard series are IEC 61513 and IEC 63046. IEC 61513 provides general requirements for instrumentation and control (I&C) systems and equipment that are used to perform functions important to safety in nuclear power plants (NPPs). IEC 63046 provides general requirements for electrical power systems of NPPs; it covers power supply systems including the supply systems of the I&C systems.

SIST EN IEC/IEEE 62582-2:2026

IEC 61513 and IEC 63046 are to be considered in conjunction and at the same level. IEC 61513 and IEC 63046 structure the IEC SC 45A standard series and shape a complete framework establishing general requirements for instrumentation, control and electrical power systems for nuclear power plants.

IEC 61513 and IEC 63046 refer directly to other IEC SC 45A standards for general requirements for specific topics, such as categorization of functions and classification of systems, qualification, separation, defence against common cause failure, control room design, electromagnetic compatibility, human factors engineering, cybersecurity, software and hardware aspects for programmable digital systems, coordination of safety and security requirements and management of ageing. The standards referenced directly at this second level should be considered together with IEC 61513 and IEC 63046 as a consistent document set. At a third level, IEC SC 45A standards not directly referenced by IEC 61513 or by IEC 63046 are standards related to specific requirements for specific equipment, technical methods, or activities. Usually these documents, which make reference to second-level documents for general requirements, can be used on their own.

A fourth level extending the IEC SC 45 standard series, corresponds to the Technical Reports which are not normative.

The IEC SC 45A standards series consistently implements and details the safety and security principles and basic aspects provided in the relevant IAEA safety standards and in the relevant documents of the IAEA nuclear security series (NSS). In particular this includes the IAEA requirements SSR-2/1 , establishing safety requirements related to the design of nuclear power plants (NPPs), the IAEA safety guide SSG-30 dealing with the safety classification of structures, systems and components in NPPs, the IAEA safety guide SSG-39 dealing with the design of instrumentation and control systems for NPPs, the IAEA safety guide SSG-34 dealing with the design of electrical power systems for NPPs, the IAEA safety guide SSG-51 dealing with human factors engineering in the design of NPPs and the implementing guide NSS17 for computer security at nuclear facilities. The safety and security terminology and definitions used by the SC 45A standards are consistent with those used by the IAEA.

IEC 61513 and IEC 63046 have adopted a presentation format similar to the basic safety publication IEC 61508 with an overall life-cycle framework and a system life-cycle framework. Regarding nuclear safety, IEC 61513 and IEC 63046 provide the interpretation of the general requirements of IEC 61508-1, IEC 61508-2 and IEC 61508-4, for the nuclear application sector. In this framework, IEC 60880, IEC 62138 and IEC 62566 correspond to IEC 61508-3 for the nuclear application sector.

IEC 61513 and IEC 63046 refer to ISO 9001 as well as to IAEA GSR part 2 and IAEA GS-G-3.1 and IAEA GS-G-3.5 for topics related to quality assurance (QA). At level 2, regarding nuclear security, IEC 62645 is the entry document for the IEC/SC 45A security standards. It builds upon the valid high level principles and main concepts of the generic security standards, in particular ISO/IEC 27001 and ISO/IEC 27002; it adapts them and completes them to fit the nuclear context and coordinates with the IEC 62443 series. At level 2, IEC 60964 is the entry document for the IEC/SC 45A control rooms standards, IEC 63351 is the entry document for the human factors engineering standards and IEC 62342 is the entry document for the ageing management standards.

NOTE 1 It is assumed that for the design of I&C systems in NPPs that implement conventional safety functions (e.g. to address worker safety, asset protection, chemical hazards, process energy hazards) international or national standards would be applied.

NOTE 2 IEC TR 64000 provides a more comprehensive description of the overall structure of the IEC SC 45A standards series and of its relationship with other standards bodies and standards.

SIST EN IEC/IEEE 62582-2:2026

NUCLEAR POWER PLANTS – INSTRUMENTATION AND CONTROL IMPORTANT TO SAFETY – ELECTRICAL EQUIPMENT CONDITION MONITORING METHODS –

Part 2: Indenter measurements

1 Scope

This part of IEC/IEEE 62582 contains methods for condition monitoring of organic and polymeric materials in instrumentation and control systems using the indenter measurement technique in the detail necessary to produce accurate and reproducible measurements. It includes the requirements for the selection of samples, the measurement system and measurement conditions, and the reporting of the measurement results.

The different parts of IEC/IEEE 62582 are measurement standards, primarily for use in the management of ageing in initial qualification and after installation. IEC/IEEE 62582-1 includes requirements for the application of the other parts of the IEC/IEEE 62582 series and some elements which are common to all methods. Information on the role of condition monitoring in the qualification of equipment important to safety is found in IEC/IEEE 60780-323. This document is intended for application to non-energised equipment.

2 Normative references

There are no normative references in this document.

3 Terms and definitions

For the purposes of this document, the following terms and definitions apply. ISO, IEC and IEEE maintain terminological databases for use in standardization at the following addresses:

  • IEC Electropedia: available at http://www.electropedia.org/
  • ISO Online browsing platform: available at http://www.iso.org/obp
  • IEEE Standards Dictionary Online: available at http://dictionary.ieee.org

3.1 indenter modulus

ratio between the changes in applied force and corresponding displacement of a probe of a standardised shape, driven into a material

Note 1 to entry: It is expressed in N∙mm .

Note 2 to entry: The term “modulus” typically refers to the modulus of elasticity of a material which is defined as

the ratio of the applied stress and the corresponding strain and is expressed in N∙m (Pa). However, in the use of the indenter, it has become common practice to use the term indenter modulus to describe the ratio of the change in

applied force to material deformation and express it in N∙mm .

SIST EN IEC/IEEE 62582-2:2026

4 Abbreviated terms and acronyms

DBE design basis event IM indenter modulus SiR silicone rubber CSPE chlorosulphonated polyethylene EPDM ethylene propylene diene monomer XLPE crosslinked polyethylene

5 General description

A typical indenter uses an instrumented probe, which is driven at a fixed velocity into the material and includes a load cell or similar force-measuring device, connected to the probe, which measures the force necessary to maintain the constant velocity. The probe’s displacement is measured by an appropriate transducer. The travel and force are purposely limited to protect the material from permanent damage. The indenter modulus is calculated by dividing the change in force by the corresponding displacement during inward travel.

6 Applicability, reproducibility and complexity

6.1 General

When organic and polymeric materials age, they often harden which will result in an increase of indenter modulus. Some materials, such as some formulations of butyl rubber, soften during thermal and/or radiation ageing. The purpose of monitoring changes in indenter modulus is to estimate degradation rates and levels induced by ageing.

6.2 Applicability

The indenter method is commonly used to carry out measurements on cables (jackets, insulation) and O-rings. Its use requires special fixtures depending on the geometry of the samples.

This method should only be applied to materials whose hardness changes monotonically with ageing.

The indenter method can be carried out on equipment with high integrity in a non-invasive manner. However, the process of performing indenter measurements on equipment in field should include controls to ensure that damage – from the probe or from handling in order to access suitable measurement points – has not been imparted to the equipment. The process should include correction of any equipment that has been damaged or suspected of incurring damage.

Measurements in the field require access to the exterior wall of the equipment. For field measurements on cables, this often limits the measurements to jacket materials. It can be possible to assess the condition of cable insulation from indenter measurements on its jacket if there is a known relationship between the ageing degradation of the jacket material and the degradation of the insulation. This relationship shall be justified to be valid and sufficiently sensitive to provide the valid monitoring through the life of the test object.