Thermal insulation products for buildings - Factory made products of expanded cork (ICB) - Specification

This European Standard specifies the requirements for factory made products of expanded cork, which are used for the thermal insulation of buildings. The products are made with granulated cork agglomerated without additional binders and are delivered as boards with or without facings or coatings.
Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards.
Products with a declared thermal resistance lower than 0,25 m2K/W, or a declared thermal conductivity greater than 0,060 W/(mK), at 10 °C, are not covered by this European Standard.

Wärmedämmstoffe für Gebäude - Werkmäßig hergestellte Produkte aus expandiertem Kork (ICB) - Spezifikation

Diese Europäische Norm legt die Anforderungen für werkmäßig hergestellte Produkte aus expandiertem, ohne zusätzliche Bindemittel gebundenem Kork fest, die für die Wärmedämmung von Gebäuden benutzt werden. Die Produkte werden in der Form von Platten mit und ohne Kaschierungen geliefert.
Die in dieser Norm beschriebenen Produkte werden auch in vorgefertigten Wärmedämmsystemen und Mehrschicht Platten angewendet. Die Eigenschaften von Systemen, in die diese Produkte integriert sind, werden nicht behandelt.
Die vorliegende Norm beschreibt die Produkteigenschaften und enthält die Prüfverfahren und Festlegungen für die Konformitätsbewertung, die Kennzeichnung und die Etikettierung.
Diese Norm legt keine Leistungsstufen für eine vorgegebene Eigenschaft fest, die ein Produkt erreichen muss, um für einen bestimmten Anwendungsfall tauglich zu sein. Die für bestimmte Anwendungen benötigten Stufen können Regelwerken oder nicht entgegenstehenden Normen entnommen werden.
Diese Europäische Norm gilt nicht für Produkte, deren Nennwert des Wärmedurchlasswiderstandes niedriger als 0,25 m2K/W oder deren Nennwert der Wärmeleitfähigkeit größer als 0,060 W/(mK) bei 10 °C ist.

Produits isolants thermiques pour le bâtiment - Produits manufacturés en liège expansé (ICB) - Spécification

La présente Norme européenne spécifie les exigences auxquelles doivent satisfaire les produits manufacturés en liège expansé utilisés pour l'isolation thermique des bâtiments. Les produits sont agglomérés sans addition de liants et sont livrés sous forme de panneaux, avec ou sans parements.
Les produits couverts par la présente norme sont également utilisés dans des systèmes d'isolation thermique et dans des panneaux composites préfabriqués ; les performances des systèmes incorporant ces produits ne sont pas définies.
La présente norme décrit les caractéristiques des produits et contient des modes opératoires d'essai, d'évaluation de la conformité, de marquage et d'étiquetage.
La présente norme ne spécifie pas, pour une propriété donnée, le niveau exigé que doit atteindre un produit pour démontrer son aptitude à l'emploi dans une application particulière. Les niveaux requis pour une application donnée figurent dans les réglementations ou normes non conflictuelles.
Les produits dont la résistance thermique déclarée à une température de 10 °C est inférieure à 0,25 m2•K/W ou dont la conductivité thermique déclarée à une température de 10 °C est supérieure à 0,060 W/(m•K) ne relèvent pas du domaine d'application de la présente Norme européenne.

Toplotnoizolacijski proizvodi za stavbe - Proizvodi iz ekspandirane plute (ICB) - Specifikacija

Ta evropski standard določa zahteve za proizvode iz ekspandirane plute, ki se uporabljajo za toplotno izolacijo stavb. Proizvodi so izdelani iz zdrobljene plute, aglomerirane brez dodatnih veziv, in so na voljo v obliki plošč s površinsko prevleko ali lakom ali brez.
Proizvodi iz tega standarda se uporabljajo tudi v predizdelanih sistemih toplotne izolacije in vezanih ploščah; lastnosti sistemov iz teh proizvodov niso opisane.
Ta standard opisuje lastnosti proizvodov ter zajema postopke za preskušanje, vrednotenje skladnosti, označevanje in etiketiranje.
Ta standard ne določa zahtevane ravni določene lastnosti, ki jo mora proizvod doseči, da se dokaže njegova primernost namenu za posamezno vrsto uporabe. Zahtevane ravni za posamezno uporabo so določene v uredbah ali standardih, ki niso v nasprotju s tem standardom.
Proizvodi z deklarirano toplotno upornostjo, nižjo od 0,25 m2K/W, ali deklarirano toplotno prevodnostjo, višjo od 0,060 W/(mK) pri 10 °C, v tem evropskem standardu niso zajeti.

