SIST EN 300 019-1-4 V2.1.2:2006
(Main)Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 1-4: Classification of environmental conditions; Stationary use at non-weatherprotected locations
- Abstract
The purpose of the present document is to define a class of environmental conditions and their severities to which equipment may be exposed. Only severe conditions, which may be harmful to the equipment, are included. The severities specified are those which will have a low probability of being exceeded; generally less than 1 %. The present document applies to equipment mounted for stationary use including periods of erection work, down time, maintenance and repair at non-weatherprotected locations defined in clause 5.
- Status
- Published
- Publication Date
- 31-Jan-2006
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 01-Feb-2006
- Due Date
- 01-Feb-2006
- Completion Date
- 01-Feb-2006
SIST EN 300 019-1-4 V2.1.2:2006 is the Slovenian adoption of ETSI EN 300 019-1-4 V2.1.2, published by SIST for telecommunications equipment. It classifies the environmental conditions and severities for stationary use at non-weatherprotected locations. In practice, it is used to describe exposed outdoor conditions for equipment that is installed in place, including erection work, downtime, maintenance and repair.
What does SIST EN 300 019-1-4 V2.1.2:2006 specify?
SIST EN 300 019-1-4 V2.1.2:2006 specifies environmental classes for telecommunications equipment exposed to severe conditions at non-weatherprotected locations. The document keeps the focus on conditions that may harm equipment and on severities with a low probability of being exceeded, generally less than 1%.
The standard belongs to a multi-part ETSI series. Part 1 classifies environmental conditions, while Part 2 specifies the related environmental tests.
| Class | What it covers |
|---|---|
| 4.1 | General non-weatherprotected locations, covering most of Europe |
| 4.1E | Extended non-weatherprotected locations for Europe |
| 4.2L | Extremely cold non-weatherprotected locations world-wide |
| 4.2H | Extremely warm, dry non-weatherprotected locations world-wide |
The document is organized into Scope, References, Definitions, Environmental classes, and Environmental conditions.
What are the key requirements of SIST EN 300 019-1-4 V2.1.2:2006?
SIST EN 300 019-1-4 V2.1.2:2006 classifies the outdoor environment by climate, biology, chemicals, mechanically active substances, mechanical stress, and earthquakes. The point is to help users match an installation site or a product design to a defined class before testing or deployment.
Climate and exposure classes
Clause 4 defines the four environmental classes and links them to the expected climate range. Class 4.1 is the general case, 4.1E extends the European climatic range, and 4.2L and 4.2H cover extreme cold and extreme warm-dry conditions.
Clause 5.1 then groups the climatic parameters that matter in practice: temperature, humidity, rain, pressure, solar radiation, air movement, condensation, precipitation, water splash, and icing or frost. This is the core checklist for site classification and for deciding whether equipment needs extra protection.
Biological, chemical, and mechanically active substances
Clauses 5.2, 5.3, and 5.4 cover biological conditions, chemically active substances, and mechanically active substances. The standard treats mould, fungus, rodents, salt mist, corrosive gases, sand, and dust as environmental stresses that can affect reliability, enclosure integrity, or maintenance intervals.
Clause 5.3 also identifies special classes for chemical exposure, and clause 5.4 does the same for sand and dust. In practice, these special classes let a user call out a more demanding single parameter when one hazard is more important than the others.
Mechanical and earthquake conditions
Clause 5.5 covers stationary vibration and non-stationary vibration, including shock type II. This matters for equipment mounted near machines, vehicles, or other vibration sources, and it points users to EN 300 019-2-4 for test severities and methods.
Clause 5.6 covers earthquake conditions where they are likely to occur. It uses a response spectrum approach and explains how Zero Period Acceleration (ZPA) is derived for equipment on rigid foundations or structures, with a separate note for buildings, pylons, poles, and other mounting cases.
What terms does SIST EN 300 019-1-4 V2.1.2:2006 define?
- Absolute humidity - the mass of water vapour in a given volume of dry air.
- Relative humidity - the ratio between actual water vapour pressure and saturation vapour pressure at the same temperature.
- Stationary use - equipment firmly mounted or permanently placed at one site, with only short handling periods during erection, downtime, maintenance, and repair.
