Abstract

This part of IEC/IEEE 62582 contains methods for condition monitoring of organic and polymeric materials in instrumentation and control systems using tensile elongation techniques in the detail necessary to produce accurate and reproducible measurements. This document includes the requirements for selection of samples, the measurement system and conditions, and the reporting of the measurement results.
The different parts of IEC/IEEE 62582 are measurement standards, primarily for use in the management of ageing in initial qualification and after installation. IEC/IEEE 62582-1 includes requirements for the application of the other parts of IEC/IEEE 62582 and some elements which are common to all methods. Information on the role of condition monitoring in qualification of equipment important to safety is found in IEC/IEEE 60780-323.
This document is applicable to non-energised equipment.

Status
Published
Public Enquiry End Date
31-Dec-2025
Publication Date
18-Jun-2026
Technical Committee
I09 - Imaginarni 09
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
09-Jun-2026
Due Date
14-Aug-2026
Completion Date
19-Jun-2026

Buy Documents

Standard

SIST EN IEC/IEEE 62582-3:2026

English language (27 pages)
Preview
Preview
e-Library read for
×1 day

SIST EN IEC/IEEE 62582-3:2026 is the Slovenian adoption of EN IEC/IEEE 62582-3:2026, based on IEC/IEEE 62582-3:2024. It specifies a laboratory tensile-elongation method for condition monitoring of organic and polymeric materials in instrumentation and control important to safety in nuclear power plants. The document covers sample selection, specimen preparation, test conditions and reporting for non-energised equipment.

What does SIST EN IEC/IEEE 62582-3:2026 specify?

SIST EN IEC/IEEE 62582-3:2026 specifies how to measure elongation at break on organic and polymeric materials taken from nuclear power plant instrumentation and control equipment. The method is for ageing management work and is written to give accurate and reproducible laboratory results.

The scope is limited to tensile elongation techniques and to non-energised equipment. The introduction also makes clear that the document does not add new functional requirements for safety systems.

The document is organized into:

  • Clause 1, scope
  • Clause 2, references
  • Clause 3, terms and definitions
  • Clause 4, general description
  • Clause 5, applicability and reproducibility
  • Clause 6, measurement procedure and report
  • Annexes A to E, which support specimen preparation, test interpretation and reporting
AnnexWhat it covers
Annex AShape and dimensions of dumb-bell, tubular and O-ring test specimens
Annex BPreparation of test specimens from cable samples
Annex CTypical load versus elongation curves
Annex DDies for cutting dumb-bell specimens
Annex EExample of a measurement report

What are the key requirements of SIST EN IEC/IEEE 62582-3:2026?

SIST EN IEC/IEEE 62582-3:2026 gives a complete laboratory procedure, from stabilising the material to reporting the results. The practical point is that ageing comparisons only make sense when the same specimen type, preparation method, test speed and calculation method are used consistently.

  • Clause 4 - what is measured: the specimen is stretched at constant speed until it breaks, while load and elongation are recorded. The standard uses elongation at break because some polymeric materials can keep similar strength while elongation drops after ageing.
  • Clause 5 - where the method fits: the method is mainly suited to samples from polymer-based equipment and is generally not suitable for fibre reinforced polymeric materials or epoxides. It is a laboratory method on samples taken from plant equipment, so it supports ageing decisions rather than field measurements.
  • Clause 6.1 and 6.2 - stabilisation and sampling: newly manufactured polymeric materials need time to stabilise before ageing or monitoring starts, and sampling locations should represent a range of ageing conditions, including severe locations such as hotspots. In practice, this means the sample plan and the plant history at each location need to be documented.
  • Clause 6.2.2 - number and storage of specimens: a specific sample should normally provide at least 5 test specimens, and samples should be stored dark, cool and within a controlled humidity range before testing. This helps reduce changes between sampling and measurement.
  • Clause 6.3, Annex A, Annex B and Annex D - specimen preparation: the same specimen geometry and preparation method shall be used for baseline and aged comparisons. Dumb-bell specimens are preferred where possible, tubular specimens are used for small-diameter cable insulation, O-rings may also be used, and Annex D gives the cutter form for dumb-bell preparation.
  • Clause 6.4 - test machine and calibration: the tensile test machine must measure load and grip separation during continuous stretching, and its calibration must be traceable to a national measurement standard. If an extensometer is used, it must be non-contacting, and the same elongation method must be used for aged and unaged samples.
  • Clause 6.5 - conditioning, clamping, speed and calculation: specimens are conditioned before testing, clamped to avoid slip, and tested at the same speed for the same material. The clause also gives the elongation-at-break calculations for dumb-bell and tubular specimens and a separate calculation for O-rings.
  • Clause 6.5.6 and 6.6 - statistics and reporting: the arithmetic mean and standard deviation are required, while specimens that fail in the grips or slip out of the grips are reported separately and excluded from the mean. The report must identify the sample, its history, specimen details, instrument, calibration, speed, calculation basis and the individual results.

