This European Standard defines the test method to be used to determine the air permeability of completely assembled windows and doorsets of any material, when submitted to positive or negative test pressures. This test method is designed to take account of conditions in use, when the window or doorset is installed in accordance with the manufacturer’s specification and the requirements of relevant European Standards and codes of practice.
This European Standard does not apply to the joints between the window or doorset frame and the building construction.
Fenster und Türen - Luftdurchlässigkeit - Prüfverfahren
Diese Europäische Norm legt das Prüfverfahren zur Bestimmung der Luftdurchlässigkeit von vollständig zusammengebauten Fenstern und Türen aller Werkstoffe unter Einwirkung von positiven und negativen Prüfdrücken fest. Die Prüfung erfolgt unter Berücksichtigung der Nutzungs¬bedingungen von Fenstern und Türen, die nach den Festlegungen des Herstellers und den Anforderungen der entsprechenden Europäischen Normen und der Regelwerke der Baupraxis montiert worden sind.
Diese Europäische Norm gilt nicht für die Fugen, die zwischen dem Fenster- bzw. Türrahmen und dem Bauwerk liegen.
Fenêtres et portes - Perméabilité à l'air - Méthode d'essai
La présente Norme européenne définit la méthode à utiliser pour déterminer la perméabilité à l'air de fenêtres et de bloc- portes complètement assemblées quels que soient les matériaux constitutifs, quand elles sont soumises à des pressions d'essai positives et négatives. La présente méthode d'essai est conçue pour tenir compte des conditions en oeuvre quand le bloc-porte ou la fenêtre est installée conformément aux prescriptions du fabricant et aux exigences des normes européennes et des règles de mise en oeuvre pertinentes.
La présente Norme européenne ne s'applique pas aux joints entre le dormant de la fenêtre ou du bloc-porte et la structure du bâtiment.
Okna in vrata - Prepustnost zraka - Preskusna metoda
Ta evropski standard opredeljuje preskusno metodo, ki se uporablja za ugotavljanje prepustnosti zraka v celoti sestavljenih oken in vrat iz katerega koli materiala pri izpostavljenosti pozitivnim ali negativnim preskusnim tlakom. Preskusna metoda je zasnovana tako, da upošteva pogoje uporabe, ko sta okno ali vrata nameščena v skladu s specifikacijami proizvajalca ter zahtevami ustreznih evropskih standardov in pravili ravnanja.
Ta evropski standard se ne uporablja za spoje med okenskim ali vratnim okvirjem in gradbeno konstrukcijo.
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Okna in vrata - Prepustnost zraka - Preskusna metodaFenster und Türen - Luftdurchlässigkeit - PrüfverfahrenFenêtres et portes - Perméabilité à l'air - Méthode d'essaiWindows and doors - Air permeability - Test method91.060.50Vrata in oknaDoors and windowsICS:Ta slovenski standard je istoveten z:EN 1026:2016SIST EN 1026:2016en,fr,de01-maj-2016SIST EN 1026:2016SLOVENSKI
STANDARDSIST EN 1026:20011DGRPHãþD
SIST EN 1026:2016
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 1026
March
t r s x ICS
{ sä r x rä w r Supersedes EN
s r t xã t r r rEnglish Version
Windows and doors æ Air permeability æ Test method Fenêtres et portes æ Perméabilité à l 5air æ Méthode d 5essai
Fenster und Türen æ Luftdurchlässigkeit æ Prüfverfahren This European Standard was approved by CEN on
{ January
t r s xä
egulations which stipulate the conditions for giving this European Standard the status of a national standard without any alterationä Upætoædate lists and bibliographical references concerning such national standards may be obtained on application to the CENæCENELEC Management Centre or to any CEN memberä
translation under the responsibility of a CEN member into its own language and notified to the CENæCENELEC Management Centre has the same status as the official versionsä
CEN members are the national standards bodies of Austriaá Belgiumá Bulgariaá Croatiaá Cyprusá Czech Republicá Denmarká Estoniaá Finlandá Former Yugoslav Republic of Macedoniaá Franceá Germanyá Greeceá Hungaryá Icelandá Irelandá Italyá Latviaá Lithuaniaá Luxembourgá Maltaá Netherlandsá Norwayá Polandá Portugalá Romaniaá Slovakiaá Sloveniaá Spainá Swedená Switzerlandá Turkey andUnited Kingdomä
EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels
9
t r s x CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Membersä Refä Noä EN
s r t xã t r s x ESIST EN 1026:2016
EN 1026:2016 (E) 2 Contents Page European foreword . 3 1 Scope . 5 2 Normative references . 5 3 Terms and definitions . 5 4 Principle of test . 6 5 Test apparatus. 6 6 Preparation of test specimen . 7 7 Test procedure . 7 7.1 Preliminaries . 7 7.2 Air permeability of test chamber . 7 7.2.1 General . 7 7.2.2 Test chamber with known air permeability . 7 7.2.3 Test chamber with unknown air permeability . 7 7.3 Overall air permeability of test specimen and the test chamber – positive pressures . 8 7.3.1 General . 8 7.3.2 Measurement of air permeability for windows and external pedestrian doorsets . 8 7.3.3 Measurement of air permeability for internal pedestrian doorsets . 8 7.4 Overall air permeability of test specimen and the test chamber – negative pressures . 8 8 Test result . 8 9 Test report . 9 Annex A (informative)
