SIST EN 520:2005
(Main)Gypsum plasterboards - Definitions, requirements and test methods
Gypsum plasterboards - Definitions, requirements and test methods
This document specifies the characteristics and performance of gypsum plasterboards intended to be used in building construction works including those intended for secondary manufacturing operations. It includes boards designed to receive either direct surface decoration or gypsum plaster.
This document covers the following product performance characteristics: reaction to fire, water vapour permeability, flexural strength (breaking load), impact resistance and thermal resistance.
The following performance characteristics are linked to systems assembled with plasterboards: shear strength, fire resistance, impact resistance direct airborne sound insulation and acoustic absorption to be measured according to the corresponding European test methods. If required, tests should be done on assembled systems simulating the end use conditions.
This document covers also additional technical characteristics that are of importance for the use and acceptance of the product by the Construction Industry and the reference tests for these characteristics.
It provides for the evaluation of conformity of the product to this document.
This document does not cover plasterboards, which have been subject to any secondary manufacturing operations (e.g. insulating composite panels, plasterboards with thin lamination, etc.).
This document does not cover plasterboards, which have been subject to any secondary manufacturing operations (e.g. insulating composite panels, plasterboards with thin lamination, etc.).
Gipsplatten - Begriffe, Anforderungen und Prüfverfahren
Dieses Dokument legt Eigenschaften und Leistungsmerkmale für Gipsplatten fest, die in Bauwerken verwendet werden, einschließlich derer, die zur Weiterverarbeitung bestimmt sind. Es gilt auch für Platten, die zur direkten Aufnahme einer dekorativen Beschichtung oder eines Gipsputzes vorgesehen sind.
Dieses Dokument erfasst folgende Leistungsmerkmale des Produktes: Brandverhalten, Wasserdampfdurchlässigkeit, Biegezugfestigkeit (Bruchlast), Stoßfestigkeit und Wärmedurchlasswiderstand.
Die folgenden Leistungsmerkmale beziehen sich auf Systeme, die unter Verwendung von Gipsplatten hergestellt werden: Scherfestigkeit, Feuerwiderstand, Stoßfestigkeit Luftschalldämmung, Trittschalldämmung, Schallabsorption und Luftdurchlässigkeit, die nach den entsprechenden Europäischen Prüfverfahren zu bestimmen sind. Sofern erforderlich, werden Prüfungen an zusammengebauten Systemen, die dem Endzustand entsprechen, durchgeführt.
Dieses Dokument behandelt auch zusätzliche technische Eigenschaften, die für die Anwendung und Akzeptanz des Produktes durch die Bauwirtschaft wichtig sind. Es enthält auch die Referenzprüfverfahren für diese Eigenschaften.
Ferner legt es die Bewertung der Konformität der von diesem Dokument erfassten Produkte fest.
Dieses Dokument gilt nicht für Gipsplatten, die weiterverarbeitet wurden (z. B. zu Gipsplatten-Verbundelementen zur Schall- und Wärmedämmung, Gipsplatten mit dünnen Beschichtungen usw.).
Plaques de plâtre - Définitions, spécifications et méthodes d'essai
La présente Norme européenne définit les caractéristiques et les performances des plaques de plâtre conçues pour etre utilisées dans des ouvrages de construction immobiliere, y compris celles conçues pour des opérations de fabrication secondaires. Elle inclut les plaques destinées a recevoir directement une décoration sur leur face, ou un enduit au plâtre.
La présente norme couvre les caractéristiques de performance suivantes du produit : réaction au feu, perméabilité a la vapeur d'eau, résistance a la flexion (charge de rupture), résistance aux chocs et résistance thermique.
Les caractéristiques de performances suivantes sont liées a des systemes assemblés avec des plaques de plâtre : résistance au cisaillement, résistance au feu, isolation acoustique aux bruits aériens, isolation aux bruits d'impact, absorption acoustique et perméabilité a l'air, qui doivent etre mesurées conformément aux méthodes d'essai européennes correspondantes. Au besoin, il convient d'effectuer des essais sur des systemes assemblés qui simulent les conditions d'utilisation finale.
La présente Norme Européenne couvre également les caractéristiques techniques supplémentaires qui ont une incidence sur l'utilisation et la réception du produit par l'Industrie du Bâtiment et sur les essais de référence de ces caractéristiques.
Elle permet l'évaluation de la conformité du produit a la présente Norme européenne.
La présente norme ne couvre pas les plaques de plâtre qui ont subi des opérations de fabrication secondaires diverses (par exemple, les complexes d'isolation, les plaques avec revetements minces, etc.)