What terms does SIST EN IEC/IEEE 62582-3:2026 define?

SIST EN IEC/IEEE 62582-3:2026 defines the terms that control how elongation results are measured and compared.

  • Elongation (E) - tensile strain, expressed as a percentage of the test length, produced in a piece by tensile stress.
  • Elongation at break (Eb) - tensile strain in the test length at the breaking point; this is the main measured parameter in the standard.
  • Nominal elongation at break - tensile strain, expressed as a percentage of the specimen length between the grips, produced at the breaking point.
  • Gauge length - the initial distance between the gauge marks on the central part of the test specimen.
  • Test speed - the rate of separation of the gripping jaws, expressed in mm/min.

Who uses SIST EN IEC/IEEE 62582-3:2026?

SIST EN IEC/IEEE 62582-3:2026 is intended for test laboratories, operators of nuclear power plants, systems evaluators and licensors. In practice, these users need a repeatable way to compare aged and unaged polymeric materials from equipment important to safety.

It is used for ageing management in initial qualification and after installation. Plant staff use it to select sample locations, laboratories use it to prepare and test specimens, and evaluators use the results as evidence about the condition of polymeric materials.

What changed in SIST EN IEC/IEEE 62582-3:2026 from the previous edition?

SIST EN IEC/IEEE 62582-3:2026 replaces the first edition published in 2012. The document states that this second edition is a technical revision.

The stated changes are:

  • updated best practices for condition monitoring using the tensile elongation method
  • updated bibliography, references and context

Which standards are used with SIST EN IEC/IEEE 62582-3:2026?

SIST EN IEC/IEEE 62582-3:2026 has no normative references, but it is intended to be read with related companion and background standards.

StandardContribution
IEC/IEEE 62582-1Gives the general requirements for applying the other parts of the IEC/IEEE 62582 series and the common elements shared by the methods
IEC/IEEE 60780-323Provides the role of condition monitoring in qualification of equipment important to safety and defines condition-based qualification and condition indicator
ISO 37:2017Source for the terms elongation and elongation at break
ISO 527-1:2019Source for the terms gauge length and test speed
IEC 60811-501Cited as a method reference for trimming uneven cable samples with a cutting machine
IEC 60544-5Cited in the bibliography for ageing in service assessment
IEC 61508 (all parts)Background safety standard referenced in the wider IEC SC 45A framework

What does the SIST EN IEC/IEEE 62582-3:2026 document contain?

SIST EN IEC/IEEE 62582-3:2026 contains the full tensile-elongation measurement procedure, the calculation approach and the reporting content. It also includes practical annexes that show how to prepare and test the specimens.

The document contains:

  • Table 1 for test speeds by specimen type
  • Annex A figures and dimensions for dumb-bell, tubular and O-ring specimens
  • Annex B guidance for preparing specimens from large-diameter cables, small-diameter cables and bonded materials
  • Annex C typical load-elongation and load-time curves
  • Annex D cutters for dumb-bell specimens
  • Annex E an example measurement report

For users, these annexes are the working part of the standard: they show how to prepare the specimen, how to interpret the curve, and what to put in the report so that results can be compared later.

Relations

Effective Date
09-Jun-2026

Buy Documents

Standard

SIST EN IEC/IEEE 62582-3:2026

English language (27 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

DNV

DNV is an independent assurance and risk management provider.

NA Norway Verified

Lloyd's Register

Lloyd's Register is a global professional services organisation specialising in engineering and technology.

UKAS United Kingdom Verified

DNV Energy Systems

Energy and renewable energy certification.

NA Norway Verified

Sponsored listings

Frequently Asked Questions

SIST EN IEC/IEEE 62582-3:2026 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Nuclear power plants - Instrumentation and control important to safety - Electrical equipment condition monitoring methods - Part 3: Elongation at break (IEC/IEEE 62582-3:2024)". This standard covers: This part of IEC/IEEE 62582 contains methods for condition monitoring of organic and polymeric materials in instrumentation and control systems using tensile elongation techniques in the detail necessary to produce accurate and reproducible measurements. This document includes the requirements for selection of samples, the measurement system and conditions, and the reporting of the measurement results. The different parts of IEC/IEEE 62582 are measurement standards, primarily for use in the management of ageing in initial qualification and after installation. IEC/IEEE 62582-1 includes requirements for the application of the other parts of IEC/IEEE 62582 and some elements which are common to all methods. Information on the role of condition monitoring in qualification of equipment important to safety is found in IEC/IEEE 60780-323. This document is applicable to non-energised equipment.

