Water meters - Part 4: Additional functionalities

This European Standard specifies definitions, requirements and testing of additional functionalities for water meters, without metrological impact, in combination with Additional Functionality Devices (AFD) and in response to EU/EFTA Mandate M/441 EN. These AFDs are to be considered as “ancillary devices" as defined in EN 14154-1.
This European Standard does not cover the changing of metrological software within the meter or the upload/download of metrological software.
NOTE    A manufacturer can claim compliance only for additional functionalities described in this standard. It is not mandatory that an AFD complies with all additional functionalities described herein.

Wasserzähler - Teil 4: Zusätzliche Funktionalitäten

Dieses Dokument legt Begriffe, Anforderungen und Prüfverfahren für zusätzliche Funktionalitäten für Wasserzähler ohne metrologische Auswirkungen in Kombination mit Zusatzfunktionsgeräten (ZFG) entsprechend EU/EFTA-Mandat M/441 EN fest. Diese ZFGs gelten als "Zusatzgeräte" gemäß der Definition in EN ISO 4064-1:2017 und EN ISO 4064-4:2014.
Dieses Dokument behandelt nicht die Änderung metrologischer Software innerhalb des Zählers oder deren Hoch-/Herunterladen.
ANMERKUNG   Ein Hersteller kann nur für in dieser Europäischen Norm beschriebene Zusatzfunktionen Konformität beanspruchen. Ein Zusatzfunktionsgerät (ZFG) muss nicht notwendigerweise alle in diesem Dokument definierten Funktionen beinhalten.

Compteurs d’eau - Partie 4 : Fonctionnalités additionnelles

Le présent document spécifie les définitions, exigences et essais des fonctionnalités additionnelles des compteurs d’eau, sans impact métrologique, en combinaison avec les dispositifs à fonctionnalités additionnelles (AFD) et en réponse au mandat UE/EFTA M/441 EN. Ces AFD sont considérés comme des « dispositifs auxiliaires » conformément à la définition de l’EN ISO 4064-1:2017 et de l’EN ISO 4064-4:2014.
Le présent document ne traite pas de la modification du logiciel à caractère métrologique dans le compteur ou du téléchargement d’un logiciel à caractère métrologique.
NOTE   Un fabricant peut déclarer la conformité uniquement pour les fonctionnalités additionnelles décrites dans le présent document. Il n’est pas obligatoire qu’un AFD soit conforme à toutes les fonctionnalités additionnelles décrites dans le présentee document.

Vodomeri - 4. del: Dodatne funkcije

Ta evropski standard določa definicije, zahteve in preskušanje dodatnih funkcij za vodomere, brez meroslovnega vpliva, v kombinaciji z napravami z dodatnimi funkcijami (AFD) in kot odziv na mandat EU/EFTA M/441 EN. Te naprave z dodatnimi funkcijami se upoštevajo kot »pomožne naprave«, kot je opredeljeno v standardu EN 14154-1.
Ta evropski standard ne zajema sprememb meroslovne programske opreme merilnika ali prenosa/nalaganja programske opreme merilnika.
OPOMBA:    Proizvajalec lahko navede skladnost le za dodatne funkcionalnosti, opisane v tem standardu. Ni obvezno, da je naprava z dodatnimi funkcijami skladna z vsemi dodatnimi funkcionalnostmi, opisanimi v tem dokumentu.

General Information

Status
Published
Public Enquiry End Date
28-Feb-2022
Publication Date
04-Apr-2023
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
27-Mar-2023
Due Date
01-Jun-2023
Completion Date
05-Apr-2023

Relations

Buy Standard

Standard
EN 14154-4:2023
English language
24 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Draft
prEN 14154-4:2022
English language
22 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 14154-4:2023
01-maj-2023
Vodomeri - 4. del: Dodatne funkcije
Water meters - Part 4: Additional functionalities
Wasserzähler - Teil 4: Zusätzliche Funktionalitäten
Compteurs d’eau - Partie 4 : Fonctionnalités additionnelles
Ta slovenski standard je istoveten z: EN 14154-4:2023
ICS:
91.140.60 Sistemi za oskrbo z vodo Water supply systems
SIST EN 14154-4:2023 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST EN 14154-4:2023

---------------------- Page: 2 ----------------------
SIST EN 14154-4:2023


EN 14154-4
EUROPEAN STANDARD

NORME EUROPÉENNE

March 2023
EUROPÄISCHE NORM
ICS 91.140.60 Supersedes EN 14154-4:2014
English Version

Water meters - Part 4: Additional functionalities
Compteurs d'eau - Partie 4 : Fonctionnalités Wasserzähler - Teil 4: Zusätzliche Funktionalitäten
additionnelles
This European Standard was approved by CEN on 23 January 2023.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.

