Windows and doors - Product standard, performance characteristics - Part 2: Internal pedestrian doorsets

This European Standard identifies material independent performance characteristics that are applicable to internal pedestrian doorsets without resistance to fire and/or smoke leakage characteristics.
This document applies to doorsets intended to be used internally for construction works:
- in escape routes not subject to fire and/or smoke leakage;
- for specific uses with specific requirements;
- for communication only.
NOTE These above intended uses can be combined, for example escape routes with specific requirements.
Products covered by this European standard are power operated hinged or manually operated internal pedestrian doorsets and screens with flush or paneled leaves, single or double leaf, which could be completed with:
- related building hardware;
- door closing devices.
NOTE Manually operated doors with door closing devices are not power operated doors.
- integral fanlights;
- adjacent parts that are contained within a single frame for inclusion in a single aperture.
Products covered by this European standard are not assessed for structural applications.
This European standard does not apply to:
- industrial, commercial and garage doors and gates according to EN 13241-1;
- external pedestrian doorsets according to EN 14351-1;
- door leaves placed on the market separately;
- door frames placed on the market separately;
- power operated pedestrian doorsets according to EN 16361.
The noise emission of power operated interior hinged doors is not considered to be a relevant hazard; therefore this standard does not contain any specific requirements to noise.

Fenster und Türen - Produktnorm, Leistungseigenschaften - Teil 2: Innentüren

Die vorliegende Europäische Norm benennt werkstoffunabhängige Leistungsmerkmale, die auf Innentüren ohne Feuerschutz- und/oder Rauchdichtheitseigenschaften zutreffen.
Dieses Dokument gilt für Innentüren in Bauwerken, die für folgende Zwecke verwendet werden:
-   in Rettungswegen, die keinen Bestimmungen im Hinblick auf Feuerschutz und/oder Rauchdichtheit unterliegen;
-   für besondere Verwendungszwecke mit besonderen Anforderungen;
-   lediglich als Verbindung.
ANMERKUNG 1   Die oben genannten Anwendungsgebiete können kombiniert werden, z. B. Rettungswege mit besonderen Anforderungen.
Produkte, die durch diese Europäische Norm abgedeckt werden, sind kraftbetätigte Drehflügeltüren oder handbetätigte Innentüren und Vorsatztüren mit Sperr- oder Füllungstürblättern, ein- oder zweiflügelig, die ergänzt werden könnten mit:
-   zugehörigen Baubeschlägen;
-   Türschließmitteln.
ANMERKUNG 2   Handbetätigte Türen mit Türschließmitteln sind keine kraftbetätigten Türen.
-   integrierten Oberlichtern;
-   angrenzenden Seitenteilen, in einem einzigen (gemeinsamen) Rahmen zum Einbau in eine gemeinsame Öffnung.
Die in dieser Europäischen Norm beschriebenen Produkte sind nicht für eine Anwendung als tragende Bauteile geeignet.
Diese Europäische Norm gilt nicht für:
-   Tore nach EN 13241-1;
-   Außentüren nach EN 14351-1;
-   im Handel einzeln erhältliche Türblätter;
-   im Handel einzeln erhältliche Türrahmen;
-   kraftbetätigte Außentüren nach EN 16361.
Die Geräuschemission von kraftbetätigten Drehflügelinnentüren wird nicht als signifikante Gefährdung angesehen; deshalb enthält diese Norm keine besonderen Anforderungen bezüglich Lärm.

Portes et fenêtres - Norme produit, caractéristiques de performances - Partie 2: Blocs-portes intérieurs pour piétons

La présente Norme européenne détermine les caractéristiques de performance, indépendantes des matériaux, qui sont applicables aux blocs-portes intérieurs pour piétons sans caractéristiques de résistance au feu et/ou dégagement de fumée.
Le présent document s'applique aux blocs-portes destinés à être utilisés à l'intérieur des ouvrages de construction :
-   sur les issues de secours non soumises à des réglementations concernant la résistance au feu et/ou le dégagement de fumée ;
-   pour des usages spécifiques associés à des exigences particulières ;
-   pour la communication uniquement.
NOTE 1 : Les usages prévus indiqués ci-dessus peuvent être combinés, par exemple issues de secours associées à des exigences particulières.
Les produits couverts par la présente Norme européenne sont des blocs-portes battants intérieurs manuels ou motorisés pour piétons et ensembles composés avec vantaux plans ou menuisés, à un ou deux vantaux, pouvant être complétés :
-   de la quincaillerie associée ;
-   de dispositifs de fermeture de porte ;
NOTE 2 : Les portes manuelles avec dispositifs de fermeture de porte ne sont pas des portes motorisées.
-   d'impostes ;
-   de parties adjacentes qui sont intégrées dans un châssis individuel afin d'être installées dans une seule ouverture.
Les produits couverts par la présente Norme européenne ne sont pas destinés à des applications structurelles.
La présente Norme européenne ne s’applique pas aux :
-   portes industrielles, commerciales et de garages qui relèvent de l’EN 13241-1 ;
-   blocs-portes extérieurs pour piétons qui relèvent de l'EN 14351-1 ;
-   vantaux de portes commercialisés séparément ;
-   dormants commercialisés séparément ;
-   blocs-portes motorisés pour piétons qui relèvent de l'EN 16361.
L'émission sonore des portes battantes intérieures motorisées n'est pas considérée comme un phénomène dangereux pertinent ; par conséquent, la présente norme ne contient aucune exigence particulière relative au bruit.

