SIST EN IEC 60966-4-2:2022
(Main)Radio frequency and coaxial cable assemblies - Part 4-2: Detail specification for semi rigid cable assemblies (jumper) - Frequency range up to 6000 MHz, type 50-9 semi-rigid coaxial cable (IEC 60966-4-2:2022)
Radio frequency and coaxial cable assemblies - Part 4-2: Detail specification for semi rigid cable assemblies (jumper) - Frequency range up to 6000 MHz, type 50-9 semi-rigid coaxial cable (IEC 60966-4-2:2022)
This part of IEC 60966 is a detail specification that relates to semi-rigid cable assemblies
composed of type 50-9 semi-rigid coaxial cables with foamed polyethylene dielectric and
connectors such as type 7-16 (IEC 61169-4), type 4.1-9.5 (IEC 61169-11), type N
(IEC 61169-16), type S7-16 (IEC 61169-53) or type 4.3-10 (IEC 61169-54).
This detail specification applies to the cable assemblies (jumper cables) for mobile
communication, particular for the cable assemblies used between the main feeder and antennas
or between the main feeder and equipment system or between remote radio heads and
antennas. The operating frequency is up to 6 000 MHz.
Hochfrequenz- und Koaxialkabelkonfektionen - Teil 4-2: Bauartspezifikation für halbstarre Kabelkonfektionen (Rangierkabel), Frequenzbereich bis 6 000 MHz, Typ 50-9 halbstarre Koaxialkabel (IEC 60966-4-2:2022)
Cordons coaxiaux et cordons pour fréquences radioélectriques - Partie 4-2: Spécification particulière pour les cordons semi-rigides (jarretières) - Plage de fréquences jusqu'à 6 000 MHz, câble coaxial semi-rigide de type 50-9 (IEC 60966-4-2:2022)
IEC 60966-4-2:2022 est une spécification particulière qui concerne les cordons semi-rigides composés de câbles coaxiaux semi-rigides de type 50-9, avec un diélectrique en polyéthylène expansé et des connecteurs de type 7-16 (IEC 61169-4), de type 4,1-9,5 (IEC 61169‑11), de type N (IEC 61169-16), de type S7-16 (IEC 61169-53) ou de type 4,3-10 (IEC 61169-54).
La présente spécification particulière s’applique aux cordons (câbles de jarretière) pour les communications mobiles, principalement pour les cordons utilisés entre la ligne d'alimentation principale et les antennes, ou entre la ligne d'alimentation principale et le système d'équipement, ou encore entre les têtes radioélectriques distantes et les antennes. La fréquence de fonctionnement s'étend jusqu'à 6 000 MHz.
Sestavi radiofrekvenčnih in koaksialnih kablov - 4-2. del: Podrobna specifikacija za poltoge kabelske sklope (prevezava) - Frekvenčno območje do 6000 MHz, poltogi koaksialni kabel tipa 50-9 (IEC 60966-4-2:2022)
Ta del standarda IEC 60966 je podrobna specifikacija, ki se navezuje na poltoge kabelske sklope, sestavljene iz poltogih koaksialnih kablov tipa 50-9 z dielektrikom iz penastega polietilena in konektorjev tipa 7-16 (IEC 61169-4), tipa 4.1-9.5 (IEC 61169-11), tipa N (IEC 61169-16), tipa S7-16 (IEC 61169-53) ali tipa 4.3-10 (IEC 61169-54). Ta podrobna specifikacija se uporablja za kabelske sklope (prevezovalne kable) za mobilno komunikacijo, zlasti za kabelske sklope, ki se uporabljajo med glavnim dovajalnim vodom in antenami, med glavnim dovajalnim vodom in sistemom opreme oziroma med oddaljenimi radijskimi enotami in antenami. Frekvenčno območje delovanja je do 6000 MHz.
