This part of IEC 60317 specifies general requirements of glass-fibre wound, resin or varnish
impregnated, bare or enamelled rectangular copper wire.
The range of nominal conductor dimensions is given in the relevant specification sheet.

Technische Lieferbedingungen für bestimmte Typen von Wickeldrähten - Teil 0-4: Allgemeine Anforderungen - Flachdrähte aus Kupfer, blank oder lackisoliert und umhüllt mit Glasgewebe, imprägniert mit Harz oder Lack

Spécifications pour types particuliers de fils de bobinage - Partie 0-4: Exigences générales - Fil de section rectangulaire en cuivre nu ou émaillé, guipé de fibres de verre imprégnées de vernis ou de résine

L'IEC 60317-0-4:2015 spécifie les exigences générales relatives au fil de section rectangulaire en cuivre nu ou émaillé guipé de fibres de verre imprégnées de vernis ou de résine. La plage des dimensions nominales des conducteurs est donnée dans la feuille particulière concernée. Cette troisième édition annule et remplace la deuxième édition parue en 1997, l'Amendement 1:1999 et l'Amendement 2:2005. Cette édition constitue une révision technique. Cette édition inclut les modifications techniques majeures suivantes par rapport à l'édition précédente:
- ajout d'exigences relatives aux dimensions pour le fil émaillé de grade 1 dans le Tableau 4;
- ajout d'exigences relatives au claquage pour le fil émaillé de grade 1 dans le Tableau 7.
Mots clés: fils isolés utilisés pour les enroulements, fil de cuivre

Specifikacije za posebne vrste navijalnih žic - 0-4. del: Splošne zahteve - Bakrena žica s pravokotnim prerezom, gola ali emajlirana, ovita z optičnimi vlakni in impregnirana s smolo ali lakom

Ta del standarda IEC 60317 določa splošne zahteve za bakreno žico s pravokotnim prerezom, golo ali emajlirano, ovito z optičnimi vlakni in impregnirano s smolo ali lakom. Obseg nazivnih mer kondenzatorja je podan v ustrezni razpredelnici.

General Information

Status
Withdrawn
Publication Date
22-Feb-2016
Withdrawal Date
07-Jun-2023
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
07-Jun-2023
Due Date
30-Jun-2023
Completion Date
08-Jun-2023

Relations

Buy Standard

Standard
EN 60317-0-4:2016
English language
27 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 60317-0-4:2016
01-april-2016
1DGRPHãþD
SIST EN 60317-0-4:2001
SIST EN 60317-0-4:2001/A1:2001
SIST EN 60317-0-4:2001/A2:2006
6SHFLILNDFLMH]DSRVHEQHYUVWHQDYLMDOQLKåLFGHO6SORãQH]DKWHYH%DNUHQD
åLFDVSUDYRNRWQLPSUHUH]RPJRODDOLHPDMOLUDQDRYLWD]RSWLþQLPLYODNQLLQ
LPSUHJQLUDQDVVPRORDOLODNRP
Specifications for particular types of winding wires - Part 0-4: General requirements -
Glass-fibre wound resin or varnish impregnated, bare or enamelled rectangular copper
wire
Ta slovenski standard je istoveten z: EN 60317-0-4:2016
ICS:
29.060.10 Žice Wires
77.150.30 Bakreni izdelki Copper products
SIST EN 60317-0-4:2016 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 60317-0-4:2016

---------------------- Page: 2 ----------------------

SIST EN 60317-0-4:2016


EUROPEAN STANDARD EN 60317-0-4

NORME EUROPÉENNE

EUROPÄISCHE NORM
January 2016
ICS 29.060.10 Supersedes EN 60317-0-4:1998
English Version
Specifications for particular types of winding wires - Part 0-4:
General requirements - Glass-fibre wound, resin or varnish
impregnated, bare or enamelled rectangular copper wire
(IEC 60317-0-4:2015)
Spécifications pour types particuliers de fils de bobinage - Technische Lieferbedingungen für bestimmte Typen von
Partie 0-4: Exigences générales - Fil de section Wickeldrähten - Teil 0-4: Allgemeine Anforderungen -
rectangulaire en cuivre nu ou émaillé, guipé de fibres de Flachdrähte aus Kupfer, blank oder lackisoliert und umhüllt
verre imprégnées de vernis ou de résine mit Glasgewebe, imprägniert mit Harz oder Lack
(IEC 60317-0-4:2015) (IEC 60317-0-4:2015)
This European Standard was approved by CENELEC on 2015-11-27. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.


