SIST EN 12681-1:2027
(Main)Founding - Radiographic testing - Part 1: Film techniques
- Abstract
This document gives specific procedures for industrial X-ray and gamma radiography for discontinuity detection purposes, using NDT (non-destructive testing) film techniques. This part of the EN 12681 series specifies the requirements for film radiographic testing of castings.
Films after exposure and processing become radiographs with different area of optical density. Radiographs are viewed and evaluated using industrial radiographic illuminators.
This part of the EN 12681 series specifies the recommended procedure for the choice of operating conditions and radiographic practice.
These procedures are applicable to castings produced by any casting process, especially for steel, cast iron, aluminium, cobalt, copper, magnesium, nickel, titanium, zinc and any alloys of them.
NOTE This document considers EN ISO 5579.
This document does not apply to:
- radiographic testing of castings for aerospace applications (see EN 2002-21);
- radiographic testing of welded joints (see EN ISO 17636-1);
- radiography with digital detectors (see EN 12681-2);
- radioscopic testing (see the EN 13068 series).
- Status
- Published
- Public Enquiry End Date
- 15-Oct-2025
- Publication Date
- 22-Nov-2026
- Technical Committee
- IFEK - Ferrous metals
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 23-Nov-2026
- Due Date
- 28-Jan-2027
- Completion Date
- 23-Nov-2026
SIST EN 12681-1:2027 is the SIST standard for industrial X-ray and gamma radiography of castings using film techniques. It specifies how to set up the exposure, choose film systems and radiation sources, view the radiographs, and judge discontinuities by image quality and severity levels.
What does SIST EN 12681-1:2027 specify?
SIST EN 12681-1:2027 specifies film radiographic testing of castings for discontinuity detection. It covers the recommended operating conditions and radiographic practice for industrial X-ray and gamma radiography, and it is aimed at castings made by any casting process, especially the listed metal families and their alloys.
The standard uses film exposures that are processed into radiographs and then evaluated with industrial radiographic illuminators. It also notes EN ISO 5579 and excludes aerospace castings, welded joints, digital detector radiography, and radioscopic testing.
The document is organized into 19 clauses plus normative and informative annexes.
| Annex | What it covers |
|---|---|
| Annex A | Minimum image quality values |
| Annex B | Severity levels for steel castings |
| Annex C | Severity levels for cast iron castings |
| Annex D | Severity levels for aluminium alloy and magnesium alloy castings |
| Annex E | Severity levels for copper alloy castings |
| Annex F | Severity levels for titanium and titanium alloy castings |
| Annex G | Significant technical changes from the previous edition |
| Annex H | Calculation of maximum X-ray tube voltages in Figure 13 |
What are the key requirements of SIST EN 12681-1:2027?
SIST EN 12681-1:2027 is built around a practical chain of decisions: choose the testing class, agree the test conditions, select the arrangement and radiation source, verify image quality, and then evaluate the radiograph against severity levels. That sequence matters because each choice affects sensitivity, coverage, and whether the result can be accepted.
1. Choose testing class A or B
Clause 5 divides the techniques into testing class A and testing class B. Class A is the basic option and is recommended unless the order says otherwise; class B is the improved option when class A is not sensitive enough.
In practice, this means the parties need to decide upfront how demanding the inspection must be. If a class B condition cannot be met for technical or industrial reasons, the parties may agree to use the class A condition with compensation through optical density or a better film system, while keeping the other class B conditions.
2. Agree the scope and the conditions before testing
Clause 6 requires agreement on items such as manufacturing stage, extent of testing, test areas, surface condition, class, image quality, marking, acceptance criteria, and any special requirements. It also requires that areas that cannot be radiographed be identified before testing starts.
This is important for complex castings, where some zones may only be partly testable. Clear agreement avoids later disputes over what was inspected and what was not.
3. Use the right test arrangement for the geometry
Clause 7 gives different arrangements for single-wall penetration, double-wall penetration, and complex geometries. The figures in the clause show how to position source, film, and object for plane areas, curved areas, edges, flanges, ribs, wedges, and cross-like shapes.
For double-wall techniques, the standard explains when the method is used as an overview approach and how indications are interpreted in relation to wall thickness. Clause 7 also limits the incident angle in the region of interest, which matters because too much angle can reduce detectability.
4. Select radiation source and energy for the thickness
Clause 8 says the X-ray tube voltage should be as low as possible while still giving the needed penetration. The standard provides thickness-dependent guidance for X-ray sources and gives thickness ranges for gamma sources and higher-energy X-ray equipment.
In practice, energy selection is a trade-off: higher energy helps penetration, but too much energy reduces contrast and sensitivity. For gamma sources, the standard also limits the travel time to and from the source position as part of the exposure time.
5. Match the film system, screens, and scatter control to the task
Clause 9 requires film system classes in accordance with EN ISO 11699-1 and gives minimum film system classes and screen arrangements in tables for different materials, thicknesses, and radiation sources. Clause 10 adds measures to reduce scattered and backscattered radiation, including collimation, lead filtration where relevant, and a lead “B” check for backscatter.
This matters because film choice and scatter control directly affect image contrast and the visibility of small discontinuities. If the backscatter check fails, the radiograph is not acceptable.
6. Control geometry, density, and viewing conditions
Clause 11 sets the source-to-object distance requirements and links them to source size, object-to-film distance, and source geometry. Clause 12 sets minimum optical density values for the evaluated area, and Clause 13 requires controlled processing and viewing in a darkened room with an appropriate illuminator.
