Test methods for analysis of lead in PVC taken from insulation and sheath of electric and optical fibre cables - Method A: Total lead content determination with flame excitation atomic absorption spectrometry - Method B: Qualitative analysis of lead by lead sulphide staining

This European Standard describes two methods for the analysis of lead in PVC-insulating and sheathing materials for electric and for optical fibre cables. The samples of PVC are taken from the finished cable. Method A provides a quantitative method and Method B provides a qualitative method.  NOTE 1   Users may refer to either Method A or Method B or to both methods.  NOTE 2   Other methods of determination not specified here are known to be capable of achieving equivalent results, but do not conform to this EN (see “Introduction”). Both Method A and Method B are applicable to products having a total lead content greater than or equal to 0,01 %.

Prüfverfahren für die Analyse von Blei in PVC entnommen aus Isolierung und Mantel von Kabeln, isolierten Leitungen und Lichtwellenleiterkabeln - Verfahren A: Bestimmung des Gesamtbleigehalts mit der Flammen-Atomabsorptionsspektrometrie - Verfahren B: Qualitative Analyse des Bleigehalts durch Bleisulfidverfärbung

Diese Europäische Norm beschreibt zwei Verfahren der Bestimmung von Blei in PVC-Isolier- und Mantelmischungen in elektrischen und optischen Kabeln. Die PVC-Proben sind dem fertigen Kabel zu entnehmen. Das Verfahren A beschreibt eine quantitative und das Verfahren B eine qualitative Methode. ANMERKUNG 1   Anwender können sich entweder auf Verfahren A oder Verfahren B oder auf beide Verfahren beziehen. ANMERKUNG 2   Mit anderen, hier nicht aufgeführten, Verfahren kann man bekanntlich gleichwertige Ergebnisse erzielen; sie sind jedoch nicht konform mit dieser EN (siehe „Einleitung“).  Beide Verfahren A und B können auf Produkte mit einem Gesamtbleigehalt von größer oder gleich 0,01 % angewendet werden.

Méthodes d'analyse du plomb dans le PVC prélevé de l'enveloppe isolante et des gaines des câbles électriques et à fibres optiques - Méthode A: Détermination de la teneur totale en plomb par spectrométrie atomique d'absorption dans la flamme - Méthode B: Analyse qualitative du plomb par production de sulfure de plomb

Cette Norme Européenne décrit deux méthodes pour l’analyse du plomb dans des matériaux d’isolation et de gainage en PVC, utilisés pour les câbles électriques et les câbles à fibres optiques. Les échantillons de PVC sont prélevés sur le câble fini. La méthode A est une méthode quantitative et la méthode B est une méthode qualitative. NOTE 1   Les utilisateurs peuvent se référer, soit à la méthode A, soit à la méthode B, ou aux deux méthodes. NOTE 2   D’autres méthodes pour la détermination, non spécifiées ici, sont connues comme étant capables d’obtenir des résultats équivalents, mais elles ne sont pas conformes à la présente EN (voir “Introduction”). Les deux méthodes, A et B, sont applicables aux produits ayant une teneur totale en plomb supérieure ou égale à 0,01 %.

Preskusne metode za analizo svinca v PVC (polivinilkloridu), ki se uporablja za izolacijo in oplaščenje električnih kablov in kablov z optičnimi vlakni - Metoda A: Določevanje celotnega svinca z atomsko absorpcijsko spektrometrijo z vzbujanjem plamena - Metoda B: Kvalitativna metoda z barvanjem s svinčevim sulfidom

General Information

Status
Published
Publication Date
30-Sep-2006
Technical Committee
IEKA - Electric cables
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Oct-2006
Due Date
01-Oct-2006
Completion Date
01-Oct-2006

Buy Documents

Standard

SIST EN 50414:2006

English language (11 pages)
Preview
Preview
e-Library read for
1 day

Relations

Effective Date
03-Feb-2026

Overview

SIST EN 50414:2006 is a European standard specifying test methods for the analysis of lead in polyvinyl chloride (PVC) materials taken from the insulation and sheath of electric and optical fibre cables. Developed by the Slovenski inštitut za standardizacijo (SIST), this standard addresses both quantitative and qualitative determination of lead content. PVC-insulated and sheathed cables are widely used in electrical and telecommunications industries, making accurate detection and control of lead content crucial for regulatory compliance and environmental safety.