Mavčne plošče – Definicije, zahteve in preskusne metode
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 520:2005
01-februar-2005
0DYþQHSORãþH±'HILQLFLMH]DKWHYHLQSUHVNXVQHPHWRGH
Gypsum plasterboards - Definitions, requirements and test methods
Gipsplatten - Begriffe, Anforderungen und Prüfverfahren
Plaques de plâtre - Définitions, spécifications et méthodes d'essai
Ta slovenski standard je istoveten z: EN 520:2004
ICS:
01.040.91
91.100.10
SIST EN 520:2005 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
EUROPEAN STANDARD
EN 520
NORME EUROPÉENNE
EUROPÄISCHE NORM
November 2004
ICS 01.040.91; 91.100.10
English version
Gypsum plasterboards - Definitions, requirements and test
methods
Plaques de plâtre - Définitions, exigences et méthodes Gipsplatten - Begriffe, Anforderungen und Prüfverfahren
d'essai
This European Standard was approved by CEN on 16 August 2004.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the Central Secretariat or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the official
versions.
CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,
Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia,
Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36 B-1050 Brussels
© 2004 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 520:2004: E
worldwide for CEN national Members.
---------------------- Page: 2 ----------------------
EN 520:2004 (E)
Contents
page
Foreword.3
Introduction .4
1 Scope .6
2 Normative references .6
3 Terms and definitions .7
4 Requirements.11
5 Test methods.16
6 Evaluation of conformity.33
7 Designation of plasterboards .35
8 Marking, labelling and packaging .36
Annex A (informative) Sampling procedure for testing.37
A.1 General.37
A.2 Sampling procedure .37
A.2.1 Random sampling .37
A.2.2 Representative sampling .37
Annex B (normative) Conditions for reaction to fire classification of gypsum plasterboards without
further testing.39
B.0 Introduction.39
B.1 End use application.39
B.1.1 General.39
B.1.2 Mechanically fixed to a supporting sub-structure .39
B.1.3 Directly fixed or bonded to a solid substrate (dry lining system) .40
Annex C (normative) Mounting and fixing in the test according to EN 13823 (SBI test) .41
C.0 Introduction.41
C.1 General applications .41
C.2 Limited applications regarding joint filling .43
C.3 Limited applications regarding wood based substrates .44
Annex ZA (informative) Clauses of this European Standard addressing provisions of EU
Construction Products Directive.45
ZA.1 Scope and relevant characteristics .45
ZA.2 Attestation and declaration of conformity of gypsum plasterboards .46
ZA.3 CE marking and labeling.50
Bibliography .53
2
---------------------- Page: 3 ----------------------
EN 520:2004 (E)
Foreword
This document (EN 520:2004) has been prepared by Technical Committee CEN/TC 241 “Gypsum and gypsum
based products”, the secretariat of which is held by AFNOR.
This European Standard shall be given the status of a national standard, either by publication of an identical text or
by endorsement, at the latest by February 2005, and conflicting national standards shall be withdrawn at the latest
by August 2006.
This document has been prepared under a mandate given to CEN by the European Commission and the European
Free Trade Association, and supports essential requirements of EU Directive(s).
For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark,
Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta,
Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
3
---------------------- Page: 4 ----------------------
EN 520:2004 (E)
Introduction
Gypsum plasterboards are composed of a plaster core encased in, and firmly bonded to paper liners to form flat
rectangular boards. This composition allows them properties which makegypsum plasterboards particularly suitable
for use in situation where fire protection, sound and thermal insulation are required.
Gypsum plasterboards may be fixed by various methods e.g. nailing, screwing or sticking with gypsum based or
other adhesives. They may also be inserted in a suspended ceiling system.
Gypsum plasterboards are selected for use according to their type, size, thickness and edge profile. The boards
may be used for example to provide dry lining finishes to walls, to fixed and suspended ceilings, to partitions, or as
cladding to structural columns and beams. Other uses may be for flooring and sheathing application.
Diagrams 1 and 2 show the relationship between this standard and the package of standards prepared to support
the families of gypsum and ancillary products.
Diagram 1 — Family of gypsum products
4
---------------------- Page: 5 ----------------------
EN 520:2004 (E)
.
Diagram 2 — Family of ancillary products
5
---------------------- Page: 6 ----------------------
EN 520:2004 (E)
1 Scope
This document specifies the characteristics and performance of gypsum plasterboards intended to be used in
building construction works including those intended for secondary manufacturing operations. It includes boards
designed to receive either direct surface decoration or gypsum plaster.