General Information

Status
Published
Publication Date
18-Mar-2015
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
27-Feb-2015
Due Date
04-May-2015
Completion Date
19-Mar-2015

Relations

Buy Standard

Standard
EN 13170:2013+A1:2015
English language
49 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Toplotnoizolacijski proizvodi za stavbe - Proizvodi iz ekspandirane plute (ICB) - SpecifikacijaWärmedämmstoffe für Gebäude - Werkmäßig hergestellte Produkte aus expandiertem Kork (ICB) - SpezifikationProduits isolants thermiques pour le bâtiment - Produits manufacturés en liège expansé (ICB) - SpécificationThermal insulation products for buildings - Factory made products of expanded cork (ICB) - Specification91.100.60Thermal and sound insulating materialsICS:Ta slovenski standard je istoveten z:EN 13170:2012+A1:2015SIST EN 13170:2013+A1:2015en,fr,de01-april-2015SIST EN 13170:2013+A1:2015SLOVENSKI
STANDARDSIST EN 13170:20131DGRPHãþD



SIST EN 13170:2013+A1:2015



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 13170:2012+A1
February 2015 ICS 91.100.60 Supersedes EN 13170:2012English Version
Thermal insulation products for buildings - Factory made products of expanded cork (ICB) - Specification
Produits isolants thermiques pour le bâtiment - Produits manufacturés en liège expansé (ICB) - Spécification
Wärmedämmstoffe für Gebäude - Werkmäßig hergestellte Produkte aus expandiertem Kork (ICB) - Spezifikation This European Standard was approved by CEN on 6 October 2012 and includes Amendment 1 approved by CEN on 15 December 2014.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2015 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13170:2012+A1:2015 ESIST EN 13170:2013+A1:2015



EN 13170:2012+A1:2015 (E) 2 Contents Page Foreword .4 1 Scope .6 2 Normative references .6 3 Terms, definitions, symbols, units and abbreviated terms .8 4 Requirements . 11 5 Test methods . 18 6 Designation code . 21 7 Assessment and Verification of the Constancy of Performance (AVCP) . 22 8 Marking and labelling . 22 Annex A (normative)
Determination of the declared values of thermal resistance and thermal conductivity . 24 Annex B (normative)
!Product type determination" (!PTD") and factory production control (FPC) . 27 Annex C (normative)
Multi layered insulation products (insulation cork board) . 31 Annex D (normative)
Determination of the thermal conductivity in relation to moisture content . 33 Annex E (informative)
Examples for the determination of the declared values of thermal resistance and thermal conductivity for a product or a product group . 35 Annex ZA (informative)
!Clauses of this European Standard addressing the provisions of the EU Construction Products Regulation" . 38 Bibliography . 49
Tables Table 1 — Classes for length tolerances . 12 Table 2 — Classes for width tolerances . 12 Table 3 — Classes for thickness tolerances . 13 Table 4 — Levels for bending strength . 14 Table 5 — Dimensional stability under specified temperature and humidity conditions . 14 Table 6 — Levels for compressive stress at 10 % deformation . 15 Table 7 — Levels for tensile strength perpendicular to faces . 15 Table 8 — Levels for compressibility . 17 Table 9 — Test methods, test specimens and conditions. 20 Table A.1 — Values for k for one sided 90 % tolerance interval with a confidence level of 90 % . 26 Table B.1 — Minimum number of tests for !PTD" and minimum product testing frequencies . 27 Table B.2 — Minimum product testing frequencies for the reaction to fire characteristics . 29 Table E.1 —
............................................................................................................................... 35 Table E.2 — R test results ............................................................................................................................... 36 Table ZA.1 — Relevant clauses for factory made expanded cork and intended use ............................... 38 SIST EN 13170:2013+A1:2015



