Ambient air quality - Diffusive samplers for the determination of concentrations of gases and vapours - Requirements and test methods - Part 1: General requirements

This part of the European Standard specifies general performance requirements for diffusive samplers used for the determination of the concentration of gases and vapours in ambient air. Such requirements apply to all diffusive samplers, irrespective of the physical nature of the rate controlling process and irrespective of the nature of the sorption process and the analytical determination. This standard applies to all stages of the measuring procedure, including deployment, transportation and storage of the sample where appropriate.

Außenluftqualität - Passivsammler zur Bestimmung der Konzentrationen von Gasen und Dämpfen - Anforderungen und Prüfverfahren - Teil 1: Allgemeine Anforderungen

Diese Europäische Norm legt allgemeine Leistungsanforderungen für Passivsammler, die zur Bestimmung der Konzentration von Gasen und Dämpfen in Außenluft eingesetzt werden, fest.
Solche Anforderungen gelten für alle Passivsammler, unabhängig von der physikalischen Natur des die Sammelrate bestimmenden Vorgangs und unabhängig von der Art des Sorptionsvorgangs und der analytischen Bestimmung.
Diese Norm gilt für alle Schritte des Messverfahrens, einschließlich Aufstellung, Transport und Lagerung der Probe, soweit zutreffend.
Diese Norm gilt sowohl für Messverfahren mit getrennten Probenahme- und Analyseschritten als auch für direktanzeigende Vorrichtungen.

Qualité de l'air ambiaent - Echantillonneurs par diffusion pour la détermination des concentrations des gaz et des vapeurs - Exigences et méthodes d'essai - Partie 1: Exigences générales

La présente partie de l'EN 13528 spécifie les exigences générales de performance relatives aux échantillonneurs par diffusion utilisés pour déterminer la concentration des gaz et des vapeurs dans l'air ambiant.
Ces exigences s'appliquent a tous les échantillonneurs par diffusion, quelles que soient la nature physique du processus de contrôle du débit et la nature du procédé d'adsorption et de la détermination analytique.
La présente norme s'applique a toutes les étapes de la procédure de mesurage, y compris le déploiement, le transport et le stockage de l'échantillon, le cas échéant.
Elle s'applique aux procédures de mesurage qui comportent des phases distinctes d'échantillonnage et d'analyse, ainsi qu'aux instruments a lecture directe.

Kakovost zunanjega zraka - Difuzijski vzorčevalniki za določevanje koncentracije plinov in par - Zahteve in preskusne metode - 1. del: Splošne zahteve

General Information

Status
Published
Publication Date
28-Feb-2003
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Mar-2003
Due Date
01-Mar-2003
Completion Date
01-Mar-2003

Buy Standard

Standard
EN 13528-1:2003
English language
11 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.WHYHAußenluftqualität - Passivsammler zur Bestimmung der Konzentrationen von Gasen und Dämpfen - Anforderungen und Prüfverfahren - Teil 1: Allgemeine AnforderungenQualité de l'air ambiaent - Echantillonneurs par diffusion pour la détermination des concentrations des gaz et des vapeurs - Exigences et méthodes d'essai - Partie 1: Exigences généralesAmbient air quality - Diffusive samplers for the determination of concentrations of gases and vapours - Requirements and test methods - Part 1: General requirements13.040.20Kakovost okoljskega zrakaAmbient atmospheresICS:Ta slovenski standard je istoveten z:EN 13528-1:2002SIST EN 13528-1:2003en01-marec-2003SIST EN 13528-1:2003SLOVENSKI
STANDARD



SIST EN 13528-1:2003



EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 13528-1September 2002ICS 13.040.20English versionAmbient air quality - Diffusive samplers for the determination ofconcentrations of gases and vapours - Requirements and testmethods - Part 1: General requirementsQualité de l'air - Echantillonneurs par diffusion pour ladétermination des concentrations des gaz et des vapeurs -Prescriptions et méthodes d'essai - Partie 1: PrescriptionsgénéralesAußenluftqualität - Passivsammler zur Bestimmung derKonzentrationen von Gasen und Dämpfen - Anforderungenund Prüfverfahren - Teil 1: Allgemeine AnforderungenThis European Standard was approved by CEN on 21 July 2002.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece,Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2002 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 13528-1:2002 ESIST EN 13528-1:2003



EN 13528-1:2002 (E)2ContentspageForeword.3Introduction.41Scope.52Normative references.53Terms and definitions.54Assessment regimes.75Performance requirements.75.1Unambiguity.75.2Selectivity.85.3Data Quality Objectives.85.4Composite procedures.85.5Environmental conditions.85.6Description of measuring procedure.85.7Dimension of result.85.8Quality systems.86Test methods.87Test report.9Annex A
(informative)
Assessment of ambient air quality.10Bibliography.11SIST EN 13528-1:2003



EN 13528-1:2002 (E)3ForewordThis document (EN 13528-1:2002) has been prepared by Technical Committee CEN/TC 264 “Air Quality”, thesecretariat of which is held by DIN.This European Standard shall be given the status of a national standard, either by publication of an identical text orby endorsement, at the latest by March 2003, and conflicting national standards shall be withdrawn at the latest byMarch 2003.This European Standard is a multi-part standard having the following parts:¾ Part 1 (Ambient Air Quality) General requirements;¾ Part 2 (Ambient Air Quality) Specific requirements and test methods;¾ Part 3 (Ambient Air Quality) Guide to selection, use and maintenance.Annex A is informative.According to the CEN/CENELEC Internal Regulations, the national standards organizations of the followingcountries are bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark, Finland,France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain,Sweden, Switzerland and the United Kingdom.SIST EN 13528-1:2003



