SIST EN IEC 62705:2026
(Main)Nuclear facilities - Instrumentation and control important to safety - Radiation monitoring systems (RMS): Characteristics and lifecycle (IEC 62705:2022)
- Abstract
IEC 62705:2022 gives requirements for the lifecycle management of radiation monitoring systems (RMS) and gives guidance on the application of existing IEC standards covering the design and qualification of systems and equipment. The purpose of this document is to lay down requirements for the lifecycle management of RMSs and give application guidance. This document is intended to be consistent with the latest versions of International Standards dealing with radiation monitors, sampling of radioactive materials, instruments calibration, hardware and software design, classification, and qualification. This document is applicable to RMSs installed in nuclear facilities intended for use during normal operation, anticipated operational occurrences (AOO), design basis accidents (DBA) and design extension conditions (DEC), including severe accidents (SA). This second edition cancels and replaces the first edition published in 2014. This edition includes the following significant technical changes with respect to the previous edition:
- modification of the title.
- to be consistent with the categorization of the accident condition.
- to update the references to new standards published since the first edition.
- to update the terms and definitions.
- Status
- Published
- Public Enquiry End Date
- 31-Dec-2025
- Publication Date
- 18-Jun-2026
- Technical Committee
- I09 - Imaginarni 09
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 09-Jun-2026
- Due Date
- 14-Aug-2026
- Completion Date
- 19-Jun-2026
SIST EN IEC 62705:2026 is the Slovenian adoption of EN IEC 62705:2026, based on IEC 62705:2022 for nuclear facilities. It specifies lifecycle management requirements for radiation monitoring systems (RMS) important to safety and gives guidance on using existing IEC standards for their design and qualification. The standard is aimed at operators of nuclear facilities, systems evaluators and licensors working with RMS for normal operation, AOO, DBA, DEC and SA conditions.
What does SIST EN IEC 62705:2026 specify?
SIST EN IEC 62705:2026 specifies how to manage the lifecycle of RMS in nuclear facilities and how to apply the relevant IEC and ISO standards to those systems. It is written as a lifecycle and application guide, not as a standalone design code for every monitor type.
The scope covers RMS installed in nuclear facilities, including nuclear power plants and similar sites, and it applies to use during normal operation, anticipated operational occurrences (AOO), design basis accidents (DBA), and design extension conditions (DEC), including severe accidents (SA). It excludes laboratory analysis and associated sample extraction that are part of a complete effluent monitoring programme, and it excludes investigation for fuel removal.
The document is organized into clauses 1 to 11, followed by two informative annexes.
| Annex | What it covers |
|---|---|
| Annex A | Example of safety classification for RMS important to safety |
| Annex B | Relation between IEC 61513 system lifecycle phases and IEC 62705 requirements |
What are the key requirements of SIST EN IEC 62705:2026?
The main requirement of SIST EN IEC 62705:2026 is that RMS shall be handled through the full lifecycle - categorization, design, integration, installation, modification, qualification and calibration - using the applicable companion standards for the specific monitoring task and accident condition. In practice, the document helps the user choose the right monitor type and the right evidence for safety, performance and maintenance.
Categorization and classification
Clause 5 requires RMS functions important to safety to be categorized as A, B or C during the system requirement specification phase. RMS systems are then classified as class 1, 2 or 3 during the system specification phase.
This matters because the assigned category determines which software, hardware and HDL-programmed device requirements apply. Clause 5 links category A functions to IEC 60880, IEC 62566 and IEC 60987, and links category B or C functions to IEC 62138, IEC 62566-2 and IEC 60987.
Design by monitor type
Clause 6 separates RMS by the thing being monitored: radioactive noble gas, radioactive aerosol, radioactive iodine, liquid, tritium, on-line or in-line monitoring, area monitoring, centralized systems and leak detection. Each type is tied to a specific design and testing route.
For example, noble gas, aerosol and iodine off-line monitoring use the IEC 60761 series for normal operation, while DBA use brings in IEC 60951-1 and IEC 60951-2. Liquid off-line monitoring uses IEC 60861, tritium off-line monitoring uses IEC 60761-1 and IEC 60761-5 or IEC 62303, and on-line or in-line monitoring uses IEC 60768 for normal operation and IEC 60951-1 and IEC 60951-4 for DBA. This tells the reader which standard family matches the monitor they are buying, designing or assessing.