- Non-weatherprotected location - a location where equipment is not protected from direct weather influences.
- Response Spectrum (RS) - a graphical way to describe the maximum response of oscillators to seismic base motion.
- Zero Period Acceleration (ZPA) - the high-frequency acceleration limit used in the earthquake description.
- ETSI - the European Telecommunications Standards Institute, the publisher of the underlying European Standard.
Who uses SIST EN 300 019-1-4 V2.1.2:2006?
SIST EN 300 019-1-4 V2.1.2:2006 is used by people who specify, design, test, and accept telecommunications equipment for exposed stationary sites. Typical users include equipment designers, environmental test engineers, quality managers, compliance staff, and buyers who need to state the site class before ordering or qualifying hardware.
It is especially relevant for outdoor telecom installations where the environment includes weather, contamination, vibration, or seismic risk. The keyword set in the document - environment, testing, equipment practice - reflects that practical use.
What changed in SIST EN 300 019-1-4 V2.1.2:2006 from the previous edition?
SIST EN 300 019-1-4 V2.1.2:2006 is the V2.1.2 version of the standard. The document history lists earlier publication as ETS 300 019-1-4, Amendment 1 to the first edition, V2.1.1, and V2.1.2.
Which standards are used with SIST EN 300 019-1-4 V2.1.2:2006?
- IEC 60721-3-4 - gives the base classification framework that the environmental classes are related to.
- IEC 60721-2-4 - supports the treatment of solar radiation and temperature.
- IEC 60068-2-27 - provides the shock test guidance referenced for vibration and shock terminology.
- IEC 60721-2-6 - supports the earthquake environment description.
- IEC 60068-3-3 - provides seismic test methods used in the earthquake clause.
- ETSI EN 300 019-1-3 - is the related class for stationary use at weatherprotected locations.
- ETSI EN 300 019-2-4 - specifies the test severities and test methods for these non-weatherprotected classes.
- ETSI ETR 035 - gives guidance and terminology for environmental engineering.
What does the SIST EN 300 019-1-4 V2.1.2:2006 document contain?
The document contains class descriptions, climatic limits, and the environmental parameters needed to classify a site or a product use case. Its figures include climatograms for the class ranges and an earthquake response spectrum.
Tables 1 to 5 set out the environmental conditions for climate, biology, chemical exposure, mechanically active substances, and mechanical loading. Table 6 and Table 7 give the earthquake parameters and the response spectrum coordinates used in the seismic description.
For users, this means the standard is not a product test method by itself. It is the classification basis that supports design decisions, environmental specification, and the selection of the matching test standard.
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.
IMP NDT d.o.o.
Non-destructive testing services. Radiography, ultrasonic, magnetic particle, penetrant, visual inspection.
Inštitut za kovinske materiale in tehnologije
Institute of Metals and Technology. Materials testing, metallurgical analysis, NDT.
Sponsored listings
Frequently Asked Questions
SIST EN 300 019-1-4 V2.1.2:2006 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 1-4: Classification of environmental conditions; Stationary use at non-weatherprotected locations". This standard covers: The purpose of the present document is to define a class of environmental conditions and their severities to which equipment may be exposed. Only severe conditions, which may be harmful to the equipment, are included. The severities specified are those which will have a low probability of being exceeded; generally less than 1 %. The present document applies to equipment mounted for stationary use including periods of erection work, down time, maintenance and repair at non-weatherprotected locations defined in clause 5.
The purpose of the present document is to define a class of environmental conditions and their severities to which equipment may be exposed. Only severe conditions, which may be harmful to the equipment, are included. The severities specified are those which will have a low probability of being exceeded; generally less than 1 %. The present document applies to equipment mounted for stationary use including periods of erection work, down time, maintenance and repair at non-weatherprotected locations defined in clause 5.