This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.





EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2023 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 14154-4:2023 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------
SIST EN 14154-4:2023
EN 14154-4:2023 (E)
Contents Page
European foreword . 4
Introduction . 5
1 Scope . 6
2 Normative references . 6
3 Terms and definitions . 6
4 General requirements . 8
4.1 Types of additional functionality devices and requirements . 8
4.2 Connection requirements . 8
4.3 Environmental conditions . 8
4.4 Security . 9
4.4.1 General . 9
4.4.2 Software, data and hardware security . 9
4.4.3 Firmware upgrade of AFD . 9
4.4.4 Software identification . 9
4.5 Power supply . 9
4.6 Data storage . 10
4.7 Clock requirements . 10
4.7.1 General . 10
4.7.2 Clock synchronisation . 10
4.7.3 Clock setting . 10
4.8 Marking . 10
4.8.1 Requirements . 10
4.8.2 Test . 11
4.9 Documentation . 11
4.9.1 General . 11
4.9.2 Declaration of conformity . 11
4.9.3 Instruction manual . 11
4.10 Display . 12
4.10.1 General . 12
4.10.2 Requirements . 12
4.10.3 Test . 12
4.11 Metrological influence . 12
4.11.1 Requirement . 12
4.11.2 Test . 12
4.12 Input to AFD / Output from AFD . 13
4.12.1 General . 13
4.12.2 Requirement . 13
4.12.3 Test . 13
5 Additional functionalities . 13
5.1 General . 13
5.2 Use cases . 13
5.2.1 Scheduled read . 13
5.2.2 Pre-programmed reading date . 14
5.2.3 On demand read . 14
5.2.4 History of consumption . 14
2

---------------------- Page: 4 ----------------------
SIST EN 14154-4:2023
EN 14154-4:2023 (E)
5.2.5 Background leak . 14
5.2.6 Burst . 15
5.2.7 Reverse flow . 15
5.2.8 Zero flow . 16
5.2.9 Tamper of AFD . 16
5.2.10 Tamper of meter . 16
5.2.11 Battery low . 16
5.2.12 Presence of air . 17
5.2.13 Access profiles . 17
6 Environmental considerations . 17
Annex A (normative) Declaration of conformity to EN 14154-4 . 18
Annex B (informative) Smart Metering, overview, core functionalities and descriptions . 19
B.1 General . 19
B.2 M2M Gateway . 19
B.3 Clusters . 20
B.4 Primary Use Cases . 20
B.5 Secondary Use Cases . 20
B.6 Primary Actors . 20
B.7 Actors . 20
B.8 Use Cases . 20
Annex C (informative) References to EN ISO 4064-1:2017, EN ISO 4064-2:2017,
EN ISO 4064-3:2014, EN ISO 4064-4:2014, EN ISO 4064-5:2017 . 21
Bibliography . 24
3

---------------------- Page: 5 ----------------------
SIST EN 14154-4:2023
EN 14154-4:2023 (E)
European foreword
This document (EN 14154-4:2023) has been prepared by Technical Committee CEN/TC 92 “Water
meters”, the secretariat of which is held by SNV.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by September 2023, and conflicting national standards shall
be withdrawn at the latest by September 2023.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN 14154-4:2014.
This document has been prepared under a Standardization Request given to CEN by the European
Commission and the European Free Trade Association.
Any feedback and questions on this document should be directed to the users’ national standards body.
A complete listing of these bodies can be found on the CEN website.
According to the CEN-CENELEC Internal Regulations, the national standards organisations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia,
Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland,
Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Republic of North
Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and the United
Kingdom.
4

