Coaxial cables - Part 2-3: Sectional specification for cables used in cabled distribution networks - Distribution and trunk cables for systems operating at 5 MHz - 1 000 MHz

This European Standard relates to EN 50117-1 and should be read in conjunction with this generic specification. This specification applies to distribution and trunk cables for use in cabled distribution systems operating at temperature between -40 °C and +70 °C 1) and at frequencies between 5 MHz and 1 000 MHz and complying with the requirements of EN 50083. The purpose of this European Standard is to specify the applicable test methods and requirements for the electrical, mechanical, environmental and fire performance of the cables.

Koaxialkabel - Teil 2-3: Rahmenspezifikation für Kabel für Kabelverteilanlagen - Verteiler und Linienkabel für Systeme im Bereich von 5 MHz - 1 000 MHz

Câbles coaxiaux - Partie 2-3: Spécification intermédiaire pour câbles utilisés dans les réseaux de distribution câblés - Câbles de distribution et câbles principaux des systèmes fonctionnant à 5 MHz - 1 000 MHz

Koaksialni kabli - 2-3. del: Področna specifikacija za kable v kabelskih razdelilnih omrežjih - Razdelilni in povezovalni kabli za sisteme, ki delujejo v območju 5 MHz do 1.000 MH

Ta evropski standard je povezan s standardom EN 50117-1 in ga je treba brati skupaj s to rodovno specifikacijo. Ta specifikacija velja za razdelilne in kanalne kable v kabelskih razdelilnih sistemih, ki delujejo pri temperaturi med –40 °C in +70 °C 1) in pri frekvencah med 5 MHz in 1 000 MHz ter ustrezajo zahtevam standarda EN 50083. Namen tega evropskega standarda je določiti veljavne preskusne metode in zahteve za električne, mehanske, okoljske in požarne lastnosti kablov.

General Information

Status
Withdrawn
Publication Date
10-Sep-2013
Withdrawal Date
19-Apr-2022
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
20-Apr-2022
Due Date
13-May-2022
Completion Date
20-Apr-2022

Relations

Buy Standard

Amendment
EN 50117-2-3:2005/A2:2013
English language
4 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 50117-2-3:2005/A2:2013
01-oktober-2013
.RDNVLDOQLNDEOLGHO3RGURþQDVSHFLILNDFLMD]DNDEOHYNDEHOVNLKUD]GHOLOQLK
RPUHåMLK5D]GHOLOQLLQSRYH]RYDOQLNDEOL]DVLVWHPHNLGHOXMHMRYREPRþMX0+]
GR0+
Coaxial cables - Part 2-3: Sectional specification for cables used in cabled distribution
networks - Distribution and trunk cables for systems operating at 5 MHz - 1 000 MHz
Koaxialkabel - Teil 2-3: Rahmenspezifikation für Kabel für Kabelverteilanlagen - Verteiler
und Linienkabel für Systeme im Bereich von 5 MHz - 1 000 MHz
Câbles coaxiaux - Partie 2-3: Spécification intermédiaire pour câbles utilisés dans les
réseaux de distribution câblés - Câbles de distribution et câbles principaux des systèmes
fonctionnant à 5 MHz - 1 000 MHz
Ta slovenski standard je istoveten z: EN 50117-2-3:2004/A2:2013
ICS:
33.120.10 Koaksialni kabli. Valovodi Coaxial cables. Waveguides
SIST EN 50117-2-3:2005/A2:2013 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 50117-2-3:2005/A2:2013

---------------------- Page: 2 ----------------------

SIST EN 50117-2-3:2005/A2:2013

EUROPEAN STANDARD
EN 50117-2-3/A2

NORME EUROPÉENNE
August 2013
EUROPÄISCHE NORM

ICS 33.120.10


English version


Coaxial cables -
Part 2-3: Sectional specification for cables used in cabled distribution
networks -
Distribution and trunk cables for systems operating at 5 MHz -
1 000 MHz


Câbles coaxiaux -  Koaxialkabel -
Partie 2-3: Spécification intermédiaire Teil 2-3: Rahmenspezifikation für Kabel
pour câbles utilisés dans les réseaux de für Kabelverteilanlagen -
distribution câblés - Verteiler und Linienkabel für Systeme im
Câbles de distribution et câbles principaux Bereich von 5 MHz -
des systèmes fonctionnant à 5 MHz - 1 000 MHz
1 000 MHz

This amendment A2 modifies the European Standard EN 50117-2-3:2004; it was approved by CENELEC on
2013-07-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this amendment the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the CEN-CENELEC Management Centre or to any CENELEC member.

This amendment exists in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CENELEC member into its own language and notified to the
CEN-CENELEC Management Centre has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cypru
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.