Universal Personal Telecommunication (UPT); UPT phase 2; Functional specification of the interface of a UPT Integrated Circuit Card (ICC) and Card Accepting Devices (CAD); UPT card accepting Dual Tone Multiple Frequency (DTMF) device

This second edition of ETS 300 477 intends to correct and enhance the first version.

Svetovne osebne telekomunikacije (UPT) – UPT, faza 2 – Funkcijska specifikacija vmesnika čipne kartice (ICC) sistema UPT in naprav za sprejemanje te kartice (CAD) – Dvotonska večfrekvenčna (DTMF) naprava, ki sprejema kartice UPT

General Information

Status
Published
Publication Date
30-Nov-2003
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Dec-2003
Due Date
01-Dec-2003
Completion Date
01-Dec-2003

Buy Standard

Standard
EN 300 477 V1.2.2:2003
English language
91 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 300 477 V1.2.2:2003
01-december-2003
6YHWRYQHRVHEQHWHOHNRPXQLNDFLMH 837 ±837ID]D±)XQNFLMVNDVSHFLILNDFLMD
YPHVQLNDþLSQHNDUWLFH ,&& VLVWHPD837LQQDSUDY]DVSUHMHPDQMHWHNDUWLFH
&$' ±'YRWRQVNDYHþIUHNYHQþQD '70) QDSUDYDNLVSUHMHPDNDUWLFH837
Universal Personal Telecommunication (UPT); UPT phase 2; Functional specification of
the interface of a UPT Integrated Circuit Card (ICC) and Card Accepting Devices (CAD);
UPT card accepting Dual Tone Multiple Frequency (DTMF) device
Ta slovenski standard je istoveten z: EN 300 477 Version 1.2.2
ICS:
33.040.35 Telefonska omrežja Telephone networks
35.240.15 Identifikacijske kartice in Identification cards and
sorodne naprave related devices
SIST EN 300 477 V1.2.2:2003 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 300 477 V1.2.2:2003

---------------------- Page: 2 ----------------------

SIST EN 300 477 V1.2.2:2003
EN 300 477 V1.2.2 (1999-05)
European Standard (Telecommunications series)
Universal Personal Telecommunication (UPT);
UPT phase 2;
Functional specification of the interface of a UPT Integrated
Circuit Card (ICC) and Card Accepting Devices (CAD);
UPT card accepting Dual Tone Multiple
Frequency (DTMF) device

---------------------- Page: 3 ----------------------

SIST EN 300 477 V1.2.2:2003
2 ETSI EN 300 477 V1.2.2 (1999-05)
Reference
REN/NA-064012 (4f000ipc.PDF)
Keywords
card, DTMF, UPT
ETSI
Postal address
F-06921 Sophia Antipolis Cedex - FRANCE
Office address
650 Route des Lucioles - Sophia Antipolis
Valbonne - FRANCE
Tel.: +33 4 92 94 42 00  Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88
Internet
secretariat@etsi.fr
Individual copies of this ETSI deliverable
can be downloaded from
http://www.etsi.org
If you find errors in the present document, send your
comment to: editor@etsi.fr
Copyright Notification
No part may be reproduced except as authorized by written permission.
The copyright and the foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 1999.
All rights reserved.
ETSI

---------------------- Page: 4 ----------------------

SIST EN 300 477 V1.2.2:2003
3 ETSI EN 300 477 V1.2.2 (1999-05)
Contents
Intellectual Property Rights . 7
Foreword. 7
1 Scope. 8
2 References . 8
3 Definitions, symbols and abbreviations. 9
3.1 Definitions . 9
3.2 Symbols . 10
3.3 Abbreviations. 11
4 Physical characteristics. 11
4.1 Format and layout . 11
4.1.1 ID-1 size. 12
4.1.2 Plug-in size. 12
4.2 Temperature range for card operation. 12
4.3 Contacts . 12
4.3.1 Provision of contacts. 12
4.3.2 Activation and deactivation. 12
4.3.3 Contact pressure. 13
4.4 Precedence. 13
5 Electronic signals and transmission protocols. 13
5.1 Supply voltage . 13
5.2 Reset (RST) (contact C2). 14
5.3 Programming voltage. 14
5.4 Clock (CLK) . 14
5.5 I/O (contact C7) . 14
5.6 States. 15
5.7 Baud rate. 15
5.8 ATR . 15
5.8.1 Structure and contents . 15
5.8.2 PTS procedure. 17
5.9 Error handling. 17
6 Logical model . 18
6.1 General model. 18
6.2 File identifier . 18
6.3 MF . 19
6.4 Dedicated Files . 19
6.5 EFs. 19
6.5.1 Transparent EF. 19
6.5.2 Linear fixed EF . 20
6.5.3 Cyclic EF. 20
6.6 Methods for selecting a file. 21
6.7 Reservation of file IDs. 22
7 Security services and facilities . 23
7.1 Authentication key . 23
7.2 Algorithms and processes . 23
7.2.1 Card Holder Verification. 23
7.2.2 Strong authentication. 24
7.3 File access conditions . 24
7.4 Function access condition. 25
7.5 Identification, keying and algorithm information. 25
ETSI