European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2016 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
 Ref. No. EN 60317-0-4:2016 E

---------------------- Page: 3 ----------------------

SIST EN 60317-0-4:2016
EN 60317-0-4:2016
European foreword
The text of document 55/1550/FDIS, future edition 3 of IEC 60317-0-4, prepared by IEC/TC 55
"Winding wires" was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as
EN 60317-0-4:2016.
The following dates are fixed:
(dop) 2016-08-27
• latest date by which the document has to be implemented at
national level by publication of an identical national
standard or by endorsement
(dow) 2018-11-27
• latest date by which the national standards conflicting with
the document have to be withdrawn

This document supersedes EN 60317-0-4:1998.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
Endorsement notice
The text of the International Standard IEC 60317-0-4:2015 was approved by CENELEC as a
European Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:
IEC 60264 NOTE Harmonized in EN 60264 series.
IEC 60317 NOTE Harmonized in EN 60317 series.

2

---------------------- Page: 4 ----------------------

SIST EN 60317-0-4:2016
EN 60317-0-4:2016
Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod),
the relevant EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is
available here: www.cenelec.eu.

Publication Year Title EN/HD Year
IEC 60851 series Winding wires - Test methods EN 60851 series

3

---------------------- Page: 5 ----------------------

SIST EN 60317-0-4:2016

---------------------- Page: 6 ----------------------

SIST EN 60317-0-4:2016



IEC 60317-0-4

®


Edition 3.0 2015-10




INTERNATIONAL



STANDARD




NORME



INTERNATIONALE











Specifications for particular types of winding wires –

Part 0-4: General requirements – Glass-fibre wound, resin or varnish

impregnated, bare or enamelled rectangular copper wire




Spécifications pour types particuliers de fils de bobinage –

Partie 0-4: Exigences générales – Fil de section rectangulaire en cuivre nu ou


émaillé, guipé de fibres de verre imprégnées de vernis ou de résine













INTERNATIONAL

ELECTROTECHNICAL

COMMISSION


COMMISSION

ELECTROTECHNIQUE


INTERNATIONALE




ICS 29.060.10 ISBN 978-2-8322-2975-0



Warning! Make sure that you obtained this publication from an authorized distributor.

Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.

® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale

---------------------- Page: 7 ----------------------

SIST EN 60317-0-4:2016
– 2 – IEC 60317-0-4:2015 © IEC 2015
CONTENTS
FOREWORD . 4
INTRODUCTION . 6
1 Scope . 7
2 Normative references . 7
3 Terms, definitions and general notes on tests and appearance . 7
3.1 Terms and definitions . 7
3.2 General notes . 8
3.2.1 Methods of test . 8
3.2.2 Winding wire . 8
3.3 Appearance . 9
4 Dimensions. 9
4.1 Conductor dimensions . 9
4.2 Tolerance on conductor dimensions . 11
4.3 Rounding of corners . 11
4.4 Increase in dimensions due to the insulation . 11
4.5 Overall dimensions . 13
4.5.1 Nominal overall dimensions . 13
4.5.2 Minimum overall dimensions . 13
4.5.3 Maximum overall dimensions . 13
5 Electrical resistance . 13
6 Elongation . 13
7 Springiness . 13
8 Flexibility and adherence . 14
8.1 Mandrel winding test . 14
8.2 Adherence test . 14
8.2.1 Glass-fibre covered bare wires . 14
8.2.2 Glass-fibre covered enamelled wires . 14
9 Heat shock . 14
10 Cut-through . 14
11 Resistance to abrasion . 14
12 Resistance to solvents . 14
13 Breakdown voltage . 14
14 Continuity of insulation . 15
15 Temperature index . 15
16 Resistance to refrigerants . 15
17 Solderability . 15
18 Heat or solvent bonding . 15
19 Dielectric dissipation factor . 15
20 Resistance to transformer oil . 15
21 Loss of mass . 15
23 Pin hole test . 16
30 Packaging . 16

---------------------- Page: 8 ----------------------

SIST EN 60317-0-4:2016
IEC 60317-0-4:2015 © IEC 2015 – 3 –
Annex A (informative) Nominal cross-sectional areas for preferred and intermediate
sizes . 17
Bibliography . 24