This document covers the following product performance characteristics: reaction to fire, water vapour permeability,
flexural strength (breaking load), impact resistance and thermal resistance.
The following performance characteristics are linked to systems assembled with plasterboards: shear strength, fire
resistance, impact resistance direct airborne sound insulation and acoustic absorption to be measured according to
the corresponding European test methods. If required, tests should be done on assembled systems simulating the
end use conditions.
This document covers also additional technical characteristics that are of importance for the use and acceptance of
the product by the Construction Industry and the reference tests for these characteristics.
It provides for the evaluation of conformity of the product to this document.
This document does not cover plasterboards, which have been subject to any secondary manufacturing operations
(e.g. insulating composite panels, plasterboards with thin lamination, etc.).
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references,
only the edition cited applies. For undated references, the latest edition of the referenced document (including any
amendments) applies.
EN 336, Structural timber —Sizes, permitted deviations
EN 338, Structural timber — Strength classes
EN 1995-1-1, Eurocode 5 — Design of timber structures
EN 12114, Thermal performance of buildings — Air permeability of building components and building elements —
Laboratory test method
EN 12524, Building materials and products — Hygrothermal properties — Tabulated design values
EN 12664, Thermal performance of building materials and products — Determination of thermal resistance by
means of guarded hot plate and heat flow meter methods — Dry and moist products of medium and low thermal
resistance
EN 13501-1, Fire classification of construction products and building elements — Part 1: Classification using test
data from reaction to fire tests
EN 13501-2, Fire classification of construction products and building elements — Part 2: Classification using data
from fire resistance tests, excluding ventilation services
EN 13823, Reaction to fire tests for building products — Building products excluding floorings exposed to the
thermal attack by a single burning item
prEN 13963, Jointing materials for gypsum plasterboards — Definitions, requirements and test methods
EN 14195, Metal framing components for gypsum plasterboard systems — Definitions, requirements and test
methods
6
---------------------- Page: 7 ----------------------
EN 520:2004 (E)
prEN 14566, Mechanical fasteners for gypsum plasterboard systems — Definitions, requirements and test methods
EN ISO 140-3, Acoustics — Measurement of sound insulation in buildings and of building elements — Part 3:
Laboratory measurements of airborne sound insulation of building elements (ISO 140-3:1995).
EN ISO 354, Acoustics — Measurement of sound absorption in a reverberation room (ISO 354:2003)
EN ISO 536, Paper and board — Determination of grammage (ISO 536:1995).
EN ISO 717-1, Acoustics — Rating of sound insulation in buildings and of building elements — Part 1: Airborne
sound insulation (ISO 717-1:1996).
EN ISO 12572, Hygrothermal performance of building materials and products — Determination of water vapour
transmission properties (ISO 12572:2001).
EN ISO 20535, Paper and board — Determination of water absorptiveness — Cobb method (ISO 535:1991).
ISO 7892, Vertical building elements — Impact resistance tests — Impact bodies and general test procedures.
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1 gypsum plasterboard
product composed of a plaster core encased in, and firmly bonded to strong durable paper liner to form a flat
rectangular board. The paper surfaces may vary according to the use of the particular type of board and the core
may contain additives to impart additional properties. The longitudinal edges are paper-covered and profiled to suit
the application
3.1.2
edge
paper-covered longitudinal side
3.1.3
end
side transverse to the edges, showing exposed core
3.1.4
face
surface on which the paper extends continuously to cover the edges
3.1.5
back
surface opposite to the face
3.1.6
width
shortest distance between the edges of the board
3.1.7
nominal width (w)
width stated by the producer
3.1.8
length
shortest distance between the ends of the board
7
---------------------- Page: 8 ----------------------
EN 520:2004 (E)
3.1.9
nominal length (l)
length stated by the producer
3.1.10
thickness
distance between the face and the back, excluding edge profiles
3.1.11
nominal thickness (t)
thickness stated by the producer
3.1.12
squareness (s)
rectangularity of the board
3.2 Types of gypsum plasterboards
3.2.1 General
The performance of the types of gypsum plasterboards defined below may be combined in one board in which case
the letter identifying each type of performance satisfied shall be given in the designation.
3.2.2
gypsum plasterboard Type A
plasterboard with a face to which suitable gypsum plasters or decoration may be applied. For the purposes of
identification these boards are designated Type A
3.2.3
gypsum plasterboard Type H (plasterboard with reduced water absorption rate)
types of boards which have additives to reduce the water absorption rate. They may be suitable for special
applications in which reduced water absorption properties are required to improve the performance of the board.
