Electromagnetic compatibility and Radio spectrum Matters (ERM); Land Mobile Service; Radio equipment for analogue and/or digital communication (speech and/or data) and operating on narrow band channels and having an antenna connector; Part 1: Technical characteristics and methods of measurement

Editorial update of EN 301 166 consequent to the publication of part 2

Elektromagnetna združljivost in zadeve v zvezi z radijskim spektrom (ERM) – Kopenske mobilne storitve – Radijska oprema za analogne oziroma digitalne komunikacije (prenos govora oziroma podatkov), ki deluje v ozkopasovnih kanalih in ima antenski konektor – 1. del: Tehnične karakteristike in merilne metode

General Information

Status
Published
Publication Date
30-Nov-2003
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Dec-2003
Due Date
01-Dec-2003
Completion Date
01-Dec-2003

Buy Standard

Standard
EN 301 166-1 V1.1.2:2003
English language
97 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.LJLWDOQHElectromagnetic compatibility and Radio spectrum Matters (ERM); Land Mobile Service; Radio equipment for analogue and/or digital communication (speech and/or data) and operating on narrow band channels and having an antenna connector; Part 1: Technical characteristics and methods of measurement33.100.01Elektromagnetna združljivost na splošnoElectromagnetic compatibility in general33.070.01Mobilni servisi na splošnoMobile services in general33.060.99Druga oprema za radijske komunikacijeOther equipment for radiocommunicationsICS:Ta slovenski standard je istoveten z:EN 301 166-1 Version 1.1.2SIST EN 301 166-1 V1.1.2:2003en01-december-2003SIST EN 301 166-1 V1.1.2:2003SLOVENSKI
STANDARD



SIST EN 301 166-1 V1.1.2:2003



ETSI EN 301 166-1 V1.1.2 (2001-12)European Standard (Telecommunications series) Electromagnetic compatibilityand Radio spectrum Matters (ERM);Land Mobile Service;Radio equipment for analogue and/or digitalcommunication (speech and/or data) and operating onnarrow band channels and having an antenna connector;Part 1: Technical characteristics andmethods of measurement SIST EN 301 166-1 V1.1.2:2003



ETSI ETSI EN 301 166-1 V1.1.2 (2001-12) 2
Reference REN/ERM-TG32-045-1 Keywords analogue, antenna, connector, data, digital, mobile, PMR, radio, speech ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE
Tel.: +33 4 92 94 42 00
Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - NAF 742 C Association à but non lucratif enregistrée à la Sous-Préfecture de Grasse (06) N° 7803/88
Important notice Individual copies of the present document can be downloaded from: http://www.etsi.org The present document may be made available in more than one electronic version or in print. In any case of existing or perceived difference in contents between such versions, the reference version is the Portable Document Format (PDF). In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the document may be subject to revision or change of status. Information on the current status of this and other ETSI documents is available at http://portal.etsi.org/tb/status/status.asp If you find errors in the present document, send your comment to: editor@etsi.fr Copyright Notification No part may be reproduced except as authorized by written permission. The copyright and the foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 2001. All rights reserved.
SIST EN 301 166-1 V1.1.2:2003