This document provides two validated test methods:

  • Method A: Quantitative determination of total lead content using flame excitation atomic absorption spectrometry (AAS).
  • Method B: Qualitative analysis of lead by lead sulphide staining.

Both methods are applicable to products with a total lead content equal to or above 0.01%.

Key Topics

1. Quantitative Analysis with AAS (Method A)

  • Determines total lead content in PVC insulation and sheath.
  • Employs flame excitation AAS, a highly sensitive and specific analytical chemistry technique.
  • Requires representative sampling from finished cables, precise sample preparation, and the use of calibration solutions and reference curves.
  • Results are calculated and reported as micrograms of lead per gram of PVC.

2. Qualitative Lead Detection (Method B)

  • Involves lead sulphide staining as a quick screening test.
  • Suitable primarily for light-colored or natural PVC materials.
  • Detects the presence of lead visually by observing discoloration (black/grey staining) after exposure to hydrogen sulfide.
  • Intended for routine checks or as a supplementary test to quantitative measurement.

3. Applicability and Limitations

  • Only suitable for products with lead content ≥ 0.01%.
  • The accuracy of Method A ensures compliance in case of disputes.
  • Method B is not specific and may indicate other metal sulfides besides lead.

4. Reporting and Documentation

  • Both methods require detailed reporting:
    • Identification of tested material and source cable.
    • Reference to EN 50414.
    • Test date and results.
    • Any deviation from standard procedures.

Applications

The standard is essential for manufacturers, laboratories, and compliance professionals in sectors using or producing:

  • Electric cables: Power, control, and communication cables that require lead content verification for safety and environmental compliance.
  • Optical fibre cables: Ensuring PVC components meet lead content regulations in high-performance fibre optic applications.
  • Regulatory compliance: Meeting RoHS and REACH directives by documenting evidence of lead content determination.
  • Quality control: Routine or spot-check testing during cable manufacturing to prevent unintentional non-conformity.
  • Environmental and health safety assessments: Reducing hazardous substance levels in products brought to market.

Related Standards

For effective laboratory practice and to ensure conformance with EN 50414, refer to these related standards:

  • EN ISO 1042 - Laboratory glassware - One-mark volumetric flasks.
  • EN ISO 3696 - Water for analytical laboratory use.
  • ISO 6503 - Paints and varnishes - Determination of total lead - Flame AAS method.
  • ISO 5725 - Accuracy (trueness and precision) of measurement methods and results.

These documents support the proper execution of test methods, calibration, and quality assurance for accurate, reliable lead analysis in PVC materials.


By following SIST EN 50414:2006, organizations demonstrate responsible management of hazardous substances in cable products and maintain international market readiness through documented, standardized lead analysis procedures.

Buy Documents

Standard

SIST EN 50414:2006

English language (11 pages)
Preview
Preview
e-Library read for
1 day

Get Certified

Connect with accredited certification bodies for this standard

IMQ S.p.A. (Certification)

Italian electrical product certification.

ACCREDIA Italy Verified

SLG Prüf- und Zertifizierungs GmbH

German testing and certification body.

DAKKS Germany Verified

UL Solutions

Global safety science company with testing, inspection and certification.

ANAB United States Verified

Sponsored listings

Frequently Asked Questions

SIST EN 50414:2006 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Test methods for analysis of lead in PVC taken from insulation and sheath of electric and optical fibre cables - Method A: Total lead content determination with flame excitation atomic absorption spectrometry - Method B: Qualitative analysis of lead by lead sulphide staining". This standard covers: This European Standard describes two methods for the analysis of lead in PVC-insulating and sheathing materials for electric and for optical fibre cables. The samples of PVC are taken from the finished cable. Method A provides a quantitative method and Method B provides a qualitative method. NOTE 1 Users may refer to either Method A or Method B or to both methods. NOTE 2 Other methods of determination not specified here are known to be capable of achieving equivalent results, but do not conform to this EN (see “Introduction”). Both Method A and Method B are applicable to products having a total lead content greater than or equal to 0,01 %.

This European Standard describes two methods for the analysis of lead in PVC-insulating and sheathing materials for electric and for optical fibre cables. The samples of PVC are taken from the finished cable. Method A provides a quantitative method and Method B provides a qualitative method. NOTE 1 Users may refer to either Method A or Method B or to both methods. NOTE 2 Other methods of determination not specified here are known to be capable of achieving equivalent results, but do not conform to this EN (see “Introduction”). Both Method A and Method B are applicable to products having a total lead content greater than or equal to 0,01 %.