Area monitoring has a different path: IEC 61031 with IEC 60532 for normal operation, and IEC 60951-1 plus IEC 60951-3 for DBA and DEC, including SA. For centralized systems, Clause 6 points to IEC 61504 together with the IEC 61559 series, and to IEC 60960 when the centralized system is part of the safety parameter display system.
Integration, installation and modification
Clause 7 requires the integrated RMS to be shown to meet the functional, performance and interface specifications after equipment is assembled and interconnected. The validation has to cover not only I&C interfaces, but also interfaces to piping and mechanical components.
Clause 8 requires installation in the specified location and confirmation that environmental, seismic and electromagnetic conditions stay within the qualification envelope. Clause 9 then requires modifications to follow defined procedures, to be re-tested, and to avoid routine hardware or software changes outside maintenance procedures. If hardware is replaced, it has to be justified against the original specification.
Qualification and calibration
Clause 10 requires the qualification envelope of RMS equipment to match the installed environment. Environmental qualification for category A or B equipment follows IEC/IEEE 60780-323, seismic qualification follows IEC/IEEE 60980-344, and electromagnetic interference is evaluated in accordance with IEC 62003 unless the purchaser and manufacturer agree otherwise.
Clause 11 requires periodic calibration and functional checks so the RMS keeps its specified accuracy and performance. Radiation calibration uses the equipment standards named in Clause 6, together with ISO 4037-1 and ISO 4037-3 where appropriate, and the calibration should be traceable to the NSLR in the country of installation. If calibration is done in another country, traceability can be accepted when both countries have MRA accreditation under ISO/IEC 17025.
What terms does SIST EN IEC 62705:2026 define?
- RMS - Radiation Monitoring System, a system for measuring radiation levels and providing warning information.
- AOO - anticipated operational occurrence, a deviation from normal operation expected at least once in the plant lifetime without significant damage or progression to accident conditions.
- DBA - design basis accident, a postulated accident that the facility is designed to handle within established design criteria and acceptable release limits.
- DEC - design extension conditions, accident conditions beyond DBA that are still considered in the design process using best estimate methods.
- SA - severe accident, an accident more severe than a DBA with significant core degradation.
- HPD - HDL-Programmed Device, an integrated circuit configured with Hardware Description Languages and related tools for nuclear power plant I&C systems.
Who uses SIST EN IEC 62705:2026?
SIST EN IEC 62705:2026 is intended for operators of nuclear facilities, systems evaluators and licensors. In practice, it is used by teams that specify, design, integrate, validate, install, modify, qualify and calibrate RMS.
It is relevant to nuclear facilities such as nuclear power plants, and the introduction also cites nuclear fuel storage and processing sites. The standard helps these users decide which RMS type fits the plant condition, which companion standards apply, and what evidence is needed for safety-related review.
What changed in SIST EN IEC 62705:2026 from the previous edition?
This second edition cancels and replaces the first edition published in 2014. The stated changes are:
- modification of the title
- alignment with the categorization of accident conditions
- updated references to standards published since the first edition
- updated terms and definitions
Which standards are used with SIST EN IEC 62705:2026?
SIST EN IEC 62705:2026 is built around IEC 61513 and the related SC 45A framework for nuclear I&C systems. The most important companion standards are:
- IEC 61226 - categorization of functions and classification of systems
- IEC 60880, IEC 62138, IEC 60987, IEC 62566, IEC 62566-2 - software, hardware and HDL-programmed device requirements
- IEC 60761 series, IEC 62302, IEC 62303, IEC 60861, IEC 60768, IEC 61031 - monitor-specific requirements for gaseous, liquid, tritium, process stream and area monitoring
- IEC 60951 series and IEC 63147 - accident, post-accident and accident-monitoring guidance
- IEC 61504 and IEC 61559 series - centralized radiation monitoring systems
- IEC/IEEE 60780-323, IEC/IEEE 60980-344 and IEC 62003 - environmental, seismic and EMC qualification
- ISO 2889, ISO 4037-1, ISO 4037-3 and ISO/IEC 17025 - sampling, calibration radiation reference and laboratory competence
The introduction also names IEC 62645 for cybersecurity and IEC TR 63123 for the application of IEC 63147 in the IEC context.