This part of IEC/IEEE 62582 contains methods for condition monitoring of organic and polymeric materials in instrumentation and control systems using tensile elongation techniques in the detail necessary to produce accurate and reproducible measurements. This document includes the requirements for selection of samples, the measurement system and conditions, and the reporting of the measurement results. The different parts of IEC/IEEE 62582 are measurement standards, primarily for use in the management of ageing in initial qualification and after installation. IEC/IEEE 62582-1 includes requirements for the application of the other parts of IEC/IEEE 62582 and some elements which are common to all methods. Information on the role of condition monitoring in qualification of equipment important to safety is found in IEC/IEEE 60780-323. This document is applicable to non-energised equipment.

SIST EN IEC/IEEE 62582-3:2026 is classified under the following ICS (International Classification for Standards) categories: 27.120.20 - Nuclear power plants. Safety. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN IEC/IEEE 62582-3:2026 has the following relationships with other standards: It is inter standard links to SIST EN IEC/IEEE 62582-1:2026. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN IEC/IEEE 62582-3:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 elongation
  • 3.2 elongation at break
  • 3.3 nominal elongation at break
  • 3.4 gauge length
  • 3.5 test speed
  • 4 General description
  • 5 Applicability and reproducibility
  • 6 Measurement procedure
  • 6.1 Stabilisation of the polymeric materials
  • 6.2 Sampling
  • 6.3 Specimen preparation
  • 6.4 Instrumentation
  • 6.5 Tensile elongation measurement method
  • 6.6 Measurement report
  • Annex A
  • Annex B
  • Annex C
  • Annex D
  • Annex E
  • Bibliography

INTRODUCTION a) Technical background, main issues and organisation of the standard This part of this IEC/IEEE standard specifically focuses on elongation at break methods for condition monitoring for the management of ageing of electrical equipment installed in nuclear power plants. The method is primarily suited to samples taken from equipment that are based on polymeric materials.

This part of IEC/IEEE 62582 is the third part of the IEC/IEEE 62582 series. It contains detailed descriptions of condition monitoring based on elongation at break measurements. The IEC/IEEE 62582 series is issued with a joint logo which makes it applicable to management of ageing of electrical equipment qualified to IEEE as well as IEC Standards. IEC/IEEE 60780-323 defined term condition-based qualification which is an adjunct to type testing. The qualified condition is established by condition indicator(s) prior to the start of accident conditions for which the equipment was demonstrated to meet the design requirements for the specified service conditions. IEC/IEEE 60780-323 defined condition indicator. Significant research has been performed on condition monitoring techniques and the use of these techniques in equipment qualification as noted in NUREG/CR-6704, vol.2 (BNL-NUREG-52610), JNES-SS-0903, 2009 and IAEA-TECDOC-1825:2017. It is intended that this IEC/IEEE standard be used by test laboratories, operators of nuclear power plants, systems evaluators and licensors.

b) Situation of the current standard in the structure of the IEC SC 45A standard series Part 3 of IEC/IEEE 62582 is the third level IEC SC 45A document tackling the specific issue of application and performance of elongation at break measurements in management of ageing of electrical instrument and control equipment in nuclear power plants. Part 3 of IEC/IEEE 62582 is to be read in association with Part 1 of IEC/IEEE 62582, which provides requirements for application of methods for condition monitoring of electrical equipment important to safety of nuclear power plants.

For more details on the structure of the IEC SC 45A standard series, see item d) of this introduction.

c) Recommendations and limitations regarding the application of this standard It is important to note that this document establishes no additional functional requirements for safety systems.

d) Description of the structure of the IEC SC 45A standard series and relationships with other IEC documents and other bodies documents (IAEA, ISO) The IEC SC 45A standard series comprises a hierarchy of four levels. The top-level documents of the IEC SC 45A standard series are IEC 61513 and IEC 63046. IEC 61513 provides general requirements for instrumentation and control (I&C) systems and equipment that are used to perform functions important to safety in nuclear power plants (NPPs). IEC 63046 provides general requirements for electrical power systems of NPPs; it covers power supply systems including the supply systems of the I&C systems.