SIST EN 50414:2006 is classified under the following ICS (International Classification for Standards) categories: 29.035.20 - Plastics and rubber insulating materials; 29.060.20 - Cables. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 50414:2006 has the following relationships with other standards: It is inter standard links to SIST HD 605 S2:2009. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN 50414:2006 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI SIST EN 50414:2006
STANDARD
oct 2006
Preskusne metode za analizo svinca v PVC (polivinilkloridu), ki se uporablja
za izolacijo in oplaščenje električnih kablov in kablov z optičnimi vlakni -
Metoda A: Določevanje celotnega svinca z atomsko absorpcijsko
spektrometrijo z vzbujanjem plamena - Metoda B: Kvalitativna metoda z
barvanjem s svinčevim sulfidom
Test methods for analysis of lead in PVC taken from insulation and sheath of
electric and optical fibre cables - Method A: Total lead content determination with
flame excitation atomic absorption spectrometry - Method B: Qualitative analysis of
lead by lead sulphide staining
ICS 29.035.20; 29.060.20 Referenčna številka
©  Standard je založil in izdal Slovenski inštitut za standardizacijo. Razmnoževanje ali kopiranje celote ali delov tega dokumenta ni dovoljeno

EUROPEAN STANDARD
EN 50414
NORME EUROPÉENNE
April 2006
EUROPÄISCHE NORM
ICS 29.035.20
English version
Test methods for analysis of lead in PVC taken from insulation
and sheath of electric and optical fibre cables -
Method A: Total lead content determination
with flame excitation atomic absorption spectrometry -
Method B: Qualitative analysis of lead by lead sulphide staining

Méthodes d'analyse du plomb  Prüfverfahren für die Analyse von Blei
dans le PVC prélevé de l'enveloppe in PVC entnommen aus Isolierung
isolante et des gaines des câbles und Mantel von Kabeln, isolierten
électriques et à fibres optiques - Leitungen und Lichtwellenleiterkabeln -
Méthode A: Détermination de la teneur Verfahren A: Bestimmung
totale en plomb par spectrométrie des Gesamtbleigehalts mit der Flammen-
atomique d'absorption dans la flamme - Atomabsorptionsspektrometrie -
Méthode B: Analyse qualitative du plomb Verfahren B: Qualitative Analyse
par production de sulfure de plomb des Bleigehalts durch Bleisulfidverfärbung

This European Standard was approved by CENELEC on 2006-03-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, the Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels

© 2006 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50414:2006 E
Foreword
This European Standard was prepared by the Technical Committee CENELEC TC 20, Electric cables.
The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 50414 on
2006-03-01.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2007-03-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2009-03-01
__________
- 3 - EN 50414:2006
Contents
Introduction.4
1 Scope .4
2 Normative references .4
3 Methods of analysis .5
3.1 General .5
3.2 Method A.5
3.2.1 Principle .5
3.2.2 Reagents.5
3.2.3 Apparatus.6
3.2.4 Sampling .6
3.2.5 Test procedure .6
3.2.6 Determination .7
3.2.7 Tests results.9
3.2.8 Test report.10
3.3 Method B.10
3.3.1 Principle .10
3.3.2 Reagents.10
3.3.3 Apparatus.10
3.3.4 Procedure.10
3.3.5 Determination .11
3.3.6 Test report.11
Table 1 - Preparation of reference solutions.8

