Space engineering - Guidelines for electrical design and interface requirements for power supply

In general terms, the scope of the consolidation of LCLs power distribution interface requirements in the EN 16603-20-20 (equivalent to ECSS-E-ST-20-20) and the relevant explanation in the present handbook is to allow a more recurrent approach for the specific designs offered by power unit manufacturers, at the benefit of the system integrators and of the Agency, thus ensuring:
- better quality,
- stability of performances, and
- independence of the products from specific mission targets.
A recurrent approach enables power distribution manufacturing companies to concentrate on products and a small step improvement approach that is the basis of a high quality industrial output.
In particular, the scope of the present handbook is:
- to explain the principles of operation of power distribution based on LCLs,
- to identify important issues related to LCLs, and
- to give some explanations of the requirements set up in the ECSS-E-ST-20-20 for power distribution based on LCLs, for both source and load sides.

Raumfahrttechnik - Richtlinen für das elektrische Design und die Schnittstellenanforderungen von Stromversorgunge

Ingénierie spatiale - Règles de design électrique et exigences d’interfaces pour les alimentations de puissanc

Vesoljska tehnika - Smernice za električno načrtovanje in zahteve vmesnikov za napajanje

Na splošno naj bi konsolidacija zahtev za vmesnike za distribucijo električne energije LCL v standardu EN 16603-20-20 (enakovreden dokumentu ECSS-E-ST-20-20) in ustrezna razlaga v tem priročniku omogočili ponavljajoči se pristop za posebno projektiranje, ki ga ponujajo proizvajalci pogonskih enot, v korist sistemskih integratorjev in Agencije, s čimer se zagotovi:
– večja kakovost,
– stabilnost delovanja in
– neodvisnost izdelkov od ciljev posameznih misij.
Ponavljajoči se pristop podjetjem za proizvodnjo električne energije omogoča, da se osredotočijo na izdelke in pristop k izboljšanju z majhnimi koraki, ki je osnova za visokokakovostno industrijsko proizvodnjo.
Področje uporabe tega priročnika vključuje zlasti:
– razlago principov delovanja distribucije električne energije na osnovi LCL,
– prepoznavanje pomembnih vprašanj, povezanih z LCL, in
– nekaj razlag zahtev, določenih v dokumentu ECSS-E-ST-20-20 za distribucijo energije, ki temelji na LCL, tako na strani vira kot obremenitve.

General Information

Status
Published
Public Enquiry End Date
27-Oct-2021
Publication Date
01-Feb-2022
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
31-Jan-2022
Due Date
07-Apr-2022
Completion Date
02-Feb-2022

Buy Standard

Technical report
TP CEN/TR 17603-20-20:2022 - BARVE
English language
77 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Draft
kTP FprCEN/TR 17603-20-20:2021 - BARVE
English language
77 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST-TP CEN/TR 17603-20-20:2022
01-marec-2022
Vesoljska tehnika - Smernice za električno načrtovanje in zahteve vmesnikov za
napajanje
Space engineering - Guidelines for electrical design and interface requirements for
power supply
Raumfahrttechnik - Richtlinen für das elektrische Design und die
Schnittstellenanforderungen von Stromversorgunge
Ingénierie spatiale - Règles de design électrique et exigences d’interfaces pour les
alimentations de puissanc
Ta slovenski standard je istoveten z: CEN/TR 17603-20-20:2022
ICS:
49.140 Vesoljski sistemi in operacije Space systems and
operations
SIST-TP CEN/TR 17603-20-20:2022 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST-TP CEN/TR 17603-20-20:2022

---------------------- Page: 2 ----------------------
SIST-TP CEN/TR 17603-20-20:2022


TECHNICAL REPORT CEN/TR 17603-20-20

RAPPORT TECHNIQUE

TECHNISCHER BERICHT
January 2022
ICS 49.140

English version

Space engineering - Guidelines for electrical design and
interface requirements for power supply
Ingénierie spatiale - Règles de design électrique et Raumfahrttechnik - Richtlinen für das elektrische
exigences d'interfaces pour les alimentations de Design und die Schnittstellenanforderungen von
puissanc Stromversorgunge


This Technical Report was approved by CEN on 29 November 2021. It has been drawn up by the Technical Committee
CEN/CLC/JTC 5.