What does the SIST EN IEC 62705:2026 document contain?
The document contains the lifecycle requirements for RMS, plus the supporting classification, design, integration, installation, modification, qualification and calibration clauses. It also includes an overview table of radiation monitoring standards in the introduction, which shows how the different IEC and ISO documents fit together across normal operation, AOO, DBA and DEC use.
Annex A gives an example safety classification table for RMS in PWR and BWR plants. Annex B maps IEC 61513 lifecycle phases to the corresponding RMS requirements in this standard, which helps users see where the RMS rules sit inside the wider nuclear I&C lifecycle.
Relations
- Effective Date
- 09-Feb-2026
- Effective Date
- 09-Feb-2026
- Effective Date
- 09-Feb-2026
- Refers
SIST EN 13087-10:2001 - Protective helmets - Test methods - Part 10: Resistance to radiant heat - Effective Date
- 09-Feb-2026
- Effective Date
- 09-Feb-2026
- Effective Date
- 09-Feb-2026
- Effective Date
- 09-Feb-2026
- Effective Date
- 09-Feb-2026
- Effective Date
- 09-Feb-2026
- Effective Date
- 09-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
Get Certified
Connect with accredited certification bodies for this standard

DNV
DNV is an independent assurance and risk management provider.

Lloyd's Register
Lloyd's Register is a global professional services organisation specialising in engineering and technology.

DNV Energy Systems
Energy and renewable energy certification.
Sponsored listings
Frequently Asked Questions
SIST EN IEC 62705:2026 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Nuclear facilities - Instrumentation and control important to safety - Radiation monitoring systems (RMS): Characteristics and lifecycle (IEC 62705:2022)". This standard covers: IEC 62705:2022 gives requirements for the lifecycle management of radiation monitoring systems (RMS) and gives guidance on the application of existing IEC standards covering the design and qualification of systems and equipment. The purpose of this document is to lay down requirements for the lifecycle management of RMSs and give application guidance. This document is intended to be consistent with the latest versions of International Standards dealing with radiation monitors, sampling of radioactive materials, instruments calibration, hardware and software design, classification, and qualification. This document is applicable to RMSs installed in nuclear facilities intended for use during normal operation, anticipated operational occurrences (AOO), design basis accidents (DBA) and design extension conditions (DEC), including severe accidents (SA). This second edition cancels and replaces the first edition published in 2014. This edition includes the following significant technical changes with respect to the previous edition: - modification of the title. - to be consistent with the categorization of the accident condition. - to update the references to new standards published since the first edition. - to update the terms and definitions.
IEC 62705:2022 gives requirements for the lifecycle management of radiation monitoring systems (RMS) and gives guidance on the application of existing IEC standards covering the design and qualification of systems and equipment. The purpose of this document is to lay down requirements for the lifecycle management of RMSs and give application guidance. This document is intended to be consistent with the latest versions of International Standards dealing with radiation monitors, sampling of radioactive materials, instruments calibration, hardware and software design, classification, and qualification. This document is applicable to RMSs installed in nuclear facilities intended for use during normal operation, anticipated operational occurrences (AOO), design basis accidents (DBA) and design extension conditions (DEC), including severe accidents (SA). This second edition cancels and replaces the first edition published in 2014. This edition includes the following significant technical changes with respect to the previous edition: - modification of the title. - to be consistent with the categorization of the accident condition. - to update the references to new standards published since the first edition. - to update the terms and definitions.
