Energy performance of lamp controlgear - Part 1: Controlgear for fluorescent lamps - Method of measurement to determine the total input power of controlgear circuits and the efficiency of controlgear (IEC 62442-1:2022)

This part of IEC 62442 defines a measurement and calculation method of the total input power
for controlgear-lamp circuits when operating with their associated fluorescent lamp(s). The
calculation method for the efficiency of the lamp controlgear is also defined. This document
applies to electrical controlgear-lamp circuits consisting only of the controlgear and the lamp(s).
It is intended for use on DC supplies up to 1 000 V and/or AC supplies up to 1 000 V at 50 Hz
or 60 Hz.
NOTE Requirements for testing individual controlgear during production are not included.
This document specifies the measurement method for the total input power and the calculation
method of the controlgear efficiency for all controlgear used for domestic and normal
commercial purposes operating with the following fluorescent lamps:
– double-capped fluorescent lamps (IEC 60081);
– single-capped fluorescent lamps (IEC 60901);
– other general purpose low-pressure mercury fluorescent lamps.
This document does not apply to:
– controlgear which form an integral part of the lamp;
– controllable wire-wound magnetic controlgear.

Energieeffizienz von Lampenbetriebsgeräten - Teil 1: Betriebsgeräte für Leuchtstofflampen - Messverfahren zur Bestimmung der Gesamteingangsleistung von Betriebsgeräteschaltungen und des Wirkungsgrades von Betriebsgeräten (IEC 62442-1:2022)

Performance énergétique des appareillages de lampes - Partie 1 : Appareillages des lampes à fluorescence - Méthode de mesurage pour la détermination de la puissance d'entrée totale des circuits d'appareillage et du rendement des appareillages (IEC 62442-1:2022)

IEC 62442-1:2022 est disponible sous forme de IEC 62442-1:2022 RLV qui contient la Norme internationale et sa version Redline, illustrant les modifications du contenu technique depuis l'édition précédente.

L'IEC 62442-1:2022 définit une méthode de mesurage et de calcul de la puissance d'entrée totale pour les circuits appareillage-lampe qui fonctionnent avec la ou les lampes à fluorescence qui leur sont associées. La méthode de calcul du rendement des appareillages de lampes est également définie. Le présent document s'applique aux circuits appareillage-lampe électriques constitués exclusivement de l'appareillage et de la ou des lampes. Il s'applique aux alimentations en courant continu jusqu'à 1 000 V et/ou aux alimentations en courant alternatif jusqu'à 1 000 V à 50 Hz ou 60 Hz. Cette troisième édition annule et remplace la deuxième édition parue en 2018. Cette édition constitue une révision technique. Cette édition inclut les modifications techniques majeures suivantes par rapport à l'édition précédente:
- cette édition a été harmonisée avec l'IEC 62442-2 et l'IEC 62442-3;
- des références à l'IEC 63103 ont été ajoutées afin d'appliquer les méthodes de mesurage de la consommation de puissance en mode non actif.
La version française de cette norme n'a pas été soumise au vote.

Energijske lastnosti krmilne naprave sijalke - 1. del: Krmilna naprava za fluorescenčne sijalke - Merilna metoda za ugotavljanje celotne vhodne moči krmilnih vezij in izkoristka krmilne naprave (IEC 62442-1:2022)

Ta del standarda IEC 62442 določa metodo za meritev in izračun celotne vhodne moči krmilnih vezij sijalk, kadar delujejo s fluorescenčnimi sijalkami. Opredeljena je tudi računska metoda za izkoristek krmilne naprave. Ta dokument se uporablja za električna krmilna vezja sijalk, ki jih sestavljajo le krmilna naprava in sijalke. Namenjen je za uporabo z enosmerno napajalno napetostjo do vključno 1000 V in/ali izmenično napajalno napetostjo do vključno 1000 V pri frekvenci 50 Hz ali 60 Hz. OPOMBA: Zahteve za preskušanje posameznih delov krmilne opreme med proizvodnjo niso vključene. Ta dokument določa merilno metodo za skupno vhodno moč in metodo za izračun učinkovitosti krmilnih naprav za vse krmilne naprave, ki se uporabljajo za domačo uporabo in običajne komercialne namene ter delujejo z naslednjimi fluorescenčnimi sijalkami: – fluorescenčne sijalke z dvema vznožkoma (IEC 60081); – fluorescenčne sijalke z enim vznožkom (IEC 60901); – ostale nizkotlačne živosrebrne fluorescenčne sijalke za splošne namene. Ta dokument se ne uporablja za: – krmilno napravo, ki je sestavni del sijalke; – krmiljeno magnetno krmilno napravo z žičnim navitjem.