Test pressure sequences . 16 Bibliography . 17
SIST EN 1026:2016
EN 1026:2016 (E) 3 European foreword This document (EN 1026:2016) has been prepared by Technical Committee CEN/TC 33 “Doors, windows, shutters, building hardware and curtain walling”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by September 2016, and conflicting national standards shall be withdrawn at the latest by September 2016. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 1026:2000. The revision of this European Standard clarifies the test method and does not affect existing test evidence of EN 1026:2000. In comparison with EN 1026:2000, the following significant changes were made: a) Clause 2: Deletion of "Normative references“; b) Clause 3: Supplement of definition “closing condition”; c) Sub-clause 3.2: Simplification of definition “test pressure”; d) Sub-clause 3.4 and 3.5: Revision of definition „opening joint“; e) Sub-clause 5.4: Revision of definition „accuracy“; f) Sub-clause 7.3: Addition of „closing condition“; g) Sub-clause 7.3: Separate test methods for measurement of air permeability for windows and external pedestrian doorsets in 7.3.2 and for internal pedestrian doorsets in 7.3.3; h) Clause 9: Supplement of necessary description of test specimen; i) Clause 9: Revision of Figures 1 and 2; j) Clause 9: Supplement of figures: - Figure 3 - Sliding door test specimen; - Figure 4 - Single leaf test specimen with fixed glazing; - Figure 5 - Single leaf test specimen with fixed glazing, extension profiles and shutter boxes; - Figure 6 - External / internal pedestrian doorset; k) Revision of Annex A: Separation of figures into Figures A.1 and A.2. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, SIST EN 1026:2016
EN 1026:2016 (E) 4 Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. SIST EN 1026:2016
EN 1026:2016 (E) 5 1 Scope This European Standard defines the test method to be used to determine the air permeability of completely assembled windows and doorsets of any material, when submitted to positive or negative test pressures. This test method is designed to take account of conditions in use, when the window or doorset is installed in accordance with the manufacturer’s specification and the requirements of relevant European Standards and codes of practice. This European Standard does not apply to the joints between the window or door frame and the building construction. 2 Normative references Not applicable. 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 closing condition 3.1.1 closed movable part rest in or at the fixed part in a way in which they may be fastened (latched and/or locked) 3.1.2 fastened where the movable part is restrained at one or more points and shall be described by at least one of the two as listed below: 3.1.2.1 latched movable part is returned to its closed position and restrained by either a) a self - engaging fastener or b) a roller catch or c) a latch 3.1.2.2 locked movable part is further restrained in the closed position by additional operations (of e.g. handle, key, automatic devices or electronic devices) to engage integrated locking devices (e.g. nutbolts or deadbolts) which will affect the product’s characteristics 3.1.3 secured any action(s) which prevent unauthorised release of the fastening device(s) to allow exit or entry (e.g. child safety, burglary) 3.2 test pressure difference between the static air pressures inside and outside of the test chamber SIST EN 1026:2016
EN 1026:2016 (E) 6 Note 1 to entry: The test pressure is positive if the static air pressure inside the chamber of the test apparatus is higher than that outside the test chamber. Note 2 to entry: The test pressure is negative if the static air pressure inside the chamber of the test apparatus is lower than that outside the test chamber. 3.3 air permeability amount of air passing through all joints between casement or leaf and frame profiles of a test specimen caused by the test pressure Note 1 to entry: Air permeability should be expressed in cubic metres per hour (m3/h). 3.4 opening joint line of discontinuity between either a frame and its matched component or two components which can be opened by means of their building hardware (see Figures 1 to 6) Note 1 to entry: Conventionally, this discontinuity is as seen from the opening face of the test specimen. 3.5 length of opening joint length of the line of discontinuity as defined in 3.4 (see Figures 1 to 6) Note 1 to entry: The length of joint should be expressed in metres (m). Note 2 to entry: Actual length of gaskets or seals fitted into the underlying profiles of the components or joints of components built into opening p
...