In practice, these clauses define whether the image will be sharp enough and bright enough to evaluate. They also require fog checks and viewer limits, so the radiograph can actually be read with confidence.
7. Use image quality indicators and severity levels for acceptance
Clause 16 requires IQI (image quality indicator) use in accordance with EN ISO 19232-1 or EN ISO 19232-2, unless otherwise agreed. Annex A gives the minimum image quality values, and Annex B to Annex F give severity levels and reference radiographs for different casting materials.
This is the acceptance basis for the whole method. The casting conforms only if the observed severity level is equal to or better than the level ordered.
8. Document the result in a test report
Clause 19 requires a test report for each exposure or set of exposures. The report covers the casting, material, stage, technique, source, film, screens, exposure conditions, processing, IQI details, deviations, and the responsible person’s certification and signature.
That record provides traceability for quality control, customer review, and later audits.
What terms does SIST EN 12681-1:2027 define?
- Wall thickness - The thickness measured on the casting itself.
- Nominal wall thickness - The thickness specified on the drawing.
- Penetrated thickness, w - The material thickness in the beam direction, based on the walls actually penetrated by the radiation.
- Source size, d - The size of the radiation source or focal spot.
- Source-to-film distance (SFD) - The distance from the radiation source to the film along the beam direction.
- Optical density, D - The density of the processed radiograph that is used to judge whether the film is readable.
- IQI (image quality indicator) - A device used to verify that the radiograph has the required image quality.
Who uses SIST EN 12681-1:2027?
SIST EN 12681-1:2027 is used by foundries, NDT inspectors, quality managers, and customers who specify radiographic acceptance for cast parts. It is relevant for steel, cast iron, aluminium, cobalt, copper, magnesium, nickel, titanium, zinc, and their alloys.
In practice, users apply it when they need to:
- set radiographic test conditions for castings
- choose film systems, screens, and radiation sources
- evaluate radiographs for internal discontinuities
- define acceptance criteria in contracts or orders
- document test results for traceability and audit purposes
What changed in SIST EN 12681-1:2027 from the previous edition?
SIST EN 12681-1:2027 supersedes EN 12681-1:2017. Annex G lists the main technical changes, including updated ASTM reference radiographs, terminology changes from “class” to “testing class,” revised wording in Clause 7, added figure captions, revised Se 75 thickness rules, added reference to EN IEC 62976, a corrected nomogram and added opening-angle guidance in Clause 11, and the addition of Annex H for X-ray voltage calculation.
Which standards are used with SIST EN 12681-1:2027?
SIST EN 12681-1:2027 relies on several referenced standards for basic rules, equipment, personnel, film, processing, and image quality.
- EN ISO 5579 - Basic rules for radiographic testing of metallic materials using film and X- or gamma rays.
- EN ISO 5580 - Minimum requirements for industrial radiographic illuminators.
- EN ISO 9712 - Qualification and certification of NDT personnel.
- EN ISO 11699-1 - Film system classification for industrial radiography.
- EN ISO 11699-2 - Control of film processing by reference values.
- EN ISO 19232-1 - Wire-type IQI method for image quality value.
- EN ISO 19232-2 - Step/hole-type IQI method for image quality value.
- ISO 5576 - Vocabulary for industrial X-ray and gamma-ray radiology.
- EN 12681-2 - The companion part for digital detector techniques, which this part excludes.
- EN 2002-21 - Radiographic testing of castings for aerospace applications, which this part excludes.
- EN ISO 17636-1 - Radiographic testing of welded joints with film, which this part excludes.
- EN 13068 series - Radioscopic testing, which this part excludes.
What does the SIST EN 12681-1:2027 document contain?
SIST EN 12681-1:2027 contains the full procedure set for film radiography of castings, from preparation and exposure to interpretation and reporting. The main body includes classification of techniques, test arrangements, source selection, film systems, scatter reduction, distance rules, optical density, processing, viewing, image-quality verification, acceptance criteria, and reporting.
It also contains detailed figures for test arrangements and geometry, plus tables for source ranges, film systems, density, and reporting thresholds. Annex A provides minimum IQI values, Annex B to Annex F provide material-specific severity levels, Annex G summarizes changes from the previous edition, and Annex H explains how the maximum X-ray tube voltages in Figure 13 are calculated.
Relations
- Effective Date
- 18-Nov-2026
- Effective Date
- 18-Nov-2026
- Effective Date
- 18-Nov-2026
- Effective Date
- 18-Nov-2026
- Effective Date
- 18-Nov-2026
- Effective Date
- 18-Nov-2026
- Effective Date
- 18-Nov-2026
- Effective Date
- 18-Nov-2026
- Effective Date
- 18-Nov-2026
- Effective Date
- 18-Nov-2026
- Effective Date
- 18-Nov-2026
- Effective Date
- 18-Nov-2026
- Effective Date
- 18-Nov-2026
- Effective Date
- 18-Nov-2026
- Effective Date
- 18-Nov-2026
Get Certified
Connect with accredited certification bodies for this standard

Element Materials Technology
Materials testing and product certification.

Inštitut za kovinske materiale in tehnologije
Institute of Metals and Technology. Materials testing, metallurgical analysis, NDT.
