Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Jacketed or screened and jacketed - Part 004: Tin plated copper - Operating temperatures, between - 65 °C and 135 °C - Single extruded wall for open applications, with jacket and screen (braid) - UV laser printable - Product standard

This document specifies the characteristics of UV laser printable jacket, tin plated copper conductor, electrical cables Crosslinked Ethylene Tetra Fluoro Ethylene co-polymer (XLETFE) family for use in the on board electrical systems of aircraft operating at temperatures between - 65 °C and 135 °C, operating at voltages not exceeding 600 V rms at sea level. This insulation system has been used in aerospace applications using 115 V (phase-to-neutral) 400 Hz ac and 28 Vdc. Verification of the suitability of cables for use in other electrical systems is the responsibility of the user. These jacketed cables are suitable for airframe use without additional protection when the jacket is present. When the jacket is stripped back the cores may need additional protection. In case of conflict between this standard and other referenced documents the requirements of this standard shall take precedence.

Luft- und Raumfahrt - Ein- und mehradrige elektrische Leitungen für allgemeine Verwendung - XLETFE Familie - mit Mantel oder geschirmt und Mantel - Teil 004: Kupfer verzinnt - Betriebstemperaturen zwischen –65 °C und 135 °C - Einfach extrudierte Isolierung für externe Verwendung, mit Mantel und Schirm (Geflecht) - UV-Laser bedruckbar - Produktnorm

Série aérospatiale - Câbles, électriques, d'usage général, mono et multiconducteurs - Famille XLETFE - Gainés ou blindés et gainés - Partie 004 : Cuivre étamé - Températures de fonctionnement comprises entre -65 °C et 135 °C - Fil simple isolé pour applications externes, gainé et blindé (tressé) - Marquable au laser UV - Norme de produit

Aeronavtika - Kabli, električni, za splošne namene, eno- in večžilni - Družina XLETFE - Oplaščeni ali zaslonjeni in oplaščeni - 004. del: Pocinjeni baker - Obratovalne temperature med –65 °C in 135 °C - Enojno ekstrudirana izolacija za zunanjo uporabo, s plaščem in zaslonom (opletom) - Potiskljiva z UV-laserjem - Standard za proizvod

Ta dokument določa lastnosti električnih oplaščenih kablov, potiskljivih z UV-laserjem, z vodnikom iz pocinjenega bakra iz družine kopolimerov, pridobljenih z mrežno polimerizacijo etilena in tetrafluoroetilena (XLETFE), za uporabo v električnih sistemih na krovu letal pri obratovalnih temperaturah med –65 in 135 °C in obratovalnih napetostih, ki ne presegajo 600 V RMS na morski gladini. Ta izolacijski sistem se je uporabljal v aeronavtiki pri izmenični napetosti 115 V (za fazno napetost) pri 400 Hz in 28 V pri enosmerni napetosti. Za preverjanje ustreznosti kablov za uporabo v drugih električnih sistemih je odgovoren uporabnik. Ti oplaščeni kabli so primerni za uporabo na ogrodjih letal brez dodatne zaščite, kadar je prisoten plašč. Kadar je plašč odstranjen, ožilje morda potrebuje dodatno zaščito. V primeru neskladja med tem standardom in drugimi navedenimi dokumenti imajo prednost določila tega standarda.

General Information

Status
Published
Publication Date
30-Sep-2019
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
02-Sep-2019
Due Date
07-Nov-2019
Completion Date
01-Oct-2019

Relations

Buy Standard

Standard
EN 4612-004:2019
English language
11 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 4612-004:2019
01-november-2019
Nadomešča:
SIST EN 4612-004:2012
Aeronavtika - Kabli, električni, za splošne namene, eno- in večžilni - Družina
XLETFE - Oplaščeni ali zaslonjeni in oplaščeni - 004. del: Pocinjeni baker -
Obratovalne temperature med –65 °C in 135 °C - Enojno ekstrudirana izolacija za
zunanjo uporabo, s plaščem in zaslonom (opletom) - Potiskljiva z UV-laserjem -
Standard za proizvod
Aerospace series - Cables, electrical, for general purpose, single and multicore
assembly - XLETFE Family - Jacketed or screened and jacketed - Part 004: Tin plated
copper - Operating temperatures, between - 65 °C and 135 °C - Single extruded wall for
open applications, with jacket and screen (braid) - UV laser printable - Product standard
Luft- und Raumfahrt - Ein- und mehradrige elektrische Leitungen für allgemeine
Verwendung - XLETFE Familie - mit Mantel oder geschirmt und Mantel - Teil 004: Kupfer
verzinnt - Betriebstemperaturen zwischen –65 °C und 135 °C - Einfach extrudierte
Isolierung für externe Verwendung, mit Mantel und Schirm (Geflecht) - UV-Laser
bedruckbar - Produktnorm
Ta slovenski standard je istoveten z: EN 4612-004:2019
ICS:
29.060.20 Kabli Cables
49.060 Letalska in vesoljska Aerospace electric
električna oprema in sistemi equipment and systems
SIST EN 4612-004:2019 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST EN 4612-004:2019