SIST EN IEC 62705:2026 is classified under the following ICS (International Classification for Standards) categories: 27.120.20 - Nuclear power plants. Safety. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN IEC 62705:2026 has the following relationships with other standards: It is inter standard links to SIST EN ISO/IEC 17025:2017, SIST EN ISO 105-X06:1999, SIST EN ISO 2871-2:1997, SIST EN 13087-10:2001, SIST EN ISO 4037-3:2021, SIST EN 13087-8:2001, SIST EN ISO 14660-1:2002, SIST EN 12139:1999, SIST EN ISO 8624:2002, SIST EN ISO 4037-1:2021, SIST EN 60761-3:2005, SIST EN 62566:2014, SIST EN IEC 61031:2022, SIST EN 60761-4:2005, SIST EN IEC 62138:2019. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN IEC 62705:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 accident conditions
- 3.2 alarm assembly
- 3.3 anticipated operational occurrence
- 3.4 calibration
- 3.5 category of an I&C function
- 3.6 centralized system
- 3.7 class of an I&C system
- 3.8 decision threshold
- 3.9 design basis accident
- 3.10 design extension conditions
- 3.11 detection limit
- 3.12 detector assembly
- 3.13 hardware description language
- 3.14 HDL-Programmed Device
- 3.15 in-line monitoring
- 3.16 monitoring assembly
- 3.17 network equipment
- 3.18 off-line monitoring
- 3.19 on-line monitoring
- 3.20 processing assembly
- 3.21 radiation monitor
- 3.22 sampling assembly
- 3.23 severe accident
- 3.24 volumetric activity
- 4 Symbols and abbreviated terms
- 5 RMS categorization and classification
- 5.1 Function categorization for RMS
- 5.2 System classification for RMS
- 5.3 Criteria for identifying the plant-specific variables
- 6 RMS detailed design and implementation
- 6.1 General
- 6.2 Radioactive noble gas off-line monitoring
- 6.3 Radioactive aerosol off-line monitoring
- 6.4 Radioactive iodine off-line monitoring
- 6.5 Liquid off-line monitoring
- 6.6 Tritium off-line monitoring
- 6.7 On-line or in-line monitoring
- 6.8 Area monitoring
- 6.9 Centralized system
- 6.10 Leak detection
- 7 RMS integration and validation
- 7.1 RMS integration
- 7.2 RMS validation
- 8 RMS installation
- 9 RMS design modification
- 10 RMS qualification
- 10.1 General
- 10.2 Environmental qualification
- 10.3 Seismic qualification
- 10.4 Electromagnetic interference
- 11 Calibration
- 11.1 General
- 11.2 Periodical calibration and functional check
- 11.3 Radiation calibration
- 11.4 Calibration for other quantity
- 11.5 Traceability
- Annex A
- Annex B
- 6.5 System qualification 10 RMS qualification
- 8 Overall operation and maintenance 11.2 Periodical calibration and functional check
- Bibliography
INTRODUCTION a) Technical background, main issues and organisation of the Standard This IEC standard sets out the requirements for the lifecycle management of radiation monitoring systems (RMS) installed in the nuclear facilities (e.g. nuclear power plants, nuclear fuel storage and processing sites).
This document is applicable to the equipment of RMS and intended for use during normal operations, anticipated operational occurrence (AOO), design basis accidents (DBA) and design extension conditions (DEC) including severe accidents (SA). The document is intended for use by operators of nuclear facilities (utilities), systems evaluators and by licensors.
b) Situation of the current Standard in the structure of the IEC SC 45A standard series IEC 62705 is the third level in the hierarchy of SC 45A standards. This document provides guidance on the application of existing IEC/ISO standards covering design and qualification of system and equipment for RMS. This document is an application supplement of IEC 61513 as shown in Annex B, and it is not intended that this document limits the application of other IEC 61513 requirements to RMS lifecycle.
For general requirements and guidance, the following standards provide requirements and guidance for RMS. IEC 61513 is the first level standard of SC 45A standards, and provides general requirements for I&C systems and equipment that are used to perform functions important to safety in nuclear facilities. IEC 61226 provides the criteria for classification of instrumentation and control functions. Most modern RMSs contain computer-based equipment. Hence RMS should often be treated as computer-based system. So the following standards required for computer-based system are generally applicable to RMS. IEC 60880 provides the software requirements for category A functions and IEC 62138 provides the software requirements for Category B or C functions. IEC 60987 provides hardware design requirements for computer-based systems. IEC 62566 provides the requirements for HDL- Programmed Device (HPD) for systems performing category A functions. IEC 62645 provides security requirements for computer based I&C systems. For qualification testing, the following SC 45A standards are applicable. IEC/IEEE 60780-323 provides guidance for the environmental qualification and IEC/IEEE 60980-344 provides guidance for seismic qualification for equipment performing category A or B functions. IEC 62003 provides the requirements for electromagnetic compatibility testing. In addition, IEC 61250 specifies the leak detection requirements by using RMS.