Okna in vrata - Standard za proizvod, zahtevane lastnosti - 2. del: Notranja vrata

Ta evropski standard določa zahtevane lastnosti, ki niso odvisne od materialov in se uporabljajo za notranja vrata brez odpornosti proti požaru in/ali uhajanju dima.
Ta dokument se uporablja za vrata, ki so namenjena notranji uporabi pri gradbenih objektih:
– pri evakuacijskih poteh, ki niso podvržene požaru in/ali uhajanju dima;
– za posebne uporabe z posebnimi zahtevami;
– samo za komunikacijo.
OPOMBA: Te zgoraj predvidene uporabe je mogoče kombinirati, na primer evakuacijske poti s posebnimi zahtevami.
Izdelki, ki so zajeti v tem evropskem standardu, so električno ali ročno upravljana notranja vrata in rešetke z enoslojnimi ali dvoslojnimi gladkimi ali panelnimi krili, ki jih je mogoče dokončati s/z:
– ustreznim stavbnim okovjem;
– napravami za zapiranje vrat.
OPOMBA: Ročno upravljana vrata z napravami za zapiranje vrat niso električno upravljana vrata.
– pahljačastimi okenci nad vrati;
– soležnimi deli, ki so sestavni del enega okvirja za vključitev v eno odprtino.
Izdelki, ki so zajeti v tem evropskem standardu, niso ocenjeni za konstrukcijsko uporabo.
Ta evropski standard se ne uporablja za:
– vrata za industrijske in javne prostore ter garažna vrata v skladu s standardom EN 13241-1;
– zunanje sestave vrat za prehod ljudi v skladu s standardom EN 14351-1;
– vratna krila, ki so dana na trg ločeno;
– vratni okvirji, ki so dani na trg ločeno;
– električno upravljana zunanja vrata v skladu s standardom EN 16361.
Emisije hrupa električno upravljanih notranjih krilnih vrat se ne obravnavajo kot ustrezno tveganje; zaradi tega ta standard ne vsebuje nobenih posebnih zahtev glede hrupa.

General Information

Status
Published
Public Enquiry End Date
19-Aug-2014
Publication Date
05-Dec-2018
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
26-Nov-2018
Due Date
31-Jan-2019
Completion Date
06-Dec-2018

Buy Standard

Standard
EN 14351-2:2019
English language
53 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Draft
prEN 14351-2:2014
English language
58 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Okna in vrata - Standard za proizvod, zahtevane lastnosti - 2. del: Notranja vrataFenster und Türen - Produktnorm, Leistungseigenschaften - Teil 2: InnentürenPortes et fenêtres - Norme produit, caractéristiques de performances - Partie 2: Blocs-portes intérieurs pour piétonsWindows and doors - Product standard, performance characteristics - Part 2: Internal pedestrian doorsets91.060.50Vrata in oknaDoors and windowsICS:Ta slovenski standard je istoveten z:EN 14351-2:2018SIST EN 14351-2:2019en,fr,de01-januar-2019SIST EN 14351-2:2019SLOVENSKI
STANDARD



SIST EN 14351-2:2019



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 14351-2
November
t r s z ICS
{ sä r x rä w r English Version
Windows and doors æ Product standardá performance characteristics æ Part
tã Internal pedestrian doorsets Portes et fenêtres æ Norme produitá caractéristiques de performances æ Partie
tã Blocsæportes intérieurs pour piétons
Fenster und Türen æ Produktnormá Leistungseigenschaften æ Teil
tã Innentüren This European Standard was approved by CEN on
u April
t r s zä
egulations which stipulate the conditions for giving this European Standard the status of a national standard without any alterationä Upætoædate lists and bibliographical references concerning such national standards may be obtained on application to the CENæCENELEC Management Centre or to any CEN memberä
translation under the responsibility of a CEN member into its own language and notified to the CENæCENELEC Management Centre has the same status as the official versionsä
CEN members are the national standards bodies of Austriaá Belgiumá Bulgariaá Croatiaá Cyprusá Czech Republicá Denmarká Estoniaá Finlandá Former Yugoslav Republic of Macedoniaá Franceá Germanyá Greeceá Hungaryá Icelandá Irelandá Italyá Latviaá Lithuaniaá Luxembourgá Maltaá Netherlandsá Norwayá Polandá Portugalá Romaniaá Serbiaá Slovakiaá Sloveniaá Spainá Swedená Switzerlandá Turkey and United Kingdomä
EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Rue de la Science 23,
B-1040 Brussels
9
t r s z CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Membersä Refä Noä EN
s v u w sæ tã t r s z ESIST EN 14351-2:2019