ETSI ETSI EN 301 166-1 V1.1.2 (2001-12) 3 Contents Intellectual Property Rights.8 Foreword.8 Introduction.9 1 Scope.10 2 References.10 3 Definitions, symbols and abbreviations.11 3.1 Definitions.11 3.2 Symbols.13 3.3 Abbreviations.13 4 General.13 4.1 Presentation of equipment for testing purposes.13 4.1.1 Choice of model for type testing.14 4.1.2 Definitions of Switching Range (SR), alignment range and operating frequency range.14 4.1.2.1 Definition of SR.14 4.1.2.2 Definition of alignment range.14 4.1.2.3 Definition of Operating Frequency Range (OFR).14 4.1.3 Definition of the categories of the alignment range (AR0, AR1, AR2 and AR3).14 4.1.4 Testing of equipment of category AR0.15 4.1.5 Testing of equipment of category AR1.15 4.1.6 Testing of equipment of category AR2.15 4.1.7 Testing of equipment of category AR3.15 4.1.8 Testing of equipment capable of being aligned to operate with more than one Channel Separation (CSP).15 4.1.9 Number of samples for type testing.15 4.1.10 Testing of a family of equipment with a total operating range in excess of each equipment's alignments range.16 4.1.11 Testing of equipment with alternative power levels.16 4.1.12 Testing of equipment with alternative hardware configurations.16 4.1.13 Testing of equipment that does not have an external 50 Ω RF connector (integral antenna equipment).16 4.1.13.1 Equipment with an internal permanent or temporary antenna connector.16 4.1.13.2 Equipment with a temporary antenna connector.17 4.2 Testing using bit streams or messages.17 4.3 Interpretation of the measurement results.17 4.4 Transmitter power.17 4.5 Facilities sockets.17 5 Test conditions, power sources and ambient temperatures.18 5.1 Normal and extreme test conditions.18 5.2 Test power source.18 5.3 Normal test conditions.18 5.3.1 Normal temperature and humidity.18 5.3.2 Normal test power source.18 5.3.2.1 Mains voltage.18 5.3.2.2 Regulated lead-acid battery power sources used on vehicles.18 5.3.2.3 Other power sources.19 5.4 Extreme test conditions.19 5.4.1 Extreme temperatures.19 5.4.2 Extreme test source voltages.19 5.4.2.1 Mains voltage.19 5.4.2.2 Regulated lead-acid battery power sources used on vehicles.19 5.4.2.3 Power sources using other types of batteries.19 5.4.2.4 Other power sources.19 5.5 Procedure for tests at extreme temperatures.20 SIST EN 301 166-1 V1.1.2:2003



ETSI ETSI EN 301 166-1 V1.1.2 (2001-12) 4 5.5.1 Procedure for equipment designed for continuous transmission.20 5.5.2 Procedure for equipment designed for intermittent transmission.20 6 General conditions.20 6.1 Test signals.20 6.1.1 Transmitter test signals (B1), (M5) and (M7).20 6.1.2 Receiver test signal for analogue equipment.21 6.1.3 Receiver test signals for data (and digitized voice) equipment (M2), (M3), (M4) and (M6).21 6.1.4 Transmitter effective radiated power test signal (C1).21 6.2 Test load (artificial antenna).21 6.3 PEP.22 6.4 Encoders.22 6.5 Modulation processing.22 6.6 Test sites and general arrangements for radiated measurements.22 6.7 Transmitter automatic shut-off facility.22 6.8 Arrangement for analogue test signals at the input of the transmitter.22 6.9 Arrangement for test signals at the input of the receiver.22 6.10 Receiver mute or squelch facility.23 6.11 Receiver rated audio output power.23 6.12 Facilities for access.23 6.12.1 Analogue access.23 6.12.2 Test points for bit stream measurements.23 6.12.3 Coupling arrangements.23 6.12.3.1 Arrangements for measurements with continuous bit streams.23 6.12.3.2 Arrangements for measurements with messages.24 6.12.4 Modes of operation of the transmitter.24 6.13 Tests of equipment with a duplex filter.24 7 Technical characteristics of the transmitter.24 7.1 Maximum power (PX) (conducted).24 7.1.1 Definition.24 7.1.2 Method of measurement.24 7.1.3 Limit.25 7.2 Maximum effective radiated power.25 7.2.1 Definition.25 7.2.2 Method of measurement.25 7.2.2.1 Evaluation of CW-to-PEP correction factor for signal C1.25 7.2.2.2 Measurements on a test site.25 7.2.3 Limit.26 7.3 Adjacent and alternate channels power.27 7.3.1 Definition.27 7.3.2 Methods of measurement.27 7.3.3 Limit.28 7.4 Spurious emissions.29 7.4.1 Definition.29 7.4.2 Method of measurement.29 7.4.2.1 Method of measuring conducted spurious emissions in a specified load (clause 7.4.1 (a)).29 7.4.2.2 Method of measuring the effective radiated power (clause 7.4.1 (b)).29 7.4.2.3 Method of measuring the effective radiated power (clause 7.4.1 (c)).30 7.4.3 Limits.31 7.5 Intermodulation attenuation.31 7.5.1 Definition.31 7.5.2 Method of measurement.32 7.5.3 Limits.33 7.6 Transient power.33 7.6.1 Definition.33 7.6.2 Method of measurement.33 7.6.2.1 Characteristics of the transient power measuring device.34 7.6.3 Limits.34 7.7 Frequency error.34 7.7.1 Definition.34 7.7.2 Method of measurement.35 SIST EN 301 166-1 V1.1.2:2003