EN 13170:2012+A1:2015 (E) 3 Table ZA.2 — Systems of AVCP . 40 Table ZA.3.1 — Assignment of AVCP tasks for factory made expanded cork products under system 1 for reaction to fire and system 3 (see Table ZA.2) . 40 Table ZA.3.2 — Assignment of AVCP tasks for factory made expanded cork products under system 3 (see Table ZA.2). 42 Table ZA.3.3 — Assignment of AVCP tasks for factory made expanded cork products under combined system 4 for reaction to fire and system 3 (see Table ZA.2) . 43
Figures Figure D.1 — Example of a graphic representation of “a” . 34 Figure ZA.1 — Example CE marking information of products under AVCP system 1 and system 3" . 48
SIST EN 13170:2013+A1:2015



EN 13170:2012+A1:2015 (E) 4 Foreword This document (EN 13170:2012+A1:2015) has been prepared by Technical Committee CEN/TC 88 “Thermal insulating materials and products”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by August 2015, and conflicting national standards shall be withdrawn at the latest by November 2016. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. This document supersedes !EN 13170:2012". This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). !For relationship with EU Construction Products Regulation (CPR), see informative Annex ZA, which is an integral part of this standard." This document includes Amendment 1 approved by CEN on 2014-12-15. The start and finish of text introduced or altered by amendment is indicated in the text by tags !". Compared with EN 13170:2008, the main changes are: a) better harmonisation between the individual standards of the package (EN 13162 to EN 13171) on definitions, requirements, classes and levels; b) new normative annex on multi-layered products; c) changes on some editorial and technical content and addition of information on some specific items such as for ICB; d) addition of links to EN 15715, Thermal insulation products — Instructions for mounting and fixing for reaction to fire testing — Factory made products; e) changes to Annex ZA. !Amendment 1 modifies EN 13170:2012 identifying those clauses of the standard which are needed for the compliance of the European Standard with the Construction Products Regulation (CPR). This amendment introduces f) an addition to the foreword; g) an addition in 3.2; h) a new subclause 4.3.13; i) modification of Clause 7; j) modification of Clause 8; k) modification of Annex B; SIST EN 13170:2013+A1:2015



EN 13170:2012+A1:2015 (E) 5 l) a new Annex ZA." This standard is one of a series of standards for insulation products used in buildings, but may be used in other areas where appropriate. In pursuance of Resolution BT 20/1993 revised, CEN/TC 88 have proposed defining the standards listed below as a “package” of documents. The package of standards comprises the following group of interrelated standards for the specifications of factory made thermal insulation products, all of which come within the scope of CEN/TC 88: EN 13162, Thermal insulation products for buildings — Factory made mineral wool (MW) products — Specification EN 13163, Thermal insulation products for buildings — Factory made expanded polystyrene (EPS) products — Specification EN 13164, Thermal insulation products for buildings — Factory made extruded polystyrene foam (XPS) products — Specification EN 13165, Thermal insulation products for buildings — Factory made rigid polyurethane foam (PU) products — Specification EN 13166, Thermal insulation products for buildings — Factory made phenolic foam (PF) products — Specification EN 13167, Thermal insulation products for buildings — Factory made cellular glass (CG) products — Specification EN 13168, Thermal insulation products for buildings — Factory made wood wool (WW) products — Specification EN 13169, Thermal insulation products for buildings — Factory made expanded perlite board (EPB) products — Specification EN 13170, Thermal insulation products for buildings — Factory made products of expanded cork (ICB) — Specification EN 13171, Thermal insulation products for buildings — Factory made wood fibre (WF) products — Specification The reductions in energy used and emissions produced during the installed life of insulation products exceeds by far the energy used and emissions made during the production and disposal processes. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. SIST EN 13170:2013+A1:2015



EN 13170:2012+A1:2015 (E) 6 1 Scope This European Standard specifies the requirements for factory made products of expanded cork, which are used for the thermal insulation of buildings. The products are made with granulated cork agglomerated without additional binders and are delivered as boards with or without facings or coatings. Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered. This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling. This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards. Products with a declared thermal resistance lower than 0,25 m2„K/W, or a declared thermal conductivity greater than 0,060 W/(m„K), at 10 °C, are not covered by this European Standard. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 822, Thermal insulating products for building applications — Determination of length and width EN 823, Thermal insulating products for building applications — Determination of thickness EN 824, Thermal insulating products for building applications — Determination of squareness EN 825, Thermal insulating products for building applications — Determination of flatness EN 826, Thermal insulating products for building applications — Determination of compression behaviour EN 1602, Thermal insulating products for building applications — Determination of the apparent density EN 1603, Thermal insulating products for building applications — Determination of dimensional stability under constant normal laboratory conditions (23 °C/ 50 % relative humidity) EN 1604, Thermal insulating products for building applications — Determination of dimensional stability under specified temperature and humidity conditions EN 1605, Thermal insulating products for building applications — Determination of deformation under specified compressive load and temperature conditions EN 1606, Thermal insulating products for building applications — Determination of compressive creep EN 1607, Thermal insulating products for building applications — Determination of tensile strength perpendicular to faces EN 1609, Thermal insulating products for building applications — Determination of short term water absorption by partial immersion EN 12086, Thermal insulating products for building applications — Determination of water vapour transmission properties SIST EN 13170:2013+A1:2015