SIST EN 300 019-1-4 V2.1.2:2006 is classified under the following ICS (International Classification for Standards) categories: 19.040 - Environmental testing; 33.050.01 - Telecommunication terminal equipment in general. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 300 019-1-4 V2.1.2:2006 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-februar-2006
2NROMVNLLQåHQLULQJ((±2NROMVNLSRJRMLLQSUHVNXVLYSOLYRYRNROMDQD
WHOHNRPXQLNDFLMVNRRSUHPR±GHO.ODVLILNDFLMDRNROMVNLKSRJRMHY±)LNVQD
XSRUDEDQDORNDFLMDKNLQLVR]DãþLWHQHSUHGYUHPHQVNLPLYSOLYL
Environmental Engineering (EE); Environmental conditions and environmental tests for
telecommunications equipment; Part 1-4: Classification of environmental conditions;
Stationary use at non-weatherprotected locations
Ta slovenski standard je istoveten z: EN 300 019-1-4 Version 2.1.2
ICS:
19.040 Preskušanje v zvezi z Environmental testing
okoljem
33.050.01 Telekomunikacijska Telecommunication terminal
terminalska oprema na equipment in general
splošno
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
European Standard (Telecommunications series)
Environmental Engineering (EE);
Environmental conditions and environmental tests
for telecommunications equipment;
Part 1-4: Classification of environmental conditions;
Stationary use at non-weatherprotected locations
2 ETSI EN 300 019-1-4 V2.1.2 (2003-04)
Reference
REN/EE-01027-1-4[2]
Keywords
environment, testing, equipment practice
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE
Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88
Important notice
Individual copies of the present document can be downloaded from:
http://www.etsi.org
The present document may be made available in more than one electronic version or in print. In any case of existing or
perceived difference in contents between such versions, the reference version is the Portable Document Format (PDF).
In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive
within ETSI Secretariat.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
http://portal.etsi.org/tb/status/status.asp
If you find errors in the present document, send your comment to:
editor@etsi.org
Copyright Notification
No part may be reproduced except as authorized by written permission.
The copyright and the foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 2003.
All rights reserved.
TM TM TM
DECT , PLUGTESTS and UMTS are Trade Marks of ETSI registered for the benefit of its Members.
TM
TIPHON and the TIPHON logo are Trade Marks currently being registered by ETSI for the benefit of its Members.
TM
3GPP is a Trade Mark of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners.
ETSI
3 ETSI EN 300 019-1-4 V2.1.2 (2003-04)
Contents
Intellectual Property Rights.4
Foreword.4
1 Scope.5
2 References.5
3 Definitions.6
4 Environmental classes.6
4.1 Class 4.1: Non-weatherprotected locations .7
4.2 Class 4.1E: Non-weatherprotected locations - extended .7
4.3 Class 4.2L: Non-weatherprotected locations - extremely cold.7
4.4 Class 4.2H: Non-weatherprotected locations - extremely warm dry.7
5 Environmental conditions.9
5.1 Climatic conditions.9
5.2 Biological conditions.9
5.3 Chemically active substances .10
5.4 Mechanically active substances.10
5.5 Mechanical conditions.11
5.6 Earthquake conditions.11
History .14
ETSI
4 ETSI EN 300 019-1-4 V2.1.2 (2003-04)
Intellectual Property Rights
IPRs essential or potentially essential to the present document may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web
server (http://webapp.etsi.org/IPR/home.asp).
All published ETSI deliverables shall include information which directs the reader to the above source of information.
Foreword
This European Standard (Telecommunications series) has been produced by ETSI Technical Committee Environmental
Engineering (EE).
The present document is part 1, sub part 4 of a multi-part deliverable covering the classification of environmental
conditions and environmental tests for telecommunications equipment, as identified below:
Part 1: "Classification of environmental conditions"; (see note 1)
Sub-part 0: "Introduction";
Sub-part 1: "Storage";
Sub-part 2: "Transportation";
Sub-part 3: "Stationary use at weatherprotected locations";
Sub-part 4: "Stationary use at non-weatherprotected locations";
Sub-part 5: "Ground vehicle installations";
Sub-part 6: "Ship environments";
Sub-part 7 : "Portable and non-stationary use";
Sub-part 8: "Stationary use at underground locations";
Part 2: "Specification of environmental tests". (See note 2.)
NOTE 1: Specifies different standardized environmental classes covering climatic and biological conditions,
chemically and mechanically active substances and mechanical conditions during storage, transportation
and in use. Sub-part 1-0 forms a general overview of part 1.
NOTE 2: Specifies the recommended test severities and test methods for the different environmental classes.