Table 1 – Nominal cross-sectional areas of preferred sizes . 10
Table 2 – Conductor tolerances . 11
Table 3 – Corner radii . 11
Table 4 – Increase in dimensions . 12
Table 5 – Elongation . 13
Table 6 – Mandrel winding . 14
Table 7 – Breakdown voltage . 15
Table A.1 – Nominal cross-sectional areas (1 of 7) . 17

---------------------- Page: 9 ----------------------

SIST EN 60317-0-4:2016
– 4 – IEC 60317-0-4:2015 © IEC 2015
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________

SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES –

Part 0-4: General requirements –
Glass-fibre wound, resin or varnish impregnated,
bare or enamelled rectangular copper wire

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60317-0-4 has been prepared by IEC technical committee 55:
Winding wires.
This third edition cancels and replaces the second edition published in 1997,
Amendment 1:1999 and Amendment 2:2005. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous
edition:
a) addition of dimensional requirements for grade 1 enamelled wire in Table 4;
b) addition of dielectric breakdown requirements for grade 1 enamelled wire in Table 7.

---------------------- Page: 10 ----------------------

SIST EN 60317-0-4:2016
IEC 60317-0-4:2015 © IEC 2015 – 5 –
The text of this standard is based on the following documents:
FDIS Report on voting
55/1550/FDIS 55/1565/RVD

Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all the parts in the IEC 60317 series, published under the general title Specifications
for particular types of winding wires, can be found on the IEC website.
This standard is to be read in conjunction with the IEC 60851 series. The clause numbers
used in this standard are identical with the respective test numbers of the IEC 60851 series.
In case of inconsistencies between IEC 60851 and this standard, the latter prevails.
The numbering of clauses in this standard is not continuous from Clauses 21 through 30 in
order to reserve space for possible future wire requirements prior to those for wire packaging.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC website under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.

---------------------- Page: 11 ----------------------

SIST EN 60317-0-4:2016
– 6 – IEC 60317-0-4:2015 © IEC 2015
INTRODUCTION
This part of IEC 60317 is one of a series which deals with insulated wires used for windings in
electrical equipment. The series has three groups describing:
1) Winding wires – Test methods (IEC 60851);
2) Specifications for particular types of winding wires (IEC 60317);
3) Packaging of winding wires (IEC 60264).

---------------------- Page: 12 ----------------------

SIST EN 60317-0-4:2016
IEC 60317-0-4:2015 © IEC 2015 – 7 –
SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES –

Part 0-4: General requirements –
Glass-fibre wound, resin or varnish impregnated,
bare or enamelled rectangular copper wire



1 Scope
This part of IEC 60317 specifies general requirements of glass-fibre wound, resin or varnish
impregnated, bare or enamelled rectangular copper wire.
The range of nominal conductor dimensions is given in the relevant specification sheet.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60851 (all parts), Winding wires – Test methods
3 Terms, definitions and general notes on tests and appearance
3.1 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1.1
coating
material which is deposited on a conductor or wire by a suitable means and then dried and/or
cured
3.1.2
conductor
bare metal after removal of the insulation
3.1.3
covering
material which is wound, wrapped or braided around a bare or insulated conductor
3.1.4
crack
opening in the insulation which exposes the conductor to view at the stated magnification
3.1.5
enamelled wire
wire coated with an insulation of cured resin
3.1.6
grade
range of thickness of the insulation of a wire

---------------------- Page: 13 ----------------------

SIST EN 60317-0-4:2016
– 8 – IEC 60317-0-4:2015 © IEC 2015
3.1.7
insulation
coating or covering on the conductor with the specific function of withstanding voltage
3.1.8
nominal conductor dimension
designation of the conductor size in accordance with IEC 60317
3.1.9
normal vision
20/20 vision, with corrective lenses if necessary
3.1.10
winding wire
wire used for winding a coil to provide a magnetic field
3.1.11
wire
conductor coated or covered with an insulation
3.2 General notes
3.2.1 Methods of test
All methods of test to be used for this part of IEC 60317 are given in the IEC 60851 series of
standards.
The clause numbers used in this part of IEC 60317 are identical with the respective test
numbers in the IEC 60851 series of standards.
In case of inconsistencies between the publication on test methods and this part of
IEC 60317, the latter shall prevail.
Where no specific range of nominal conductor dimensions is given for a test, the test applies
to all nominal conductor dimensions covered by the specification sheet.
Unless otherwise specified, all tests shall be carried out at a temperature from 15 °C to 40 °C
and a relative humidity from 45 % to 75 %. Before measurements are made, the specimens
shall be preconditioned under these atmospheric conditions for a time sufficient to allow the
specimens to reach stability.
The wire to be tested shall be removed from the packaging in such a way that it is not
subjected to tension or unnecessary bends. Before each test, sufficient wire should be
discarded to ensure that any damaged wire is not included in the test specimens.
3.2.2 Winding wire
When reference is made to a winding wire according to a standard of the IEC 60317 series,
the following information is given in the description:
– reference of the IEC specification;
– nominal conductor dimensions in millimetres (width × thickness);
– grade.
EXAMPLE IEC 60317-31 – 4,00 × 1,00 Grade 2GL1