Sponsored listings
Frequently Asked Questions
SIST EN 12681-1:2027 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Founding - Radiographic testing - Part 1: Film techniques". This standard covers: This document gives specific procedures for industrial X-ray and gamma radiography for discontinuity detection purposes, using NDT (non-destructive testing) film techniques. This part of the EN 12681 series specifies the requirements for film radiographic testing of castings. Films after exposure and processing become radiographs with different area of optical density. Radiographs are viewed and evaluated using industrial radiographic illuminators. This part of the EN 12681 series specifies the recommended procedure for the choice of operating conditions and radiographic practice. These procedures are applicable to castings produced by any casting process, especially for steel, cast iron, aluminium, cobalt, copper, magnesium, nickel, titanium, zinc and any alloys of them. NOTE This document considers EN ISO 5579. This document does not apply to: - radiographic testing of castings for aerospace applications (see EN 2002-21); - radiographic testing of welded joints (see EN ISO 17636-1); - radiography with digital detectors (see EN 12681-2); - radioscopic testing (see the EN 13068 series).
This document gives specific procedures for industrial X-ray and gamma radiography for discontinuity detection purposes, using NDT (non-destructive testing) film techniques. This part of the EN 12681 series specifies the requirements for film radiographic testing of castings. Films after exposure and processing become radiographs with different area of optical density. Radiographs are viewed and evaluated using industrial radiographic illuminators. This part of the EN 12681 series specifies the recommended procedure for the choice of operating conditions and radiographic practice. These procedures are applicable to castings produced by any casting process, especially for steel, cast iron, aluminium, cobalt, copper, magnesium, nickel, titanium, zinc and any alloys of them. NOTE This document considers EN ISO 5579. This document does not apply to: - radiographic testing of castings for aerospace applications (see EN 2002-21); - radiographic testing of welded joints (see EN ISO 17636-1); - radiography with digital detectors (see EN 12681-2); - radioscopic testing (see the EN 13068 series).
SIST EN 12681-1:2027 is classified under the following ICS (International Classification for Standards) categories: 77.040.20 - Non-destructive testing of metals. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 12681-1:2027 has the following relationships with other standards: It is inter standard links to SIST EN ISO 14096-2:2020, SIST EN 1559-3:2011, SIST EN 14141:2013, SIST EN 14141:2004, SIST EN 1559-2:2014, SIST EN 1559-4:2015, SIST EN 13068-3:2002, SIST EN 1559-6:1999, SIST EN 1559-5:2017, SIST EN 12392:2016, SIST EN ISO 14096-2:2026, SIST EN 14096-2:2004, SIST EN 13981-3:2006, SIST EN 1559-5:2000, SIST EN 1559-3:2026. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN 12681-1:2027 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-januar-2027
Livarstvo - Radiografsko preskušanje - 1. del: Filmske tehnike
Founding - Radiographic testing - Part 1: Film techniques
Gießereiwesen - Durchstrahlungsprüfung - Teil 1: Filmtechniken
Fonderie - Contrôle par radiographie - Partie 1 : Techniques à l'aide de films
Ta slovenski standard je istoveten z: EN 12681-1:2026
ICS:
77.040.20 Neporušitveno preskušanje Non-destructive testing of
kovin metals
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EN 12681-1
EUROPEAN STANDARD
NORME EUROPÉENNE
November 2026
EUROPÄISCHE NORM
ICS 77.040.20 Supersedes EN 12681-1:2017
English Version
Founding - Radiographic testing - Part 1: Film techniques
Fonderie - Contrôle par radiographie - Partie 1 : Gießereiwesen - Durchstrahlungsprüfung - Teil 1:
Techniques à l'aide de films Filmtechniken
This European Standard was approved by CEN on 11 October 2026.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2026 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 12681-1:2026 E
worldwide for CEN national Members.
Contents Page
European foreword . 4
Introduction . 5
1 Scope . 6
2 Normative references . 6
3 Terms and definitions . 7
4 Symbols and abbreviated terms . 8
5 Classification of radiographic techniques . 8
6 General preparations and requirements . 9
6.1 General preparations . 9
6.1.1 Protection against ionizing radiation . 9
6.1.2 Surface preparation and stage of manufacture . 9
6.2 Agreements . 9
6.3 Personnel qualification . 10
7 Test arrangements . 10
7.1 General. 10
7.2 Single wall penetration of plane areas . 10
7.3 Single wall penetration of curved areas . 10
7.4 Double wall penetration of plane and curved areas . 10
7.5 Choice of test arrangements for complex geometries . 10
7.6 Acceptable test area dimensions . 11
8 Choice of tube potential and radiation source . 17
8.1 X-ray devices up to 1 000 kV . 17
8.2 Other radiation sources . 17
9 Film systems and metal screens . 18
10 Reduction of scattered radiation . 20
10.1 Metal filters and collimators . 20
10.2 Interception of backscattered radiation . 20
11 Source-to-object distance . 20
12 Optical density D of radiograph . 23
13 Film processing and viewing . 24
13.1 Processing. 24
13.2 Film viewing conditions . 24
14 Techniques for increasing the covered thickness range . 24
14.1 General. 24
14.2 Multiple film technique . 25
14.3 Contrast decreasing by higher radiation energy . 26
14.4 Contrast decreasing by beam hardening . 26
14.5 Contrast decreasing by thickness equalization . 27
15 Requirements on radiographs . 27
15.1 Identification of radiograph, test area, film position plan . 27
15.2 Marking of the test areas . 27
15.3 Overlap of films . 27
16 Verification of image quality . 27
17 Influence of crystalline structure . 28
18 Acceptance criteria . 28
18.1 General . 28
18.2 Severity levels . 28
18.3 Wall section zones . 28
19 Test report . 29
Annex A (normative) Minimum image quality values . 31
Annex B (normative) Severity levels for steel castings . 34
Annex C (normative) Severity levels for cast iron castings . 37
Annex D (normative) Severity levels for aluminium alloy and magnesium alloy castings . 40
Annex E (normative) Severity levels for copper alloy castings . 44
Annex F (normative) Severity levels for titanium and titanium alloy castings . 46
Annex G (informative) Calculation of maximum X-ray tube potentials in Figure 13 . 48
Annex H (informative) Significant technical changes between this document and the
previous edition . 49
Bibliography . 50
European foreword
This document (EN 12681-1:2026) has been prepared by Technical Committee CEN/TC 190 “Foundry
technology”, the secretariat of which is held by DIN.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by May 2027, and conflicting national standards shall be
withdrawn at the latest by May 2027.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN 12681-1:2017.
