SIST EN 300 220-2 V1.2.1:2003
(Main)ElectroMagnetic Compatibility and Radio Spectrum Matters (ERM); Short range devices; Technical characteristics and test methods for radio equipment to be used in the 25 MHz to 1 000 MHz frequency range with power levels ranging up to 500 mW; Part 2: Supplementary parameters not intended for regulatory purposes
General Information
- Abstract
Revision and upgrade to EN of I-ETS 300 220 (8/93). Covers a wide range of telecommand, telemetry and generic non-speech applications, such as alarm systems, identification, detection, remote control etc. in the frequency band 25-1000 MHz, including European ISM bands. Additional aspects related to the radio characteristics of equipment to be used in social alarm systems, to ensure adequate reliability for the purposes of CENELEC TC79 standardization in this field.
- Status
- Published
- Publication Date
- 30-Nov-2003
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 01-Dec-2003
- Due Date
- 01-Dec-2003
- Completion Date
- 01-Dec-2003
- Mandate
- T-353
Overview
SIST EN 300 220-2 V1.2.1:2003 defines supplementary technical characteristics and test methods for short range radio devices operating in the 25 MHz to 1,000 MHz frequency range with power levels up to 500 mW. Developed by the Slovenski inštitut za standardizacijo (SIST) in alignment with ETSI, this European standard serves as a supplement to the main regulatory requirements covered in EN 300 220-1. It addresses additional performance and reliability aspects important for applications such as telecommand, telemetry, identification, alarm systems, and remote control devices. The standard is particularly relevant for non-speech, generic short range device (SRD) uses, including social alarm systems to ensure adequate operational reliability as demanded by CENELEC TC79 standardization efforts.
Key Topics
- Technical characteristics: Outlines receiver parameters and supplementary radio characteristics not required for regulatory testing, but important for product development and reliable operation.
- Frequency range and power: Applies to SRDs using radio frequencies between 25 MHz and 1,000 MHz and transmitting at up to 500 mW, with both integral and external antennas.
- Receiver performance: Covers maximum and average usable sensitivity, co-channel rejection, adjacent channel selectivity, spurious response rejection, intermodulation response rejection, and blocking or desensitization.
- Testing methods and measurement: Provides guidance for laboratory testing of receiver and transmitter attributes, referencing established standards such as ETS 300 113 and ETS 300 390.
- Social alarm system requirements: Annex A addresses application-specific parameters for social alarm systems to guarantee minimum effective radiated power and receiver performance in typical domestic environments.
Applications
The guidance offered by SIST EN 300 220-2 V1.2.1:2003 is widely applicable across sectors where short range radio devices are critical. Typical uses include:
- Alarm systems (e.g., social alarms, intrusion detection, fire safety signaling)
- Remote control units for industrial or consumer equipment
- Telemetry and telecommand systems for automated monitoring and control of devices
- Identification and detection systems, including asset tracking and personnel monitoring
- Generic non-speech SRD applications that rely on robust radio communications in residential, commercial, or industrial environments
This standard is particularly valuable where device reliability and performance, beyond mandatory regulatory compliance, are essential-such as in health and safety (e.g., social alarms), building automation, or industrial wireless control.
Related Standards
To ensure comprehensive compliance and optimal performance, SIST EN 300 220-2 V1.2.1:2003 should be used alongside related standards:
- EN 300 220-1: Regulatory requirements for spectrum utilization, forming the basis for short range device compliance in Europe
- ETS 300 113 & ETS 300 390: Technical characteristics and test conditions for radio equipment in land mobile service
- CEPT/ERC Recommendation 70-03: General guidelines for short range device frequency allocations and use in Europe
- EN 50134 series (CENELEC TC79): Specific standards for social alarm systems for vulnerable persons
By referencing these documents, manufacturers and system integrators can ensure their SRD products provide not only regulatory compliance but also the robust performance expected in mission-critical and everyday SRD applications.
