Radiation protection instrumentation - Installed radiation monitors for the detection of radioactive and special nuclear materials at national borders

The scope of this International Standard is to define the performance of installed monitors used for the detection of gamma and neutron radiation emitters contained in objects/ containers or vehicles, general characteristics, mechanical characteristics, environmental requirements, test procedures and documentation. This standard is applicable to installed monitors designed to detect special nuclear and other radioactive materials by their emitted gamma and/or neutron radiation. They are used to monitor vehicles, cargo containers, people, or packages and are typically located at national and international borders, but may be used at any location where there is a need for this type of monitoring. This standard does not apply to hand-held monitors. Information regarding the detection of special nuclear material (SNM) is contained in Annex A. This standard provides the purchaser with information that may be used to determine the performance of the monitor in detecting the presence of radioactive sources. This standard does not provide the data needed to determine the performance of the monitor in measuring the quantity of the radioactive material. In this standard, the term radioactive material includes both special nuclear and radioactive material unless otherwise specifically noted. The radioactive material may be transported by vehicle, carried by person, or concealed in a cargo container or in a package moved by conveyor belt, such as international mail parcels. Conformance with the requirements of this standard does not guarantee that a radioactive source will always be discovered. The selection of the location and the configuration of the monitoring system on each site needs to be optimised to achieve the best performance, however, this is outside the scope of this standard.

Strahlenschutz-Messgeräte - Fest installierte Strahlungsmonitore für den Nachweis von radioaktiven Stoffen und spaltbarem Nuklearmaterial an Staatsgrenzen

Instrumentation pour la radioprotection - Moniteurs de rayonnement installés pour la détection des matériaux nucléaires radioactifs et spéciaux aux frontières nationales

Définit les performances des moniteurs installés pour la détection des émetteurs de rayonnements gamma et neutronique contenus dans des objets/conteneurs ou des véhicules, des caractéristiques générales, des caractéristiques mécaniques, des exigences d'environnement, des procédures d'essai et de la documentation. Ces moniteurs sont utilisés pour surveiller des véhicules, des containers de cargo, des personnes ou des colis et ils sont le plus souvent situés aux frontières nationales et internationales, mais ils peuvent être situés partout où il y a un besoin de ce type de surveillance.

Oprema za zaščito pred sevanjem - Vgrajeni monitorji sevanja za odkrivanje radioaktivnih in posebnih nuklearnih materialov na državnih mejah

Namen tega mednarodnega standarda je opredeliti delovanje vgrajenih monitorjev, ki se uporabljajo za odkrivanje materialov, ki oddajajo sevanje gama in nevtronsko sevanje in se nahajajo v predmetih/zabojnikih ali vozilih, splošne značilnosti, mehanske značilnosti, okoljske zahteve, preskusne postopke in dokumentacijo. Ta standard velja za vgrajene monitorje, namenjene odkrivanju posebnih jedrskih in drugih radioaktivnih materialov, ki oddajajo sevanje gama in/ali nevtronsko sevanje. Uporabljajo se za nadzor vozil, tovornih zabojnikov, ljudi ali paketov in so praviloma nameščeni na nacionalnih in mednarodnih mejah, lahko pa se uporabljajo na vseh krajih, kjer obstaja potreba po tovrstnem nadzoru. Ta standard ne velja za ročne monitorje. Informacije v zvezi z odkrivanjem posebnega jedrskega materiala (SNM) so navedene v dodatku A. Ta standard kupcu zagotavlja informacije, ki se lahko uporabijo za ugotavljanje učinkovitosti monitorja pri odkrivanju prisotnosti radioaktivnih virov. Ta standard ne zagotavlja podatkov, potrebnih za ugotavljanje učinkovitosti monitorja pri merjenju količine radioaktivnega materiala. V tem standardu izraz radioaktivni material vključuje posebni jedrski in radioaktivni material, razen če ni posebej navedeno drugače. Radioaktivni material se lahko prevaža z vozilom, lahko ga pri sebi nosi človek, lahko pa se skrije v tovorni zabojnik ali paket, ki se premika po transportnem traku, na primer paket mednarodne pošte. Skladnost z zahtevami tega standarda ne zagotavlja, da bo radioaktivni vir vedno odkrit. Izbiro kraja in konfiguracije nadzornega sistema na vsakem mestu je treba optimizirati, da se doseže optimalni učinek, vendar pa je to zunaj okvira uporabe tega standarda.