National transposition dates
Date of latest announcement of this EN (doa): 31 July 2003
Date of latest publication of new National Standard
or endorsement of this EN (dop/e): 31 January 2004
Date of withdrawal of any conflicting National Standard (dow): 31 January 2004
ETSI
5 ETSI EN 300 019-1-4 V2.1.2 (2003-04)
1 Scope
The purpose of the present document is to define a class of environmental conditions and their severities to which
equipment may be exposed. Only severe conditions, which may be harmful to the equipment, are included. The
severities specified are those which will have a low probability of being exceeded; generally less than 1 %.
The present document applies to equipment mounted for stationary use including periods of erection work, down time,
maintenance and repair at non-weatherprotected locations defined in clause 5.
2 References
The following documents contain provisions which, through reference in this text, constitute provisions of the present
document.
• References are either specific (identified by date of publication and/or edition number or version number) or
non-specific.
• For a specific reference, subsequent revisions do not apply.
• For a non-specific reference, the latest version applies.
Referenced documents which are not found to be publicly available in the expected location might be found at
http://docbox.etsi.org/Reference.
[1] IEC 60721-3-4: "Classification of environmental conditions - Part 3: Classification of groups of
environmental parameters and their severities - Section 4: Stationary use at non-weatherprotected
locations".
[2] IEC 60721-2-4: "Classification of environmental conditions - Part 2: Environmental conditions
appearing in nature. Solar radiation and temperature".
[3] IEC 60068-2-27: "Environmental testing. Part 2: Tests. Test Ea and guidance: Shock".
[4] IEC 60721-2-6: "Classification of environmental conditions. Part 2: Environmental conditions
appearing in nature - Earthquake vibration and shock".
[5] IEC 60068-3-3: "Environmental testing - Part 3: Guidance. Seismic test methods for equipment".
[6] ETSI EN 300 019-1-3: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 1-3: Classification of environmental
conditions; Stationary use at weatherprotected locations".
[7] ETSI EN 300 019-2-4: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 2-4: Specification of environmental
tests; Stationary use at non-weatherprotected locations".
[8] ETSI ETR 035: "Equipment Engineering (EE); Environmental engineering; Guidance and
terminology".
ETSI
6 ETSI EN 300 019-1-4 V2.1.2 (2003-04)
3 Definitions
For the purposes of the present document, the following terms and definitions apply:
absolute humidity: mass of water vapour in grammes which is associated with one cubic metre of dry air in an
air/water vapour mixture
non-weatherprotected location: location at which the equipment is not protected from direct weather influences
relative humidity: ratio of the partial pressure of the water vapour in moist air at a given temperature, to the partial
pressure of the water vapour in saturated air at the same temperature
stationary use: The equipment is mounted firmly on the structure, or on mounting devices, or it is permanently placed
at a certain site. It is not intended for portable use - but short periods of handling during erection works, down time,
maintenance and repair at the location are included.
4 Environmental classes
The classes shown in parentheses, e.g. (4C3), may be selected for special applications.
These classes apply to a non-weatherprotected location.
These classes apply to locations:
- which are directly exposed to an open-air climate, including solar radiation, movement of the surrounding air,
precipitation and water jets; splashing water;
- where mould growth, or attacks by animals but excluding termites, may occur;
- with normal levels of contaminants experienced in urban areas with industrial activities scattered over the
whole area and/or with heavy traffic. It also applies to coastal areas;
NOTE 1: At locations in the immediate neighbourhood of industrial sources with chemical emissions either special
precautions must be taken or a special chemical class must be chosen.
- in areas with sand or dust sources, including urban areas;
NOTE 2: At locations in geographical areas with wind-driven sand or dust in air special precautions must be taken
or a special class for mechanically active substances must be chosen.
- where transmitted vibrations are experienced from machines or passing vehicles. Higher level shocks may be
experienced e.g. from adjacent machines.
NOTE 3: More severe mechanical conditions are to be expected for equipment intended for public use. Special
requirements should be stated for such equipment, e.g. protection against vandalism.
If earthquake conditions can be expected, the conditions stated in clause 5.6 apply.
Two groups of classes are considered:
- Classes 4.1 and 4.1E apply to general
...