EN 14351-2:2018 (E) 2 Contents Page European foreword . 5 1 Scope . 7 2 Normative references . 8 3 Terms, definitions and symbols .10 3.1 Terms and definitions .10 3.2 Symbols .11 4 Product characteristics .12 4.1 General .12 4.2 Release of dangerous substances (only for emissions into indoor air impact) (for intended use a, b and c) .12 4.3 Impact resistance (where relevant, only for glazed doors with injury risks) (for intended use a, b and c) .12 4.3.1 Glazed doors.12 4.3.2 Unframed glass doorsets .12 4.4 Height (for intended use a, b and c) .12 4.5 Reaction to fire .12 4.5.1 Reaction to fire of components (for intended use a, b and c).12 4.5.2 Reaction to fire of the doorset .13 4.6 Direct airborne sound insulation index (only for uses where acoustic performance is required) (for intended use b) .13 4.7 Operating forces (only for automatic devices and only for internal landing communication doors and doors for special uses and specific requirements) (for intended use b) .14 4.8 Thermal transmittance (only for uses where thermal insulation performance is required) (for intended use b) .14 4.9 Air permeability (only for uses where air permeability performance is required for specific use with specific requirements) (for intended use b) .14 4.10 Ability to release (to open) (only for locked doors in escape routes) (for intended use a) .14 4.11 Durability .14 4.11.1 Durability of air permeability against ageing/degradation for specific use with specific requirements (for intended use b): .14 4.11.2 Durability of operating forces (safety in use) against ageing/degradation (only for automatic devices and only for internal landing communication doors and doors for special uses with specific requirements) (for intended use b) .14 4.12 Width .15 4.13 Manual operating forces .15 4.14 Mechanical strength .15 4.15 Bullet resistance .15 4.16 Explosion resistance .15 4.17 Resistance to repeated opening and closing .15 4.18 Behaviour between two different climates .15 4.19 Burglar resistance .15 4.20 Safety requirements for power operated pedestrian hinged doorsets .16 4.21 Ventilation .16 SIST EN 14351-2:2019



EN 14351-2:2018 (E) 3 5 Testing, assessment and sampling methods . 16 5.1 General . 16 5.2 Dangerous substances . Error! Bookmark not defined. 5.3 Impact resistance (only for glazed doors with injury risk) (for intended use a, b and c) . Error! Bookmark not defined. 5.4 Height (for intended use a, b and c) . 16 5.5 Reaction to fire . 17 5.6 Direct airborne sound insulation index (only for uses where acoustic performance is required) (for intended use b) . 17 5.6.1 Reference method . 17 5.6.2 Alternative method . 17 5.7 Operating forces (only for automatic devices and only for internal landing communication doors and doors for special uses) (for intended use b) . 17 5.8 Thermal transmittance (only for uses where thermal insulation performance is required) (for intended use b) . 17 5.8.1 Reference method . 17 5.8.2 Tabulation . 18 5.8.3 Calculation . 18 5.9 Air permeability (only for uses where air permeability performance is required for specific use with specific requirements) (for intended use b). 18 5.10 Ability to release (to open) (only for locked doors in escape routes) (for intended use a) . 18 5.11 Durability . 18 5.11.1 Durability of air permeability against ageing/degradation (for intended use b). 18 5.11.2 Durability of operating forces (only for automatic devices, and only for internal landing communication doors and doors for special uses with specific requirements) (for intended use b) . 18 5.12 Width . 19 5.13 Manual operating forces . 19 5.14 Mechanical strength . 19 5.15 Bullet resistance . 19 5.16 Explosion resistance . 19 5.17 Resistance to repeated opening and closing. 19 5.18 Behaviour between two different climates . 19 5.19 Burglar resistance . 19 5.20 Safety requirements for power operated pedestrian hinged doorsets . 19 5.21 Ventilation . 20 6 Assessment and verification of constancy of performance – AVCP . 20 6.1 General . 20 6.2 Type testing . 20 6.2.1 General . 20 6.2.2 Test samples, testing and compliance criteria . 21 6.2.3 Test reports . 21 6.2.4 Shared other party results . 21 6.2.5 Cascading determination of the product type results . 22 6.3 Factory production control (FPC) . 23 6.3.1 General . 23 6.3.2 Requirements . 24 6.3.3 Product specific requirements . 26 6.3.4 Initial inspection of factory and of FPC . 26 6.3.5 Continuous surveillance of FPC (only for products covered by AVCP system 1) . 27 6.3.6 Procedure for modifications . 27 SIST EN 14351-2:2019