General Information

Status
Published
Publication Date
04-Apr-2022
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Apr-2022
Due Date
06-Jun-2022
Completion Date
05-Apr-2022

Relations

Buy Standard

Standard
SIST EN IEC 62442-1:2022
English language
23 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN IEC 62442-1:2022
01-maj-2022
Nadomešča:
SIST EN IEC 62442-1:2019
Energijske lastnosti krmilne naprave sijalke - 1. del: Krmilna naprava za
fluorescenčne sijalke - Merilna metoda za ugotavljanje celotne vhodne moči
krmilnih vezij in izkoristka krmilne naprave (IEC 62442-1:2022)

Energy performance of lamp controlgear - Part 1: Controlgear for fluorescent lamps -

Method of measurement to determine the total input power of controlgear circuits and the

efficiency of controlgear (IEC 62442-1:2022)
Energieeffizienz von Lampenbetriebsgeräten - Teil 1: Betriebsgeräte für
Leuchtstofflampen - Messverfahren zur Bestimmung der Gesamteingangsleistung von
Betriebsgeräteschaltungen und des Wirkungsgrades von Betriebsgeräten (IEC 62442-
1:2022)

Performance énergétique des appareillages de lampes - Partie 1 : Appareillages des

lampes à fluorescence - Méthode de mesurage pour la détermination de la puissance

d'entrée totale des circuits d'appareillage et du rendement des appareillages (IEC 62442

-1:2022)
Ta slovenski standard je istoveten z: EN IEC 62442-1:2022
ICS:
29.140.99 Drugi standardi v zvezi z Other standards related to
žarnicami lamps
SIST EN IEC 62442-1:2022 en

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST EN IEC 62442-1:2022
---------------------- Page: 2 ----------------------
SIST EN IEC 62442-1:2022
EUROPEAN STANDARD EN IEC 62442-1
NORME EUROPÉENNE
EUROPÄISCHE NORM March 2022
ICS 29.140.99 Supersedes EN IEC 62442-1:2018 and all of its
amendments and corrigenda (if any)
English Version
Energy performance of lamp controlgear - Part 1: Controlgear for
fluorescent lamps - Method of measurement to determine the
total input power of controlgear circuits and the efficiency of
controlgear
(IEC 62442-1:2022)

Performance énergétique des appareillages de lampes - Energieeffizienz von Lampenbetriebsgeräten - Teil 1:

Partie 1 : Appareillages des lampes à fluorescence - Betriebsgeräte für Leuchtstofflampen - Messverfahren zur

Méthode de mesurage pour la détermination de la Bestimmung der Gesamteingangsleistung von

puissance d'entrée totale des circuits d'appareillage et du Betriebsgeräteschaltungen und des Wirkungsgrades von

rendement des appareillages Betriebsgeräten
(IEC 62442-1:2022) (IEC 62442-1:2022)

This European Standard was approved by CENELEC on 2022-03-16. CENELEC members are bound to comply with the CEN/CENELEC

Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC

Management Centre or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other language made by translation

under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the

same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,

Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the

Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,

Turkey and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels

© 2022 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.

Ref. No. EN IEC 62442-1:2022 E
---------------------- Page: 3 ----------------------
SIST EN IEC 62442-1:2022
EN IEC 62442-1:2022 (E)
European foreword

The text of document 34C/1545/FDIS, future edition 3 of IEC 62442-1, prepared by SC 34C

"Auxiliaries for lamps" of IEC/TC 34 "Lighting" was submitted to the IEC-CENELEC parallel vote and

approved by CENELEC as EN IEC 62442-1:2022.
The following dates are fixed:

• latest date by which the document has to be implemented at national (dop) 2022-12-16

level by publication of an identical national standard or by endorsement

• latest date by which the national standards conflicting with the (dow) 2025-03-16

document have to be withdrawn

This document supersedes EN IEC 62442-1:2018 and all of its amendments and corrigenda (if any).

Attention is drawn to the possibility that some of the elements of this document may be the subject of

patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.

Any feedback and questions on this document should be directed to the users’ national committee. A

complete listing of these bodies can be found on the CENELEC website.
Endorsement notice

The text of the International Standard IEC 62442-1:2022 was approved by CENELEC as a European

Standard without any modification.