Keywords: short range devices, radio equipment, 25 MHz to 1000 MHz, electromagnetic compatibility, SRD technical characteristics, wireless alarm systems, remote control, telemetry, receiver parameters, social alarm reliability, European SRD standard.
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.

Intertek Slovenia
Intertek testing, inspection, and certification services in Slovenia.
LNE (Laboratoire National de Métrologie et d'Essais)
French national laboratory for metrology and testing.
Sponsored listings
Frequently Asked Questions
SIST EN 300 220-2 V1.2.1:2003 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "ElectroMagnetic Compatibility and Radio Spectrum Matters (ERM); Short range devices; Technical characteristics and test methods for radio equipment to be used in the 25 MHz to 1 000 MHz frequency range with power levels ranging up to 500 mW; Part 2: Supplementary parameters not intended for regulatory purposes". This standard covers: Revision and upgrade to EN of I-ETS 300 220 (8/93). Covers a wide range of telecommand, telemetry and generic non-speech applications, such as alarm systems, identification, detection, remote control etc. in the frequency band 25-1000 MHz, including European ISM bands. Additional aspects related to the radio characteristics of equipment to be used in social alarm systems, to ensure adequate reliability for the purposes of CENELEC TC79 standardization in this field.
Revision and upgrade to EN of I-ETS 300 220 (8/93). Covers a wide range of telecommand, telemetry and generic non-speech applications, such as alarm systems, identification, detection, remote control etc. in the frequency band 25-1000 MHz, including European ISM bands. Additional aspects related to the radio characteristics of equipment to be used in social alarm systems, to ensure adequate reliability for the purposes of CENELEC TC79 standardization in this field.
SIST EN 300 220-2 V1.2.1:2003 is classified under the following ICS (International Classification for Standards) categories: 33.060.20 - Receiving and transmitting equipment; 33.100.01 - Electromagnetic compatibility in general. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 300 220-2 V1.2.1:2003 is associated with the following European legislation: Standardization Mandates: T-353. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
SIST EN 300 220-2 V1.2.1:2003 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.UHJXODWLYHElectroMagnetic Compatibility and Radio Spectrum Matters (ERM); Short range devices; Technical characteristics and test methods for radio equipment to be used in the 25 MHz to 1 000 MHz frequency range with power levels ranging up to 500 mW; Part 2: Supplementary parameters not intended for regulatory purposes33.100.01Elektromagnetna združljivost na splošnoElectromagnetic compatibility in general33.060.20Sprejemna in oddajna opremaReceiving and transmitting equipmentICS:Ta slovenski standard je istoveten z:EN 300 220-2 Version 1.2.1SIST EN 300 220-2 V1.2.1:2003en01-december-2003SIST EN 300 220-2 V1.2.1:2003SLOVENSKI
STANDARD
European Telecommunications Standards Institute EN 300 220-2 V1.2.1 (1997-11)European Standard (Telecommunications series)Electromagnetic compatibility andRadio spectrum Matters (ERM);Short range devices;Technical characteristics and test methods for radioequipment to be used in the 25 MHz to 1 000 MHz frequencyrange with power levels ranging up to 500 mW;Part 2: Supplementary parametersnot intended for regulatory purposesSIST EN 300 220-2 V1.2.1:2003
EN 300 220-2 V1.2.1 (1997-11)2ReferenceREN/ERM-RP08-0107-2 (21ci0ioo.PDF)formerly REN/RES-08-0107-2KeywordsRadio, testing, SRDETSI SecretariatPostal addressF-06921 Sophia Antipolis Cedex - FRANCEOffice address650 Route des Lucioles - Sophia AntipolisValbonne - FRANCETel.: +33 4 92 94 42 00