---------------------- Page: 6 ----------------------
SIST EN 14154-4:2023
EN 14154-4:2023 (E)
Introduction
This document has been developed as part of the work being undertaken by the European Standards
Organizations (CEN/CENELEC/ETSI) under the Commission Mandate M/441. This document utilizes the
six functionalities agreed by the Smart Meters Coordination Group (SM-CG) (see Annex B) as the basis for
its additional functionalities. It is not required for the Additional Functionality Device (AFD) to
incorporate all functions described in this document.
Communications for water meters are outside the scope of this document and are covered by the
appropriate parts of the EN 13757 series, which provides a number of protocols and transport layers for
meter communications for Gas, Water and Thermal Energy meters. The additional functionality for water
meters can be provided by a number of methods; these are illustrated below, see Figure 1 (4.1), and
described in detail within this document. The AFD can be integrated in the meter, attached to the meter
or remote from the meter.
5

---------------------- Page: 7 ----------------------
SIST EN 14154-4:2023
EN 14154-4:2023 (E)
1 Scope
This document specifies definitions, requirements and testing of additional functionalities for water
meters, without metrological impact, in combination with Additional Functionality Devices (AFD) and in
response to EU/EFTA Mandate M/441 EN. These AFDs are considered as “ancillary devices” as defined
in EN ISO 4064-1:2017 and EN ISO 4064-4:2014.
This document does not cover the changing of metrological software within the meter or the
upload/download of metrological software.
NOTE A manufacturer can claim compliance only for additional functionalities described in this document. It
is not mandatory that an AFD complies with all additional functionalities described herein.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN ISO 4064-1:2017, Water meters for cold potable water and hot water - Part 1: Metrological and
technical requirements (ISO 4064-1:2014)
EN ISO 4064-2:2017, Water meters for cold potable water and hot water - Part 2: Test methods (ISO
4064-2:2014)
EN ISO 4064-4:2014, Water meters for cold potable water and hot water - Part 4: Non-metrological
requirements not covered in ISO 4064-1 (ISO 4064-4:2014)
EN ISO 4064-5:2017, Water meters for cold potable water and hot water - Part 5: Installation requirements
(ISO 4064-5:2014)
EN 60529:1991, Degrees of protection provided by enclosures (IP Code)
3 Terms and definitions
For the purposes of this document, the terms, definitions and symbols given in EN ISO 4064-1:2017,
EN ISO 4064-2:2017, EN ISO 4064-4:2014 and EN ISO 4064-5:2017 and the following apply.
NOTE The following terms and definitions are only related to additional functionalities.
3.1
functionality
process which constantly or at specified intervals, automatically or on demand, performs specific
activities such as sampling data, reading a data set, verifying or changing a status, or activating a switch
3.2
additional functionality
functionality that a smart meter provides, over and above the metrological functionality covered by the
Measuring Instruments Directive
3.3
additional functionality device
device providing any additional functionality
6

---------------------- Page: 8 ----------------------
SIST EN 14154-4:2023
EN 14154-4:2023 (E)
3.4
additional functionality device type 1
AFD1
additional functionality device integrated into the meter
3.5
additional functionality device type 2
AFD2
additional functionality device directly attached to the meter
3.6
additional functionality device type 3
AFD3
additional functionality device remotely connected to the meter
3.7
automatic meter reading
technology for obtaining metering data from an on-site meter by communication from a remote access
point
3.8
universal time coordinated
UTC
world time, without daylight savings
3.9
reading
primary indication of the total volume passed through the meter
3.10
metrological software
software identified during the type testing examination, which is part of the meter and is critical to its
metrological characteristics
3.11
register
indication of the specific section in the memory of the control and metering unit that records data as
determined by the programme in the unit
3.12
event
condition requiring action or to log an action
3.13
event log
temporary or mid-term memorized listing of events, containing their occurrence, actions taken and their
reset
3.14
interface
point or means of interaction between two systems
7

---------------------- Page: 9 ----------------------
SIST EN 14154-4:2023
EN 14154-4:2023 (E)
4 General requirements
4.1 Types of additional functionality devices and requirements
The additional functionality shall be provided by one of the following devices:
— AFD1; where all functions are within the same metrological enclosure as the meter;
— AFD2; where the AFD is attached directly to the meter. The manufacturer shall declare the
appropriate device compatibility;
— AFD3; where the AFD is located remotely and connected to the meter via a pulse interface or
communication interface. The manufacturer shall declare the appropriate device compatibility.