SIST EN IEC/IEEE 62582-3:2026

IEC 61513 and IEC 63046 are to be considered in conjunction and at the same level. IEC 61513 and IEC 63046 structure the IEC SC 45A standard series and shape a complete framework establishing general requirements for instrumentation, control and electrical power systems for nuclear power plants.

IEC 61513 and IEC 63046 refer directly to other IEC SC 45A standards for general requirements for specific topics, such as categorization of functions and classification of systems, qualification, separation, defence against common cause failure, control room design, electromagnetic compatibility, human factors engineering, cybersecurity, software and hardware aspects for programmable digital systems, coordination of safety and security requirements and management of ageing. The standards referenced directly at this second level should be considered together with IEC 61513 and IEC 63046 as a consistent document set. At a third level, IEC SC 45A standards not directly referenced by IEC 61513 or by IEC 63046 are standards related to specific requirements for specific equipment, technical methods, or activities. Usually these documents, which make reference to second-level documents for general requirements, can be used on their own.

A fourth level extending the IEC SC 45 standard series, corresponds to the Technical Reports which are not normative.

The IEC SC 45A standards series consistently implements and details the safety and security principles and basic aspects provided in the relevant IAEA safety standards and in the relevant documents of the IAEA nuclear security series (NSS). In particular this includes the IAEA requirements SSR-2/1 , establishing safety requirements related to the design of nuclear power plants (NPPs), the IAEA safety guide SSG-30 dealing with the safety classification of structures, systems and components in NPPs, the IAEA safety guide SSG-39 dealing with the design of instrumentation and control systems for NPPs, the IAEA safety guide SSG-34 dealing with the design of electrical power systems for NPPs, the IAEA safety guide SSG-51 dealing with human factors engineering in the design of NPPs and the implementing guide NSS42-G for computer security at nuclear facilities. The safety and security terminology and definitions used by the SC 45A standards are consistent with those used by the IAEA.

IEC 61513 and IEC 63046 have adopted a presentation format similar to the basic safety publication IEC 61508 with an overall life-cycle framework and a system life-cycle framework. Regarding nuclear safety, IEC 61513 and IEC 63046 provide the interpretation of the general requirements of IEC 61508-1, IEC 61508-2 and IEC 61508-4, for the nuclear application sector. In this framework, IEC 60880, IEC 62138 and IEC 62566 correspond to IEC 61508-3 for the nuclear application sector.

IEC 61513 and IEC 63046 refer to ISO 9001 as well as to IAEA GSR part 2 and IAEA GS-G-3.1 and IAEA GS-G-3.5 for topics related to quality assurance (QA). At level 2, regarding nuclear security, IEC 62645 is the entry document for the IEC/SC 45A security standards. It builds upon the valid high level principles and main concepts of the generic security standards, in particular ISO/IEC 27001 and ISO/IEC 27002; it adapts them and completes them to fit the nuclear context and coordinates with the IEC 62443 series. At level 2, IEC 60964 is the entry document for the IEC/SC 45A control rooms standards, IEC 63351 is the entry document for the human factors engineering standards and IEC 62342 is the entry document for the ageing management standards.

NOTE 1 It is assumed that for the design of I&C systems in NPPs that implement conventional safety functions (e.g. to address worker safety, asset protection, chemical hazards, process energy hazards) international or national standards would be applied.

NOTE 2 IEC TR 64000 provides a more comprehensive description of the overall structure of the IEC SC 45A standards series and of its relationship with other standards bodies and standards.

SIST EN IEC/IEEE 62582-3:2026

NUCLEAR POWER PLANTS – INSTRUMENTATION AND CONTROL IMPORTANT TO SAFETY – ELECTRICAL EQUIPMENT CONDITION MONITORING METHODS –

Part 3: Elongation at break

1 Scope

This part of IEC/IEEE 62582 contains methods for condition monitoring of organic and polymeric materials in instrumentation and control systems using tensile elongation techniques in the detail necessary to produce accurate and reproducible measurements. This document includes the requirements for selection of samples, the measurement system and conditions, and the reporting of the measurement results.

The different parts of IEC/IEEE 62582 are measurement standards, primarily for use in the management of ageing in initial qualification and after installation. IEC/IEEE 62582-1 includes requirements for the application of the other parts of IEC/IEEE 62582 and some elements which are common to all methods. Information on the role of condition monitoring in qualification of equipment important to safety is found in IEC/IEEE 60780-323.

This document is applicable to non-energised equipment.

2 Normative references

There are no normative references in this document.