For the purposes of identification, these boards are designated Type H1, H2 and H3, with different water absorption
performance
3.2.4
gypsum plasterboard Type E (gypsum sheathing board)
boards specially manufactured to be used as sheathing board in external walls. They are not intended to receive
decoration. They are not designed to be permanently exposed to external weather conditions. This type of
wallboard has reduced water absorption rate. They shall have a minimum water vapour permeability. For the
purposes of identification these boards are designated Type E
3.2.5
gypsum plasterboard Type F (gypsum plasterboard with improved core adhesion at high temperature)
plasterboard with a face to which suitable gypsum plasters or decoration may be applied. These boards have
mineral fibres and/or other additives in the gypsum core to improve core cohesion at high temperatures. For the
purposes of identification these boards are designated Type F
3.2.6
gypsum plasterboard Type P (gypsum baseboard)
boards which have a face intended to receive gypsum plaster. They may be perforated during manufacture. For the
purposes of identification these boards are designated Type P
3.2.7
gypsum plasterboard Type D (gypsum plasterboard with controlled density
These boards have a controlled density, with a face to which suitable gypsum plasters or decoration may be
applied. This enables improved performance in certain applications to be obtained. For the purposes of
identification these boards are designated Type D
8
---------------------- Page: 9 ----------------------
EN 520:2004 (E)
3.2.8
gypsum plasterboard Type R (gypsum plasterboard with enhanced strength)
These boards for special applications where higher strength is required have both increased longitudinal and
transverse breaking loads. They have a face to which suitable gypsum plasters or decoration may be applied. For
the purposes of identification these boards are designated Type R
3.2.9
gypsum plasterboard Type I (gypsum plasterboard with enhanced surface hardness)
These boards are used for applications where higher surface hardness is required. They have a face to
which suitable gypsum plasters or decoration may be applied. For the purposes of identification these
boards are designated Type I3.3 Edge and end profiles of gypsum plasterboards
The paper-covered edges of gypsum plasterboard are square, bevelled, tapered, half-rounded or rounded, or a
combination of each (see examples in Figures 1 to 6).
The paper-covered edges of type P (gypsum baseboard) are square or rounded.
The ends of gypsum plasterboard are normally square cut.
Key
1 Face
2 Back
Figure 1 — Square edge
9
---------------------- Page: 10 ----------------------
EN 520:2004 (E)
Key
1 Face
2 Back
Figure 2 — Bevelled edge
Key
1 Face
2 Back
Figure 3 — Tapered edge
Key
1 Face
2 Back
Figure 4 — Half-rounded edge
10
---------------------- Page: 11 ----------------------
EN 520:2004 (E)
Key
1 Face
2 Back
Figure 5 — Half-rounded tapered edge
Key
1 Face
2 Back
Figure 6 — Rounded edge
4 Requirements
4.1 Mechanical characteristics
4.1.1 Shear strength (strength of board/substructure connection)
When the intended use of plasterboards is for stiffening timber framed building assemblies (i.e. walls, partitions,
roof truss structures, etc.), the conventional shear strength of the plasterboard shall be determined in accordance
with the test method described in 5.13.
NOTE It should be noted that this test does not measure the actual shear strength of the board but rather the strength of
the board/substructure connection that is the relevant property for this application.
4.1.2 Flexural strength (expressed as flexural breaking load)
4.1.2.1 The flexural breaking load of gypsum plasterboard types A, D, E, F, H, I determined in accordance with
the test method described in 5.7, shall not be less than the values given in Table 1.
Additionally, no individual test shall demonstrate the product to be more than 10 % below the values given in
Table 1.
11
---------------------- Page: 12 ----------------------
EN 520:2004 (E)
Table 1 — Flexural breaking load of gypsum plasterboards (Types A, D, E, F, H, I)
Nominal board thickness Flexural breaking load
Thickness mm N
Transverse direction Longitudinal direction
9,5 160 400
Common 12,5 210 550
15,0 250 650
Other thickness t
16,8 ⋅ t 43 ⋅ t
4.1.2.2 The flexural breaking load of enhanced strength gypsum plasterboard type R, or combined determined
in accordance with the test method described in 5.7, shall not be less than the values given in Table 2.
Additionally, no individual test shall demonstrate the product to be more than 10 % below the values given in
Table 2.