The significant technical changes with respect to EN 12681-1:2017 are given in Annex H (see
Table H.1).
Any feedback and questions on this document should be directed to the users’ national standards body.
A complete listing of these bodies can be found on the CEN website.
According to the CEN-CENELEC Internal Regulations, the national standards organisations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria,
Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland,
Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Republic of
North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and the
United Kingdom.
Introduction
Radiography can be used to detect internal discontinuities in a casting. The discontinuities can be gas
holes, non-metallic inclusions, shrinkage, cracks, inserts or chills or inclusions that have lower or higher
densities than the parent metal. This document gives acceptance criteria through severity levels.
1 Scope
This document gives specific procedures for industrial X-ray and gamma radiography for discontinuity
detection purposes, using NDT (non-destructive testing) film techniques. This part of the EN 12681
series specifies the requirements for film radiographic testing of castings.
Films after exposure and processing become radiographs with different area of optical density.
Radiographs are viewed and evaluated using industrial radiographic illuminators.
This part of the EN 12681 series specifies the recommended procedure for the choice of operating
conditions and radiographic practice.
These procedures are applicable to castings produced by any casting process, especially for steel, cast
iron, aluminium, cobalt, copper, magnesium, nickel, titanium, zinc and any alloys of them.
NOTE This document considers EN ISO 5579.
This document does not apply to:
— radiographic testing of castings for aerospace applications (see EN 2002-21);
— radiographic testing of welded joints (see EN ISO 17636-1);
— radiography with digital detectors (see EN 12681-2);
— radioscopic testing (see the EN 13068 series).
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN ISO 5579:2013, Non-destructive testing — Radiographic testing of metallic materials using film and X-
or gamma rays — Basic rules (ISO 5579:2013)
EN ISO 5580, Non-destructive testing — Industrial radiographic illuminators — Minimum requirements
(ISO 5580)
EN ISO 9712, Non-destructive testing — Qualification and certification of NDT personnel (ISO 9712)
EN ISO 11699-1, Non-destructive testing — Industrial radiographic film — Part 1: Classification of film
systems for industrial radiography (ISO 11699-1)
EN ISO 11699-2, Non-destructive testing — Industrial radiographic films — Part 2: Control of film
processing by means of reference values (ISO 11699-2)
EN ISO 19232-1, Non-destructive testing — Image quality of radiographs — Part 1: Determination of the
image quality value using wire-type image quality indicators (ISO 19232-1)
EN ISO 19232-2, Non-destructive testing — Image quality of radiographs — Part 2: Determination of the
image quality value using step/hole-type image quality indicators (ISO 19232-2)
ISO 5576, Non-destructive testing — Industrial X-ray and gamma-ray radiology — Vocabulary
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 5576, EN ISO 5579 and the
following apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https://www.iso.org/obp
— IEC Electropedia: available at https://www.electropedia.org/
3.1
wall thickness
t
thickness as measured on the casting
3.2
nominal wall thickness
t
n
thickness as specified on the drawing
3.3
penetrated thickness
w
thickness of material in the direction of the radiation beam calculated on the basis of the real
thicknesses of all penetrated walls
3.4
source size
d
size of the radiation source or focal spot size
[SOURCE: EN ISO 5579:2013, 3.4]
3.5
object-to-film distance
b
largest (maximum) distance between the source side of the radiographed part of the test object and the
film surface measured along the central axis of the radiation beam
3.6
source-to-object distance
f
distance between the source of radiation and the source side of the test object, most distant from the
film, measured along the central axis of the radiation beam
3.7
source-to-film distance
SFD
distance between the source of radiation and the film measured in the direction of the beam
Note 1 to entry: SFD = f + b
where
f is the source-to-object distance;
b is the object-to-film distance.
[SOURCE: EN ISO 5579:2013, 3.5, modified – description in words presented as formula]
4 Symbols and abbreviated terms
For the purposes of this document, the symbols and abbreviations apply:
b object-to-film distance
d source size
D optical density of film
f source-to-object distance
F film
IQI image quality indicator
S source of radiation
SFD source-to film-distance
t wall thickness
t nominal wall thickness
n
w penetrated thickness
5 Classification of radiographic techniques
The radiographic techniques are divided into two testing classes:
— Testing class A: basic techniques;
— Testing class B: improved techniques.
It is recommended to perform the testing according to testing class A, if not otherwise specified in the
order. Testing class B techniques are used when testing class A techniques are insufficiently sensitive.