CEN and CENELEC members are the national standards bodies and national electrotechnical committees of Austria, Belgium,
Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia,
Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
























CEN-CENELEC Management Centre:
Rue de la Science 23, B-1040 Brussels
© 2022 CEN/CENELEC All rights of exploitation in any form and by any means
Ref. No. CEN/TR 17603-20-20:2022 E
reserved worldwide for CEN national Members and for
CENELEC Members.

---------------------- Page: 3 ----------------------
SIST-TP CEN/TR 17603-20-20:2022
CEN/TR 17603-20-20:2022 (E)
Table of contents
European Foreword . 5
Introduction . 6
1 Scope . 7
2 References . 8
3 Terms, definitions and abbreviated terms . 9
3.1 Terms from other documents . 9
3.2 Abbreviated terms. 9
4 Explanations . 11
4.1 Explanatory note . 11
4.2 How to use this document . 11
5 Power distribution by LCLs/RLCLs . 12
5.1 General architecture . 12
5.2 Functionality . 13
Overview . 13
Switch, driver and current sensor . 13
Trip-off section . 15
Memory cell and switch supply section . 18
Undervoltage protection section . 19
Auxiliary supply section . 21
Telemetry section . 21
5.3 Retriggerable Latching Current Limiter case . 22
5.4 Heater Latching Current Limiter case. 23
5.5 Reference power bus specification . 24
5.6 Performance, state of the art . 24
5.7 Critical requirements and important issues . 27
Overview . 27
Nominal conditions (LCL fully operational) . 28
Fault conditions (partially or fully failed LCL) . 51
RLCL specific requirements . 60
2

---------------------- Page: 4 ----------------------
SIST-TP CEN/TR 17603-20-20:2022
CEN/TR 17603-20-20:2022 (E)
Applicable rating/derating rules . 61
Load input filter damping . 63
Annex A LCL generic block diagram . 65
Annex B Generic Power Distribution diagram by LCLs . 66
Annex C LCL timing diagram . 67
Annex D Dragging effect . 68
Annex E LCL Transient Mode Stability Verification . 71
Annex F Reliable RLCL retrigger disable approach . 73
Annex G APEC 2013 paper “MOSFET Gate Open Failure Analysis in Power
Electronics” . 75
Annex H ESPC 2014 paper “Approach to design for stability a system
comprising a non-ideal current source and a generic load” . 76
Annex I ESPC 2014 paper “LCL current control loop stability design” . 77

Figures
Figure 5-1: LCL generic block diagram . 12
Figure 5-2: Switch, driver and current sensor . 14
Figure 5-3: Trip-off section . 15
Figure 5-4: Thermal electrical network equivalence . 16
Figure 5-5: LCL overload timing diagram . 17
Figure 5-6: Comparison between nominal turn ON (right) and overload caused by a
short circuit (left) . 17
Figure 5-7 : Memory cell and switch supply section . 18
Figure 5-8 : Undervoltage protection section . 19
Figure 5-9, UVP timing diagram . 20
Figure 5-10: RLCL overload timing diagram . 22
Figure 5-11: HLCL application . 23
Figure 5-12: LCL overload timing diagram, alternative behaviour . 27
Figure 5-13, Generic power distribution diagram by LCL. . 28
Figure 5-14: Typical start-up current profile of a DC/DC converter attached to a voltage
source and a series switch. . 31
Figure 5-15: Typical start-up current profile of a DC/DC converter attached to a LCL . 31
Figure 5-16: Possible LCL output voltage when input bus voltage is rising . 34
Figure 5-17: LCL current limitation control loop example . 36
Figure 5-18, Stability and time domain transients . 37
3