EN 13528-1:2002 (E)4IntroductionThis European Standard specifies requirements and test methods for the determination of performancecharacteristics of diffusive samplers used for the determination of concentrations of gases and vapours in ambientatmospheres.With regard to air quality, the objectives fixed in the 5th Action Programme of the European Union are for theeffective protection of all people against recognised risks from air pollution and the establishment of permittedconcentration levels of air pollutants, which should take into account the protection of the environment. Theseobjectives include monitoring of concentrations with regard to standards.Successive programmes of action of the European Union on the protection of the environment have stressed theneed to find a balance between the use of different tools: product standards, emission limits and environmentalobjectives/standards.The implementation of existing Directives has highlighted the existence of various problems, which are beingaddressed in the Council Directive on Ambient Air Quality Assessment and Management [1]. These include:¾ the different monitoring strategies in comparable situations between and within Member States;¾ the harmonisation of measuring methods;¾ the quality of the measurements which depends on the calibration and quality assurance procedures.Diffusive samplers used to measure air quality have to fulfil some general requirements, which are given in this partof EN 13528. These requirements include unambiguity, selectivity and Data Quality Objectives, includinguncertainty.Such general requirements can also be appropriate for other measurement procedures used in the assessment ofambient air quality.In addition, diffusive samplers used to measure air quality shall also fulfil some specific requirements in addition tothose specified in this part of EN 13528. These specific requirements are given in EN 13528-2. EN 13528-3 givesguidance on the selection, use and maintenance of diffusive samplers used to measure ambient air quality.It is the user's primary responsibility to choose appropriate procedures or devices that meet the requirements in thisEuropean Standard. One way of doing this is to obtain information or confirmation from the manufacturer. Typetesting, or more generally, the assessment of performance criteria of procedures or devices, can be undertaken bythe manufacturer, user, test house or research and development laboratory, as is most appropriate.Although this part of EN 13528 specifically addresses ambient air, diffusive sampling is also relevant to theassessment of air quality in indoor air. Both pumped and diffusive sampling procedures are considered appropriatefor such measurements, depending on circumstances (particularly any requirement for time resolution) [2].prEN 14412 gives guidance on the selection, use and maintenance of diffusive samplers used to measure indoorair quality.This part of EN 13528 is similar in content to EN 482:1994 and EN 13528-2 is similar in content to EN838:1995.The series of standards on the use of diffusive samplers for ambient air has been created in addition tothose for workplace air because the underlying European Directives are different and the consequent definitionsand practical applications of the estimation of the uncertainty of measurements are different.SIST EN 13528-1:2003



EN 13528-1:2002 (E)51 ScopeThis European Standard specifies general performance requirements for diffusive samplers used for thedetermination of the concentration of gases and vapours in ambient air.Such requirements apply to all diffusive samplers, irrespective of the physical nature of the rate controlling processand irrespective of the nature of the sorption process and the analytical determination.This standard applies to all stages of the measuring procedure, including deployment, transportation and storage ofthe sample where appropriate.This standard applies to measuring procedures with separate sampling and analysis stages, and also to direct-reading devices.2 Normative referencesThis European Standard incorporates by dated or undated reference, provisions from other publications. Thesenormative references are cited at the appropriate places in the text, and the publications are listed hereafter. Fordated references, subsequent amendments to or revisions of any of these publications apply to this EuropeanStandard only when incorporated in it by amendment or revision. For undated references the latest edition of thepublication referred to applies (including amendments).ENV 13005, Guide to the expression of uncertainty in measurement.EN ISO/IEC 17025, General requirements for the competence of testing and calibration laboratories (ISO/IEC17025:1999).ISO 5725:1994, Accuracy (trueness and precision) of measurement methods and results (all parts).3 Terms and definitionsFor the purpose of this European Standard the following terms and definitions apply.3.1ambient airoutdoor air in the troposphere, excluding indoor air and workplaces3.2averaging timeperiod of time for which the measuring procedure yields a single value [EN 482:1994]3.3biasdifference between the expectation of the test results and an accepted reference value [ISO 3534-1:1993]3.4combined standard uncertaintystandard uncertainty of the result of a measurement when that result is obtained from the values of a number ofother quantities, equal to the positive square root of a sum of terms, the terms being the variances or covariancesof these other quantities weighted according to how the measurement result varies with changes in these quantities[ENV 13005]3.5desorption efficiencyratio of the mass of analyte desorbed from a sampling device to that applied [EN 838:1995]SIST EN 13528-1:2003



EN 13528-1:2002 (E)63.6diffusive samplerdevice which is capable of taking samples of gases or vapours from the atmosphere at a rate controlled by aphysical process such as gaseous diffusion through a static air layer or a porous material and/or permeationthrough a membrane, but which does not involve the active movement of air through the deviceNOTE 1Active normally refers to the pumped movement of air.NOTE 2This definition differs from that in EN 838:1995 by the addition of the words 'or a porous material'.3.7expanded uncertaintyquantity defining an interval about the result of a measurement that may be expected to encompass a large fractionof the distribution of values that could reasonably be attributed to the measurandNOTE 1The fraction may
...