General Information

Status
Published
Publication Date
13-Sep-2011
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
23-Aug-2011
Due Date
28-Oct-2011
Completion Date
14-Sep-2011

RELATIONS

Buy Standard

Standard
SIST EN 62244:2011
English language
35 pages
sale 10% off
Preview
sale 10% off
Preview

e-Library read for
1 day

Standards Content (sample)

SLOVENSKI STANDARD
SIST EN 62244:2011
01-oktober-2011
2SUHPD]D]DãþLWRSUHGVHYDQMHP9JUDMHQLPRQLWRUMLVHYDQMD]DRGNULYDQMH
UDGLRDNWLYQLKLQSRVHEQLKQXNOHDUQLKPDWHULDORYQDGUåDYQLKPHMDK

Radiation protection instrumentation - Installed radiation monitors for the detection of

radioactive and special nuclear materials at national borders

Strahlenschutz-Messgeräte - Fest installierte Strahlungsmonitore für den Nachweis von

radioaktiven Stoffen und spaltbarem Nuklearmaterial an Staatsgrenzen

Instrumentation pour la radioprotection - Moniteurs de rayonnement installés pour la

détection des matériaux nucléaires radioactifs et spéciaux aux frontières nationales

Ta slovenski standard je istoveten z: EN 62244:2011
ICS:
13.280 Varstvo pred sevanjem Radiation protection
SIST EN 62244:2011 en

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST EN 62244:2011
---------------------- Page: 2 ----------------------
SIST EN 62244:2011
EUROPEAN STANDARD
EN 62244
NORME EUROPÉENNE
July 2011
EUROPÄISCHE NORM
ICS 13.280
English version
Radiation protection instrumentation -
Installed radiation monitors for the detection of radioactive and special
nuclear materials at national borders
(IEC 62244:2006, modified)
Instrumentation pour la radioprotection - Strahlenschutz-Messgeräte -
Moniteurs de rayonnement installés pour Fest installierte Strahlungsmonitore für
la détection des matériaux nucléaires den Nachweis von radioaktiven Stoffen
radioactifs et spéciaux aux frontières und spaltbarem Nuklearmaterial an
nationales Staatsgrenzen
(CEI 62244:2006, modifiée) (IEC 62244:2006, modifiziert)

This European Standard was approved by CENELEC on 2011-06-27. CENELEC members are bound to comply

with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard

the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on

application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other

language made by translation under the responsibility of a CENELEC member into its own language and notified

to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,

the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,

Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,

Spain, Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Management Centre: Avenue Marnix 17, B - 1000 Brussels

© 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.

Ref. No. EN 62244:2011 E
---------------------- Page: 3 ----------------------
SIST EN 62244:2011
EN 62244:2011 - 2 -
Foreword

The text of the International Standard IEC 62244:2006, prepared by SC 45B, “Radiation protection

instrumentation”, of IEC TC 45, “Nuclear instrumentation”, together with the common modifications prepared

by the Technical Committee CENELEC TC 45B, Radiation protection instrumentation, was submitted to the

CENELEC formal vote and was approved by CENELEC as EN 62244 on 2011-06-27.

Attention is drawn to the possibility that some of the elements of this document may be the subject of patent

rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent rights.

The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2012-06-27
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2014-06-27
Annex ZA has been added by CENELEC.
Subclauses which are additional to those in IEC 62244 are prefixed “Z”.
____________
---------------------- Page: 4 ----------------------
SIST EN 62244:2011
- 3 - EN 62244:2011
Endorsement notice

The text of the International Standard IEC 62244:2006 was approved by CENELEC as a European Standard

with agreed common modifications as given below.
COMMON MODIFICATIONS
3 Terms and definitions
3.1 alarm assembly

Change text to “component that provides audio or visual signals, or both, when an alarm level is

exceeded or a malfunction occurs”.
3.2 detection assembly

Change text to “component of the installed radiation monitor system that contains the detector(s)

and associated electronic devices”.
3.3 detection zone
Insert “being monitored” between “person” and “may”.
3.6 reference point of the detector zone
Delete “that” at start of definition.
Add a new definition
“3.Z1 special nuclear materials

plutonium except that with isotopic concentration exceeding 80 % in plutonium-238; uranium-233;

uranium enriched in the isotope 235 or 233; uranium containing the mixture of isotopes as occurring

in nature other than in the form of ore or ore-residue; any material containing one or more of the

foregoing.
(IAEA-TECDOC-1311)”
4 General Characteristics
4.1 Overview

Replace the last paragraph with “Figure 1 shows an example of the detection zone dimensions for a

monitor that uses two detection assemblies. The following detection zone widths, W, are applicable

to the above four types of monitors.
- pedestrian: Single detector assembly, 1,0 m.
Two detector assemblies, 1,0 m;
- road vehicle: not exceeding 5,0 m;
- rail vehicles: not exceeding 6,0 m;
- conveyor: See 4.5.”.
4.2 Pedestrian
Delete last sentence of paragraph 1.
nd nd
2 paragraph, delete 2 sentence.