In the official version, for Bibliography, the following notes have to be added for the standards

indicated:
IEC 62442-2 NOTE Harmonized as EN IEC 62442-2
IEC 62442-3 NOTE Harmonized as EN IEC 62442-3
---------------------- Page: 4 ----------------------
SIST EN IEC 62442-1:2022
EN IEC 62442-1:2022 (E)
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications

The following documents are referred to in the text in such a way that some or all of their content

constitutes requirements of this document. For dated references, only the edition cited applies. For

undated references, the latest edition of the referenced document (including any amendments)

applies.

NOTE 1 Where an International Publication has been modified by common modifications, indicated by (mod), the

relevant EN/HD applies.

NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available

here: www.cenelec.eu.
Publication Year Title EN/HD Year
IEC 60050-845 - International Electrotechnical Vocabulary - -
(IEV) – Part 845: Lighting
IEC 60081 1997 Double-capped fluorescent lamps - EN 60081 1998
Performance specifications
+ A4 2010 + A4 2010
- - + A11 2018
IEC 60901 1996 Single-capped fluorescent lamps - EN 60901 1996
Performance specifications
+ A5 2011 + A5 2012
IEC 60921 2004 Ballasts for tubular fluorescent lamps - EN 60921 2004
Performance requirements
IEC 60929 2011 AC and/or DC-supplied electronic control EN 60929 2011
gear for tubular fluorescent lamps -
Performance requirements
- - + AC 2011
IEC 63103 2020 Lighting equipment - Non-active mode EN IEC 63103 2020
power measurement
IEC TS 63105 Lighting systems and related equipment - - -
Vocabulary
---------------------- Page: 5 ----------------------
SIST EN IEC 62442-1:2022
---------------------- Page: 6 ----------------------
SIST EN IEC 62442-1:2022
IEC 62442-1
Edition 3.0 2022-02
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Energy performance of lamp controlgear –
Part 1: Controlgear for fluorescent lamps – Method of measurement to
determine the total input power of controlgear circuits and the efficiency of
controlgear
Performance énergétique des appareillages de lampes –
Partie 1: Appareillages des lampes à fluorescence – Méthode de mesurage pour

la détermination de la puissance d'entrée totale des circuits d'appareillage et du

rendement des appareillages
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 29.140.99 ISBN 978-2-8322-1077-0

Warning! Make sure that you obtained this publication from an authorized distributor.

Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.

® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale
---------------------- Page: 7 ----------------------
SIST EN IEC 62442-1:2022
– 2 – IEC 62442-1:2022 © IEC 2022
CONTENTS

FOREWORD ........................................................................................................................... 4

1 Scope .............................................................................................................................. 6

2 Normative references ...................................................................................................... 6

3 Terms and definitions ...................................................................................................... 7

4 General ........................................................................................................................... 9

4.1 Ballast lumen factor ................................................................................................ 9

4.2 Dimmable controlgear ........................................................................................... 10

4.3 Multi-power and/or multi-number-lamp controlgear ................................................ 10

4.4 General notes on tests .......................................................................................... 10

4.5 Sampling of controlgear for testing ........................................................................ 10

4.6 Size of the test sample.......................................................................................... 10

4.7 Conditioning of lamps ........................................................................................... 10

4.8 Test voltages and frequencies .............................................................................. 10

4.9 Sensor and network connections ........................................................................... 11

5 Method of measurement and calculation of total input power of controlgear-lamp

circuits and the efficiency of controlgear ........................................................................ 11

5.1 Correction for ballast lumen factor ........................................................................ 11

5.2 Method of measurement ....................................................................................... 11

5.3 Measurement and calculation of the total input power of magnetic

controlgear-lamp circuits ....................................................................................... 12

5.4 Calculation of the efficiency of electromagnetic controlgear .................................. 12

5.5 Measurement and calculation of the total input power of electronic

controlgear-lamp circuits ....................................................................................... 12

5.6 Calculation of the efficiency of electronic controlgear ............................................ 14

5.7 Measuring the standby power ............................................................................... 14

5.8 Measuring the networked standby power .............................................................. 14

5.9 Reporting of power measurements ........................................................................ 14

Annex A (normative) Energy performance measurement set-up ........................................... 15

A.1 Measurement set-up for electromagnetic controlgear ............................................ 15

A.2 Measurement set-up for electronic controlgear ...................................................... 15