For radiation monitoring specific requirements, the following standards provide requirements and guidance for RMS. The IEC 60951 series provides guidance on the design and testing of radiation monitoring equipment used for anticipated operational occurrences (AOO), design basis accidents (DBA) and design extension conditions (DEC) including severe accident (SA). The IEC 60761 series provide requirements for equipment for continuous off-line monitoring of radioactivity in gaseous effluent in normal conditions. Some of the SC 45B standards (e.g. Gas offline: IEC 62302, Tritium: IEC 62303) are now replacing the IEC 60761 series. IEC 60861 provides requirements for equipment continuous off-line monitoring of radioactivity in liquid effluent in normal conditions. IEC 60768 provides requirements for equipment for continuous in-line and on-line monitoring of radioactivity in process stream in normal and incident conditions. IEC 61031 provides requirements for equipment for area radiation monitor in normal conditions in conjunction with IEC 60532. IEC 61504 provides requirements for centralized system for plant-wide radiation monitoring in conjunction with the IEC 61559 series which specifies the requirements for centralized system. If the centralized system is a part of the safety parameter display system, IEC 60960 provides the functional design criteria. ISO 2889 gives guidance on gas and particulate sampling. The ISO 4037 series provides calibration methodology for radiation monitors. The relationship between these various standards is given in Table 1. IEC 63147/IEEE Std 497™ provides general guidance for accident monitoring instrumentation. IEEE Std 497™ was directly adopted as a joint logo standard and a technical report, IEC TR 63123, was prepared to discuss the application of the joint standard within the IEC context.
SIST EN IEC 62705:2026
The structure of this standard is adapted from the structure of IEC 63147/IEEE Std 497™, and the technical requirements of this standard are consistent with the requirements given in IEC 63147/IEEE Std 497™ together with the application guidance given in IEC TR 63123. For more details on the structure of the IEC SC 45A standard series, see item d) of this introduction.
Table 1 – Overview of the standards covering the domain of radiation monitoring Developer ISO IEC SC45A SC45B Sampling Calibration Normal Normal Scope (Normal (Normal operation, DBA DEC operation operation) operation) AOO Radioactive noble IEC 62302, ISO 4037-1, IEC 60951-1, gas off-line ISO 2889 N/A N/A IEC 60761-1, ISO 4037-3 IEC 60951-2 monitoring IEC 60761-3 Radioactive ISO 4037-1, IEC 60951-1, IEC 60761-1, aerosol off-line ISO 2889 N/A N/A ISO 4037-3 IEC 60951-2 IEC 60761-2 monitoring Radioactive iodine ISO 4037-1, IEC 60951-1, IEC 60761-1, ISO 2889 N/A N/A off-line monitoring ISO 4037-3 IEC 60951-2 IEC 60761-4 Liquid off-line N/A N/A N/A N/A N/A IEC 60861 monitoring IEC 62303, Tritium off-line N/A N/A N/A N/A N/A IEC 60761-1, monitoring IEC 60761-5 On-line or in-line ISO 4037-1, IEC 60951-1, N/A IEC 60768 N/A N/A monitoring ISO 4037-3 IEC 60951-4 ISO 4037-1, Area monitoring N/A IEC 61031 IEC 60951-1, IEC 60951-3 IEC 60532 ISO 4037-3 Centralized N/A N/A IEC 61504, IEC 60960 N/A IEC 61559-1 system IEC 61513, IEC 60880, IEC 60987, IEC 61226, Classification/basi N/A N/A IEC 62138, IEC 62566, N/A N/A c requirements IEC 62566-2, IEC 62645, IEC 61250 IEC/IEEE 60780-323, Qualification N/A N/A IEC/IEEE 60980-344, N/A IEC 62706 IEC 62003
c) Recommendations and limitations regarding the application of this Standard It is important to note that this document establishes no additional functional requirements for systems important to safety. Where requirements are given in this standard, they refer generally to the need to apply other IEC and ISO Standards and specific functional and technical requirements contained in these standards.
To ensure that the document will continue to be relevant in future years, the emphasis has been placed on issues of principle, rather than specific technologies. d) Description of the structure of the IEC SC 45A standard series and relationships with other IEC documents and other bodies documents (IAEA, ISO) The IEC SC 45A standard series comprises a hierarchy of four levels. The top-level documents of the IEC SC 45A standard series are IEC 61513 and IEC 63046. IEC 61513 provides general requirements for instrumentation and control (I&C) systems and equipment that are used to perform functions important to safety in nuclear power plants (NPPs). IEC 63046 provides general requirements for electrical power systems of NPPs; it covers power supply systems including the supply systems of the I&C systems.