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN IEC 60966-4-2:2022
01-oktober-2022
Sestavi radiofrekvenčnih in koaksialnih kablov - 4-2. del: Podrobna specifikacija za
poltoge kabelske sklope (prevezava) - Frekvenčno območje do 6000 MHz, poltogi
koaksialni kabel tipa 50-9 (IEC 60966-4-2:2022)
Radio frequency and coaxial cable assemblies - Part 4-2: Detail specification for semi
rigid cable assemblies (jumper) - Frequency range up to 6000 MHz, type 50-9 semi-rigid
coaxial cable (IEC 60966-4-2:2022)
Hochfrequenz- und Koaxialkabelkonfektionen - Teil 4-2: Bauartspezifikation für
halbstarre Kabelkonfektionen (Rangierkabel), Frequenzbereich bis 6 000 MHz, Typ 50-9
halbstarre Koaxialkabel (IEC 60966-4-2:2022)
Cordons coaxiaux et cordons pour fréquences radioélectriques - Partie 4-2: Spécification
particulière pour les cordons semi-rigides (jarretières) - Plage de fréquences jusqu'à 6
000 MHz, câble coaxial semi-rigide de type 50-9 (IEC 60966-4-2:2022)
Ta slovenski standard je istoveten z: EN IEC 60966-4-2:2022
ICS:
33.120.10 Koaksialni kabli. Valovodi Coaxial cables. Waveguides
SIST EN IEC 60966-4-2:2022 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN IEC 60966-4-2:2022
---------------------- Page: 2 ----------------------
SIST EN IEC 60966-4-2:2022
EUROPEAN STANDARD EN IEC 60966-4-2
NORME EUROPÉENNE
EUROPÄISCHE NORM August 2022
ICS 33.120.01
English Version
Radio frequency and coaxial cable assemblies - Part 4-2: Detail
specification for semi rigid cable assemblies (jumper) -
Frequency range up to 6000 MHz, type 50-9 semi-rigid coaxial
cable
(IEC 60966-4-2:2022)
Cordons coaxiaux et cordons pour fréquences Hochfrequenz- und Koaxialkabelkonfektionen - Teil 4-2:
radioélectriques - Partie 4-2: Spécification particulière pour Bauartspezifikation für halbstarre Kabelkonfektionen
les cordons semi-rigides (jarretières) - Plage de fréquences (Rangierkabel), Frequenzbereich bis 6 000 MHz, Typ 50-9
jusqu'à 6 000 MHz, câble coaxial semi-rigide de type 50-9 halbstarre Koaxialkabel
(IEC 60966-4-2:2022) (IEC 60966-4-2:2022)
This European Standard was approved by CENELEC on 2022-08-01. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Türkiye and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2022 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN IEC 60966-4-2:2022 E
---------------------- Page: 3 ----------------------
SIST EN IEC 60966-4-2:2022
EN IEC 60966-4-2:2022 (E)
European foreword
The text of document 46/882/FDIS, future edition 1 of IEC 60966-4-2, prepared by IEC/TC 46 "Cables,
wires, waveguides, RF connectors, RF and microwave passive components and accessories" was
submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN IEC 60966-4-2:2022.
The following dates are fixed:
• latest date by which the document has to be implemented at national (dop) 2023-05-01
level by publication of an identical national standard or by endorsement
• latest date by which the national standards conflicting with the (dow) 2025-08-01
document have to be withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
Any feedback and questions on this document should be directed to the users’ national committee. A
complete listing of these bodies can be found on the CENELEC website.
Endorsement notice
The text of the International Standard IEC 60966-4-2:2022 was approved by CENELEC as a
European Standard without any modification.
2
---------------------- Page: 4 ----------------------
SIST EN IEC 60966-4-2:2022
EN IEC 60966-4-2:2022 (E)
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments)
applies.
NOTE 1 Where an International Publication has been modified by common modifications, indicated by (mod),
the relevant EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available
here: www.cenelec.eu.