---------------------- Page: 14 ----------------------

SIST EN 60317-0-4:2016
IEC 60317-0-4:2015 © IEC 2015 – 9 –
3.3 Appearance
The fibrous covering shall be essentially smooth and continuous, and free from physical
damage and foreign material when examined with normal vision, as wound on the original
spool or reel.
NOTE Evidence of physical damage includes gashes, broken fibre strands, and the like.
4 Dimensions
4.1 Conductor dimensions
The dimensions for widths and thickness of conductors of winding wires with rectangular
cross-section recommended in this part of IEC 60317 shall be in accordance with Table 1,
and are taken from the R 20 series according to ISO 3.
Preferred and intermediate sizes are combinations of width and thickness both according to
the R 20 series.
This part of IEC 60317 covers:
– widths from 2,00 mm up to and including 16,00 mm;
– thicknesses from 0,80 mm up to and including 5,60 mm.
For thickness over 5,60 mm up to and including 10 mm and for widths over 16 mm up to and
including 25 mm where, for technical reasons, additional sizes may be needed, the R 40
series shall be used. The ratio width/thickness shall be within the specified limits and
combinations of R 40 and R 40 are not allowed in the case of additional sizes.
The ratio width/thickness shall be greater than or equal to 1,4:1 and shall not exceed 8:1.
The actual values of dimensions are given in Table 1.
The nominal cross-sectional areas for preferred sizes are given in Table 1 and the nominal
cross-sectional areas for intermediate sizes are given in Annex A.

---------------------- Page: 15 ----------------------

– 10 – IEC 60317-0-4:2015 © IEC 2015
SIST EN 60317-0-4:2016

Table 1 – Nominal cross-sectional areas of preferred sizes
Thickness
mm 0,80 0,90 1,00 1,12 1,25 1,40 1,60 1,80 2,00 2,24 2,50 2,80 3,15 3,55 4,00 4,50 5,00 5,60
a a a a a
Corner radius (0,5 mm ) Corner radius (0,5 mm ) Corner radius (0,65 mm ) Corner radius (0,80 mm ) Corner radius (1,0 mm )
2,00 1,463 1,626 1,785 2,025 2,285 2,585
2,24 1,655 1,842 2,205 2,294 2,582 2,921 3,369
2,50 1,863 2,076 2,285 2,585 2,910 3,285 3,785 4,137
Not recommended
2,80 2,103 2,346 2,585 2,921 3,285 3,705 4,265 4,677 5,237
Ratio width/thickness smaller than 1,4:1
3,15 2,383 2,661 2,935 3,313 3,723 4,195 4,825 5,307 5,937 6,693
3,55 2,703 3,021 3,335 3,761 4,223 4,755 5,465 6,027 6,737 7,589 8,326
4,00 3,063 3,426 3,785 4,265 4,785 5,385 6,185 6,831 7,637 8,597 9,451 10,65
4,50 3,463 3,876 4,285 4,825 5,410 6,085 6,85 7,737 8,631 9,717 10,70 12,05 13,63
5,00 3,863 4,326 4,785 5,385 6,035 6,785 7,785 8,637 9,637 10,84 12,18 13,45 15,20 17,20
5,60 4,363 4,866 5,385 6,057 6,785 7,625 8,745 9,717 10,84 12,18 13,45 15,13 17,09 19,33 21,54
6,30 4,903 5,496 6,085 6,841 7,660 8,605 9,865 10,98 12,24 13,75 15,20 17,09 19,30 21,82 24,34 27,49
7,10 6,216 6,885 7,737 8,660 9,725 11,15 12,42 13,84 15,54 17,20 19,33 21,82 24,66 27,54 31,09 34,64
8,00  7,785 8,745 9,785 10,99 12,59 14,04 15,64 17,56 19,45 21,85 24,65 27,85 31,14 35,14 39,14 43,94
9,00  9,865 11,04 12,39 14,19 15,84 17,64 19,80 21,95 24,65 27,80 31,40 35,14 39,64 44,14 49,54
10,0   12,29 13,79 15,79 17,64 19,64 22,04 24,45 27,45 30,95 34,95 39,14 44,14 49,14 55,14
11,2   15,47 17,71 19,80 22,04 24,79 27,46 30,81 34,73 39,21 43,94 49,54 55,14 61,86
12,5    19,79 22,14 24,64 27,64 30,70 34,45 38,83 43,83 49,14 55,39 61,64 69,14
Not recommended
Ratio width/thickness over 8:1
14,0    24,84 27,64 31,00 34,45 38,65 43,55 49,15 55,14 62,14 69,14 77,54
16,0     31,64 35,48 39,45 44,25 49,85 56,25 63,14 71,14 79,14 88,74
a
Nominal thickness