---------------------- Page: 5 ----------------------
SIST-TP CEN/TR 17603-20-20:2022
CEN/TR 17603-20-20:2022 (E)
Figure 5-19: LCL time domain measurement set-up . 37
Figure 5-20: LCL impedance versus power supply and switch impedance . 38
Figure 5-21: Thermal and electrical behaviour under current limitation mode . 40
Figure 5-22: MFET Thermal impedance, example . 40
Figure 5-23: Electrical and thermal behaviour mismatch under repetitive overload . 41
Figure 5-24: LCL Behaviour under repetitive overload and UVP activation. . 44
Figure 5-25: Complex payload with an internal distribution system . 45
Figure 5-26: LCL followed by a switch . 46
Figure 5-27: Complex load with cascaded LCLs . 47
Figure 5-28: LCL connections. 49
Figure 5-29: Additional switch on power system (LCL) side . 54
Figure 5-30: Additional switch on load side. 54
Figure 5-31: Switch power dissipation in event of D-G short circuit failure . 56
Figure 5-32: Switch voltage drop in event of D-G short circuit failure . 57
Figure 5-33: Maximum safe operating area, example (red arrows indicate power limit in
transient application) . 62

Tables
Table 5-1: Thermal electrical network equivalence . 16
Table 5-2, LCLs, state of the art performances . 24

4

---------------------- Page: 6 ----------------------
SIST-TP CEN/TR 17603-20-20:2022
CEN/TR 17603-20-20:2022 (E)
European Foreword
This document (CEN/TR 17603-20-20:2022) has been prepared by Technical Committee
CEN/CLC/JTC 5 “Space”, the secretariat of which is held by DIN.
It is highlighted that this technical report does not contain any requirement but only collection of data
or descriptions and guidelines about how to organize and perform the work in support of 16603-20.
This Technical report (CEN/TR 17603-20-20:2022) originates from ECSS-E-HB-20-20A.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
This document has been prepared under a mandate given to CEN by the European Commission and
the European Free Trade Association.
This document has been developed to cover specifically space systems and has therefore precedence
over any TR covering the same scope but with a wider domain of applicability (e.g.: aerospace).
5

---------------------- Page: 7 ----------------------
SIST-TP CEN/TR 17603-20-20:2022
CEN/TR 17603-20-20:2022 (E)
Introduction
The power distribution by Latching Current Limiters, or LCLs, has been widely used in almost all
European satellites for some decades as an effective way to achieve a very controlled and reliable load
connection and disconnection from the satellite main bus, including power management in case of
overload and load short circuit failures.
Additionally, power distribution by LCLs minimises inrush current events due to load filters charging
(see section 5.7.2.3), and for this reason effectively allows the reduction of the loads filters themselves.
On the other side power distribution by LCLs has always been matter of “local” discussion and
review, while no attempt has been done so far to collect all the available information in a congruent
and explanatory handbook and to allow a product-oriented specification as presently done with
ECSS-E-ST-20-20.
This handbook complements ECSS-E-ST-20-20, and it is directed at the same time to power system
engineers, who are specifying and procuring units containing LCLs for power distribution and
protection, and to power electronics design engineers, who are in charge of designing and verifying
power distribution by LCLs.
For the system engineers, this document explains the detailed issues at circuit level and the impacts of
the requirements for the design of LCLs.
For design engineers, this document gives insight and understanding on the rationales of the
requirements on their designs.
It is important to notice that the best understanding of the topic of Power Distribution based by LCLs
is achieved by the contextual reading of both the present handbook and the ECSS-E-ST-20-20.
Note that the present issue of the handbook covers electrical design and interface requirements for
power distribution based on Latching Current Limiters only.
Future issues of the present handbook will cover additional power interfaces.
6

---------------------- Page: 8 ----------------------
SIST-TP CEN/TR 17603-20-20:2022
CEN/TR 17603-20-20:2022 (E)
1
Scope
In general terms, the scope of the consolidation of LCLs power distribution interface requirements in
the ECSS-E-ST-20-20 and the relevant explanation in the present handbook is to allow a more
recurrent approach for the specific designs offered by power unit manufacturers, at the benefit of the
system integrators and of the Agency, thus ensuring:
• better quality,
• stability of performances, and
• independence of the products from specific mission targets.
A recurrent approach enables power distribution manufacturing companies to concentrate on
products and a small step improvement approach that is the basis of a high quality industrial output.
In particular, the scope of the present handbook is:
• to explain the principles of operation of power distribution based on LCLs,
• to identify important issues related to LCLs, and
• to give some explanations of the requirements set up in the ECSS-E-ST-20-20 for power
distribution based on LCLs, for both source and load sides.
7