EN 14351-2:2018 (E) 4 6.3.7 One-off products, pre-production products (e.g. prototypes) and products produced in very low quantity .27 7 Marking, Labelling and packaging .28 Annex A (informative)
Product characteristics possibly affected by change of components .30 A.1 General .30 Annex B (normative)
Tabulated values and extension of test results following size and design variations .32 B.1 Characteristics of internal pedestrian doorsets .32 B.2 Sound insulation index of internal pedestrian doorsets .34 B.3 Thermal transmittance for Internal pedestrian doorsets UD in accordance to constructive details .35 Annex C (informative)
Example of performance and requirement profile of an Internal pedestrian doorsets .36 Annex D (informative)
Examples for opening dimensions of internal pedestrian doorsets 37 Annex E (informative)
Handling, installation, maintenance and care .39 Annex F (normative)
Selection, preparation, mounting and fixing of test sample(s) for reaction to fire tests and field of direct application .40 F.1 General .40 F.2 EN ISO 11925-2 (Single flame test) .40 F.2.1 Profile .40 F.2.2 Infill or door leaf .42 F.2.3 Sealant between infill and profile .42 F.2.4 Organic coating/top layers .43 F.3 Mounting and fixing for EN 13823 (SBI-test) .44 F.3.1 Testing of the individual components .44 F.3.2 Testing of the doorset .45 F.4 EN ISO 1182 (Non-combustibility test) .46 F.5 EN ISO 1716 (Determination of the heat of combustion) .46 F.6 Field of direct application .47 Annex ZA (informative)
Relationship of this European Standard with Regulation (EU) N°.305/2011 .48 ZA.1 Scope and relevant characteristics .48 ZA.2 System of assessment and Verification of Constancy of Performance (AVCP) .50 ZA.3 Assignment of AVCP tasks .50 Bibliography .53
SIST EN 14351-2:2019



EN 14351-2:2018 (E) 5 European foreword This document (EN 14351-2:2018) has been prepared by Technical Committee CEN/TC 33 “Doors, windows, shutters, building hardware and curtain walling”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by May 2019, and conflicting national standards shall be withdrawn at the latest by August 2021. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN shall not be held responsible for identifying any or all such patent rights. This document has been prepared under a standardisation request given to CEN by the European Commission and the European Free Trade Association, and supports Basic Work Requirements of EU Regulation and Essential Requirements of EU Directive(s). For relationship with EU Regulation/Directive(s), see informative Annex ZA, which is an integral part of this document. This European Standard is one of a series of standards for windows and pedestrian doorsets (see Figure 1). 1) EN 14351-2 alone, applies to all internal pedestrian doorsets. 2) For the internal pedestrian doorsets having fire resisting and/or smoke control characteristics, EN 16034 should apply in conjunction with EN 14351-2.
Figure 1 — Relationship between various standards SIST EN 14351-2:2019



EN 14351-2:2018 (E) 6 According to the CEN-CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. SIST EN 14351-2:2019



EN 14351-2:2018 (E) 7 1 Scope This European Standard identifies material independent performance characteristics, except resistance to fire and smoke control characteristics, which are applicable to internal pedestrian doorsets. Fire resisting and/or smoke control characteristics for pedestrian doorsets and openable windows are covered by EN 16034. This European Standard applies to doorsets intended to be used internally for construction works as: — intended use a) in escape routes; — intended use b) for specific uses with specific requirements; — intended use c) for communication only. NOTE 1 These above intended uses can be combined, for example escape routes with specific requirements. For internal pedestrian doorsets with resistance to fire and /or smoke control characteristics, this standard should only apply in conjunction with EN 16034. Products covered by this European Standard are power operated hinged or manually operated internal pedestrian doorsets and screens with flush or panelled leaves, single or double leaf, which could be completed with: — related building hardware; — door closing devices; — integral fanlights; — adjacent parts that are contained within a single frame for inclusion in a single aperture. NOTE 2 Manually operated doors with door closing devices are not considered to be power operated doors. Products covered by this European Standard are not assessed for structural applications. This European Standard does not apply to: — industrial, commercial and garage doors and gates according to EN 13241; — external pedestrian doorsets according to EN 14351-1; — door leaves placed on the market as a single unit; — door frames placed on the market as a single unit; — power operated pedestrian doorsets, other than swing type, according to EN 16361. Doorsets can be placed on the market with their component (leaf and frame) separate when each of these components are clearly identified. This European Standard does not deal with any specific requirements on noise emitted from internal power operated hinged doorsets as their noise emission is not considered to be a relevant hazard. SIST EN 14351-2:2019



EN 14351-2:2018 (E) 8 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 179, Building hardware — Emergency exit devices operated by a lever handle or push pad, for use on escape routes — Requirements and test methods EN 947, Hinged or pivoted doors — Determination of the resistance to vertical load EN 948, Hinged or pivoted doors — Determination of the resistance to static torsion EN 949, Windows and curtain walling, doors, blinds and shutters — Determination of the resistance to soft and heavy body impact for doors EN 950, Door leaves — Determination of the resistance to hard body impact EN 1026:2016, Windows and doors — Air permeability — Test method EN 1121, Doors - Behaviour between two different climates — Test method EN 1125, Building hardware — Panic exit devices operated by a horizontal bar, for use on escape routes — Requirements and test methods EN 1154, Building hardware — Controlled door closing devices — Requirements and test methods EN 1191, Windows and doors — Resistance to repeated opening and closing — Test method EN 1192, Doors — Classification of strength requirements EN 1522, Windows, doors, shutters and blinds — Bullet resistance — Requirements and classification EN 1523, Windows, doors, shutters and blinds — Bullet resistance — Test method EN 1627, Pedestrian doorsets, windows, curtain walling, grilles and shutters — Burglar resistance — Requirements and classification EN 1628, Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance under static loading EN 1629, Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance under dynamic loading EN 1630, Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance to manual burglary attempts EN 1935, Building hardware — Single-axis hinges — Requirements and test methods EN 12046-2, Operating forces — Test method — Part 2: Doors EN 12150-2, Glass in building — Thermally toughened soda lime silicate safety glass — Part 2: Evaluation of conformity/Product standard EN 12207, Windows and doors — Air permeability — Classification SIST EN 14351-2:2019