Width

---------------------- Page: 16 ----------------------

SIST EN 60317-0-4:2016
IEC 60317-0-4:2015 © IEC 2015 – 11 –
4.2 Tolerance on conductor dimensions
The conductor dimensions shall not differ from the nominal values by more than the tolerance
given in Table 2.
Table 2 – Conductor tolerances
Nominal width or thickness
of the conductor
Tolerance
mm
Up to and mm
Over
including
– 3,15
± 0,030
3,15 6,30 ± 0,050
6,30 12,50 ± 0,070
12,50 16,00 ± 0,100

4.3 Rounding of corners
The arc shall merge smoothly into the flat surfaces of the conductor and the strip shall be free
from sharp, rough and projecting edges. The conductor shall have corner radii complying with
Table 3. The specified radii shall be maintained within ± 25 %.
Table 3 – Corner radii
Nominal thickness
of the conductor
Corner radius
mm
Up to and mm
Over
including
– 1,00 0,5 nominal thickness
a
1,00 1,60 0,50
b
1,60 2,24 0,65
2,24 3,55 0,80
3,55 5,60 1,00
If agreed between purchaser and supplier, the corner radii for wires with a width
greater than 4,8 mm may be:
a
0,5 mm nominal thickness;
b
0,8 mm.

4.4 Increase in dimensions due to the insulation
The increase in width or thickness due to the insulation shall be as specified in Table 4.

---------------------- Page: 17 ----------------------

– 12 – IEC 60317-0-4:2015 © IEC 2015
SIST EN 60317-0-4:2016

Table 4 – Increase in dimensions
Increase in dimensions
mm
Glass-fibre covering over Glass-fibre covering over Glass-fibre covering over
bare conductor grade 1 enamelled wire grade 2 enamelled wire
Nominal
width of the
conductor
mm Single covering Double covering Single covering Double covering Single covering Double covering
(GL1) (GL2) (grade 1 GL1) (grade 1 GL2) (grade 2 GL1) (grade 2 GL2)
Up to
Over and Min. Nom. Max. Min. Nom. Max. Min. Nom. Max. Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.
incl.
– 3,15 0,10 0,14 0,18 0,21 0,27 0,33 0,16 0,23 0,30 0,27 0,36 0,45 0,23 0,29 0,35 0,35 0,42 0,49
3,15 6,30 0,12 0,16 0,20 0,23 0,30 0,37 0,18 0,25 0,32 0,29 0,39 0,49 0,25 0,31 0,37 0,38 0,45 0,52
6,30 12,50 0,14 0,19 0,24 0,27 0,35 0,43 0,20 0,28 0,36 0,33 0,44 0,55 0,27 0,34 0,41 0,43 0,50 0,57
12,50 16,00 0,17 0,23 0,29 0,31 0,39 0,47 0,23 0,32 0,41 0,37 0,48 0,59 0,30 0,38 0,46 0,46 0,54 0,62
The maximum increase in thickness or width due to the insulation may be exceeded, provided the overall thickness or width of the insulated wire does not exceed the sum of
the maximum thickness or width of the bare wire plus the maximum increase in dimension.
NOTE The minimum increases in dimensions apply only to the increase in thickness.

---------------------- Page: 18 ----------------------

SIST EN 60317-0-4:2016
IEC 60317-0-4:2015 © IEC 2015 – 13 –
4.5 Overall dimensions
4.5.1 Nominal overall dimensions
The nominal overall dimensions shall
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.