A.2.1 Measurement of the total input power ............................................................ 15

A.2.2 Light output measurement ............................................................................. 16

A.2.3 Distance to lamp related to lamp length: explanations ................................... 17

Annex B (informative) Application of the reference ballast when assessing lamps in

electronic operation .............................................................................................................. 19

B.1 Calculation of the reference ballast impedance ..................................................... 19

B.2 Method of adjusting the lamp power ...................................................................... 19

Bibliography .......................................................................................................................... 20

Figure A.1 – Measurement of electromagnetic controlgear-lamp circuits ............................... 15

Figure A.2 – Measurement of AC supplied electronic controlgear-lamp circuits ..................... 16

Figure A.3 – Side view of light output measurement system .................................................. 16

Figure A.4 – Top view of light output measurement system ................................................... 17

Figure A.5 – Configuration of lamp and photocell sensor ...................................................... 18

---------------------- Page: 8 ----------------------
SIST EN IEC 62442-1:2022
IEC 62442-1:2022 © IEC 2022 – 3 –

Table 1 – Typical nominal electricity supply details for some regions .................................... 11

---------------------- Page: 9 ----------------------
SIST EN IEC 62442-1:2022
– 4 – IEC 62442-1:2022 © IEC 2022
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
ENERGY PERFORMANCE OF LAMP CONTROLGEAR –
Part 1: Controlgear for fluorescent lamps –
Method of measurement to determine the total input power
of controlgear circuits and the efficiency of controlgear
FOREWORD

1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising

all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international

co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and

in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,

Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their

preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with

may participate in this preparatory work. International, governmental and non-governmental organizations liaising

with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for

Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.

2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international

consensus of opinion on the relevant subjects since each technical committee has representation from all

interested IEC National Committees.

3) IEC Publications have the form of recommendations for international use and are accepted by IEC National

Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC

Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any

misinterpretation by any end user.

4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications

transparently to the maximum extent possible in their national and regional publications. Any divergence between

any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.

5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity

assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any

services carried out by independent certification bodies.

6) All users should ensure that they have the latest edition of this publication.

7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and

members of its technical committees and IEC National Committees for any personal injury, property damage or

other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and

expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC

Publications.

8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is

indispensable for the correct application of this publication.

9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent

rights. IEC shall not be held responsible for identifying any or all such patent rights.

IEC 62442-1 has been prepared by subcommittee 34C: Auxiliaries for lamps, of IEC technical

committee 34: Lighting. It is an International Standard.

This third edition cancels and replaces the second edition published in 2018. This edition

constitutes a technical revision.

This edition includes the following significant technical changes with respect to the previous

edition:
a) this edition has been harmonized with IEC 62442-2 and IEC 62442-3;

b) the reference to and use of the measurement methods for non-active power consumption in

accordance with IEC 63103 have been added.
---------------------- Page: 10 ----------------------
SIST EN IEC 62442-1:2022
IEC 62442-1:2022 © IEC 2022 – 5 –
The text of this International Standard is based on the following documents:
Draft Report on voting
34C/1545/FDIS 34C/1548/RVD

Full information on the voting for its approval can be found in the report on voting indicated in

the above table.
The language used for the development of this International Standard is English.

This document was drafted in accordance with ISO/IEC Directives, Part 2, and developed in

accordance with ISO/IEC Directives, Part 1 and ISO/IEC Directives, IEC Supplement, available

at www.iec.ch/members_experts/refdocs. The main document types developed by IEC are

described in greater detail at www.iec.ch/standardsdev/publications.

A list of all parts in the IEC 62442 series, published under the general title Energy performance

of lamp controlgear, can be found on the IEC website.

The committee has decided that the contents of this document will remain unchanged until the

stability date indicated on the IEC website under webstore.iec.ch in the data related to the

specific document. At this date, the document will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
---------------------- Page: 11 ----------------------
SIST EN IEC 62442-1:2022
– 6 – IEC 62442-1:2022 © IEC 2022
ENERGY PERFORMANCE OF LAMP CONTROLGEAR –
Part 1: Controlgear for fluorescent lamps –
Method of measurement to determine the total input power
of controlgear circuits and the efficiency of controlgear
1 Scope

This part of IEC 62442 defines a measurement and calculation method of the total input power

for controlgear-lamp circuits when operating with their associated fluorescent lamp(s). The

calculation method for the efficiency of the lamp controlgear is also defined. This document

applies to electrical controlgear-lamp circuits consisting only of the controlgear and the lamp(s).