Introduction
The determination of small quantities of lead in PVC is possible using a number of analytical techniques.
For the purposes of this European Standard two alternative methods are given.
Method A uses flame excitation atomic absorption spectrometry, for the total lead determination in the
PVC.
Method B uses a qualitative method for the analysis of lead in the PVC. The method utilises the lead
sulfide staining test and is therefore best suited to light coloured or natural materials. It can be considered
to be a spot check for the presence of lead or lead compounds.
Other decomposition and determination methods are capable of detecting and analysing small amounts
of lead in cable grade PVC. Examples of such methods are X-ray fluorescence spectroscopy, graphite
furnace atomic absorption spectrometry, inductively coupled plasma spectrometry and polarography.
Contracting parties may agree to use such other methods, but such methods cannot claim conformity to
EN 50414. If used, it is recommended that such methods have at least equivalent sensitivity and
detection levels as those in this EN.
1 Scope
This European Standard describes two methods for the analysis of lead in PVC-insulating and sheathing
materials for electric and for optical fibre cables. The samples of PVC are taken from the finished cable.
Method A provides a quantitative method and Method B provides a qualitative method.
NOTE 1  Users may refer to either Method A or Method B or to both methods.
NOTE 2  Other methods of determination not specified here are known to be capable of achieving equivalent results, but do not
conform to this EN (see “Introduction”).
Both Method A and Method B are applicable to products having a total lead content greater than or equal
to 0,01 %.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
Publication Year Title
EN ISO 1042 1999 Laboratory glassware - One-mark volumetric flasks (ISO 1042:1998)
EN ISO 3696 1995 Water for analytical laboratory use - Specification and test methods
(ISO 3696:1987)
ISO 385-1 1984 Laboratory glassware - Burettes - Part 1: General requirements
ISO 5725 Series Accuracy (trueness and precision) of measurement methods and
results
ISO 6503 1984 Paints and varnishes - Determination of total lead - Flame atomic
absorption spectrometric method

- 5 - EN 50414:2006
3 Methods of analysis
3.1 General
In case of dispute, the decomposition of the material by the dry calcination method and the analysis of the
material by the flame excitation atomic absorption spectrometry (Method A of this standard) shall be the
reference method. Method A has been derived from ISO 6503.
3.2 Method A
3.2.1 Principle
The lead content is determined using flame excitation atomic absorption spectrometry following the
decomposition of a sample by dry calcination and acid extraction of the residue.
3.2.2 Reagents
During the decomposition and extraction, use only reagents of a recognized analytical quality, and
demineralized or distilled water of a purity of at least Grade 3 in accordance with EN ISO 3696.
3.2.2.1 sodium carbonate, anhydrous
3.2.2.2 magnesium carbonate
3.2.2.3 sulfur
3.2.2.4 sodium sulfide, solution at 10 g/l
3.2.2.5 hydrochloric acid, at approximately 180 g/l
450 ml of concentrated hydrochloric acid (36 %, with a specific gravity ρ of approximately 1,18 g/ml) shall
be added to approximately 450 ml of water and shall be made up to 1 000 ml.
3.2.2.6 hydrochloric acid, at approximately 18 g/l
100 ml of hydrochloric acid (made up in 3.2.2.5) shall be added to water, and shall be made up to
1 000 ml.
3.2.2.7 nitric acid, at approximately 315 g/l
One volume of concentrated nitric acid (about 65 %, with a specific gravity ρ of approximately 1,40 g/ml)
shall be added to two volumes of water.
3.2.2.8 lead reference solution, containing 1 g of lead per litre
Exactly 1 g of lead shall be dissolved in 30 ml of the nitric acid prepared in 3.2.2.7 and shall be
transferred, using a funnel, to a 1 000 ml volumetric flask. Distilled or deionized water shall be used to
dilute the solution to the mark and shall be mixed well.
1 ml of this reference solution shall contain 1 mg of lead.
NOTE  ISO 6503 gives further details for the preparation of this solution.
3.2.2.9 lead reference solution, containing 100 mg of lead per litre
This solution shall be prepared fresh each day of its use.

10 ml of the reference solution (see 3.2.2.8) shall be transferred with the aid of a pipette into a 100 ml
volumetric flask, and shall be diluted to the mark with hydrochloric acid (see 3.2.2.6) and shall be mixed
well.
1 ml of this reference solution shall contain 100 µg of lead.
3.2.3 Apparatus
Ordinary laboratory apparatus, and
3.2.3.1 silica crucibles, preferably new
3.2.3.2 muffle furnace, at (475 ± 25) °C
3.2.3.3 hot plate with thermostatic control
3.2.3.4 desiccator
3.2.4 Sampling
Take from the cable a representative sample of the material to be tested. The sample shall be cut into
small pieces of approximately 0,05 g.
3.2.5 Test procedure
3.2.5.1 Preliminary tests
If the composition of the material to be tested is not known, carry out qualitative tests to determine
whether antimony is present. If the results of these tests confirm the presence of antimony, the extraction
shall be carried out as specified in 3.2.5.4.2; if not, use the method described in 3.2.5.4.1.
3.2.5.2 Sampl
...