Figure 1 — Additional functionality devices
4.2 Connection requirements
The AFD2 and AFD3 shall be connected to the meter and tested as a combined unit in all the tests given
in 4.11.2 to ensure the connection of the AFD to the meter has no metrological influence.
The connection of the AFD to the meter or any labelling on the meter or the AFD shall not obscure or
damage any metrological seal of the meter or the regulatory marking.
When the AFD is connected, the consumer shall be able to read the primary indication on the meter to
units of at least cubic meters without the use of tools.
4.3 Environmental conditions
The AFD shall work with the meter at all operating conditions of the meter as required by the appropriate
standards.
Any AFD should be suitable to meet one of the environmental classes from EN ISO 4064-1:2017,
A.2 and A.3 and the related tests. An AFD3 may have a different environmental class to that of the meter.
8

---------------------- Page: 10 ----------------------
SIST EN 14154-4:2023
EN 14154-4:2023 (E)
4.4 Security
4.4.1 General
The AFD shall be constructed in such a way that any unauthorized intervention shall either cause
permanently visible damage to the AFD or its protective seals, or creates a report in the event log. Any
physical seals shall be visibly fixed, and easily accessible.
4.4.2 Software, data and hardware security
4.4.2.1 Requirement
When tested in accordance with 4.4.2.2 the requirements below shall be met.
All available connections, ports and interfaces of the AFD which can be used for unauthorized adjustment
of the AFDs characteristics and additional functionality shall be effectively secured by protective seals.
No access shall be allowed to software and firmware by unauthorised persons. Software and data shall
be protected against accidental or intentional changes by the breaking of a physical seal or by using an
electronic seal.
For electronic seals the following requirements shall be met:
a) access shall only be obtained by using a password or a code;
b) unauthorized intervention shall be registered in the event log and the type of intervention identified,
and where available date and time to be included.
In the case of intended consumer access to the AFD, it shall be ensured that the access by the consumer
cannot inadvertently drain the battery capacity, where applicable.
4.4.2.2 Test
Compliance with the above requirements shall be checked by visual inspection and evaluation of the
manufacturer’s technical documentation.
4.4.3 Firmware upgrade of AFD
This part of the document covers non-metrological upgrades only, providing there is clear separation
between the metrological and non-metrological functions.
Following any upgrade, the information/functionality of the AFD shall be as declared by the
manufacturer. Any data still present shall be the same as prior to the upgrade.
NOTE Further guidance is available in WELMEC Guide 7.2.
4.4.4 Software identification
The software (including version) shall have an unambiguous identifier that is retrievable.
4.5 Power supply
The power supply of the AFD shall comply with EN ISO 4064-1:2017, EN ISO 4064-4:2014 and shall be
tested accordingly.
For battery powered AFD, the manufacturer shall specify the minimum operational lifetime of the battery
depending on the stated functionality and operation (e.g. transmission intervals of radio communication
device).
9

---------------------- Page: 11 ----------------------
SIST EN 14154-4:2023
EN 14154-4:2023 (E)
4.6 Data storage
The AFD shall be capable of storing data such as interval and event data. The manufacturer shall declare
which data are stored and how to access the stored data.
The stored data shall be retained and retrievable in non-volatile memory in the event of power failure as
tested according to EN ISO 4064-2:2017 unless the AFD has a non-replacable battery.
4.7 Clock requirements
4.7.1 General
Stored data shall be time stamped. The time stamps shall be generated by a clock which gives:
— a relative time stamp; or
— a non-synchronized time stamp; or
— a synchronized time stamp.
It is recommended that the synchronized time stamp within the AFD uses UTC.
The accuracy of the time stamp shall be suitable for its intended use.
4.7.2 Clock synchronisation
If the manufacturer declares that the AFD has a clock that can be synchronised with the clock of the meter,
then it shall be possible to carry out this synchronization.
A record shall also be placed in the event log showing what action was taken.
4.7.3 Clock setting
If the manufacturer allows setting of the clock, access shall only be achieved by the use of an electronic
seal or the breaking of a physical seal.
A record shall also be placed in the event log showing what action was taken.
4.8 Marking
4.8.1 Requirements
When tested in accordance with 4.8.2 the AFD shall as a minimum be marked as follows:
a) the number and date of this document;
b) identification mark or name of the manufacturer;
c) serial number and year of manufacture;
d) mark with respective IP rating (according to EN 60529:1991);
e) ambient temperature range;
f) information about the type of battery (for security, transport and recycling purposes).
NOTE Additional marking can be required by legislation (e.g. CE marking, etc.).
10

