SIST EN 61000-5-5:1997
(Main)Electromagnetic compatibility (EMC) -- Part 5: Installation and mitigation guidelines -- Section 5: Specification of protective devices for HEMP conducted disturbance
Electromagnetic compatibility (EMC) -- Part 5: Installation and mitigation guidelines -- Section 5: Specification of protective devices for HEMP conducted disturbance
This part of 61000-5 defines how protective devices for conducted disturbance proposed for HEMP protection shall be specified. It is intended to be used for the harmonization of existing or future specifications issued by protective device manufacturers, electronic equipment manufacturers, administrations and other ultimate buyers. Performance requirements shall be given in future IEC documents. This section covers protective devices currently being used for protection against induced HEMP transients on signal and low voltage power lines (nominal voltage up to 1 kV a.c.). General information can be applied also to high voltage lines. However, in these cases, the additional requirements for the protection levels of existing lightning arresters (especially gapless MO-arresters) are under consideration.
Elektromagnetische Verträglichkeit (EMV) -- Teil 5: Installationsrichtlinien und Abhilfemaßnahmen -- Hauptabschnitt 5: Festlegung von Schutzeinrichtungen gegen leitungsgeführte HEMP-Störgrößen
Compatibilité électromagnétique (CEM) -- Partie 5: Guides d'installation et d'atténuation -- Section 5: Spécification des dispositifs de protection pour perturbations conduites IEMN-HA
La présente section de la CEI 61000-5 définit comment les dispositifs de protection contre les perturbations conduites proposés pour la protection IEMN doivent être spécifiés. Elle a pour but d'harmoniser les spécifications, existantes ou à venir, issues des fabricants de protections, des fabricants d'équipements électroniques, des administrations et autres exploitants. Les exigences de performances seront données dans des documents futurs de la CEI. Cette section couvre les protections utilisées couramment pour la protection contre les transitoires induits par l'IEMN-HA sur les acccès signaux et les accès énergie basse tension (tension nominale) jusqu'à 1 kV alternatif). Les généralités peuvent aussi être appliquées à des accès haute tension; cependant, dans ce cas, les exigences additionnelles pour les niveaux de protection des parafoudres (spécialement les parafoudres à oxyde métallique) sont à l'étude.
Electromagnetic compatibility (EMC) - Part 5: Installationand mitigation guidelines - Section 5: Specification of protective devices for HEMP conducted disturbance - Basic EMC publication (IEC 1000-5-5:1996)
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 61000-5-5:1997
01-marec-1997
Electromagnetic compatibility (EMC) - Part 5: Installationand mitigation guidelines
- Section 5: Specification of protective devices for HEMP conducted disturbance -
Basic EMC publication (IEC 1000-5-5:1996)
Electromagnetic compatibility (EMC) -- Part 5: Installation and mitigation guidelines --
Section 5: Specification of protective devices for HEMP conducted disturbance
Elektromagnetische Verträglichkeit (EMV) -- Teil 5: Installationsrichtlinien und
Abhilfemaßnahmen -- Hauptabschnitt 5: Festlegung von Schutzeinrichtungen gegen
leitungsgeführte HEMP-Störgrößen
Compatibilité électromagnétique (CEM) -- Partie 5: Guides d'installation et d'atténuation -
- Section 5: Spécification des dispositifs de protection pour perturbations conduites IEMN
-HA
Ta slovenski standard je istoveten z: EN 61000-5-5:1996
ICS:
33.100.01 Elektromagnetna združljivost Electromagnetic compatibility
na splošno in general
SIST EN 61000-5-5:1997 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 61000-5-5:1997
---------------------- Page: 2 ----------------------
SIST EN 61000-5-5:1997
---------------------- Page: 3 ----------------------
SIST EN 61000-5-5:1997
---------------------- Page: 4 ----------------------
SIST EN 61000-5-5:1997
---------------------- Page: 5 ----------------------
SIST EN 61000-5-5:1997
---------------------- Page: 6 ----------------------
SIST EN 61000-5-5:1997
---------------------- Page: 7 ----------------------
SIST EN 61000-5-5:1997
---------------------- Page: 8 ----------------------
SIST EN 61000-5-5:1997
---------------------- Page: 9 ----------------------
SIST EN 61000-5-5:1997
---------------------- Page: 10 ----------------------
SIST EN 61000-5-5:1997
---------------------- Page: 11 ----------------------
SIST EN 61000-5-5:1997
---------------------- Page: 12 ----------------------
SIST EN 61000-5-5:1997
---------------------- Page: 13 ----------------------
SIST EN 61000-5-5:1997
---------------------- Page: 14 ----------------------
SIST EN 61000-5-5:1997
---------------------- Pa
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.