If, for technical or industrial reasons, it is not possible to meet one of the conditions specified for testing
class B, such as the type of radiation source or the source-to-object distance f, it can be agreed by
contracting parties that the condition selected may be what is specified for testing class A. In film
radiography the loss of sensitivity shall be compensated by an increase of minimum optical density to
3,0 or by selection of a two class better film system. The other conditions for testing class B remain
unchanged, especially the image quality achieved. Because of the better sensitivity compared to testing
class A, the specimen may be regarded as being tested to testing class B. This does not apply if the
special SFD reductions as specified in Clause 11 for test arrangements Figure 3 and Figure 4 are used.
6 General preparations and requirements
6.1 General preparations
6.1.1 Protection against ionizing radiation
WARNING — Exposure of any part of the human body to X-rays or gamma-rays can be highly injurious
to health. Wherever X-ray equipment or radioactive sources are in use, appropriate safety requirements
shall be applied.
NOTE Local, national or international safety precautions are especially important to apply when using
ionizing radiation.
6.1.2 Surface preparation and stage of manufacture
In general, surface preparation is not necessary, but where surface imperfections can cause difficulty in
detecting discontinuities, the surface shall be ground smooth.
Unless otherwise specified radiography shall be carried out after the final stage of manufacture, e.g.
after grinding or heat treatment.
NOTE For some aluminium and magnesium alloy castings, radiography can be carried out before heat
treatment.
6.2 Agreements
Castings with a complex geometry can include areas which cannot be tested by radiography or can only
be partly tested. Such areas shall be identified before starting the radiographic testing. Areas which
cannot be tested by radiography shall be noted by all contracting parties and be marked on the film
position plan.
The following items shall be as agreed at the time of order:
a) manufacturing stage at which castings are to be tested;
b) extent of radiographic testing;
c) test areas;
d) surface condition;
e) testing class;
f) information about the film position plan;
g) marking of test areas on the casting;
h) image quality;
i) marking of the radiographs;
j) acceptance criteria;
k) any additional items;
l) any special requirements.
6.3 Personnel qualification
Unless otherwise agreed, testing shall be performed by personnel qualified in accordance with
EN ISO 9712 or equivalent to an appropriate level in the relevant industrial sector.
7 Test arrangements
7.1 General
The test arrangements to be used shall be in accordance with:
Figure 1 to Figure 4: for single wall penetration;
Figure 5 to Figure 7: for double wall penetration;
Figure 8 to Figure 12: for test areas of complex section.
NOTE For an explanation of the symbols in the figures, see Clause 4.
If these arrangements are not applicable, other arrangements may be used.
7.2 Single wall penetration of plane areas
The test arrangement for single wall penetration of plane areas shall be in accordance with Figure 1.
7.3 Single wall penetration of curved areas
The test arrangement for single wall penetration of curved areas shall be in accordance with either
Figure 2, Figure 3 or Figure 4.
NOTE Rigid cassettes can be used if the corresponding increase of b is considered for the calculation of the
distance f between the source and source side of the test object (see Clause 11).
7.4 Double wall penetration of plane and curved areas
The test arrangement for double wall penetration of plane and curved areas shall be in accordance with
either Figure 5, Figure 6 or Figure 7.
In the case of test arrangements according to Figure 5, the distance of the source from the surface of the
test area shall be minimized provided that the requirements of IQI are met.
In the case of test arrangements according to Figure 6 and Figure 7, the discontinuities shall be
classified with reference to the single wall thickness. In the case of different wall thicknesses the
reference shall be the smaller one.
Double wall penetration shall be used, as an overview technique according to Figure 7, if the
geometrical conditions make other test arrangements difficult to apply or if there is a better sensitivity
for detecting discontinuities by using this technique. It shall be ensured that unacceptable
discontinuities are detected with sufficient certainty. The required image quality shall be met.
7.5 Choice of test arrangements for complex geometries
Unless otherwise agreed, the test arrangements for complex geometry areas shall be in accordance with
Figure 8 to Figure 12 (as appropriate).
7.6 Acceptable test area dimensions
The test area to be captured with one radiographic film should be limited in a way that the required
optical density according to Clause 12, Table 4 is met in the region of interest.
In addition to the requirements above, the angle of incident radiation in the entire region of interest
shall not exceed 30°.
NOTE This value can be larger, if special orientations of discontinuities can be detected in this way or if it is
the only way to test areas otherwise impossible to test.
Figure 1 — Test arrangement for single wall penetration of plane areas
a) with flexible cassette
b) with rigid cassette
Figure 2 — Test arrangement for single wall penetration of curved areas with the source on the
convex side and the film on the concave side of the test area
a) with flexible cassette
b) with rigid cassette
Figure 3 — Test arrangement for single wall penetration of curved areas with eccentric
positioning of the source on the concave side and the film on the convex side of the test area
Figure 4 — Test arrangement for single wall penetration of curved areas with central
positioning of the source on the concave side and film on the convex side of the test area
Figure 5 — Test arrangement for double wall penetration of plane or curved test areas; source
and film outside the test area, only the film side wall imaged for evaluation
Figure 6 — Test arrangement for double wall penetration of plane or curved test areas; several
exposures; source and film outside of the test area; both walls imaged for evaluation
Figure 7 — Test arrangement for double wall penetration of plane or curved test areas;
overview exposure; source and film outside of the test area; both walls imaged for evaluation
a) standard arrangement
b) alternative arrangement
b) should only be used if a) is not possible.
Figure 8 — Test arrangements for edges and flanges
a) standard arrangement
b) alternative arrangement
b) should only be used if a) is not possible.