Publication Year Title EN/HD Year
IEC 60068-2-11 - Environmental testing - Part 2-11: Tests - EN IEC 60068-2-11 -
Test Ka: Salt mist
IEC 60529 - Degrees of protection provided by - -
enclosures (IP Code)
IEC 60966-1 2019 Radio frequency and coaxial cable EN IEC 60966-1 2019
assemblies - Part 1: Generic specification -
General requirements and test methods
IEC 60966-4 - Radio frequency and coaxial cable EN 60966-4 -
assemblies - Part 4: Sectional specification
for semi-rigid coaxial cable assemblies
IEC 60966-4-1 - Radio frequency and coaxial cable EN 60966-4-1 -
assemblies - Part 4-1: Blank detail
specification for semi-rigid coaxial cable
assemblies
IEC 61169-4 - Radio-frequency connectors - Part 4: RF - -
coaxial connectors with inner diameter of
outer conductor 16 mm (0,63 in) with
screw lock - Characteristic impedance
50 Ω; (type 7-16)
IEC 61169-11 - Radio-frequency connectors - Part 11: EN 61169-11 -
Sectional specification for RF coaxial
connectors with inner diameter of outer
conductor 9,5 mm with threaded coupling -
characteristic impedance 50 Ω (Type 4,1-
9,5)
IEC 61169-16 - Radio-frequency connectors - Part 16: EN 61169-16 -
Sectional specification - RF coaxial
connectors with inner diameter of outer
conductor 7 mm (0,276 in) with screw
coupling - Characteristics impedance 50
ohms (75 ohms) (type N)
3
---------------------- Page: 5 ----------------------
SIST EN IEC 60966-4-2:2022
EN IEC 60966-4-2:2022 (E)
Publication Year Title EN/HD Year
IEC 61169-53 - Radio-frequency connectors - Part 53: EN 61169-53 -
Sectional specification for RF coaxial
connectors with inner diameter of outer
conductor 16 mm with screw lock -
Characteristic impedance 50 Ω; (Type S7-
16)
IEC 61169-54 - Radio frequency connectors - Part 54: EN IEC 61169-54 -
Sectional specification for coaxial
connectors with 10 mm inner diameter of
outer conductor, nominal characteristic
impedance 50 Ω, Series 4,3-10
IEC 61196-11 - Coaxial communication cables - Part 11: - -
Sectional specification for semi-rigid cables
with polyethylene (PE) dielectric
4
---------------------- Page: 6 ----------------------
SIST EN IEC 60966-4-2:2022
IEC 60966-4-2
®
Edition 1.0 2022-06
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Radio frequency and coaxial cable assemblies –
Part 4-2: Detail specification for semi-rigid cable assemblies (jumper) –
Frequency range up to 6 000 MHz, type 50-9 semi-rigid coaxial cable
Cordons coaxiaux et cordons pour fréquences radioélectriques –
Partie 4-2: Spécification particulière pour les cordons semi rigides (jarretières) –
Plage de fréquences jusqu'à 6 000 MHz, câble coaxial semi-rigide de type 50-9
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 33.120.01 ISBN 978-2-8322-3891-2
Warning! Make sure that you obtained this publication from an authorized distributor.
Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.
® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale
---------------------- Page: 7 ----------------------
SIST EN IEC 60966-4-2:2022
– 2 – IEC 60966-4-2:2022 © IEC 2022
CONTENTS
FOREWORD . 3
1 Scope . 5
2 Normative references . 5
3 Terms and definitions . 6
4 Detail specification . 7
Annex A (informative) Identification and marking . 12
A.1 Identification . 12
A.2 Marking . 12
Bibliography . 13
Figure 1 – Length definition of cable assemblies . 7
Figure 2 – Semi-rigid cable assemblies with type 50-9 semi-rigid coaxial cable . 7
Table A.1 – The meaning of connector variants . 12
---------------------- Page: 8 ----------------------
SIST EN IEC 60966-4-2:2022
IEC 60966-4-2:2022 © IEC 2022 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES –
Part 4-2: Detail specification for semi-rigid cable assemblies (jumper) –
Frequency range up to 6 000 MHz, type 50-9 semi-rigid coaxial cable
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international
co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and
in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their
preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with
may participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for
Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence between
any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.