EN 14351-2:2018 (E) 9 EN 12217:2015, Doors — Operating forces — Requirements and classification EN 12219, Doors — Climatic influences — Requirements and classification EN 12365-1:2003, Building hardware — Gasket and weatherstripping for doors, windows, shutters and curtain walling — Part 1: Performance requirements and classification EN 12365-2, Building hardware — Gasket and weatherstripping for doors, windows, shutters and curtain walling — Part 2: Linear compression force test methods EN 12365-3, Building hardware — Gasket and weatherstripping for doors, windows, shutters and curtain walling — Part 3: Deflection recovery test method EN 12365-4, Building hardware — Gasket and weatherstripping for doors, windows, shutters and curtain walling — Part 4: Recovery after accelerated ageing test method EN 12400:2002, Windows and pedestrian doors — Mechanical durability — Requirements and classification EN 12519:2018, Windows and pedestrian doors — Terminology EN 12600:2002, Glass in building — Pendulum test — Impact test method and classification for flat glass EN 13049:2003, Windows — Soft and heavy body impact — Test method, safety requirements and classification EN 13123-1, Windows, doors and shutters — Explosion resistance — Requirements and classification — Part 1: Shock tube EN 13124-1, Windows, doors and shutters — Explosion resistance — Test method — Part 1: Shock tube EN 13141-1, Ventilation for buildings — Performance testing of components/products for residential ventilation — Part 1: Externally and internally mounted air transfer devices EN 13141-2, Ventilation for buildings — Performance testing of components/products for residential ventilation — Part 2: Exhaust and supply air terminal devices EN 13238, Reaction to fire tests for building products — Conditioning procedures and general rules for selection of substrates EN 13501-1, Fire classification of construction products and building elements — Part 1: Classification using data from reaction to fire tests EN 13637:2015, Building hardware — Electrically controlled exit systems for use on escape routes — Requirements and test methods EN 14179-2, Glass in building — Heat soaked thermally toughened soda lime silicate safety glass — Part 2: Evaluation of conformity/Product standard EN 14351-1, Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets EN 14449, Glass in building — Laminated glass and laminated safety glass — Evaluation of conformity/Product standard SIST EN 14351-2:2019



EN 14351-2:2018 (E) 10 EN 16005:2012, Power operated pedestrian doorsets — Safety in use — Requirements and test methods EN 16034, Pedestrian doorsets, industrial, commercial, garage doors and openable windows — Product standard, performance characteristics — Fire resisting and/or smoke control characteristics EN ISO 717-1, Acoustics — Rating of sound insulation in buildings and of building elements — Part 1: Airborne sound insulation (ISO 717-1) EN ISO 10077-1:2006, Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 1: General (ISO 10077-1:2017) EN ISO 10077-2, Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 2: Numerical method for frames (ISO 10077-2) EN ISO 10140-1, Acoustics — Laboratory measurement of so
...

SLOVENSKI STANDARD
oSIST prEN 14351-2:2014
01-julij-2014
2NQDLQYUDWD6WDQGDUG]DSURL]YRG]DKWHYDQHODVWQRVWLGHO1RWUDQMDYUDWD
EUH]GRORþHQLKODVWQRVWLSRåDUQHRGSRUQRVWLLQDOLGLPQRWHVQRVWL
Windows and doors - Product standard, performance characteristics - Part 2: Internal
pedestrian doorsets without resistance to fire and /or smoke leakage characteristics
Fenster und Türen - Produktnorm, Leistungseigenschaften - Teil 2: Innentüren ohne
Feuerschutz- und/oder Rauchdichtheitseigenschaften
Portes et fenêtres - Norme produit, caractéristiques de performances - Partie 2: Blocs-
portes intérieurs pour piétons sans caractéristiques de résistance au feu et/ou
dégagement de fumée
Ta slovenski standard je istoveten z: prEN 14351-2
ICS:
91.060.50 Vrata in okna Doors and windows
oSIST prEN 14351-2:2014 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
oSIST prEN 14351-2:2014

---------------------- Page: 2 ----------------------
oSIST prEN 14351-2:2014

EUROPEAN STANDARD
DRAFT
prEN 14351-2
NORME EUROPÉENNE

EUROPÄISCHE NORM

April 2014
ICS 91.060.50
English Version
Windows and doors - Product standard, performance
characteristics - Part 2: Internal pedestrian doorsets without
resistance to fire and /or smoke leakage characteristics
Portes et fenêtres - Norme produit, caractéristiques de Fenster und Türen - Produktnorm, Leistungseigenschaften -
performances - Partie 2: Blocs-portes intérieurs pour Teil 2: Innentüren ohne Feuerschutz- und/oder
piétons sans caractéristiques de résistance au feu et/ou Rauchdichtheitseigenschaften
dégagement de fumée
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee CEN/TC 33.