Figure 9 — Test arrangements for ribs
Figure 10 — Test arrangement for cross like geometries
Figure 11 — Test arrangement for wedge geometries
a) for supports
b) for ribs
Figure 12 — Test arrangement for ribs and supports
8 Choice of tube potential and radiation source
8.1 X-ray devices up to 1 000 kV
To maintain good detection sensitivity, the X-ray tube potential (voltage) should be as low as possible.
The maximum values of X-ray tube potential versus thickness are given in Figure 13.
NOTE The calculations for the curves in Figure 13 are described in Annex G.
Key
1 copper/nickel and alloys 4 aluminium and alloys
2 steel and cast irons w penetrated thickness in mm
3 titanium and alloys U X-ray potential in kV
Figure 13 — Maximum X-ray potential U for X-ray devices up to 1 000 kV as a function of
penetrated thickness w and material
For some casting applications where the thickness changes across the area of test object being
radiographed, a modification of technique with a higher potential may be used, but it should be noted
that an excessively high tube potential will lead to a loss of detection sensitivity. If there are different
thicknesses imaged with one exposure, an averaged value of these thicknesses can be used.
8.2 Other radiation sources
The penetrated thickness ranges for gamma ray sources and X-ray potentials higher than 1 MV are
given in Table 1 for steels, cast irons, cobalt, copper and nickel based alloys.
For aluminium, magnesium, titanium and zinc testing using Se 75, the penetrated material thickness is
35 mm ≤ w ≤ 120 mm for testing class A.
Gamma rays from Se 75, Ir 192 and Co 60 sources will not produce radiographs having as good
detection sensitivity as X-rays used with appropriate technique parameters. However, because of the
advantages of gamma ray sources in handling and accessibility, Table 1 gives a range of thicknesses for
which each of these gamma ray sources may be used when the use of X-ray tubes is difficult.
By agreement between the contracting parties, the penetrated material thickness for Ir 192 may be
further reduced to 10 mm.
By agreement between the contracting parties, the penetrated material thickness for Se 75 may be
further reduced for testing class A or testing class B, provided the required image quality as stated in
Clause 16 is achieved. It is recommended that better film system classes are used for testing of
penetrated thicknesses below 10 mm with Se 75 than required in Tables 2 and 3.
For certain applications wider material thickness ranges may be permitted, if sufficient image quality
can be achieved.
For gamma rays, the total travel-time to and from the source position shall not exceed 10 % of the total
exposure time.
Table 1 — Penetrated thickness range for gamma ray sources and X-ray equipment with X-ray
potential above 1 MV for steels, cast irons, cobalt, copper and nickel base alloys
Penetrated thickness
a
w
Radiation source
mm
Testing class A Testing class B
Se 75 10 ≤ w ≤ 40 14 ≤ w ≤ 40
Ir 192 10 ≤ w ≤ 100 20 ≤ w ≤ 90
Co 60 40 ≤ w ≤ 200 60 ≤ w ≤ 150
X-ray potentials from 1 MV up to 4 MV 30 ≤ w ≤ 300 50 ≤ w ≤ 180
b b
X-ray potentials from 4 MV up to 12 MV w ≥ 50 w ≥ 70
b b
X-ray potentials above 12 MV w ≥ 80 w ≥ 100
a
If there are different thicknesses imaged with one exposure, an averaged value of these thicknesses can be
used.
b
The minimum penetrated wall thickness may be reduced by 10 mm in testing class A and by 20 mm in
testing class B, if film system class C1 according to EN ISO 11699-1 is used, provided the IQI requirements
are met.
9 Film systems and metal screens
For radiographic testing, film system classes shall be used in accordance with EN ISO 11699-1.
For different radiation sources, the minimum film system classes are given in Table 2 and Table 3.
When using metal screens good contact between films and screens is required. This shall be achieved
either by using vacuum-packed films or by applying pressure.
Other screen thicknesses may be also used provided the required image quality is achieved.
Table 2 — Film system classes and metal screens for the radiography of steels, cast irons, cobalt,
copper and nickel base alloys
Film system
Penetrated thickness Type and thickness of metal screens
a
class
Radiation source
Testing Testing
w Testing class A Testing class B
class A class B
none or up to 0,03 mm front and back
X-ray potentials ≤ 100 kV
screens of lead
C 3
100 kV < X-ray up to 0,15 mm front and back screens of
all w C 5
potentials ≤ 150 kV lead
150 kV < X-ray 0,02 mm to 0,15 mm front and back
C 4
potentials ≤ 250 kV screens of lead
0,02 mm to 0,2 mm front and back screens
w ≤ 50 mm C 4
of lead
250 kV < X-ray
C 5
b
potentials ≤ 500 kV
0,1 mm to 0,2 mm front screens of lead
w > 50 mm C 5
0,02 mm to 0,2 mm back screens of lead
w ≤ 75 mm C 5 C 4
500 kV < X-ray 0,25 mm to 0,7 mm front and back screens
c
potentials ≤ 1 000 kV of steel or copper
w > 75 mm C 5 C 5
0,02 mm to 0,2 mm front and back screens
Se 75 all w C 5 C 4
of lead
0,1 mm to 0,2 mm
0,02 mm to 0,2 mm
front screens of lead
front screens of lead
Ir 192 all w C 5 C 4 b
0,02 mm to 0,2 mm back screens of lead
w ≤ 100 mm C 4
0,25 mm to 0,7 mm front and back screens
Co 60 C 5
c
of steel or copper
w > 100 mm C 5
w ≤ 100 mm C 3
1 MV < X-ray 0,25 mm to 0,7 mm front and back screens
C 5
c
potentials ≤ 4 MV of steel or copper
w > 100 mm C 5
up to 1 mm front screen of copper, steel or
w ≤ 100 mm C 4 C 2
d
tantalum
4 MV < X-ray
100 mm < w ≤ 300 mm C 4
potentials ≤ 12 MV
back screen of copper or steel up to 1 mm
C 5
d
w > 300 mm C 5
or tantalum up to 0,5 mm
e
w ≤ 100 mm C 4 C 1
up to 1 mm front screen of tantalum
No back screen
X-ray potentials above 100 mm < w ≤ 300 mm C 3
12 MV
C 5
e
up to 1 mm front screen of tantalum up
w > 300 mm C 5
to 0,5 mm back screen of tantalum
a
Better film system classes may also be used according to EN ISO 11699-1.