Replace last sentence with “For dynamic monitors, the range of passage speeds shall be specified

by the manufacturer, this range shall include 1,2 m/s for pedestrian monitors.”
---------------------- Page: 5 ----------------------
SIST EN 62244:2011
EN 62244:2011 - 4 -
4.3 Road vehicles (includes road transported containers)

Replace last sentence with “For dynamic monitors, the range of passage speeds shall be specified

by the manufacturer, this range shall include 8 km/h for road vehicle monitors.”
4.4 Rail vehicles (includes rail transported containers)

Replace last sentence with “For dynamic monitors, the range of passage speeds shall be specified

by the manufacturer, this range shall include 8 km/h for rail vehicle monitors.”
4.5 Conveyor

Replace last sentence with “For dynamic monitors, the range of passage speeds shall be specified

by the manufacturer, this range shall include 1 m/s for conveyor monitors.”
4.6 Configuration

Replace 2 paragraph with “A detection assembly may consist of a single detector or multiple

detectors contained within a protective cabinet. A monitor may consist of a single detector assembly

or multiple detector assemblies.”
Start the last two paragraphs with “The monitor shall …”.
4.8 Speed control

Replace the section with “The performance of the monitor is dependent on the speed at which the

object being monitored passes through the detection zone. Therefore the monitors, with the

exception of the pedestrian and conveyor monitors, shall include a device for measuring the average

speed of the object passing through the detection zone. An excessive speed alarm shall be provided

that would indicate if the passage speed exceeds the upper speed of the range stated by the

manufacturer. The speed alarm set point shall be adjustable up to a manufacturer-defined maximum

speed.”
5 General test procedures
5.6 Alarm probability for gamma and neutron radiation
Change in line two “detection probability” to “alarm probability”
5.7 Reference radiation
5.7.1 Gamma
First NOTE: Change “NOTE” to “NOTE 1”.
First line of new NOTE 1: Change “0,1 µSv/h” to “0,1 µGy/h”.

Line 3 of third paragraph: After “if not encapsulated” insert “in 0,25 mm stainless steel”.

Last NOTE: Change “NOTE” to “NOTE 2”.
5.7.2 Neutron
252

Replace whole section with “ Cf shall be used for neutron tests. The source should have an activity

-2 -1

that would produce an unscattered neutron fluence rate of 0,04 cm s at the closest point of the

detector. This fluence rate is approximately equivalent to a neutron emission rate of 20 000 s at 2 m

source to detection surface distance.”.
---------------------- Page: 6 ----------------------
SIST EN 62244:2011
- 5 - EN 62244:2011
5.7.3 SNM
Replace heading with “Special nuclear material (SNM)”

Replace whole section with “Standardized SNM test sources given in Annex A may be used by

agreement between manufacturer and user. Test should be performed using the acceptance

requirements given in 6.3 or 6.4 (i.e. 49 successes out of 50 trials).”.
6 Radiation characteristics

Change title to “Radiation characteristics (applicable to all types of monitors)”.

6.1 False alarm test
6.1.1 Requirements

Replace whole section with “No more than one alarm shall occur over a period of 100 h with the

monitor operating in a stable background with a level below the set alarm level.”.

6.1.2 Method of tests

Replace first sentence with “With the monitor operating normally in a stable background initiate a

monitoring cycle as per the manufacturer’s specification at 5 min intervals for a period of 100 h.”.

6.2 Background effects
6.2.1 Requirement

Insert new sentence between first and second paragraph. “The instrument shall alarm when

exposed at 1,5 times the manufacturer’s stated instrument’s maximum background level.”.

6.2.2 Method of tests
Number first paragraph a).
Replace 2 paragraph with the following two paragraphs:

“b) Place the monitor for 100 s in a background level equal to the manufacturer’s stated maximum

background plus 50 %. During this 100 s the monitor shall indicate “non operational”.

c) Place the monitor in a background level equal to the manufacturer’s stated maximum background.