If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United
Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to
provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.


EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2014 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 14351-2:2014 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------
oSIST prEN 14351-2:2014
prEN 14351-2:2014 (E)
Contents Page
Foreword .5
1 Scope .6
2 Normative references .6
3 Terms and definitions .9
4 Requirements . 10
4.1 General . 10
4.2 Release of dangerous substances (only for emissions into indoor air) . 10
4.3 Impact resistance. 10
4.3.1 For glazed doors with injury risk . 10
4.3.2 Impact resistance for unframed glass doorsets . 10
4.4 Height . 11
4.5 Reaction to fire . 11
4.5.1 Reaction to fire of components of the product . 11
4.5.2 Reaction to fire of the doorset . 11
4.6 Direct airborne sound insulation (only for uses where acoustic performance is required) . 11
4.7 Operating forces (only for automatic devices and only for internal landing communication
doors and doors for special uses) . 12
4.8 Thermal transmittance (only for uses where thermal insulation performance is required) . 12
4.9 Air permeability (only for uses where air permeability performance is required) . 12
4.10 Suitability to open (only for doors in escape routes) . 12
4.11 Durability . 12
4.11.1 Durability of air permeability against ageing/degradation: . 12
4.11.2 Durability of operating forces (safety in use) (only for automatic devices and only for
internal landing communication doors and doors for special uses) . 12
4.12 Width of the clear opening within the frame . 13
4.13 Manual operating forces . 13
4.14 Mechanical strength . 13
4.15 Bullet resistance . 13
4.16 Explosion resistance . 13
4.17 Resistance to repeated opening and closing . 13
4.18 Behaviour between two different climates . 13
4.19 Burglar resistance . 14
4.20 Safety requirements for power operated pedestrian hinged doorsets . 14
5 Test method . 14
5.1 Impact resistance (only for glazed doors with injury risk) . 14
5.2 Height and width . 14
5.3 Reaction to fire . 14
5.4 Direct airborne sound insulation (only for uses where acoustic performance is required) . 14
5.5 Operating forces (only for automatic devices and only for internal landing communication
doors and doors for special uses) . 14
5.6 Thermal transmittance (only for uses where thermal insulation performance is required) . 14
5.7 Air permeability (only for uses where air permeability performance is required) . 15
5.8 Suitability to open (only for doors in escape routes) . 15
5.9 Durability . 15
5.9.1 Durability of air permeability . 15
5.9.2 Durability of operating forces (only for automatic devices and only for internal landing
communication doors and doors for special uses) . 15
5.10 Manually operating forces . 15
5.11 Mechanical strength . 16
2

---------------------- Page: 4 ----------------------
oSIST prEN 14351-2:2014
prEN 14351-2:2014 (E)
5.12 Bullet resistance . 16
5.13 Explosion resistance . 16
5.13.1 Shock tube . 16
5.13.2 Range test . 16
5.14 Resistance to repeated opening and closing . 16
5.15 Behaviour between two different climates . 16
5.16 Burglar resistance . 16
6 Assessment and verification of constancy of performance – AVCP . 16
6.1 General . 16
6.2 Type testing . 17
6.2.1 General . 17
6.2.2 Test samples, testing and compliance criteria . 18
6.2.3 Test reports . 18
6.2.4 Shared other party results . 18
6.2.5 Cascading determination of the product type results . 19
6.3 Factory production control (FPC) . 20
6.3.1 General . 20
6.3.2 Requirements . 20
6.3.3 Product specific requirements . 22
6.3.4 Initial inspection of factory and of FPC . 23
6.3.5 Continuous surveillance of FPC (only for products covered by AVCP system 1) . 23
6.3.6 Procedure for modifications. 24
6.3.7 One-off products, pre-production products (e.g. prototypes) and products produced in
very low quantity . 24
7 Marking, Labelling and packaging . 25
Annex A (informative) Product characteristics possibly affected by change of components . 26
A.1 General . 26
Annex B (normative) Extension of test results following the size. 28
B.1 Characteristics of internal pedestrian doorsets without resistance to fire and/or smoke
leakage characteristics . 28
B.2 Sound insulation of Internal pedestrian doorsets without resistance to fire and/or smoke
leakage characteristics . 30
B.3 Thermal transmittance for Internal pedestrian doorsets without resistance to fire and/or
smoke leakage characteristics U in accordance to constructive details . 31
D
Annex C (informative) Example of performance and requirement profile of an Internal pedestrian
doorsets without resistance to fire and/or smoke leakage characteristics . 34
Annex D (informative) Examples for opening dimensions of internal pedestrian doorsets without
resistance to fire and/or smoke leakage characteristics . 35
Annex E (informative) Handling, installation, maintenance and care. 36
Annex F (normative) Selection, preparation mounting and fixing of test specimen for reaction to
fire tests of pedestrian doorsets and field of direct application . 37
F.1 General . 37
F.2 EN ISO 11925-2 (Single flame test) . 37
F.2.1 Profile . 37
F.2.2 Infill or door slab . 38
F.2.3 Sealing between infill and profile . 39
F.2.4 Organic coating/top layers . 40
F.3 Mounting and fixing for EN 13823 (SBI-test) . 40
F.3.1 Testing of the individual components . 40
F.3.2 Testing of the doorset . 41
F.4 EN ISO 1182 (Non-combustibility test) . 42
F.5 EN ISO 1716 (Determination of the heat of combustion) . 42
F.6 Field of direct application . 43
Annex ZA (informative) Clauses of this European Standard addressing the provisions of the EU
Construction Products Regulation . 44
3