b
Ready packed films with a front screen up to 0,03 mm may be used if an additional lead screen of 0,1 mm is placed
between the test object and the film.
c
In testing class A also 0,5 mm to 2,0 mm screens of lead may be used.
d
In testing class A lead screens 0,5 mm to 1 mm may be used by agreement between the contracting parties.
e
Tungsten screens may be used by agreement.
Table 3 — X-ray potentials, film system classes and metal screens for aluminium, magnesium,
titanium and zinc
a
Film system class
Type and thickness of intensifying
Radiation source
Testing Testing
screens
class A class B
none or up to 0,03 mm front and up to
X-ray potentials ≤ 150 kV
0,15 mm back screens of lead
0,02 mm to 0,15 mm front and back
150 kV < X-ray potentials ≤ 250 kV C 3
screens of lead
C 5
0,1 mm to 0,2 mm front and back screens
250 kV < X-ray potentials ≤ 500 kV
of lead
b
not 0,2 mm front and 0,1 mm to 0,2 mm back
Se 75
applicable screens of lead
a
Better film system classes may also be used, see EN ISO 11699-1.
b
Instead of one 0,2 mm lead screen, two 0,1 mm lead screens may be used.
10 Reduction of scattered radiation
10.1 Metal filters and collimators
In order to reduce the effect of scattered radiation, direct radiation shall be collimated as much as
possible to the section under examination.
With Se 75, Ir 192 and Co 60 radiation sources or in case of edge scatter a sheet of lead can be used as a
filter of low energy scattered radiation between the test object and the film. The thickness of this sheet
is 0,5 mm to 2 mm in accordance with the penetrated thickness.
10.2 Interception of backscattered radiation
It shall be ensured that the effect of backscattered radiation is minimized.
The presence of backscattered radiation should be checked for each new test arrangement by a lead
letter B (with a minimum height of 10 mm and a minimum thickness of 1,5 mm) placed immediately
behind the cassette. If the image of this symbol records as a lighter image on the radiograph, it shall be
rejected. If the symbol is darker or invisible the radiograph is acceptable and demonstrates good
protection against backscattered radiation.
If necessary, the film shall be shielded from backscattered radiation by an adequate thickness of lead at
least 1 mm, or of tin at least 1,5 mm, placed behind the film-screen combination (or the cassette).
11 Source-to-object distance
The minimum source-to-object distance f depends on the source size or focal spot size d and on the
min
object-to-film distance b. The source size or focal spot size d shall be in accordance with manufacturer’s
values. Values in accordance with the EN ISO 32543 series (for X-ray tubes), EN ISO 32679 (for
isotopes) or EN IEC 62976 (for LINACs) may also be used.
When the source size or focal spot size is specified by two dimensions, the larger shall be used.
For exposure geometries, except for those in Figure 2 b) and Figure 3 b), the distance f shall be chosen
so that the ratio of this distance to the source size d, i.e. f/d, is not below the values given by Formula (1)
and Formula (2):
For testing class A use Formula (1):
23/
f /,d ≥⋅75 b (1)
For testing class B use Formula (2):
23/
f / d ≥⋅15 b (2)
where
b, f, d is given in millimetres (mm).
If the distance b < 1,5 t the dimension b in Formula (1) and Formula (2) and Figure 14 shall be replaced
by the wall thickness t.
For determination of the source-to-object distance f the nomogram in Figure 14 may be used. The
min
nomogram is based on Formula (1) and Formula (2).
For exposure geometries set on the basis of Figure 2 b) and Figure 3 b), the distance f shall be chosen so
that the ratio of this distance to the source size, d, i.e. f/d, is not below the values given by Formula (3)
and Formula (4):
For testing class A use Formula (3):
f b
(3)
≥⋅75,
d
t
For testing class B use Formula (4):
f b
(4)
≥⋅15
d t
where
t is the wall thickness to test, in millimetres (mm);
b is the object-to-film distance, in millimetres (mm).
Key
b object-to-film distance, in mm A testing class A
d source size in mm B testing class B
f minimum source-to-object distance, in mm
min
NOTE This nomogram does not apply for exposure geometries as shown in Figure 2 b) and Figure 3 b).