137

Then perform a gamma detection test as stated in step 6.3.2 for Cs only. The monitor shall meet

the requirements given in 6.3.1.”.
6.3 Gamma radiation detection
6.3.2 Method of test

Replace first sentence with “For a dynamic monitor, the source shall be moved through the detection

zone at the passage velocity stated for that particular monitor type, 1,2 m/s for pedestrian monitors,

8 km/h for road and rail vehicle monitors and 1 m/s for conveyor monitors.”.
---------------------- Page: 7 ----------------------
SIST EN 62244:2011
EN 62244:2011 - 6 -
6.4 Neutron radiation detection
6.4.2 Method of test

Change NOTE to “This fluence rate is approximately equivalent to a neutron emission rate of

20 000 s at 2 m source to detection surface distance.”.

Add at the end of second paragraph “, 1,2 m/s for pedestrian monitors, 8 km/h for road and rail

vehicle monitors and 1 m/s for conveyor monitors.”
6.5 Overload characteristics
6.5.2 Method of test
Remove in line 2 “ambient”.
137

Add at the end of this section “This shall be demonstrated using a Cs source with the test method

described in 6.3 but with a reduced number of trials.”.
7 Electrical characteristics
7.1 Mains operation
7.1.2 Method of test
Replace in the first line “defined in 6.3” with “defined in 5.7”.
8 Electromagnetic compatibility
8.1 External magnetic fields
8.1.1 Requirements

Insert at the end of the paragraph “When exposed to external magnetic fields the count rate shall not

vary by more than ± 15 % from the rate under standard test conditions.”.
8.1.2 Method of test
Add at the end of the last sentence “due to the magnetic field.”
8.2 Radiated electromagnetic fields
8.2.2 Method of test

Add at the end of the penultimate sentence “with maximum of ±15 % of count rate change”

Change in the last line “setting” to “status”.
8.3 Conducted disturbances by bursts and radio frequencies
8.3.2 Method of test
Change in test c) “decades” to “order of magnitude”.
Add in the last sentence at the end “due to the conducted disturbances”.
---------------------- Page: 8 ----------------------
SIST EN 62244:2011
- 7 - EN 62244:2011
9 Mechanical characteristics
9.3 Vibration test
9.3.2 Method of test
Add at the end of section a) “(IEC 60068-2-6)”.
9.4 Microphonics/impact
9.4.1 Requirements

Insert between “unaffected” and “by” “(remain within ± 15 % of the pre-test values)”.

9.4.2 Method of test
Delete second paragraph.
10 Environmental characteristics
10.1 Ambient temperature
10.1.2 Method of test
Add at the end of second paragraph “and in 10.1.1”.
10.2 Relative humidity
10.2.2 Method of test
Add in line 5 between ‘Table 3” and “is” “and in 10.2.1”.
10.3 Sealing
10.3.2 Method of test
Change in line 2 “10 l/m” to “10 l/m “.
11 Documentation
11.2 Certificate
Add at the end another bullet “– maximum operational background, see 6.2.1.”.
Table 1 – Reference conditions and standard test conditions

Add a new row below “Reference Gamma radiation source”: “Reference Neutron radiation source”

252
and add in both new columns 2 and 3 “ Cf“.
Table 3 – Tests performed with variations of influence quantities

Add in row 3 (External magnetic fields) in column 3 at the end “by more than ± 15 % of the rate

under standard test conditions”.

Insert in row 8 (Mechanical characteristics) in column 2, “Shock” before first paragraph and

“Vibration” before second paragraph.
Replace in the last row the content of column 2 with “Rain of 10 l/m “.
---------------------- Page: 9 ----------------------
SIST EN 62244:2011
EN 62244:2011 - 8 -
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications

The following referenced documents are indispensable for the application of this document. For dated

references, only the edition cited applies. For undated references, the latest edition of the referenced

document (including any amendments) applies.

NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD

applies.
Publication Year Title EN/HD Year
IEC 60038 - IEC standard voltages EN 60038 -
IEC 60050-393 - International Electrotechnology Vocabulary - - -
Part 393: Nuclear instrumentation - Physical
phenomena and basic concepts
IEC 60050-394 1995 International Electrotechnical Vocabulary - - -
+ A1 1996 Chapter 394: Nuclear instrumentation: - -
+ A2 2000 Instruments - -
IEC 60068-2-18 - Environmental testing - EN 60068-2-18 -
Part 2-18: Tests - Tests R and guidance: Water
IEC 60068-2-27 Environmental testing - EN 60068-2-27 -
Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60068-2-75 - Environmental testing - EN 60068-2-75 -
Part 2-75: Tests - Test Eh: Hammer tests
IEC 60359 - Electrical and electronic measurement EN 60359 -
equipment - Expression of performance
IEC 61000-4-2 - Electromagnetic compatibility (EMC) - EN 61000-4-2 -
Part 4-2: Testing and measurement techniques
- Electrostatic discharge immunity test
IEC 61000-4-3 - Electromagnetic compatibility (EMC) - EN 61000-4-3 -
Part 4-3: Testing and measurement techniques
- Radiated, radio-frequency, electromagnetic
field immunity test
IEC 61000-4-4 - Electromagnetic compatibility (EMC) - EN 61000-4-4 -
Part 4-4: Testing and measurement techniques
- Electrical fast transient/burst immunity test
IEC 61000-4-5 - Electromagnetic compatibility (EMC) - EN 61000-4-5 -
Part 4-5: Testing and measurement techniques
- Surge immunity test
IEC 61000-4-6 - Electromagnetic compatibility (EMC) - EN 61000-4-6 -
Part 4-6: Testing and measurement techniques
- Immunity to conducted disturbances, induced
by radio-frequency fields
IEC 61000-4-12 - Electromagnetic compatibility (EMC) - EN 61000-4-12 -
Part 4-12: Testing and measurement
techniques - Ring wave immunity test
IEC 61187 - Electrical and electronic measuring equipment -EN 61187 -
Documentation
At draft stage.
---------------------- Page: 10 ----------------------
SIST EN 62244:2011
NORME CEI
INTERNATIONALE
IEC
62244
INTERNATIONAL
Première édition
STANDARD
First edition
2006-06
Instrumentation pour la radioprotection –
Moniteurs de rayonnement installés pour la
détection des matériaux nucléaires radioactifs
et spéciaux aux frontières nationales
Radiation protection instrumentation –
Installed radiation monitors for the detection
of radioactive and special nuclear materials
at national borders
 IEC 2006 Droits de reproduction réservés  Copyright - all rights reserved

Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in any

utilisée sous quelque forme que ce soit et par aucun procédé, form or by any means, electronic or mechanical, including

électronique ou mécanique, y compris la photocopie et les photocopying and microfilm, without permission in writing from

microfilms, sans l'accord écrit de l'éditeur. the publisher.

International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland

Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch

CODE PRIX
PRICE CODE
Commission Electrotechnique Internationale
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
Pour prix, voir catalogue en vigueur
For price, see current catalogue
---------------------- Page: 11 ----------------------
SIST EN 62244:2011
62244  IEC:2006 – 3 –
CONTENTS

FOREWORD...........................................................................................................................7

1 Scope and object............................................................................................................11

2 Normative references .....................................................................................................11

3 Terms and definitions .....................................................................................................13

4 General characteristics...................................................................................................17

4.1 Overview ...............................................................................................................17

4.2 Pedestrian.............................................................................................................17

4.3 Road vehicles (includes road transported containers)............................................19

4.4 Rail vehicles (includes rail transported containers) ................................................19

4.5 Conveyor...............................................................................................................19

4.6 Configuration.........................................................................................................19

4.7 Indication features.................................................................................................21

4.8 Speed control........................................................................................................21

5 General test procedures .................................................................................................21

5.1 Nature of tests.......................................................................................................21

5.2 Reference conditions and standard test conditions ................................................23

5.3 Tests performed under standard test conditions ....................................................23

5.4 Tests performed with variation of influence quantities............................................23

5.5 Statistical fluctuations ...........................................................................................23

5.6 Alarm probability for gamma and neutron radiation................................................23

5.7 Reference radiation ...............................................................................................23

6 Radiation characteristics ................................................................................................25

6.1 False alarm test ....................................................................................................25

6.2 Background effects................................................................................................25

6.3 Gamma radiation detection....................................................................................27

6.4 Neutron radiation detection ...................................................................................27

6.5 Overload characteristics ........................................................................................29

7 Electrical characteristics.................................................................................................29

7.1 Mains operation.....................................................................................................29