Table 2 — Flexural breaking load of enhanced strength gypsum plasterboards (Type R or combined)
Nominal board thickness Flexural breaking load
Thickness
mm N
Transverse direction Longitudinal direction
12,5 300 725
Common
15,0 360 870
Other thickness t 24 ⋅ t 58 ⋅ t
4.1.2.3 The flexural breaking load of gypsum baseboards (type P) determined as described in 5.7, shall not be
less than the values given in Table 3.
In addition, no individual test shall demonstrate the product to be more than 10 % below the values given in Table 3.
Table 3 — Flexural breaking load of gypsum baseboards (Type P)
Nominal board thickness Flexural breaking load
mm N
Transverse direction Longitudinal direction
9,5 125 180
12,5 165 235
4.1.3 Deflection under load
When required, the deflection under load shall be determined in accordance with the test method described in 5.8.
4.2 Fire behaviour
4.2.1 Reaction to fire
Where subject to regulatory requirements, the plasterboard shall either be Classified Without Further Testing
according to the provisions of Annex B or it shall be tested and classified according to EN 13501-1.
12
---------------------- Page: 13 ----------------------
EN 520:2004 (E)
Plasterboards tested according to EN 13823 (SBI test) shall be mounted and fixed in accordance with Annex C or
when the producer wishes to claim performance for a specific intended use, the mounting and fixing shall be
representative of that intended use.
When required, the paper grammage shall be determined according to EN ISO 536.
4.2.2 Resistance to fire
NOTE Resistance to fire is a characteristic dependent on an assembled system and not of the product in isolation.
When required, the fire resistance of a system including gypsum plasterboard shall be classified in accordance with
EN 13501-2.
4.3 Impact resistance
NOTE Impact resistance is a characteristic dependent on an assembled system and not of the product in isolation.
When required, the impact resistance of a system including gypsum plasterboard shall be determined in
accordance with ISO 7892.
4.4 Water vapour permeability (expressed as water vapour resistance factor)
When the intended use of gypsum plasterboards is for moisture diffusion control, tabulated design values of water
vapour resistance factor for gypsum plasterboards given in EN 12524 may be used.
Alternatively, the water vapour resistance factor shall be determined using the method given in EN ISO 12572.
4.5 Air permeability
When the intended use of gypsum plasterboards is sheathing in external walls, a design value of
-6 3 2
1,4 x 10 m /m ·s·Pa may be used for air permeability of gypsum plasterboards.
When required, air permeability shall be determined in accordance with EN 12114.
4.6 Acoustic properties
4.6.1 Direct airborne sound insulation
NOTE Direct airborne sound insulation is a characteristic dependent on an assembled system and not of the product in
isolation.
When required, the direct airborne sound insulation of a system including gypsum plasterboard shall be determined
in accordance with EN ISO 140-3 and EN ISO 717-1.
4.6.2 Acoustic absorption
NOTE Acoustic absorption is a characteristic dependent on an assembled system and not of the product in isolation.
When plasterboards are intended to be used for acoustic conditioning, acoustic absorption shall be measured
according to EN ISO 354.
4.7 Thermal resistance (expressed as thermal conductivity)
When the intended use of plasterboards is to contribute to thermal resistance in building construction works (walls,
partitions, ceilings, etc.), the design values of thermal conductivity for gypsum plasterboards given in EN 12524
may be used.
When required, thermal conductivity shall be determined in accordance with EN 12664.
13
---------------------- Page: 14 ----------------------
EN 520:2004 (E)
4.8 Regulated substances
Materials used in products shall not release any regulated substances in excess of the maximum permitted levels
specified in a relevant document for the material or permitted in the national regulations of the member state of
destination.
4.9 Dimensions and tolerances
4.9.1 Gypsum plasterboards Type P (baseboard)
4.9.1.1 Width
NOTE Common nominal widths are 400 mm, 600 mm, 900 mm and 1 200 mm. Other widths are also possible.
The width shall be measured as described in 5.2 and compared to the nominal width.
0
The tolerance shall be mm.
−8
4.9.1.2 Length
NOTE Common nominal lengths are 1 200 mm, 1 500 mm, 1 800 mm and 2 000 mm. Other lengths are also possible.
The length shall be measured as described in 5.3 and compared to the nominal length.
0
The tolerance shall be mm.
−6
4.9.1.3 Thickness
NOTE The nominal thicknesses are normally 9,5 mm and 12,5 mm.
The thickness shall be measured as described in 5.4 and compared to the nominal thickness.