---------------------- Page: 2 ----------------------
SIST EN 4612-004:2019


EN 4612-004
EUROPEAN STANDARD

NORME EUROPÉENNE

August 2019
EUROPÄISCHE NORM
ICS 49.060 Supersedes EN 4612-004:2011
English Version

Aerospace series - Cables, electrical, for general purpose,
single and multicore assembly - XLETFE Family - Jacketed
or screened and jacketed - Part 004: Tin plated copper -
Operating temperatures, between - 65 °C and 135 °C -
Single extruded wall for open applications, with jacket and
screen (braid) - UV laser printable - Product standard
Série aérospatiale - Câbles, électriques, d'usage Luft- und Raumfahrt - Ein- und mehradrige elektrische
général, mono et multiconducteurs - Famille XLETFE - Leitungen zur allgemeinen Verwendung - XLETFE-
Gainés ou blindés et gainés - Partie 004 : Cuivre étamé Familie - Ummantelt oder geschirmt und ummantelt -
- Températures de fonctionnement comprises entre - Teil 004: Kupfer verzinnt - Betriebstemperaturen
65 °C et 135 °C - Fil simple isolé pour applications zwischen -65 °C und 135 °C - einfach extrudierte
externes, gainé et blindé (tressé) - Marquable au laser Isolierung für offene Anwendungen, ummantelt und
UV - Norme de produit geschirmt (Geflecht) - UV-Laser bedruckbar -
Produktnorm
This European Standard was approved by CEN on 5 May 2019.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.

This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.





EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2019 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 4612-004:2019 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------
SIST EN 4612-004:2019
EN 4612-004:2019 (E)
Contents Page
European foreword . 3
1 Scope . 4
2 Normative references . 4
3 Terms, definitions and symbols . 4
4 Materials and construction . 5
5 Required characteristics . 7
6 Quality assurance . 10
7 Designation . 10
8 Identification and marking . 10
9 Packaging, labelling and delivery lengths . 11
10 Technical specification . 11

2

---------------------- Page: 4 ----------------------
SIST EN 4612-004:2019
EN 4612-004:2019 (E)
European foreword
This document (EN 4612-004:2019) has been prepared by the Aerospace and Defence Industries
Association of Europe - Standardization (ASD-STAN).
After enquiries and votes carried out in accordance with the rules of this Association, this Standard has
received the approval of the National Associations and the Official Services of the member countries of
ASD, prior to its presentation to CEN.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by February 2020, and conflicting national standards shall
be withdrawn at the latest by February 2020.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN 4612-004:2011.
According to the CEN-CENELEC Internal Regulations, the national standards organisations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia,
Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland,
Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Republic of North
Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United
Kingdom.
3

---------------------- Page: 5 ----------------------
SIST EN 4612-004:2019
EN 4612-004:2019 (E)
1 Scope
This document specifies the characteristics of UV laser printable jacket, tin plated copper conductor,
electrical cables Crosslinked Ethylene Tetra Fluoro Ethylene co-polymer (XLETFE) family for use in the
on board electrical systems of aircraft operating at temperatures between – 65 °C and 135 °C, operating
at voltages not exceeding 600 V rms at sea level. This insulation system has been used in aerospace
applications using 115 V (phase-to-neutral) 400 Hz ac and 28 Vdc. Verification of the suitability of cables
for use in other electrical systems is the responsibility of the user.
These jacketed cables are suitable for airframe use without additional protection when the jacket is
present. When the jacket is stripped back the cores may need additional protection. In case of conflict
between this standard and other referenced documents the requirements of this standard shall take
precedence.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the lat
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.