7.2 Occupancy sensor.................................................................................................31

8 Electromagnetic compatibility .........................................................................................31

8.1 External magnetic fields ........................................................................................31

8.2 Radiated electromagnetic fields.............................................................................31

8.3 Conducted disturbances induced by bursts and radio frequencies .........................33

8.4 Surges and oscillatory waves ................................................................................33

8.5 Electrostatic discharge ..........................................................................................35

9 Mechanical characteristics..............................................................................................37

9.1 Areas of application...............................................................................................37

9.2 Mechanical shocks ................................................................................................37

9.3 Vibration test.........................................................................................................37

9.4 Microphonics/impact..............................................................................................39

---------------------- Page: 12 ----------------------
SIST EN 62244:2011
62244  IEC:2006 – 5 –

10 Environmental characteristics .........................................................................................39

10.1 Ambient temperature .............................................................................................39

10.2 Relative humidity...................................................................................................41

10.3 Sealing..................................................................................................................41

11 Documentation ...............................................................................................................43

11.1 Type test report.....................................................................................................43

11.2 Certificate .............................................................................................................43

11.3 Operation and maintenance manual ......................................................................43

Annex A (informative) Standardized special nuclear materials test sources for type

testing of installed radiation monitors at national borders......................................................51

Figure 1 – Example of a two-sided system ............................................................................49

Table 1 – Reference conditions and standard test conditions ................................................45

Table 2 – Tests performed under standard test conditions ....................................................45

Table 3 – Tests performed with variations of influence quantities..........................................47

Table A.1 – Minimum SNM test sources................................................................................53

---------------------- Page: 13 ----------------------
SIST EN 62244:2011
62244  IEC:2006 – 7 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
RADIATION PROTECTION INSTRUMENTATION –
INSTALLED RADIATION MONITORS FOR THE DETECTION
OF RADIOACTIVE AND SPECIAL NUCLEAR MATERIALS
AT NATIONAL BORDERS
FOREWORD

1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising

all national electrotechnical committees (IEC National Committees). The object of IEC is to promote

international co-operation on all questions concerning standardization in the electrical and electronic fields. To

this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,

Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC

Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested

in the subject dealt with may participate in this preparatory work. International, governmental and non-

governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely

with the International Organization for Standardization (ISO) in accordance with conditions determined by

agreement between the two organizations.

2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international

consensus of opinion on the relevant subjects since each technical committee has representation from all

interested IEC National Committees.

3) IEC Publications have the form of recommendations for international use and are accepted by IEC National

Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC

Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any

misinterpretation by any end user.

4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications

transparently to the maximum extent possible in their national and regional publications. Any divergence

between any IEC and the corresponding national or regional publication shall be clearly indicated in the latter.

5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any

equipment declared to be in conformity with an IEC Publication.

6) All users should ensure that they have the latest edition of this publication.

7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and

members of its technical committees and IEC National Committees for any personal injury, property damage or

other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and

expenses arising out of the publication, use of, or reliance upon, this IEC or any other IEC Publications.

8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is

indispensable for the correct application of this publication.

9) Attention is drawn to the possibility that some of the elements of this IEC may be the subject of patent rights.

IEC shall not be held responsible for identifying any or all such patent rights.

International Standard IEC 62244 has been prepared by subcommittee 45B: Radiation

protection instrumentation, of IEC technical committee 45: Nuclear instrumentation.

The text of this standard is based on the following documents:
FDIS Report on voting
45B/497/FDIS 45B/509/RVD

Full information on the voting for the approval of this standard can be found in the report on

voting indicated in the above table.

This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.

---------------------- Page: 14 ----------------------
SIST EN 62244:2011
62244  IEC:2006 – 9 –

The committee has decided that the contents of this publication will remain unchanged until

the maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in

the data related to the specific publication. At this date, the publication will be

• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
---------------------- Page: 15 ----------------------
SIST EN 62244:2011
62244  IEC:2006 – 11 –
RADIATION PROTECTION INSTRUMENTATION –
INSTALLED RADIATION MONITORS FOR THE DETECTION
OF RADIOACTIVE AND SPECIAL NUCLEAR MATERIALS
AT NATIONAL BORDERS
1 Scope and object

The scope of this International Standard is to define the performance of installed monitors

used for the detection of gamma and neutron radiation emitters contained in objects/

containers or vehicles, general characteristics, mechanical characteristics, environmental

requirements, test procedures and documentation.
This standard is applica
...