It is intended for use on DC supplies up to 1 000 V and/or AC supplies up to 1 000 V at 50 Hz

or 60 Hz.

NOTE Requirements for testing individual controlgear during production are not included.

This document specifies the measurement method for the total input power and the calculation

method of the controlgear efficiency for all controlgear used for domestic and normal

commercial purposes operating with the following fluorescent lamps:
– double-capped fluorescent lamps (IEC 60081);
– single-capped fluorescent lamps (IEC 60901);
– other general purpose low-pressure mercury fluorescent lamps.
This document does not apply to:
– controlgear which form an integral part of the lamp;
– controllable wire-wound magnetic controlgear.
2 Normative references

The following documents are referred to in the text in such a way that some or all of their content

constitutes requirements of this document. For dated references, only the edition cited applies.

For undated references, the latest edition of the referenced document (including any

amendments) applies.

IEC 60050-845, International Electrotechnical Vocabulary (IEV) – Part 845: Lighting (available

at http://www.electropedia.org)
IEC 60081:1997, Double-capped fluorescent lamps – Performance specifications
IEC 60081:1997/AMD4:2010
IEC 60901:1996, Single-capped fluorescent lamps – Performance specifications
IEC 60901:1996/AMD5:2011

IEC 60921:2004, Ballasts for tubular fluorescent lamps – Performance requirements

IEC 60929:2011, AC and/or DC-supplied electronic control gear for tubular fluorescent lamps –

Performance requirements
IEC 63103:2020, Lighting equipment – Non-active mode power measurement
---------------------- Page: 12 ----------------------
SIST EN IEC 62442-1:2022
IEC 62442-1:2022 © IEC 2022 – 7 –
IEC TS 63105, Lighting systems and related equipment – Vocabulary
3 Terms and definitions

For the purposes of this document, the terms and definitions given in IEC 60050-845 and

IEC TS 63105 and the following apply.

ISO and IEC maintain terminological databases for use in standardization at the following

addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http://www.iso.org/obp
3.1
nominal value

suitable approximate quantity value used to designate or identify a component, device or

equipment

Note 1 to entry: To express the "nominal value" of a particular quantity, the term "value" is replaced by the quantity

name; for example, nominal power, nominal voltage, and nominal current.
3.2
rated value

value of a quantity, used for specification purposes, declared by the manufacturer or

responsible vendor and established under standard test conditions

Note 1 to entry: To express the "rated value" of a particular quantity, the term "value" is replaced by the quantity

name; for example, rated power, rated voltage, rated current, and rated temperature.

Note 2 to entry: For the different kinds of operation, rated electrical values are given on the lamp data sheets as:

− rated electrical values under "electrical characteristics", if the lamp is defined for 50 Hz/60 Hz operation only;

− rated electrical values under "electrical characteristics", if the lamp is defined for high frequency (≥ 20 kHz)

operation only;

− rated electrical values and typical electrical values, if the lamp is defined simultaneously for 50 Hz/60 Hz

operation and high frequency operation:

• for 50 Hz/60 Hz operation: rated electrical values under "electrical characteristics", and

• for high frequency operation: rated electrical values under "typical lamp characteristics".

[SOURCE: IEC 60050-845:2020, 845-27-100, modified – The note 2 to entry has been replaced

by a new Note 2 to entry.]
3.3
controlgear

one or more components between the supply and one or more lamps which can serve to

transform the supply voltage, limit the current of the lamp(s) to the required value, provide

starting voltage and preheating current, prevent cold starting, correct power factor or reduce

radio interference
3.4
electromagnetic controlgear
magnetic controlgear

controlgear which by means of inductance, or a combination of inductance and capacitance,

serves mainly to limit the current of the electric lamp(s)

[SOURCE: IEC 60050-845:2020, 845-28-052, modified – The second preferred term has been

added.]
---------------------- Page: 13 ----------------------
SIST EN IEC 62442-1:2022
– 8 – IEC 62442-1:2022 © IEC 2022
3.5
electronic controlgear

AC invertor supplied with alternating current and/or direct current and including stabilizing

elements for starting and operating one or more tubular fluorescent lamps, generally at high

frequency
3.6
fluorescent lamp

discharge lamp of the low pressure mercury type, in which most of the light is emitted by one

or several layers of phosphors excited by the ultra-violet radiation from the discharge

3.7
controlgear-lamp circuit

electrical circuit, or part thereof, normally built in a luminaire, consisting of the controlgear and

lamp(s)
3.8
reference ballast

special ballast, either inductive for lamps for operation on AC mains frequencies, or resistive

for lamps for operation on high frequency

Note 1 to entry: A reference ballast is designed for the purpose of providing comparison standards for use in testing

ballasts, for the selection of reference lamps and for testing regular production lamps under standardized conditions.

