SIST EN 60079-29-1:2017/A1:2022
(Amendment)Explosive atmospheres - Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases (IEC 60079-29-1:2016/A1:2020)
Explosive atmospheres - Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases (IEC 60079-29-1:2016/A1:2020)
NEXT ACTION: TB ACTION BY 2020-01-31 (prep doc for BT meeting - Feb2021)
BT CONSULTATION FAILED (addition of Annex ZZ) ON 2020-11-10
HAS CONSULTANT ASSESSMENT BY 2020-09-24 (PUB assessment) - Compliant assessment on 2020-09-22
2020-04-8 mah: Consultant assessment at FV missing, Annex ZZ did not go to FV.
Explosionsfähige Atmosphäre - Teil 29-1: Gasmessgeräte - Anforderungen an das Betriebsverhalten von Geräten für die Messung brennbarer Gase (IEC 60079-29-1:2016/A1:2020)
Atmosphères explosives - Partie 29-1: Détecteurs de gaz - Exigences d'aptitude à la fonction des détecteurs de gaz inflammables (IEC 60079-29-1:2016/A1:2020)
Eksplozivne atmosfere - 29-1. del: Javljalniki plina - Zahteve za delovanje javljalnikov vnetljivih plinov (IEC 60079-29-1:2016/A1:2020)
General Information
- Status
- Published
- Publication Date
- 09-Oct-2022
- Technical Committee
- EXP - Product for explosive atmospheres
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 19-May-2022
- Due Date
- 24-Jul-2022
- Completion Date
- 10-Oct-2022
Relations
- Effective Date
- 18-Dec-2018
- Effective Date
- 22-Jun-2021
- Effective Date
- 30-Jul-2024
Overview
EN 60079-29-1:2016/A1:2022 (CENELEC adoption of IEC 60079-29-1:2016/A1:2020) is an amendment that updates the performance requirements and type‑testing provisions for detectors of flammable gases used in explosive atmospheres. The amendment was approved by CENELEC (2020-04-28) and includes informative Annex ZZ describing the relationship with Directive 2014/34/EU, providing a presumption of conformity when the standard is cited in the Official Journal.
This amendment clarifies test sequencing, test-sample usage, electromagnetic compatibility (EMC) testing, and performance criteria applicable to gas detection equipment and systems intended for hazardous locations.
Key Topics
Scope and status: Amendment to EN 60079-29-1:2016; aligns the European standard with IEC 60079-29-1:2016/A1:2020 and supports essential requirements of the ATEX Directive (2014/34/EU) via Annex ZZ.
Type testing and test samples: Most applicable type tests are to be carried out on the same sample. Separate samples are permitted for specific tests (e.g., subclauses 5.4.4.3–5.4.4.6, 5.4.16, 5.4.20, 5.4.21). If a sample fails during testing, the laboratory and manufacturer shall agree which tests require repetition and document the decision in the test report.
Test sequence: The unpowered storage test is performed before other tests. The vibration test is normally executed after unpowered storage as pre-conditioning, with exceptions for the specified separate-sample tests.
EMC requirements: EMC testing is referenced to IEC 61326‑1:2012, Table 2. The amendment defines hierarchical performance criteria (A, B, C) for functions associated with gas detection and measurement, and specifies how standard test gas or equivalent simulation may be used during EMC exposure. For multi‑gas portable equipment, tests must be performed with a full set of typical sensors.
Performance criteria: Criteria A, B and C describe allowable degradations, fault indications, or temporary loss of function during EMC tests, and require self-recovery or easy restoration of functionality post-test where applicable.
Applications
- Selection and certification of fixed and portable flammable‑gas detectors for industrial sites (petrochemical, chemical, mining, utilities).
- Type testing and factory assessment to demonstrate reliable detection, alarm set‑point integrity, EMC resilience and compliance for equipment used in potentially explosive atmospheres.
- Supporting technical files for CE/ATEX conformity assessment when the standard is referenced in the Official Journal.