ETSI ETSI EN 301 166-1 V1.1.2 (2001-12) 5 7.7.3 Limits.35 8 Technical characteristics of the receiver.36 8.1 Maximum usable sensitivity (analogue, conducted).36 8.1.1 Definition.36 8.1.2 Method of measuring the SINAD ratio.36 8.1.3 Limits.36 8.2 Maximum usable sensitivity (analogue, field strength).36 8.2.1 Definition.37 8.2.2 Method of measurement.37 8.2.3 Limits.38 8.3 Maximum usable sensitivity (data, conducted).38 8.3.1 Definition.38 8.3.2 Methods of measurement.38 8.3.2.1 Method of measurement with continuous bit streams.38 8.3.2.2 Method of measurement with messages.39 8.3.3 Limits.39 8.4 Maximum usable sensitivity (data, field strength).39 8.4.1 Definition.40 8.4.2 Method of measurement.40 8.4.2.1 Method of measurement with continuous bit streams.40 8.4.2.2 Method of measurement with messages.41 8.4.3 Limits.42 8.5 Adjacent channel selectivity.43 8.5.1 Definition.43 8.5.2 Method of measurement.43 8.5.2.1 Method of measurement (analogue).43 8.5.2.2 Method of measurement (data with continuous bit stream).44 8.5.2.3 Method of measurement with messages.44 8.5.3 Limits.45 8.6 Spurious response rejection.45 8.6.1 Definition.46 8.6.2 Method of measurement.46 8.6.2.1 Introduction to the method of measurement.46 8.6.2.2 Method of search over the "limited frequency range".46 8.6.2.3 Method of measurement (analogue).47 8.6.2.4 Method of measurement (data with continuous bit streams).48 8.6.2.5 Method of measurement (data with messages).48 8.6.3 Limits.49 8.7 Intermodulation response rejection.49 8.7.1 Definition.49 8.7.2 Method of measurement.50 8.7.2.1 Method of measurement (analogue).50 8.7.2.2 Method of measurement (data with continuous bit stream).51 8.7.2.3 Method of measurement with messages.51 8.7.3 Limit.52 8.8 Blocking or desensitization.53 8.8.1 Definition.53 8.8.2 Method of measurement.53 8.8.2.1 Method of measurement (analogue).53 8.8.2.2 Method of measurement (data with continuous bit stream).54 8.8.2.3 Method of measurement with messages.54 8.8.3 Limit.55 8.9 Spurious radiations.55 8.9.1 Definition.55 8.9.2 Methods of measurement.56 8.9.2.1 Method of measuring the power level in a specified load (clause 8.9.1a)).56 8.9.2.2 Method of measuring the effective radiated power (clause 8.9.1b)).56 8.9.2.3 Method of measuring the effective radiated power (clause 8.9.1.c).57 8.9.3 Limits.57 8.10 Co-channel rejection.57 8.10.1 Definition.57 SIST EN 301 166-1 V1.1.2:2003



ETSI ETSI EN 301 166-1 V1.1.2 (2001-12) 6 8.10.2 Methods of measurement.58 8.10.2.1 Method of measurement (analogue).58 8.10.2.2
Method of measurement (data with continuous bit stream).58 8.10.2.3 Method of measurement with messages.
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.