---------------------- Page: 5 ----------------------
oSIST prEN 14351-2:2014
prEN 14351-2:2014 (E)
ZA.1 Scope and relevant characteristics . 44
ZA.2 Procedure for AVCP of internal pedestrian doorsets without resistance to fire and/or
smoke leakage characteristics . 46
ZA.2.1 System(s) of AVCP . 46
ZA.2.2 Declaration of performance (DoP) . 48
ZA.2.2.1 General . 48
ZA.2.2.2 Content . 49
ZA.2.2.3 Example of DoP . 50
ZA.3 CE marking and labelling . 51
Annex ZB (informative) Relationship of this European Standard and the Essential Requirements of
EU Directive 2006/42/EC . 56
Annex ZC (informative) Relationship of this European Standard and the essential Requirements of
EU Directive 2004/108/EC . 57
Bibliography . 58

4

---------------------- Page: 6 ----------------------
oSIST prEN 14351-2:2014
prEN 14351-2:2014 (E)
Foreword
This document (prEN 14351-2:2014) has been prepared by Technical Committee CEN/TC 33 “Doors,
windows, shutters, building hardware and curtain walling”, the secretariat of which is held by AFNOR.
This document is currently submitted to the CEN Enquiry.
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association, and supports essential requirements of EU Directive(s).
For relationship with EU Directive(s), see informative Annex ZA, B and C, which is an integral part of this
document.
This European Standard is one of a series of standards for windows and pedestrian doorsets (see Figure 1).

Figure 1 — Relationship between various standards


5

---------------------- Page: 7 ----------------------
oSIST prEN 14351-2:2014
prEN 14351-2:2014 (E)
1 Scope
This European Standard identifies material independent performance characteristics that are applicable to
internal pedestrian doorsets without resistance to fire and/or smoke leakage characteristics.
This document applies to doorsets intended to be used internally for construction works:
 in escape routes not subject to fire and/or smoke leakage;
 for specific uses with specific requirements;
 for communication only.
NOTE 1 These above intended uses can be combined, for example escape routes with specific requirements.
Products covered by this European standard are power operated hinged or manually operated internal
pedestrian doorsets and screens with flush or paneled leaves, single or double leaf, which could be completed
with:
 related building hardware;
 door closing devices.
NOTE 2 Manually operated doors with door closing devices are not power operated doors.
 integral fanlights;
 adjacent parts that are contained within a single frame for inclusion in a single aperture.
Products covered by this European standard are not assessed for structural applications.
This European standard does not apply to:
 industrial, commercial and garage doors and gates according to EN 13241-1;
 external pedestrian doorsets according to EN 14351-1;
 door leaves placed on the market separately;
 door frames placed on the market separately;
 power operated pedestrian doorsets according to EN 16361.
The noise emission of power operated interior hinged doors is not considered to be a relevant hazard;
therefore this standard does not contain any specific requirements to noise.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
EN 179, Building hardware — Emergency exit devices operated by a lever handle or push pad —
Requirements and test method.
EN 947, Hinged or pivoted doors — Determination of the resistance to vertical load
6