The tolerance shall be ± 0,6 mm.
4.9.2 Gypsum plasterboards Types A, H, D, E, F, I, R or combined
4.9.2.1 Width
NOTE Common nominal widths are 600 mm, 625 mm, 900 mm, 1 200 mm and 1 250 mm. Other widths are also possible.
The width shall be measured as described in 5.2 and compared to the nominal width.
0
The tolerance shall be mm for each individual measurement.
−4
4.9.2.2 Length
The length shall be measured as described in 5.3 and compared to the nominal length.
0
The tolerance shall be mm for each individual measurement.
−5
4.9.2.3 Thickness
NOTE Common nominal thicknesses are 9,5 mm, 12,5 mm and 15 mm. Other nominal thicknesses are also possible.
The nominal thickness shall be at least 6,0 mm.
14
---------------------- Page: 15 ----------------------
EN 520:2004 (E)
The thickness shall be measured as described in 5.4 and compared to the nominal thickness.
Tolerances for nominal thicknesses below 18 mm shall be ± 0,5 mm.
For boards of nominal thickness equal to or greater than 18 mm, the tolerance shall be ± (0,04 x thickness) (in mm)
rounded to the nearest 0,1 mm.
The difference between individual thickness measurements on any individual board shall not exceed 0,8 mm.
4.9.2.4 Squareness of ends
The deviation from squareness measured as described in 5.5 shall not exceed 2,5 mm per metre of width.
4.9.2.5 Edge and end profiles
The edge and end profiles may vary widely depending upon the jointing system and decorative and aesthetic
considerations. The exception is the tapered edge and the half-rounded tapered edge profile.
For the tapered edge and the half-rounded tapered edge profile, when measured as described in 5.6, each
individual reading shall be between the following limits:
depth of taper: between 0,6 mm and 2,5 mm;
width of taper: between 40 mm and 80 mm.
4.10 Additional requirements for gypsum plasterboards Types H1, H2, H3 (with reduced water
absorption)
4.10.1 Surface water absorption
The surface water absorption of the board type H determined by the method described in 5.9.1 either for the face or
2
for the back, shall not be greater than 180 g/m .
4.10.2 Total water absorption
The total water absorption of boards, determined by the method described in 5.9.2, shall not be greater than the
values shown in Table 4.
Table 4 — Water absorption classes
Water absorption classes Total water absorption
%
H1
≤ 5
H2 ≤ 10
H3
≤ 25
4.11 Additional requirements for gypsum plasterboards Type E (sheathing boards)
This type of boards shall conform to type H1, H2 or H3 requirements.
The water vapour resistance factor of boards type E determined in accordance with the method described in
EN ISO 12572 shall not be greater than 25.
15
---------------------- Page: 16 ----------------------
EN 520:2004 (E)
4.12 Additional requirements for gypsum plasterboards Type F (with improved core cohesion at
high temperature)
When a type F plasterboard (or combined) is subjected to the test described in 5.10, none of the 6 specimens shall
break.
4.13 Additional requirements for gypsum plasterboards Type D (with controlled density)
The density of gypsum plasterboard type D (or combined) determined as described in 5.11, shall be at least
3 3
0,8 x 10 kg/m .
4.14 Additional requirements for gypsum plasterboards Type I (with enhanced surface hardness)
The surface hardness of gypsum plasterboard type I (or combined) is characterised by the diameter of the
depression produced in the surface according to the test method described in 5.12.
The diameter of the depression shall not be greater than 15 mm.
5 Test methods
5.1 Sampling
Testing shall require three boards of each type and thickness on which tests as described in 5.2 to 5.6 to be carried
out.
Tests according to 5.7 to 5.12 shall be carried out on specimens cut out from the same three boards.
5.2 Determination of width
5.2.1 Principle
The width shall be measured at 3 positions along the length of the board.
5.2.2 Apparatus
A metal rule or tape permitting readings to 1 mm.
5.2.3 Procedure
Take three measurements between the extremities of the boards (see Figure 7) to the nearest 1 mm, one near
each end and one near the middle of the board.
16
---------------------- Page: 17 ----------------------
EN 520:2004 (E)
Figure 7 — Determination of width
5.2.4 Expression of results
Each measured value expressed in mm shall be recorded.
5.3 Determination of length
5.3.1 Principle
The length shall be measured at 3 positions across the width of the board.
5.3.2 Apparatus
A metal rule or tape permitting readings to 1 mm.
Figure 8 — Determinatio
...
Questions, Comments and Discussion