EN 13170:2012+A1:2015 (E) 7 EN 12089, Thermal insulating products for building applications — Determination of bending behaviour EN 12090, Thermal insulating products for building applications — Determination of shear behaviour EN 12105, Resilient floor coverings — Determination of moisture content of agglomerated composition cork EN 12430, Thermal insulating products for building applications — Determination of behaviour under point load EN 12431, Thermal insulating products for building applications — Determination of thickness for floating floor insulation products EN 12667, Thermal performance of building materials and products — Determination of thermal resistance by means of guarded hot plate and heat flow meter methods — Products of high and medium thermal resistance EN 12939, Thermal performance of building materials and products — Determination of thermal resistance by means of guarded hot plate and heat flow meter methods — Thick products of high and medium thermal resistance EN 13172:2012, Thermal insulation products — Evaluation of conformity EN 13501-1, Fire classification of construction products and building elements — Part 1: Classification using data from reaction to fire test EN 13820, Thermal insulating materials for building applications — Determination of organic content EN 13823, Reaction to fire test for building products — Building products excluding floorings exposed to the thermal attack by a single burning item EN 15715:2009, Thermal insulation products — Instructions for mounting and fixing for reaction to fire testing - Factory made products EN 29052-1, Acoustics — Determination of dynamic stiffness — Part 1: Materials used under floating floors in dwellings (ISO 9052-1) EN 29053, Acoustics — Materials for acoustical applications — Determination of air flow resistance (ISO 9053) EN ISO 354, Acoustics — Measurement of sound absorption in a reverberation room (ISO 354) EN ISO 1182, Reaction to fire tests for building products — Non-combustibility test (ISO 1182) EN ISO 1716, Reaction to fire tests for products — Determination of the gross heat of combustion (calorific value) (ISO 1716) EN ISO 9229:2007, Thermal insulation — Vocabulary (ISO 9229:2007) EN ISO 10456, Building materials and products — Hygrothermal properties — Tabulated design values and procedures for determining declared and design thermal values (ISO 10456) EN ISO 11654, Acoustics — Sound absorbers for use in buildings — Rating of sound absorption (ISO 11654) EN ISO 11925-2, Reaction to fire tests — Ignitability of building products subjected to direct impingement of flame — Part 2: Single-flame source test (ISO 11925-2) ISO 16269-6:2005, Statistical interpretation of data — Part 6: Determination of statistical tolerance intervals SIST EN 13170:2013+A1:2015



EN 13170:2012+A1:2015 (E) 8 3 Terms, definitions, symbols, units and abbreviated terms 3.1 Terms and definitions For the purposes of this document, the terms and definitions given in EN ISO 9229:2007 apply with exception or in addition of the following: 3.1.1 cork protective layer of the cork oak tree (Quercus suber L.) which may be periodically removed from its trunk and branches to provide the raw material for cork products 3.1.2 granulated cork fragments of cork obtained by grinding and/or milling raw or manufactured cork Note 1 to entry: Usually, the size of granules is between 4 mm and 18 mm. 3.1.3 insulation cork board (ICB) pre-formed product made from ground granulated cork expanded and bonded exclusively with its own natural binder exuded from cork cell walls by heating under pressure 3.1.4 level value which is the upper or lower limit of a requirement and given by the declared value of the characteristic concerned 3.1.5 class combination of two levels of the same property between which the performance shall fall 3.1.6 board; slab rigid or semi-rigid (insulation) product of rectangular shape and cross section in which the thickness is uniform and substantially smaller than the other dimensions Note 1 to entry
Boards are usually thinner than slabs. They may also be supplied in tapered form. 3.1.7 facing functional or decorative surface layer with a thickness of less than 3 mm, e.g. paper, plastic film, fabric or metal foil, which are not considered as separate thermal insulation layers to be added to the thermal resistance of the product 3.1.8 coating functional or decorative surface layers with a thickness of less than 3 mm usually applied by painting, spraying, pouring or trowelling, which are not considered as separate thermal insulation layers to be added to the thermal resistance of the product 3.1.9 composite insulation product product which can be faced or coated made from two or more layers bonded together by chemical or physical adhesion consisting of at least one factory made thermal insulation material layer SIST EN 13170:2013+A1:2015