---------------------- Page: 5 ----------------------

SIST EN 300 477 V1.2.2:2003
4 ETSI EN 300 477 V1.2.2 (1999-05)
8 Description of the functions . 25
8.1 SELECT. 26
8.2 READ BINARY . 26
8.3 UPDATE BINARY . 27
8.4 READ RECORD . 27
8.5 UPDATE RECORD . 28
8.6 SEEK . 28
8.7 VERIFY CHV . 29
8.8 CHANGE CHV . 30
8.9 UNBLOCK CHV. 30
8.10 INTERNAL AUTHENTICATION . 31
9 Description of the commands . 31
9.1 Mapping principles . 31
9.1.1 Command Application Protocol Data Unit . 31
9.1.2 Response APDU. 31
9.1.3 Command APDU conventions . 31
9.2 Definitions and coding. 31
9.3 Coding of the commands . 32
9.3.1 SELECT. 32
9.3.2 READ BINARY. 37
9.3.3 UPDATE BINARY. 37
9.3.4 READ RECORD. 37
9.3.5 UPDATE RECORD. 38
9.3.6 SEEK. 38
9.3.7 VERIFY CHV. 39
9.3.8 CHANGE CHV. 39
9.3.9 UNBLOCK CHV. 39
9.3.10 INTERNAL AUTHENTICATION. 39
9.3.11 GET RESPONSE. 40
9.4 Access condition coding . 40
9.5 Coding of CHVs and UNBLOCK CHVs. 41
9.6 Status conditions returned by the card . 41
9.6.1 Security management . 41
9.6.2 Memory management. 41
9.6.3 Referencing management . 42
9.6.4 Application independent errors . 42
9.6.5 Responses to commands which are correctly executed or supporting chaining mechanism. 42
9.6.6 Commands versus possible status responses . 42
10 Contents of the EFs. 43
10.1 EF . 44
CHV1
10.2 Contents of the EFs at the MF level. 44
10.2.1 EF . 45
ID
10.2.2 EF . 45
ICC
10.2.3 EF (Directory) . 46
DIR
10.2.4 EF (Language preference) . 46
LANG
10.2.5 EF . 47
NAME
10.3 Contents of files at the UPT application level . 47
10.3.1 EF . 47
CT
10.3.2 EF (PUI) . 47
PUI
10.3.3 EF (Sequence number). 48
SEQ
10.3.4 EF (PIM service table) . 48
PST
10.3.5 EF (Time-out value). 49
TV
10.3.6 EF (Maximum time-out value) . 50
MTV
10.4 Contents of files at the telecom level . 50
10.4.1 EF (Abbreviated Dialling Numbers). 50
ADN
10.4.2 EF (Last number dialled) . 52
LND
10.4.3 EF (Extension1). 52
EXT1
ETSI

---------------------- Page: 6 ----------------------

SIST EN 300 477 V1.2.2:2003
5 ETSI EN 300 477 V1.2.2 (1999-05)
11 Application protocol. 54
11.1 General procedures . 56
11.1.1 Reading an EF (M). 56
11.1.2 Updating an EF (M) . 56
11.1.3 Seeking in an EF (O). 56
11.1.4 Selecting an EF or DF (M). 57
11.2 PIM management procedures. 57
11.2.1 PIM initialization (M) . 59
11.2.2 PIM session (M). 60
11.2.3 PIM session termination (M). 61
11.2.4 Application selection procedure (M). 61
11.2.5 Check services (M) . 62
11.2.5A Start timer. 62
11.2.6 Timer value substitution (O) . 63
11.3 CHV related procedures . 63
11.3.1 CHV verification (M). 63
11.3.2 CHV value substitution (O). 64
11.3.3 CHV unblocking (O). 64
11.4 UPT security related procedures. 65
11.4.1 One pass strong authentication (M). 65
11.5 Telecom procedures (O) . 66
11.5.1 Dialling numbers. 66
11.5.1.1 Update . 67
11.5.1.2 Erasure. 69
11.5.1.3 Request . 70
11.5.1.4 Purge. 71
11.6 General information procedures. 72
11.6.1 NAME request procedure (O). 72
11.6.2 Language preference procedures (O) . 72
11.6.2.1 Request . 72
11.6.2.2 Update . 73
Annex A (normative): Plug-in UPT card . 74
Annex B (normative): Implementation Conformance Statement (ICS) for the PIM. 75
B.1 ICS proforma for the PIM. 75
B.2 Identification of the implementation, product supplier and test laboratory client . 75
B.3 Identification of the standard. 75
B.4 Global statement of conformance. 76
B.5 Interpretation of the tables. 76
B.6 Physical characteristics. 76
B.6.1 ID-1 size . 77
B.6.2 Plug-in size . 77
B.6.3 Contacts . 77
B.7 Electronic signals and transmission protocols. 77
B.7.1 Supply voltage VCC (contact C1) . 78
B.7.2 Reset RST (contact C2) . 78
B.7.3 Clock CLK (contact C3) . 78
B.7.4 I/O (contact C7) . 78
B.7.5 States. 79
B.7.6 Answer to Reset (ATR) . 79
ETSI

---------------------- Page: 7 ----------------------

SIST EN 300 477 V1.2.2:2003
6 ETSI EN 300 477 V1.2.2 (1999-05)
B.8 Logical model . 80
B.9 Security features and facilities. 80
B.10 Description of functions . 81
B.11 Contents of the EFs. 81
Annex C (normative): Implementation Conformance Statement (ICS) for the CAD . 82
UPT
C.1 ICS proforma for the CAD . 82
UPT
C.2 Identification of the implementation, product supplier and test laboratory client . 82
C.3 Identification of the standard. 82
C.4 Global statement of conformance. 83
C.5 Interpretation of the tables. 83
C.6 Physical characteristics. 84
C.7 Electronic signals and transmission protocols. 84
C.7.1 Supply voltage VCC (contact C1) . 85
C.7.2 Reset RST (contact C2) . 85
C.7.3 Clock CLK (contact C3) . 85
C.7.4 I/O (contact C7) . 85
C.7.5 States.
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.