---------------------- Page: 8 ----------------------
oSIST prEN 14351-2:2014
prEN 14351-2:2014 (E)
EN 948, Hinged or pivoted doors — Determination of the resistance to static torsion
EN 949, Windows and curtain walling, doors, blinds and shutters — Determination of the resistance to soft
and heavy body impact for doors
EN 950, Door leaves — Determination of the resistance to hard body impact
EN 951, Door leaves – Method for measurement of height, width, thickness and squareness
EN 1121, Doors — Behaviour between two different climates — Test method
EN 1125, Building hardware — Panic exit devices operated by a horizontal bar for use in escape routes —
Requirements and test methods
EN 1154, Building hardware — Controlled door closing devices — Requirements and test method
EN 1191, Windows and doors — Resistance to repeated opening and closing — Test method
EN 1192, Doors — Classification of strength requirements
EN 1522, Windows, doors, shutters and blinds — Bullet resistance — Requirements and classification
EN 1523, Windows, doors, shutters and blinds — Bullet resistance — Test method
EN 1627, Windows, doors, shutters — Burglar resistance — Requirements and classification
EN 1628, Windows, doors, shutters — Burglar resistance — Test method for the determination of resistance
under static loading
EN 1629, Windows, doors, shutters — Burglar resistance — Test method for the determination of resistance
under dynamic loading
EN 1630, Windows, doors, shutters — Burglar resistance — Test method for the determination of resistance
to manual burglary attempts
EN 1935, Building hardware — Single-axis hinges — Requirements and test methods
EN 12046-2, Operating forces — Test method — Part 2: Doors
EN 12150-2, Glass in building — Thermally toughened soda lime silicate safety glass — Part 2: Evaluation of
conformity/product standard
EN 12207:1999, Windows and doors — Air permeability — Classification
EN 12217, Doors — Operating forces — Requirements and classification
EN 12219, Doors — Climatic influences — Requirements and classification
EN 12365-1:2003 Building hardware – Gasket and weatherstripping for doors, windows, shutters and curtain
walling – Part 1: Performance requirements and classification
EN 12365-2:2003 Building hardware – Gasket and weatherstripping for doors, windows, shutters and curtain
walling Part 2: Linear compression test method
EN 12365-3:2003 Building hardware - Gasket and weatherstripping for doors, windows, shutters and curtain
walling - Part 3: Deflection recovery test method
EN 12365-4:2003 Building hardware - Gasket and weatherstripping for doors, windows, shutters and curtain
walling - Part 4: Recovery after accelerated ageing test method
7

---------------------- Page: 9 ----------------------
oSIST prEN 14351-2:2014
prEN 14351-2:2014 (E)
EN 12400, Windows and pedestrian doors — Mechanical durability — Requirements and classification
EN 12519:2004, Windows and doors — Terminology
EN 12600, Glass in building –Pendulum test – Impact test method and classification for flat glass
EN 13049, Windows — Soft and heavy body impact — Test method, safety requirements and classification
EN 13123-1, Windows, doors and shutters — Explosion resistance — Requirements and classification —
Part 1: Shock tube
EN 13123-2, Windows, doors and shutters — Explosion resistance — Test method — Part 2: Range test
EN 13124-1, Windows, doors and shutters — Explosion resistance — Test method — Part 1: Shock tube
EN 13124-2, Windows, doors and shutters — Explosion resistance — Test method — Part 2: Range test
EN 13241-1, Industrial, commercial and garage doors and gates — Product standard — Part 1: Products
without fire resistance or smoke control characteristics
EN 13501-1, Fire classification of construction products and building elements – Part 1: Classification using
data from reaction to fire tests
EN 14179-2, Glass in building — Heat soaked thermally toughened soda lime silicate safety glass — Part 2 :
Evaluation of conformity/product standard
EN 14351-1, Windows and doors — Product standard, performance characteristics — Part 1: Windows and
external pedestrian doorsets without resistance to fire and/or smoke leakage characteristics
EN 14449, Glass in building — Laminated glass and laminated safety glass — Evaluation of
conformity/product standard
EN 16005, Powered pedestrian doors – Safety in use of power pedestrian doors – Requirements and test
methods
EN ISO 140-3, Acoustics — Measurement of sound insulation in buildings and of building elements — Part 3:
Laboratory measurements of airborne sound insulation of building elements (ISO 140-3)
EN ISO 717-1, Acoustics — Rating of sound insulation in buildings and of building elements — Part 1:
Airborne sound insulation (ISO 717-1)
EN ISO 10077-1:2006 Thermal performance of windows, doors and shutters — Calculation of thermal
transmittance — Part 1: Simplified method (ISO 10077-1)
EN ISO 10077-2:2003, Thermal performance of windows, doors and shutters — Calculation of thermal
transmittance — Part 2: Numerical method for frames (ISO 10077-2)
EN ISO 10140-1, Acoustics –Laboratory measurement of sound insulation of building elements – Part 1:
Application rules for specific products (ISO 10140-1)
EN ISO 10140-2, Acoustics –Laboratory measurement of sound insulation of building elements – Part 2:
Measurement of airborne sound insulation (ISO 10140-2)
EN ISO 12567-1:2000, Thermal resistance of windows and doors — Determination of thermal transmittance
by hot box method — Part 1: Complete windows and doors (ISO 12567-1)
prEN 1026:2013, Windows and doors — Air permeability — Test method
prEN 13637, Building hardware — Electrically controlled emergency exit systems, for use on escape routes —
Requirements and test methods
8

---------------------- Page: 10 ----------------------
oSIST prEN 14351-2:2014
prEN 14351-2:2014 (E)
prEN 15887, Building hardware, Uncontrolled door closing devices for single action doors – Requirements and
test methods
prEN 16034, Pedestrian doorsets, industrial, commercial, garage doors and windows — Product standard,
performance characteristics — Fire resistance and/or smoke control characteristics
3 Terms and definitions
For the purposes of this European Standard units and symbols given in ISO 1000:1992 apply and terms and
definitions given in EN 14351-1, prEN 16034 and EN 12519 apply together with the following:
3.1
internal pedestrian doorset
building component which is designed and used to close a permanent opening in internal separating elements
and for which the main intended use is the access of pedestrians (e.g. entry doors into flats or into offices and
fulfilling the provision above should be considered as a
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.