SIST EN IEC 62705:2026
IEC 61513 and IEC 63046 are to be considered in conjunction and at the same level. IEC 61513 and IEC 63046 structure the IEC SC 45A standard series and shape a complete framework establishing general requirements for instrumentation, control and electrical power systems for nuclear power plants.
IEC 61513 and IEC 63046 refer directly to other IEC SC 45A standards for general requirements for specific topics, such as categorization of functions and classification of systems, qualification, separation, defence against common cause failure, control room design, electromagnetic compatibility, human factors engineering, cybersecurity, software and hardware aspects for programmable digital systems, coordination of safety and security requirements and management of ageing. The standards referenced directly at this second level should be considered together with IEC 61513 and IEC 63046 as a consistent document set.
At a third level, IEC SC 45A standards not directly referenced by IEC 61513 or by IEC 63046 are standards related to specific requirements for specific equipment, technical methods, or activities. Usually these documents, which make reference to second-level documents for general requirements, can be used on their own.
A fourth level extending the IEC SC 45 standard series, corresponds to the Technical Reports which are not normative.
The IEC SC 45A standards series consistently implements and details the safety and security principles and basic aspects provided in the relevant IAEA safety standards and in the relevant documents of the IAEA nuclear security series (NSS). In particular this includes the IAEA requirements SSR-2/1 , establishing safety requirements related to the design of nuclear power plants (NPPs), the IAEA safety guide SSG-30 dealing with the safety classification of structures, systems and components in NPPs, the IAEA safety guide SSG- 39 dealing with the design of instrumentation and control systems for NPPs, the IAEA safety guide SSG-34 dealing with the design of electrical power systems for NPPs, the IAEA safety guide SSG-51 dealing with human factors engineering in the design of NPPs and the implementing guide NSS17 for computer security at nuclear facilities. The safety and security terminology and definitions used by the SC 45A standards are consistent with those used by the IAEA.
IEC 61513 and IEC 63046 have adopted a presentation format similar to the basic safety publication IEC 61508 with an overall life-cycle framework and a system life-cycle framework. Regarding nuclear safety, IEC 61513 and IEC 63046 provide the interpretation of the general requirements of IEC 61508-1, IEC 61508-2 and IEC 61508-4, for the nuclear application sector. In this framework, IEC 60880, IEC 62138 and IEC 62566 correspond to IEC 61508-3 for the nuclear application sector.
IEC 61513 and IEC 63046 refer to ISO 9001 as well as to IAEA GSR part 2 and IAEA GS- G-3.1 and IAEA GS-G-3.5 for topics related to quality assurance (QA). At level 2, regarding nuclear security, IEC 62645 is the entry document for the IEC/SC 45A security standards. It builds upon the valid high level principles and main concepts of the generic security standards, in particular ISO/IEC 27001 and ISO/IEC 27002; it adapts them and completes them to fit the nuclear context and coordinates with the IEC 62443 series. At level 2, IEC 60964 is the entry document for the IEC/SC 45A control rooms standards, IEC 63351 is the entry document for the human factors engineering standards and IEC 62342 is the entry document for the ageing management standards. NOTE 1 It is assumed that for the design of I&C systems in NPPs that implement conventional safety functions (e.g. to address worker safety, asset protection, chemical hazards, process energy hazards) international or national standards would be applied.
NOTE 2 IEC TR 64000 provides a more comprehensive description of the overall structure of the IEC SC 45A standards series and of its relationship with other standards bodies and standards.
SIST EN IEC 62705:2026
NUCLEAR FACILITIES – INSTRUMENTATION AND CONTROL IMPORTANT TO SAFETY – RADIATION MONITORING SYSTEMS (RMS):
CHARACTERISTICS AND LIFECYCLE
1 Scope
This document gives requirements for the lifecycle management of radiation monitoring systems (RMS) and gives guidance on the application of existing IEC standards covering the design and qualification of systems and equipment.