It is essentially characterized by the fact that, at its rated frequency, it has a stable voltage/current ratio which is

relatively uninfluenced by variations in current, temperature and magnetic surroundings, as outlined in IEC 60929

and IEC 60921.

Note 2 to entry: Annex B provides details for calculating the reference ballast characteristics and the method of

operation with the reference ballast.
3.9
reference lamp

lamp selected for testing controlgear which, when associated with a reference controlgear, has

electrical characteristics which are close to the rated values or typical lamp characteristics as

stated in the relevant lamp standard
Note 1 to entry: For details regarding the tolerances, see Clause B.2.
3.10
lamp rated power
Lrated

power of a given lamp type specified by the manufacturer or the supplier, the lamp being

operated under specified conditions
Note 1 to entry: The rated power of a lamp is expressed in W.
3.11
ballast lumen factor
BLF

ratio of the light output of the reference lamp when the ballast under test is operated at its rated

voltage, compared with the light output of the same lamp operated with the appropriate

reference ballast supplied at its rated voltage and frequency
3.12
total input power

total power consumed by the controlgear-light source circuit measured at rated input voltage

---------------------- Page: 14 ----------------------
SIST EN IEC 62442-1:2022
IEC 62442-1:2022 © IEC 2022 – 9 –
3.13
controlgear efficiency

ratio of the output power to the lamp(s) and the total input power of the controlgear

Note 1 to entry: Loads from sensors, network connections and other auxiliary are disconnected or, if not possible,

otherwise eliminated from the result.
3.14
multi-power-lamp controlgear
controlgear designed to operate one or more lamp(s) with different rated powers
3.15
multi-number-lamp controlgear
controlgear designed to operate simultaneously more than one similar lamp
3.16
standby mode

mode when the equipment is connected to a supply voltage with the

illumination function off, while capable of being activated by an external trigger not being a

trigger from a network
Note 1 to entry: Examples of external triggers are sensing or timing.

[SOURCE: IEC 63103:2020, 3.10, modified – The domain "" has been

replaced with "".]
3.17
networked standby mode

mode when the equipment is connected to a supply voltage with the

illumination function off, while capable of being activated by an external trigger being a trigger

from a network

[SOURCE: IEC 63103:2020, 3.11, modified – The domain "" has been

replaced with "".]
3.18
standby power
average power consumption in the standby mode
3.19
networked standby power
average power consumption in the networked standby mode
4 General
4.1 Ballast lumen factor

For every controlgear-lamp combination submitted for the test, the ballast lumen factor shall be

measured. The ballast lumen factor is defined in 3.11 and expressed as:
Light
test
BLF=
(1)
Light
ref
---------------------- Page: 15 ----------------------
SIST EN IEC 62442-1:2022
– 10 – IEC 62442-1:2022 © IEC 2022
where

Light is the light output of the reference lamp connected to the reference ballast measured

ref
by photocell meter reading;

Light is the light output of the reference lamp connected to the controlgear under test

test
measured by photocell meter reading.

The ballast lumen factor shall be in the range of 0,925 to 1,075. A controlgear with a lower

ballast lumen factor is not suitable for testing. The upper limit of 1,075 may be exceeded, if the

value for maximum lamp operation current and maximum current in any lead to cathodes comply

with the rated value in IEC 60081 and IEC 60901.
4.2 Dimmable controlgear

A sufficient cathode temperature shall be produced by the heating circuit at any possible

dimming position within the available dimming range of the controlgear as specified in the

relevant data sheet in IEC 60081 and IEC 60901.

Dimmable controlgear shall be measured at 100 % and 25 % lumen output of the operated

lamp(s).
4.3 Multi-power and/or multi-number-lamp controlgear

Multi-power and multi-number-lamp controlgear shall be measured with all the possible lamp

power and number of lamp combinations. The manufacturer shall declare the relevant BLF for

each combination.
4.4 General notes on tests

The measurement conditions specified in IEC 60921:2004 or IEC 60929:2011, Annex A shall

be applie
...

Questions, Comments and Discussion