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Okna in vrata - Prepustnost zraka - Preskusna metodaFenster und Türen - Luftdurchlässigkeit - PrüfverfahrenFenêtres et portes - Perméabilité à l'air - Méthode d'essaiWindows and doors - Air permeability - Test method91.060.50Vrata in oknaDoors and windowsICS:Ta slovenski standard je istoveten z:FprEN 1026kSIST FprEN 1026:2015en,fr,de01-december-2015kSIST FprEN 1026:2015SLOVENSKI
STANDARD
kSIST FprEN 1026:2015
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
FINAL DRAFT
FprEN 1026
October
t r s w ICS
{ sä r x rä w r Will supersede EN
s r t xã t r r rEnglish Version
Windows and doors æ Air permeability æ Test method Fenêtres et portes æ Perméabilité à l 5air æ Méthode d 5essai
Fenster und Türen æ Luftdurchlässigkeit æ Prüfverfahren This draft European Standard is submitted to CEN members for formal voteä It has been drawn up by the Technical Committee
If this draft becomes a European Standardá CEN members are bounwhich stipulate the conditions for giving this European Standard the status of a national standard without any alterationä
This draft European Standard was established by CEN in three ofer language made by translation under the responsibility of a CEN member into its own language and notified to the CENæCENELEC Management Centre has the same status as the official versionsä
CEN members are the national standards bodies of Austriaá Belgiumá Bulgariaá Croatiaá Cyprusá Czech Republicá Denmarká Estoniaá Finlandá Former Yugoslav Republic of Macedoniaá Franceá Germanyá Greeceá Hungaryá Icelandá Irelandá Italyá Latviaá Lithuaniaá Luxembourgá Maltaá Netherlandsá Norwayá Polandá Portugalá Romaniaá Slovakiaá Sloveniaá Spainá Swedená Switzerlandá Turkey and United Kingdomä
Recipients of this draft are invited to submitá with their commentsá notification of any relevant patent rights of which they are aware and to provide supporting documentationä
Warning ã This document is not a European Standardä It is distributed for review and commentsä It is subject to change without notice and shall not be referred to as a European Standardä
EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels
9
t r s w CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Membersä Refä Noä FprEN
s r t xã t r s w EkSIST FprEN 1026:2015
FprEN 1026:2015 (E) 2 Contents Page European foreword . 3 1 Scope . 4 2 Normative references . 4 3 Terms and definitions . 4 4 Principle of test . 5 5 Test apparatus. 5 6 Preparation of test specimen . 6 7 Test procedure . 6 7.1 Preliminaries . 6 7.2 Air permeability of test chamber . 6 7.2.1 General . 6 7.2.2 Test chamber with known air permeability . 6 7.2.3 Test chamber with unknown air permeability . 6 7.3 Overall air permeability of test specimen and the test chamber – positive pressures . 7 7.3.1 General . 7 7.3.2 Measurement of air permeability for windows and pedestrian external doorsets . 7 7.3.3 Measurement of air permeability for pedestrian internal doorsets . 7 7.4 Overall air permeability of test specimen and the test chamber – negative pressures . 7 8 Test result . 7 9 Test report . 8 Annex A (informative)
Air permeability . 15 Bibliography . 16
kSIST FprEN 1026:2015
FprEN 1026:2015 (E) 3 European foreword This document (FprEN 1026:2015) has been prepared by Technical Committee CEN/TC 33 “Doors, windows, shutters, building hardware and curtain walling”, the secretariat of which is held by AFNOR. This document is currently submitted to the Formal Vote. This document will supersede EN 1026:2000. The revision of this European Standard clarifies the test method and does not affect existing test evidence of EN 1026:2000. In comparison with EN 1026:2000, the following significant changes were made: a) Clause 2: Deletion of "Normative references“; b) Clause 3: Supplement of definition “closing condition”; c) Sub-clause 3.2: Simplification of definition “test pressure”; d) Sub-clause 3.4 and 3.5: Revision of definition „opening