Related Standards
- IEC 60079‑29‑1:2016/A1:2020 (base international document)
- IEC 61326‑1:2012 (EMC testing referenced)
- Directive 2014/34/EU (ATEX) - see Annex ZZ for correspondence and presumption of conformity
For implementers, manufacturers and testing labs, EN 60079-29-1:2016/A1:2022 provides practical, testable criteria to ensure gas detectors operate reliably under the environmental, mechanical and electromagnetic stresses encountered in hazardous locations.
Frequently Asked Questions
SIST EN 60079-29-1:2017/A1:2022 is a amendment published by the Slovenian Institute for Standardization (SIST). Its full title is "Explosive atmospheres - Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases (IEC 60079-29-1:2016/A1:2020)". This standard covers: NEXT ACTION: TB ACTION BY 2020-01-31 (prep doc for BT meeting - Feb2021) BT CONSULTATION FAILED (addition of Annex ZZ) ON 2020-11-10 HAS CONSULTANT ASSESSMENT BY 2020-09-24 (PUB assessment) - Compliant assessment on 2020-09-22 2020-04-8 mah: Consultant assessment at FV missing, Annex ZZ did not go to FV.
NEXT ACTION: TB ACTION BY 2020-01-31 (prep doc for BT meeting - Feb2021) BT CONSULTATION FAILED (addition of Annex ZZ) ON 2020-11-10 HAS CONSULTANT ASSESSMENT BY 2020-09-24 (PUB assessment) - Compliant assessment on 2020-09-22 2020-04-8 mah: Consultant assessment at FV missing, Annex ZZ did not go to FV.
SIST EN 60079-29-1:2017/A1:2022 is classified under the following ICS (International Classification for Standards) categories: 13.320 - Alarm and warning systems; 29.260.20 - Electrical apparatus for explosive atmospheres. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 60079-29-1:2017/A1:2022 has the following relationships with other standards: It is inter standard links to SIST EN 60079-29-1:2017, SIST EN 60079-29-1:2017/A11:2022, kSIST FprEN IEC 60079-29-0:2025. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN 60079-29-1:2017/A1:2022 is associated with the following European legislation: EU Directives/Regulations: 2014/34/EU; Standardization Mandates: M/BC/CEN/92/46. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
You can purchase SIST EN 60079-29-1:2017/A1:2022 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of SIST standards.
Standards Content (Sample)
SLOVENSKI STANDARD
01-november-2022
Eksplozivne atmosfere - 29-1. del: Javljalniki plina - Zahteve za delovanje
javljalnikov vnetljivih plinov (IEC 60079-29-1:2016/A1:2020)
Explosive atmospheres - Part 29-1: Gas detectors - Performance requirements of
detectors for flammable gases (IEC 60079-29-1:2016/A1:2020)
Explosionsfähige Atmosphäre - Teil 29-1: Gasmessgeräte - Anforderungen an das
Betriebsverhalten von Geräten für die Messung brennbarer Gase (IEC 60079-29-
1:2016/A1:2020)
Atmosphères explosives - Partie 29-1: Détecteurs de gaz - Exigences d'aptitude à la
fonction des détecteurs de gaz inflammables (IEC 60079-29-1:2016/A1:2020)
Ta slovenski standard je istoveten z: EN 60079-29-1:2016/A1:2022
ICS:
13.320 Alarmni in opozorilni sistemi Alarm and warning systems
29.260.20 Električni aparati za Electrical apparatus for
eksplozivna ozračja explosive atmospheres
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD EN 60079-29-1:2016/A1
NORME EUROPÉENNE
EUROPÄISCHE NORM May 2022
ICS 29.260.20
English Version
Explosive atmospheres - Part 29-1: Gas detectors - Performance
requirements of detectors for flammable gases
(IEC 60079-29-1:2016/A1:2020)
Atmosphères explosives - Partie 29-1: Détecteurs de gaz - Explosionsfähige Atmosphäre - Teil 29-1: Gasmessgeräte -
Exigences d'aptitude à la fonction des détecteurs de gaz Anforderungen an das Betriebsverhalten von Geräten für
inflammables die Messung brennbarer Gase
(IEC 60079-29-1:2016/A1:2020) (IEC 60079-29-1:2016/A1:2020)
This amendment A1 modifies the European Standard EN 60079-29-1:2016; it was approved by CENELEC on 2020-04-28. CENELEC
members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this amendment the
status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language made by translation under the
responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as
the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2022 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 60079-29-1:2016/A1:2022 E
European foreword
The text of document 31/1525/FDIS, future IEC 60079-29-1/A1, prepared by IEC/TC 31 "Equipment
for explosive atmospheres" was submitted to the IEC-CENELEC parallel vote and approved by
CENELEC as EN 60079-29-1:2016/A1:2022.