---------------------- Page: 12 ----------------------
SIST EN 14154-4:2023
EN 14154-4:2023 (E)
With the exception of b) and c), if all applicable information cannot be shown on the AFD this shall be
provided on the packaging or with the documentation provided. Additionally, the necessary information
could be printed in a machine readable way (QR code, bar-code, etc.) on an accessable face of the AFD.
4.8.2 Test
This test is carried out by visual inspection. Machine-readable codes shall be tested with suitable machine
readers to demonstrate legibility.
4.9 Documentation
4.9.1 General
The following information shall be provided with each AFD or group of AFD’s used in the same location.
4.9.2 Declaration of conformity
For each AFD a Declaration of Conformity as per Annex A shall be available in written form or electronic
format and shall identify the name and address of the manufacturer and the date of issue.
4.9.3 Instruction manual
The operating instructions manual shall cover installation, operation and maintenance and shall be
available in written form or electronic format and shall identify the name and address of the
manufacturer and the date of issue. Each AFD or meter-AFD combination or packaging units of those shall
be delivered with installation, operation and maintenance appropriate instruction manuals, including:
— safe use and hazards arising from misuse and particular features of the design when appropriate;
— rated operating conditions;
— mechanical and electromagnetic environment classes;
— safe disposal and/or recycling guidance;
— conditions for compatibility with interfaces and type of communication protocol; and
— storage requirements.
The manuals may include the following optional information:
— possible installation positions;
— safety requirements concerning commissioning and de-commissioning procedures;
— statement if a maintenance is possible and a relevant instruction;
— way of controlling the proper installation and operation;
— provisions, if any, for transport and handling;
— how to trace the right spare parts; and
— a description of each of the additional functionalities.
11

---------------------- Page: 13 ----------------------
SIST EN 14154-4:2023
EN 14154-4:2023 (E)
4.10 Display
4.10.1 General
This subclause specifies general requirements for an electronic display that may be incorporated in the
AFD.
4.10.2 Requirements
Displayed data that is consumer relevant shall be easily legible and available without the use of tools.
When tested in accordance with 4.10.3, information shall be indicated either on:
a) the display fitted to the meter;
b) the display of an AFD;
c) a combination of the above.
The information and flags shall be displayed by means of user action or by means of automatic and
sequential scrolling for at least 10 s.
The identification and the unit of each information or parameter shall be clear and unambiguous.
The manufacturer shall declare what information can be displayed.
4.10.3 Test
A test shall be executed by visual inspection.
4.11 Metrological influence
4.11.1 Requirement
When tested in accordance with 4.11.2, the AFD shall have no influence on the metrological
characteristics of the meter.
If the AFD provides a facsimile/copy of the meter’s results, it shall be tested in accordance with 4.11.2 to
ensure these results are identical to those on the meter.
When tested in accordance with 4.11.2 the AFD shall operate with the interfaces specified by the
manufacturer and display the information as specified by
...

SLOVENSKI STANDARD
oSIST prEN 14154-4:2022
01-februar-2022
Vodomeri - 4. del: Dodatne funkcije
Water meters - Part 4: Additional functionalities
Wasserzähler - Teil 4: Zusätzliche Funktionalitäten
Compteurs d’eau - Partie 4 : Fonctionnalités additionnelles
Ta slovenski standard je istoveten z: prEN 14154-4
ICS:
91.140.60 Sistemi za oskrbo z vodo Water supply systems
oSIST prEN 14154-4:2022 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
oSIST prEN 14154-4:2022

---------------------- Page: 2 ----------------------
oSIST prEN 14154-4:2022


DRAFT
EUROPEAN STANDARD
prEN 14154-4
NORME EUROPÉENNE

EUROPÄISCHE NORM

December 2021
ICS 91.140.60 Will supersede EN 14154-4:2014
English Version

Water meters - Part 4: Additional functionalities
Compteurs d'eau - Partie 4 : Fonctionnalités Wasserzähler - Teil 4: Zusätzliche Funktionalitäten
additionnelles
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 92.

If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.


EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2021 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 14154-4:2021 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------
oSIST prEN 14154-4:2022
prEN 14154-4:2021 (E)
Contents           Page
European foreword . 3
Introduction . 4
1 Scope . 5
2 Normative references . 5
3 Terms and definitions . 5
4 General requirements . 7
4.1 Types of additional functionality devices and requirements . 7
4.2 Connection requirements . 7
4.3 Environmental conditions . 7
4.4 Security . 8
4.5 Power supply . 8
4.6 Data storage . 9
4.7 Clock requirements . 9
4.8 Marking . 9
4.9 Documentation . 10
4.10 Display . 11
4.11 Metrological influence . 11
4.12 Input to AFD / Output from AFD . 12
5 Additional functionalities . 12
5.1 General . 12
5.2 Use cases . 12
6 Environmental considerations . 16
Annex A (normative) Declaration of conformity to EN 14154-4 . 17
Annex B (informative) Smart Metering, overview, core functionalities and definitions . 18
B.1 General . 18
B.2 M2M Gateway . 18
B.3 Clusters . 19
B.4 Primary Use Cases . 19
B.5 Secondary Use Cases . 19
B.6 Primary Actors . 19
B.7 Actors . 19
B.8 Use Cases . 19
Annex C (informative) References to  EN ISO 4064-1:2017, EN ISO 4064-2:2017,
EN ISO 4064-3:2014, EN ISO 4064-4:2014, EN ISO 4064-5:2017 . 20
Bibliography . 22

2

---------------------- Page: 4 ----------------------
oSIST prEN 14154-4:2022
prEN 14154-4:2021 (E)
European foreword
This document (prEN 14154-4:2021) has been prepared by Technical Committee CEN/TC 92 “Water
meters”, the secretariat of which is held by SNV.
This document is currently submitted to the CEN Enquiry.
This document will supersede EN 14154-4:2014.
This document has been prepared under a Standardization Request given to CEN by the European
Commission and the European Free Trade Association.
3

---------------------- Page: 5 ----------------------
oSIST prEN 14154-4:2022
prEN 14154-4:2021 (E)
Introduction
This European Standard has been defined as part of the work being undertaken by the European
Standards Organizations (CEN/CENELEC/ETSI) under the Commission Mandate M/441. This document
utilizes the six functionalities agreed by the Smart Meters Coordination Group (SM-CG) (see Annex B) as
the basis for its additional functionalities. It is not required for the Additional Functionality Device (AFD)
to incorporate all functions defined in this document.
Communications for water meters are outside the scope of this document and are covered by the
appropriate parts of EN 13757-1, EN 13757-2, EN 13757-3, EN 13757-4, EN 13757-5 and EN 13757-6
which provide a number of protocols and transport layers for meter communications for Gas, Water and
Heat meters. The additional functionality for water meters can be provided by a number of methods;
these are illustrated below, see Figure 1 (4.1), and described in detail within this document. The AFD can
be integrated in the meter, attached to the meter or remote from the meter.
4

---------------------- Page: 6 ----------------------
oSIST prEN 14154-4:2022
prEN 14154-4:2021 (E)
1 Scope
This document specifies definitions, requirements and testing of additional functionalities for water
meters, without metrological impact, in combination with Additional Functionality Devices (AFD) and in
response to EU/EFTA Mandate M/441 EN. These AFDs are considered as “ancillary devices” as defined
in EN ISO 4064-1:2017 and EN ISO 4064-4:2014.
This document does not cover the changing of metrological software within the meter or the
upload/download of metrological software.
NOTE A manufacturer can claim compliance only for additional functionalities described in this document. It
is not mandatory that an AFD complies with all additional functionalities described herein.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN ISO 4064-1:2017, Water meters for cold potable water and hot water - Part 1: Metrological and
technical requirements (ISO 4064-1:2014)
EN ISO 4064-2:2017, Water meters for cold potable water and hot water - Part 2: Test methods (ISO 4064-
2:2014)
EN ISO 4064-4:2014, Water meters for cold potable water and hot water - Part 4: Non-metrological
requirements not covered in ISO 4064-1 (ISO 4064-4:2014)
EN ISO 4064-5:2017, Water meters for cold potable water and hot water - Part 5: Installation requirements
(ISO 4064-5:2014)
EN 60529:1991, Degrees of protection provided by enclosures (IP Code) (IEC 60529:1989)
3 Terms and definitions
For the purposes of this document, the terms, definitions and symbols given in EN ISO 4064-1:2017,
EN ISO 4064-2:2017, EN ISO 4064-4:2014 and EN ISO 4064-5:2017, and the following apply.
NOTE The following terms and definitions are only related to additional functionalities.
3.1
functionality
process which constantly or at defined intervals, automatically or on demand, performs specific activities
such as sampling data, reading a data set, verifying or changing a status, or activating a switch
3.2
additional functionality
functionality that a smart meter provides, over and above the metrological functionality covered by the
Measuring Instruments Directive
3.3
additional functionality device
device providing any additional functionality
5