The purpose of this document is to lay down requirements for the lifecycle management of RMSs and give application guidance. This document is intended to be consistent with the latest versions of International Standards dealing with radiation monitors, sampling of radioactive materials, instruments calibration, hardware and software design, classification, and qualification. Unless otherwise specified in this document, top level IEC SC 45A standard, IEC 61513, and the second level IEC SC 45A standards apply to RMSs. This document is applicable to RMSs installed in nuclear facilities intended for use during normal operation, anticipated operational occurrences (AOO), design basis accidents (DBA) and design extension conditions (DEC), including severe accidents (SA). The technical guidance contained in this document applies to nuclear facilities, although the specific functions of individual facilities are considered during the design and operational lifecycle of RMSs. Laboratory analysis and associated sample extraction, which are essential to a complete programme of effluent monitoring, and investigation for fuel removal are not in the scope of this document.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
IEC 60532, Radiation protection instrumentation – Installed dose rate meters, warning assemblies and monitors – X and gamma radiation of energy between 50 keV and 7 MeV IEC 60761-1, Equipment for continuous monitoring of radioactivity in gaseous effluents – Part 1:
General requirements IEC 60761-2, Equipment for continuous monitoring of radioactivity in gaseous effluents – Part 2:
Specific requirements for radioactive aerosol monitors including transuranic aerosols IEC 60761-3, Equipment for continuous monitoring of radioactivity in gaseous effluents – Part 3:
Specific requirements for radioactive noble gas monitors IEC 60761-4, Equipment for continuous monitoring of radioactivity in gaseous effluents – Part 4:
Specific requirements for radioactive iodine monitors IEC 60761-5, Equipment for continuous monitoring of radioactivity in gaseous effluents – Part 5:
Specific requirements for tritium monitors
SIST EN IEC 62705:2026
IEC 60768, Nuclear power plants – Instrumentation important to safety – Equipment for continuous in-line or on-line monitoring of radioactivity in process streams for normal and incident conditions IEC/IEEE 60780-323:2016, Nuclear facilities – Electrical equipment important to safety system - Qualification IEC 60861, Equipment for monitoring of radionuclides in liquid effluents and surface waters IEC 60880, Nuclear power plants – Instrumentation and control systems important to safety – Software aspects for computer-based systems performing category A functions IEC 60951-1:2022, Nuclear power plants – Instrumentation important to safety – Radiation monitoring for accident and post-accident conditions – Part 1: General requirements IEC 60951-2, Nuclear power plants – Instrumentation important to safety – Radiation monitoring for accident and post-accident conditions – Part 2: Equipment for continuous off-line monitoring of radioactivity in gaseous effluents and ventilation air IEC 60951-3, Nuclear power plants – Instrumentation important to safety – Radiation monitoring for accident and post-accident conditions – Part 3: Equipment for continuous high range area gamma monitoring IEC 60951-4, Nuclear power plants – Instrumentation important to safety – Radiation monitoring for accident and post-accident conditions – Part 4: Equipment for continuous in-line or on-line monitoring of radioactivity in process streams IEC 60960, Functional design criteria for a safety parameter display system for nuclear power stations IEC/IEEE 60980-344, Nuclear facilities – Equipment important to safety – Seismic qualification IEC 60987, Nuclear power plants – Instrumentation and control important to safety – Hardware requirements IEC 61031, Nuclear facilities – Instrumentation and control systems – Design, location and application criteria for installed area gamma radiation dose rate monitoring equipment for use during normal operation and anticipated operational occurrences IEC 61226:2020, Nuclear power plants – Instrumentation, control and electrical power systems important to safety – Categorization of functions and classification of systems IEC 61250, Nuclear reactors – Instrumentation and control systems important for safety – Detection of leakage in coolant systems IEC 61504, Nuclear facilities – Instrumentation and control systems important to safety – Centralized systems for continuous monitoring of radiation and/or levels of radioactivity IEC 61513:2011, Nuclear power plants – Instrumentation and control important to safety – General requirements for systems IEC 61559 (all parts), Radiation protection instrumentation in nuclear facilities – Centralized systems for continuous monitoring of radiation and/or levels of radioactivity IEC 62003, Nuclear power plants – Instrumentation, control and electrical power systems – Requirements for electromagnetic compatibility testing
SIST EN IEC 62705:2026
...