3 Terms and definitions

For the purposes of this document, the following terms and definitions apply. ISO, IEC and IEEE maintain terminological databases for use in standardization at the following addresses:

  • IEC Electropedia: available at http://www.electropedia.org/
  • ISO Online browsing platform: available at http://www.iso.org/obp
  • IEEE Standards Dictionary Online: available at http://dictionary.ieee.org

3.1 elongation

E tensile strain, expressed as a percentage of the test length, produced in the piece by a tensile stress [SOURCE: ISO 37:2017, 3.2]

3.2 elongation at break

E b tensile strain in the test length at the breaking point [SOURCE: ISO 37:2017, 3.5]

SIST EN IEC/IEEE 62582-3:2026

3.3 nominal elongation at break

tensile strain, expressed as a percentage of the specimen length between the grips, produced in the specimen at the breaking point

3.4 gauge length

L

initial distance between the gauge marks on the central part of the test specimen. It is expressed in millimetres (mm) Note 1 to entry: See figures of the test specimens in the relevant part of ISO 527. [SOURCE: ISO 527-1:2019, 3.1]

3.5 test speed

rate of separation of the gripping jaws Note 1 to entry: It is expressed in millimetres per minute (mm/min). [SOURCE: ISO 527-1:2019, 3.5]

4 General description

This document provides requirements for the condition monitoring of organic and polymeric materials using tensile elongation techniques whereby a test specimen is extended along its longitudinal axis at constant speed until the specimen breaks. During the test, the load sustained on the specimen and its elongation are measured. For this standard, elongation at break is the measured parameter.

NOTE Elongation at break rather than tensile strength is used because for some polymeric materials, particularly thermoplastics, the strength can remain consistently equal to the yield strength after ageing even when the elongation has decreased to < 50 % absolute.

5 Applicability and reproducibility

The tensile elongation method described in this document is related to the long chain molecular structure of the polymer. As degradation proceeds, changes in the molecular structure occur as a result of cross-linking, chain scission, oxidation and other degradation mechanisms. These changes usually decrease the elongation at break.

The tensile elongation method described in this document is primarily suited to samples taken from equipment that are based on polymeric materials. The method is generally not suitable for fibre reinforced polymeric materials or resins such as epoxides. The tensile elongation method described in this document cannot be used in the field in the nuclear power plant but uses samples taken from the plant, which are then measured in the laboratory. Each tensile elongation measurement in the laboratory can take between 5 min and 10 min to complete.

NOTE Round robin tests using a method close to the current standard have shown a typical laboratory variation in results of measurements of elongation at break on identical specimens of 8 % to 10 %. The mechanical properties of some polymeric materials can be affected by the moisture content. Most organic and polymeric materials currently used in the containment are not significantly hygroscopic. However, if hygroscopic materials are used, the influence of the moisture content of the material on elongation at break should need to be considered, particularly after artificial thermal ageing as a consequence of long-term exposure to high temperature in an oven.

SIST EN IEC/IEEE 62582-3:2026

Degradation of some polymeric materials in radiation environments cannot be correlated to elongation at break.

6 Measurement procedure

6.1 Stabilisation of the polymeric materials

An appropriate time period shall be allowed for the polymeric materials in recently manufactured equipment to stabilise before any condition monitoring or accelerated ageing programmes are carried out. The time period over which the polymeric materials stabilise is normally dependent on the processing additives and polymer composition. If manufacturers’ stabilisation time data are not available, a period of 6 months should be allowed before commencing ageing to allow initial values from unaged samples to become stable.

6.2 Sampling

6.2.1 General

Measurements of tensile elongation provide information on the status of the equipment only at the specific location which has been sampled. Knowledge of the environmental conditions in representative areas during plant operation is a prerequisite for selecting sample locations for condition monitoring. It is important that these locations represent as wide a range of ageing conditions as possible with special consideration given to locations where ageing conditions could be severe, e.g. hotspots. The location of the sampling and available information about the environmental time history at the sample location selected shall be documented. Sampling procedures shall comply with local instructions, taking into account safety of personnel and equipment. Handling of equipment during removal of samples from the plant should be minimised, e.g. cables should not be bent more than is necessary to remove the sample.

Measurements of elongation at break are formulation dependent and can be sensitive to manufacturing variations, such as porosity. Any changes in formulation shall be evaluated.

6.2.2 Sample requirements

When preparing samples from whole cables that have been aged in the laboratory or in a deposit, samples shall be taken from sections of the cable at least 100 mm from the ends, unless such ends have been sealed during ageing.

In order to obtain reasonable confidence, a minimum of 5 test specimens is required for elongation measurements to be made on one specific sample. However, it is recognised that in some cases, e.g. in samples taken from hot-spots, there can be insufficient material available for this minimum to be satisfied.

...