Figure 14 — Nomogram for the determination of minimum source-to-object distance (f ) in
min
relation to object-to-film distance (b) and the source size (d)
The opening angle 2β of the X-ray tube window and the film size d (diagonal) limit the applicable SFD.
f
Therefore, according to Formula (5), SFD should be:
d
f
SFD ≥ 0,5 ⋅ (5)
tan (β )
The typical opening angle of the X-ray tube window for NDT is 2β = 40° (±20°). Formula (5) is
simplified for these tubes to Formula (6):
(6)
SFD ≥ 1, 4 ⋅ d
f
If the radiation source could be placed inside the test object to be radiographed (techniques shown in
Figure 3 and Figure 4) to achieve a more suitable direction of exposition and when a double wall
technique (see Figure 5 to Figure 7) is avoided this method should be preferred. The reduction in
minimum source-to-object distance should not be greater than 40 %.
When the source is located centrally inside the test object and film outside (technique shown in
Figure 4) and provided that the IQI requirements are met, this percentage may be increased. However,
the reduction in minimum source-to-object distance shall not be greater than 50 %.
12 Optical density D of radiograph
Exposure conditions should be such that the minimum optical density of the radiograph in the area
evaluated is greater than or equal to those given in Table 4.
Table 4 — Optical density of the radiographs
a b
Testing class Optical density (D)
A ≥ 2,0
B ≥ 2,3
a
A measuring tolerance of ±0,1 is permitted.
b
For test areas with different wall thicknesses an optical density > 1,5 for testing class A and > 2,0 for testing
class B is sufficient, if the image quality requirements given in Table A.1 to Table A.3 are met.
High optical densities can be used with advantage where the viewing light is sufficiently bright in
accordance with 13.2. The maximum readable optical density of the film depends on the film viewer
used and its maximum luminance (see EN ISO 5580). The maximum readable optical density shall be
posted on the viewer.
In order to avoid unduly high fog densities arising from film ageing, development or temperature, the
fog density shall be checked periodically on a non-exposed sample taken from the films being used, and
handled and processed under the same conditions as the actual radiograph. The fog density shall not
exceed 0,3. Fog density here is specified as the total optical density (emulsion and base) of a processed,
unexposed film.
If double film viewing is requested the optical density of one single film shall not be lower than 1,3.
13 Film processing and viewing
13.1 Processing
Films are processed in accordance with the conditions recommended by the film and chemical
manufacturer to obtain the selected film system class. Particular attention shall be paid to temperature,
developing time and washing time. The film processing shall be controlled regularly in accordance with
EN ISO 11699-2. The radiographs should be free from defects due to processing or other causes which
would interfere with evaluation.
13.2 Film viewing conditions
The radiographs shall be evaluated in a darkened room on an area of the viewing screen with an
adjustable luminance in accordance with EN ISO 5580. The viewing screen shall be masked to the area
of interest.
14 Techniques for increasing the covered thickness range
14.1 General
In many applications it is useful to image a larger thickness range within one film exposure. Figure 15
provides information on the expected thickness range (difference between maximum penetrated
thickness and minimum penetrated thickness) for steels and cast irons depending on the optical density
ratio in the radiograph. This can be done by one of the following techniques:
— multiple film technique;
— contrast decreasing by higher radiation energy;
— contrast decreasing by beam hardening;
— contrast decreasing by thickness equalization.
Key
X thickness range in millimetres (mm)
Y quotient of optical density Dmax/Dmin for films
Figure 15 — Estimation of possible covered thickness range for different radiation energy levels
for steels and cast irons
14.2 Multiple film technique
For multiple film technique two or more films with different sensitivities are exposed at the same time
(see Figure 16) and viewed singly or together.
Key
D optical density of film
a film system with a higher film system class (higher ISO speed, see EN ISO 11699-1)
b film system with a lower film system class (lower ISO speed, see EN ISO 11699-1)
c lateral dimension
Figure 16 — Arrangement for multiple film technique
There shall be at least one screen between each of the films. When paper backed lead screens are used
for film radiography two screens shall be inserted with the metal layer to the film side. Films and front
and back screens shall be chosen in accordance with Table 2 and Table 3.
Areas on the radiograph with high light intensities shall be masked to avoid dazzle while viewing.
Viewing identification marks (at least 2) shall be imaged to ensure the exact positioning of multiple
films on top of each other. The geometrical features of the casting and of their images on the
radiographs shall correspond.
If double film viewing is used the optical density of a single film (see Clause 12) shall not be less
than 1,3.
14.3 Contrast decreasing by higher radiation energy
For X-ray sources up to 800 kV, the maximum permissible tube potential according to Figure 13 may be
exceeded by max. 30 %. For increasing the covered thickness range, X-ray sources may be replaced by
gamma ray sources or linear accelerators.
The image quality requirement(s) given in Annex A, Table A.1 to Table A.3, shall be met.
14.4 Contrast decreasing by beam hardening
Beam hardening for contrast decreasing is permissible, if the image quality requirement(s) given in
Table A.1 to Table A.3 are met.
14.5 Contrast decreasing by thickness equalization
In radiography imaging different wall thicknesses with one exposure on one radiograph is possible by
covering the area of thinner wall thickness – which is imaged on the radiograph with higher optical
density of the film – with material equalizing the differences in wall thickness, so that the requirements
of optical density of the film according to Clause 12 are met for the whole thickness range.
The equalizing material shall be free from discontinuities and from coarse structure and shall not cause
image disturbance that could harm a good analysis of the test area.
15 Requirements on radiographs
15.1 Identification of radiograph, test area, film position plan
There shall be a clear identification of the test area and of the corresponding radiograph.
For castings which require a large number of radiographs a film position plan or photo documentation
shall be prepared. The position of each film and the corresp
...