joint“; e) Sub-clause 5.4: Revision of definition „accuracy“; f) Sub-clause 7.3: Addition of „closing condition“; g) Sub-clause 7.3: Separate test methods for measurement of air permeability for windows and external pedestrian doorsets in 7.3.2 and for internal pedestrian doorsets in 7.3.3; h) Clause 9: Supplement of necessary description of test specimen; i) Clause 9: Revision of Figures 1 and 2; j) Clause 9: Supplement of figures: - Figure 3 - Sliding door test specimen; - Figure 4 - Single leaf test specimen with fixed glazing; - Figure 5 - Single leaf test specimen with fixed glazing, extension profiles and shutter boxes; - Figure 6 - Pedestrian external / internal doorset; k) Revision of Annex A: Separation of figures into Figures A.1 and A.2. kSIST FprEN 1026:2015
FprEN 1026:2015 (E) 4 1 Scope This European Standard defines the test method to be used to determine the air permeability of completely assembled windows and doorsets of any material, when submitted to positive or negative test pressures. This test method is designed to take account of conditions in use, when the window or doorset is installed in accordance with the manufacturer’s specification and the requirements of relevant European Standards and codes of practice. This European Standard does not apply to the joints between the window or doorset frame and the building construction. 2 Normative references Not applicable. 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 closing condition 3.1.1 closed movable part rest in or at the fixed part in a way in which they may be fastened (latched and/or locked) 3.1.2 fastened where the movable part is restrained at one or more points and shall be described by at least one of the two as listed below: 3.1.2.1 latched movable part is returned to its closed position and restrained by either a) a self - engaging fastener or b) a roller catch or c) a latch 3.1.2.2 locked movable part is further restrained in the closed position by additional operations (of e.g. handle, key, automatic devices or electronic devices) to engage integrated locking devices (e.g. nutbolts or deadbolts) which will affect the product’s characteristics 3.1.3 secured any action(s) which prevent unauthorised release of the fastening device(s) to allow exit or entry (e.g. child safety, burglary) 3.2 test pressure difference between the static air pressures inside and outside of the test chamber kSIST FprEN 1026:2015
FprEN 1026:2015 (E) 5 Note 1 to entry: The test pressure is positive if the static air pressure inside the chamber of the test apparatus is higher than that outside the test chamber. Note 2 to entry: The test pressure is negative if the static air pressure inside the chamber of the test apparatus is lower than that outside the test chamber. 3.3 air permeability amount of air passing through all joints between casement or leaf and frame profiles of a test specimen caused by the test pressure Note 1 to entry: Air permeability should be expressed in cubic metres per hour (m3/h). 3.4 opening joint line of discontinuity between either a frame and its matched component or two components which can be opened by means of their building hardware (see Figures 1 to 6) Note 1 to entry: Conventionally, this discontinuity is as seen from the opening face of the test specimen. 3.5 length of opening joint length of the line of discontinuity as defined in 3.4 (see Figures 1 to 6) Note 1 to entry: The length of joint should be expressed in metres (m). Note 2 to entry: Actual length of gaskets or seals fitted into the underlying profiles of the components or joints of components built into opening parts are not relevant. 3.6 overall area area of the test specimen measured parallel to the glazing or the leaf (see Figures 1 to 6) Note 1 to entry: The overall area should be expressed in square metres (m2). 4 Principle of test Application of a defined series of test pressures (positive and negat
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.