EN 13170:2012+A1:2015 (E) 9 3.1.10 multi-layered insulation product product which can be faced or coated made from two or more layers of a thermal insulation material from the same European Standard, which are bonded together by chemical or physical adhesion either horizontally and/or vertically 3.2 Symbols, units and abbreviated terms For the purposes of this document, the following symbols and units apply. .p is the practical sound absorption coefficient — .w is the weighted sound absorption coefficient — b is the width mm c is the compressibility mm d is the thickness under a load of (250 ± 5) Pa mm dB is the thickness under a load of 2 kPa after removal of an additional load of 48 kPa mm dL is the thickness under a load of 250 Pa mm dN is the nominal thickness of the product mm dS is the thickness of the test specimen mm û0b is the relative change in width % û0d is the relative change in thickness % û0l is the relative change in length % û0s is the relative change in flatness mm/m 0 is the deformation under specified compressive load and temperature mm 0ct is the compressive creep % 0t is the total relative thickness reduction % Fp is the compressive force at critical point kN H is the moisture content % k is a factor related to the number of test results available — l is the length mm 90/90 is the 90 % fractile with a confidence level of 90 % for the thermal conductivity W/(m„K) D is the declared thermal conductivity W/(m„K) i is one test result of thermal conductivity W/(m„K) mean is the mean thermal conductivity W/(m„K) U is the design thermal conductivity W/(m„K) n is the number of test results — R90/90 is the 90 % fractile with a confidence level of 90 % for the thermal resistance m2„K/W RD is the declared thermal resistance m2„K/W SIST EN 13170:2013+A1:2015



EN 13170:2012+A1:2015 (E) 10 Ri is one test result of thermal resistance m2„K/W Rmean is the mean thermal resistance m2„K/W RU is the design thermal resistance m2„K/W a is the apparent density kg/m3 Sb is the deviation from squareness on length and width mm/m Sd is the deviation from squareness on thickness mm Smax is the deviation from flatness mm X0 is the initial deformation % Xt is the total thickness reduction % Xct Is the compressive creep % sR is the estimate of the standard deviation of the thermal resistance m2„K/W s is the estimate of the standard deviation of the thermal conductivity W/(m„K) s is the dynamic stiffness MN/m3 110 is the compressive stress at 10 % deformation kPa 1b is the bending strength kPa 1c is the declared compressive stress (for compressive creep) kPa 1mt is the tensile strength perpendicular to faces kPa Wp is the short-term water absorption kg/m2 2 is the shear strength kPa Z is the water vapour resistance m2„h„Pa/mg
AFr is the symbol of the declared level of air flow resistivity AP is the symbol of the declared level of practical sound absorption coefficient AW is the symbol of the declared level of weighted sound absorption coefficient CC(i1/i2/y) 1c is the symbol of the declared level for compressive creep CP is the symbol of the declared level for compressibility CS(10) is the symbol of the declared level for compressive stress at 10 % deformation DS(23,90) or DS(70,90) is the symbol of the level for dimensional stability under specified temperature and humidity conditions DS(70,-) is the symbol of the declared value for dimensional stability at specified temperature DLT is the symbol of the declared value for the deformation under specified load and temperature L is the symbol of the declared class for length tolerances MU is the symbol of the declared value for water vapour diffusion resistance factor SIST EN 13170:2013+A1:2015