The following dates are fixed:
• latest date by which the document has to be implemented at national (dop) 2022-11-13
level by publication of an identical national standard or by endorsement
• latest date by which the national standards conflicting with the (dow) 2025-05-13
document have to be withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
This document is read in conjunction with EN 60079-29-1:2016/A11:2022.
This document has been prepared under a Standardization Request given to CENELEC by the
European Commission and the European Free Trade Association, and supports essential
requirements of EU Directive(s) / Regulation(s).
For the relationship with EU Directive(s) / Regulation(s), see informative Annex ZZ, included in this
document.
Any feedback and questions on this document should be directed to the users’ national committee. A
complete listing of these bodies can be found on the CENELEC website.
Endorsement notice
The text of the International Standard IEC 60079-29-1:2016/A1:2020 was approved by CENELEC as
a European Standard without any modification.
Annex ZZ
(informative)
Relationship between this European Standard and the essential requirements
of Directive 2014/34/EU [2014 OJ L96] aimed to be covered
This European Standard has been prepared under a Commission’s standardization request
[M/BC/CEN/92/46] to provide one voluntary means of conforming to essential requirements of
Directive 2014/34/EU of the European Parliament and of the Council of 26 February 2014 on the
harmonisation of the laws of the Member States relating to equipment and protective systems
intended for use in potentially explosive atmospheres [2014 OJ L96].
Once this standard is cited in the Official Journal of the European Union under that Directive,
compliance with the normative clauses of this standard given in Table ZZ.1 confers, within the limits of
the scope of this standard, a presumption of conformity with the corresponding essential requirements
of that Directive, and associated EFTA regulations.
Table ZZ.1 – Correspondence between this European Standard and
Annex II of Directive 2014/34/EU [2014 OJ L96]
Essential Requirements of Clause(s) / sub-clause(s)
Remarks / Notes
Directive 2014/34/EU of this EN
1.5.5 - 1.5.7 whole standard except 4.2.9
and 5.4.23
1.5.8 4.2.9, 5.4.23
WARNING 1 — Presumption of conformity stays valid only as long as a reference to this European
standard is maintained in the list published in the Official Journal of the European Union. Users of this
standard should consult frequently the latest list published in the Official Journal of the European
Union.
WARNING 2 — Other Union legislation may be applicable to the product(s) falling within the scope of
this standard.
IEC 60079-29-1 ®
Edition 2.0 2020-03
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
A MENDMENT 1
AM ENDEMENT 1
Explosive atmospheres –
Part 29-1: Gas detectors – Performance requirements of detectors for flammable
gases
Atmosphères explosives –
Partie 29-1: Détecteurs de gaz – Exigences d’aptitude à la fonction des
détecteurs de gaz inflammables
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 29.260.20 ISBN 978-2-8322-7966-3
– 2 – IEC 60079-29-1:2016/AMD1:2020
IEC 2020
FOREWORD
This amendment has been prepared by IEC technical committee 31 Equipment for explosive
atmospheres
The text of this amendment is based on the following documents:
FDIS Report on voting
31/1525/FDIS 31/1533/RVD
Full information on the voting for the approval of this amendment
...










Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.