---------------------- Page: 7 ----------------------
oSIST prEN 14154-4:2022
prEN 14154-4:2021 (E)
3.4
additional functionality device type 1
AFD1
additional functionality device integrated into the meter
3.5
additional functionality device type 2
AFD2
additional functionality device directly attached to the meter
3.6
additional functionality device type 3
AFD3
additional functionality device remotely connected to the meter
3.7
automatic meter reading
technology for obtaining metering data from an on-site meter by communication from a remote access
point
3.8
universal time coordinated
UTC
world time, without daylight savings
3.9
reading
primary indication of the total volume passed through the meter
3.10
metrological software
software identified during the type testing examination, which is part of the meter and is critical to its
metrological characteristics
3.11
register
Indication of the specific section in the memory of the control and metering unit that records data as
determined by the programme in the unit
3.12
event
condition requiring action or to log an action
3.13
event log
temporary or mid-term memorized listing of events, containing their occurrence, actions taken and their
reset
3.14
interface
point or means of interaction between two systems
6

---------------------- Page: 8 ----------------------
oSIST prEN 14154-4:2022
prEN 14154-4:2021 (E)
4 General requirements
4.1 Types of additional functionality devices and requirements
The additional functionality shall be provided by one of the following devices:
— AFD1; where all functions are within the same metrological enclosure as the meter;
— AFD2; where the AFD is attached directly to the meter. The manufacturer shall declare the
appropriate device compatibility;
— AFD3; where the AFD is located remotely and connected to the meter via a pulse interface or
communication interface. The manufacturer shall declare the appropriate device compatibility.

Figure 1 — Additional functionality devices
4.2 Connection requirements
The AFD2 and AFD3 shall be connected to the meter and tested as a combined unit in all the tests given
in 4.11.2 to ensure the connection of the AFD to the meter has no metrological influence.
The connection of the AFD to the meter or any labelling on the meter or the AFD shall not obscure or
damage any metrological seal of the meter.
When the AFD is connected, the consumer shall be able to read the primary indication on the meter to
units of at least cubic meters without the use of tools.
4.3 Environmental conditions
The AFD shall work with the meter at all operating conditions of the meter as required by the appropriate
standards.
Any AFD should be suitable to meet one of the environmental classes from EN ISO 4064-1:2017, A.2 and
A.3 and the related tests. An AFD3 may have a different environmental class to that of the meter.
7

---------------------- Page: 9 ----------------------
oSIST prEN 14154-4:2022
prEN 14154-4:2021 (E)
4.4 Security
4.4.1 General
The AFD shall be constructed in such a way that any unauthorized intervention shall either cause
permanently visible damage to the AFD or its protective seals, or creates a report in the event log. Any
physical seals shall be visibly fixed, and easily accessible.
4.4.2 Software, data and hardware security
4.4.2.1 Requirement
When tested in accordance with 4.4.2.2 the requirements below shall be met.
All available connections, ports and interfaces of the AFD which can be used for unauthorized adjustment
of the AFDs characteristics and additional functionality shall be effectively secured by protective seals.
No access shall be allowed to software and firmware by unauthorised persons. Software and data shall
be protected against accidental or intentional changes by the breaking of a physical seal or by using an
electronic seal.
For electronic seals the following requirements shall be met:
a) access shall only be obtained by using a password or a code;
b) unauthorized intervention shall be registered in the event log and the type of intervention identified,
and where available date and time to be included.
In the case of intended consumer access to the AFD, it shall be ensured that the access by the consumer
cannot inadvertently drain the battery capacity, where applicable.
4.4.2.2 Test
Compliance with the above requirements shall be checked by visual inspection and evaluation of the
manufacturer’s technical documentation.
4.4.3 Firmware upgrade of AFD
This part of the standard covers non-metrological upgrades only, providing there is clear separation
between the metrological and non-metrological functions.
Following any upgrade the information/functionality of the AFD shall be as declared by the manufacturer.
Any data still present shall be the same as prior to the upgrade.
NOTE Further guidance is available in WELMEC Guide 7.2
4.4.4 Software identification
The software (including version) shall have an unambiguous identifier that is retrievable.
4.5 Power supply
The power supply of the AFD shall comply with EN ISO 4064-1:2017, EN ISO 4064-4:2014 and shall be
tested accordingly.
For battery powered AFD, the manufacturer shall specify the minimum operational lifetime of the battery
depending on the stated functionality and operation. (E.G transmission intervals of radio communication
device)
8