EN 13170:2012+A1:2015 (E) 11 PL(P) is the symbol of the declared level of point load at the critical point SD SS is the symbol of the declared level for dynamic stiffness is the symbol of the declared value for shear strength Ti is the symbol of the declared class for thickness tolerances TR is the symbol of the declared level for tensile strength perpendicular to faces W is the symbol of the declared class for width tolerances WS is the declared value for short term water absorption Z is the symbol of the declared value for water vapour resistance Abbreviated terms used in this standard: ICB is Expanded (Insulation) Cork Board !PTD is Product Type Determination (previously named ITT for Initial Type Test)" FPC is Factory Production Control RtF is Reaction to Fire !AVCP is Assessment and Verification of Constancy of Performance (previously named attestation of conformity) DoP is Declaration of Performance ThI is Thermal Insulation for Buildings VCP is Verification of Constancy of Performance (previously named evaluation of conformity)" 4 Requirements 4.1 General Product properties shall be assessed in accordance with Clause 5. To comply with this standard, products shall meet the requirements of 4.2 and of 4.3, as appropriate. For multi-layered products additional requirements are given in Annex C. One test result for a product property is the average of the measured values on the number of test specimens given in Table 9. 4.2 For all applications 4.2.1 Thermal resistance and thermal conductivity Thermal resistance and thermal conductivity shall be based upon measurements carried out in accordance with EN 12667 or EN 12939 for thick products and in accordance with 5.3.2 and Annex C. The thermal resistance and thermal conductivity shall be determined in accordance with procedures given in Annex A and declared by the manufacturer according to the following: — the reference mean temperature shall be 10 °C; — the declared values are to be given for a moisture content equal to that of the material when it has reached equilibrium with the air at 23 °C and relative humidity 50 %; — the measured values shall be expressed with three significant figures; SIST EN 13170:2013+A1:2015



EN 13170:2012+A1:2015 (E) 12 — for products of uniform thickness, the thermal resistance, RD, shall always be declared. The thermal conductivity, D, shall be declared where possible. Where appropriate, for products of non-uniform thickness (e.g. for sloped and tapered products), only the thermal conductivity, D, shall be declared; — the declared thermal resistance, RD, and the declared thermal conductivity, D, shall be given as limit values representing at least 90 % of the production, determined with a confidence level of 90 %; —
the statistical value of thermal conductivity, 90/90, shall be rounded upwards to the nearest 0,001 W/(m„K) and declared as D in levels with steps of 0,001 W/(m„K); — the declared thermal resistance, RD, shall be calculated from the nominal thickness, dN, or dL in case of products with declared compressibility (see 4.3.10.3) and the corresponding thermal conductivity, 90/90, unless measured directly; — the statistical value of thermal resistance, R90/90, when calculated from the nominal thickness, dN, or dL in case of products with declared compressibility (see 4.3.10.3) and the corresponding thermal conductivity, 90/90, shall be rounded downwards to the nearest 0,05 m2„K/W, and declared as RD in levels with steps of 0,05 m2„K/W; — the statistical value of thermal resistance R90/90, for those products for which only the thermal resistance is measured directly, shall be rounded downwards to the nearest 0,05 m2„K/W and declared as RD in levels with steps of 0,05 m2„K/W. Examples of determination of declared values of thermal resistance, RD, and thermal conductivity, D, are given in Annex D. NOTE U and RU (design values) may be determined with reference to EN ISO 10456. 4.2.2 Length and width Length, l, and width, b, shall be determined in accordance with EN 822. No test result shall deviate from the nominal values by more than the tolerances given in Table 1 and Table 2 for the declared classes. Table 1 — Classes for length tolerances Class Tolerances mm L1 ± 3 L2 ± 5 Table 2 — Classes for width tolerances Class Tolerances mm W1 ± 2 W2 ± 3 NOTE The commonly linear dimensions of Insulation Cork Board are: Length: 1 000 mm Width: 500 mm SIST EN 13170:2013+A1:2015



EN 13170:2012+A1:2015 (E) 13 4.2.3 Thickness Thickness, d, shall be determined in accordance with EN 823, method B.2, under a pressure of (250 ± 5) Pa. No test result shall deviate from the nominal thickness, dN, by more than the tolerances given in Table 3 for the declared class. Table 3 — Classes for thickness tolerances Class Thickness Tolerances T1 20 mm ≤ d ≤ 50 mm ± 1 mm T2 d > 50 mm ± 2 %, maximum ± 2 mm 4.2.4 Squareness Squareness shall be determined in accordance with EN 824. The deviation from squareness on length and width, Sb, shall not exceed 4 mm/m. The deviation from squareness on thickness, Sd, shall not exceed 2 mm. 4.2.5 Flatness Flatness shall be measured according to EN 825. The deviati
...

Questions, Comments and Discussion