Fax: +33 4 93 65 47 16Siret N° 348 623 562 00017 - NAF 742 CAssociation à but non lucratif enregistrée à laSous-Préfecture de Grasse (06) N° 7803/88X.400c= fr; a=atlas; p=etsi; s=secretariatInternetsecretariat@etsi.frhttp://www.etsi.frCopyright NotificationNo part may be reproduced except as authorized by written permission.The copyright and the foregoing restriction extend to reproduction in all media.© European Telecommunications Standards Institute 1997.All rights reserved.SIST EN 300 220-2 V1.2.1:2003
EN 300 220-2 V1.2.1 (1997-11)3ContentsIntellectual Property Rights.4Foreword.41Scope.52Normative references.53Definitions, symbol and abbreviations.63.1Definitions.63.2Symbol.63.3Abbreviations.64Receiver parameters.74.1Maximum usable sensitivity (conducted).74.1.1Definition.74.1.2Limits.74.2Average usable sensitivity (field strength).74.2.1Definition.74.2.2Limits.74.3Co-channel rejection.84.3.1Definition.84.3.2Limits.84.4Adjacent channel selectivity.84.4.1Definition.84.4.2Limits.84.5Spurious response rejection.94.5.1Definition.94.5.2Limits.94.6Intermodulation response rejection.94.6.1Definition.94.6.2Limits.94.7Blocking or desensitization.94.7.1Definition.94.7.2Limits.9Annex A (normative):Application: Social alarm systems.10A.1General.10A.2Minimum effective radiated power.10A.2.1Definition.10A.2.2Method of measurement.10A.2.3Classification of effective radiated power levels.10A.3Receiver parameters.11History.12SIST EN 300 220-2 V1.2.1:2003
EN 300 220-2 V1.2.1 (1997-11)4Intellectual Property RightsETSI has not been informed of the existence of any Intellectual Property Right (IPR) which could be, or could becomeessential to the present document. However, pursuant to the ETSI Interim IPR Policy, no investigation, including IPRsearches, has been carried out. No guarantee can be given as to the existence of any IPRs which are, or may be, or maybecome, essential to the present document.ForewordThis European Standard (Telecommunications series) has been produced by ETSI Technical CommitteeElectromagnetic compatibility and Radio spectrum matters (ERM).The technical parameters which are relevant to the EMC Directive are listed in annex B.The present document consists of two parts as follows:Part 1:"Parameters intended for regulatory purposes";Part 2:"Supplementary parameters not intended for regulatory purposes".This part specifies supplementary parameters for specific applications not related to effective use of the spectrum.Annex A provides specifications concerning social alarm systems.National transposition datesDate of adoption of this EN:24 October 1997Date of latest announcement of this EN (doa):28 February 1998Date of latest publication of new National Standardor endorsement of this EN (dop/e):31 August 1998Date of withdrawal of any conflicting National Standard (dow):31 August 1998SIST EN 300 220-2 V1.2.1:2003
EN 300 220-2 V1.2.1 (1997-11)51ScopeThe present document covers the minimum characteristics considered necessary for Short Range Devices (SRD) in orderto make the best use of the available frequencies. The term "The present document" refers to EN 300 220-2 only.These parameters specified in this part are not intended to be measured for regulatory purposes. However, they are providedto give guidance to manufacturers and users regarding reasonable reliability of the radio link and performance of thereceiver.The present document contains the technical characteristics for radio equipment referencing relevant CEPT/ERCDecisions and Recommendation CEPT ERC/Recommendation 70-03 [1].The present document does not necessarily include all the characteristics which may be required by a user, nor does itnecessarily represent the optimum performance achievable. It is a product family standard which may be completely orpartially superseded by specific standards covering specific applications.The present document applies to short range devices:-either with a Radio Frequency (RF) output connection and/or with an integral antenna;-for alarms, identification, telecommand, telemetry, etc., applications;-with or without speech;-operating on radio frequencies between 25 MHz and 1 000 MHz, with power levels up to 500 mW, radiated orconducted.The present document covers fixed stations, mobile stations and portable stations. In the present document basicrequirements
...