---------------------- Page: 10 ----------------------
oSIST prEN 14154-4:2022
prEN 14154-4:2021 (E)
4.6 Data storage
The AFD shall be capable of storing data such as interval and event data. The manufacturer shall declare
which data are stored and how to access the stored data.
The stored data shall be retained and retrievable in non-volatile memory in the event of power failure as
tested according to EN ISO 4064-2:2017 unless the AFD has a non-replacable battery.
4.7 Clock requirements
4.7.1 General
Stored data shall be time stamped. The time stamps shall be generated by a clock which gives:
— a relative time stamp, or
— a non-synchronized time stamp, or
— a synchronized time stamp.
It is recommended that the synchronized time stamp within the AFD uses UTC.
The accuracy of the time stamp shall be suitable for its intended use.
4.7.2 Clock synchronisation
If the manufacturer declares that the AFD has a clock that can be synchronised with the clock of the meter,
then it shall be possible to carry out this synchronization.
A record shall also be placed in the event log showing what action was taken.
4.7.3 Clock setting
If the manufacturer allows setting of the clock, access shall only be achieved by the use of an electronic
seal or the breaking of a physical seal.
A record shall also be placed in the event log showing what action was taken.
4.8 Marking
4.8.1 Requirements
When tested in accordance with 4.8.2 the AFD shall as a minimum be marked as follows:
a) the number and date of this standard;
b) identification mark or name of the manufacturer;
c) serial number and year of manufacture;
d) mark with respective IP rating (EN 60529:1991);
e) ambient temperature range;
f) information about the type of battery (for security, transport and recycling purposes).
NOTE Additional marking might be required by legislation (e.g. CE marking, etc.).
9

---------------------- Page: 11 ----------------------
oSIST prEN 14154-4:2022
prEN 14154-4:2021 (E)
With the exception of b) and c), if all applicable information cannot be shown on the AFD this shall be
provided on the packaging or with the documentation provided. Additionally the necessary information
could be printed in a machine readable way (QR code, bar-code, etc.) on an accessable face of the AFD.
4.8.2 Test
This test is carried out by visual inspection. Machine-readable codes shall be tested with suitable machine
readers to demonstrate legibility.
4.9 Documentation
4.9.1 General
The following information shall be provided with each AFD or group of AFD’s used in the same location.
4.9.2 Declaration of conformity
For each AFD a Declaration of Conformity as per Annex A shall be available in written form or electronic
format and shall identify the name and address of the manufacturer and the date of issue.
4.9.3 Instruction manual
The operating instructions manual shall cover installation, operation and maintenance and shall be
available in written form or electronic format and shall identify the name and address of the
manufacturer and the date of issue. Each AFD or meter-AFD combination or packaging units of those shall
be delivered with installation, operation and maintenance appropriate instruction manuals, including:
— safe use and hazards arising from misuse and particular features of the design when appropriate;
— rated operating conditions;
— mechanical and electromagnetic environment classes;
— safe disposal and/or recycling guidance;
— conditions for compatibility with interfaces and type of communication protocol, and
— storage requirements.
The manuals may include the following optional information:
— possible installation positions;
— safety requirements concerning commissioning and de-commissioning procedures;
— statement if a maintenance is possible and a relevant instruction;
— way of controlling the proper installation and operation;
— provisions, if any, for transport and handling;
— how to trace the right spa
...

Questions, Comments and Discussion