Low-voltage electrical installations - Part 7-701: Requirements for special installations or locations - Locations containing a bath or shower

2019-11-26: This prAA will provide Common Modifications, A-deviations and SNCs to FprHD ( PR=63183)

Errichten von Niederspannungsanlagen - Teil 7-701: Anforderungen für Betriebsstätten, Räume und Anlagen besonderer Art - Räume mit Badewanne oder Dusche

Installations électriques à basse tension - Partie 7-701: Exigences pour les installations et emplacements spéciaux - Emplacements contenant une baignoire ou une douche

Nizkonapetostne električne inštalacije - 7-701. del: Zahteve za posebne inštalacije ali lokacije - Prostori s kadjo ali prho - Dopolnilo AA

General Information

Status
Not Published
Public Enquiry End Date
28-Feb-2023
Current Stage
4020 - Public enquire (PE) (Adopted Project)
Start Date
10-Jan-2023
Due Date
30-May-2023
Completion Date
11-May-2023

Buy Standard

Draft
k FprHD 60364-7-701:2019/oprAA:2023
English language
10 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
kSIST FprHD 60364-7-701:2019/oprAA:2023
01-februar-2023
Nizkonapetostne električne inštalacije - 7-701. del: Zahteve za posebne inštalacije
ali lokacije - Prostori s kopalno kadjo ali tušem - Dopolnilo AA
Low-voltage electrical installations - Part 7-701: Requirements for special installations or
locations - Locations containing a bath or shower
Errichten von Niederspannungsanlagen - Teil 7-701: Anforderungen für Betriebsstätten,
Räume und Anlagen besonderer Art - Räume mit Badewanne oder Dusche
Installations électriques à basse tension - Partie 7-701: Exigences pour les installations
et emplacements spéciaux - Emplacements contenant une baignoire ou une douche
Ta slovenski standard je istoveten z: FprHD 60364-7-701:2019/prAA
ICS:
91.140.50 Sistemi za oskrbo z elektriko Electricity supply systems
91.140.70 Sanitarne naprave Sanitary installations
kSIST FprHD 60364-7- en
701:2019/oprAA:2023
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
kSIST FprHD 60364-7-701:2019/oprAA:2023

---------------------- Page: 2 ----------------------
kSIST FprHD 60364-7-701:2019/oprAA:2023


HARMONIZATION DOCUMENT DRAFT
FprHD 60364-7-701:2019
DOCUMENT D'HARMONISATION

HARMONISIERUNGSDOKUMENT
prAA
December 2022
ICS 29.020; 91.140.50 -
English Version
Low-voltage electrical installations - Part 7-701: Requirements
for special installations or locations - Locations containing a bath
or shower
Installations électriques à basse tension - Partie 7-701: Errichten von Niederspannungsanlagen - Teil 7-701:
Exigences pour les installations et emplacements spéciaux Anforderungen für Betriebsstätten, Räume und Anlagen
- Emplacements contenant une baignoire ou une douche besonderer Art - Räume mit Badewanne oder Dusche
This draft amendment prAA, if approved, will modify the Harmonization Document FprHD 60364-7-701:2019; it is submitted to CENELEC
members for enquiry.
Deadline for CENELEC: 2023-03-10.

It has been drawn up by CLC/TC 64.

If this draft becomes an amendment, CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for implementation of this amendment on a national level.

This draft amendment, was established by CENELEC in three official versions (English, French, German).

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Türkiye and the United Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to
provide supporting documentation.

Warning : This document is not a Harmonization Document. It is distributed for review and comments. It is subject to change without notice
and shall not be referred to as a Harmonization Document.


European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2022 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Project: 70970 Ref. No. FprHD 60364-7-701:2019/prAA E

---------------------- Page: 3 ----------------------
kSIST FprHD 60364-7-701:2019/oprAA:2023
European foreword
This document (FprHD 60364-7-701:2019/prAA) has been prepared by CLC/TC 64 "Electrical
installations and protection against electric shock".
The following dates are proposed:
• latest date by which the existence of this (doa) dor + 6 months
document has to be announced at national
level
• latest date by which this document has to be (dop) dor + 12 months
implemented at national level by publication of
an identical national standard or by
endorsement
• latest date by which the national standards (dow) dor + 36 months
conflicting with this document have to be (to be confirmed or
withdrawn modified when voting)

---------------------- Page: 4 ----------------------
kSIST FprHD 60364-7-701:2019/oprAA:2023
FprHD 60364-7-701:2019/prAA (E)
1 Modification to 701.531, “Devices for protection against indirect contact by
automatic disconnection of supply”
Rename the subclause as follows:
“701.531 Devices for protection against electric shock by automatic disconnection of supply”

2

---------------------- Page: 5 ----------------------
kSIST FprHD 60364-7-701:2019/oprAA:2023
FprHD 60364-7-701:2019/prAA (E)
Annex ZA
(normative)

Special national conditions
Special national condition: National characteristic
...

Questions, Comments and Discussion