---------------------- Page: 9 ----------------------
SIST-TP CEN/TR 17603-20-20:2022
CEN/TR 17603-20-20:2022 (E)
2
References
EN Reference Reference in text Title
EN 16601-00-01 ECSS-S-ST-00-01 ECSS system - Glossary of terms
EN 16603-20-20 ECSS-E-ST-20-20 Space engineering - Electrical design and interface
requirements for power supply
EN 16602-30-02 ECSS-Q-ST-30-02 Space product assurance - Failure modes, effects
(and criticality) analysis (FMEA/FMECA)
EN 16602-30-11 ECSS-Q-ST-30-11 Space product assurance - Space product assurance,
Derating – EEE components
ESA PSS-02-10 Vol.1 Power standard
Issue 1, Nov. 1992
IEEE CFP13APE-USB MOSFET Gate Open Failure Analysis in Power
(2013) Electronics, IEEE Applied Power Electronics
Conference and Exposition, Long Beach, California,
17-21 March 2013, pp. 189-196 (reported as Annex
G in the present HB)
ESA SP-719 (2014) Approach to design for stability a system
comprising a non-ideal current source and a generic
load, 10th European Space Power Conference,
Noordwijkerhout, The Netherlands, 13-17 May
2014 (reported as Annex H in the present HB)
ESA SP-719 (2014) LCL current control loop stability design, 10th
European Space Power Conference,

Noordwijkerhout, The Netherlands, 13-17 May
2014 (reported as Annex I in the present HB)
8

---------------------- Page: 10 ----------------------
SIST-TP CEN/TR 17603-20-20:2022
CEN/TR 17603-20-20:2022 (E)
3
Terms, definitions and abbreviated terms
3.1 Terms from other documents
a. For the purpose of this document, the terms and definitions from ECSS-S-ST-00-01 apply, in
particular for the following terms:
1. redundancy
2. active redundancy
3. hot redundancy
4. cold redundancy
5. fault
6. fault tolerance
b. For the purpose of this document, the terms and definitions from ECSS-E-ST-20-20 apply.
3.2 Abbreviated terms
For the purpose of this document, the abbreviated terms from ECSS-S-ST-00-01 and the following
apply:
Abbreviation Meaning
A analysis
BJT bipolar junction transistor
EOL end-of-life
ESTEC European Space Technology and Research Centre
I inspection
LCL latching current limiter
MFET MOS field effect transistor
MOS metal oxide semiconductor
OVP overvoltage protection
PCDU power conditioning and distribution unit
PDU power distribution unit
RDSON drain source resistance in on state (for MFET)
RLCL retriggerable LCL
9

---------------------- Page: 11 ----------------------
SIST-TP CEN/TR 17603-20-20:2022
CEN/TR 17603-20-20:2022 (E)
Abbreviation Meaning
RoD review of design
S3R sequential unit switching regulator
SOA safe operating area
SPFF single point failure free
T test
TWTA travelling wave tube amplifier
UVP undervoltage protection
WCA worst case analysis

10

---------------------- Page: 12 ----------------------
SIST-TP CEN/TR 17603-20-20:2022
CEN/TR 17603-20-20:2022 (E)
4
Explanations
4.1 Explanatory note
The present handbook refers to the electrical interface requirements defined in the ECSS-E-ST-20-20.
The ECSS-E-ST-20-20 requirements are referred to in this handbook by using following convention
and are indicated in italic font:
[requirement number] feature - sub-feature.
For example:
Requirement 5.2.3.2.1a.
Clause Heading 3 title = "Current Limitation Section"
Clause Heading 4 title = "Switch element, positions"
 [5.2.3.2.1.a.] Current Limitation Section – Switch element, position
See also, for more information, Annex A of ECSS-E-ST-20-20.
In addition:
• each requirement (i.e. any statement containing a “shall” in the standard) is marked with red
text.
• each recommendation (i.e. any statement containing a “should” in the standard) is marked with
blue text.
Keywords are highlighted in bold. A keyword is a word that either has a special meaning in the
contest of the chapter in which it appears, or highlight a concept.
4.2 How to use this document
For the best utilisation of this document, it is recommended to print it together with the ECSS-E-ST-20-20
and to consult Annex A, Annex B and Annex C separately and at the same time when reading the
document core.
In this way, the discussion and the rationale explanation of each individual requirement are clearer and
there is the minimum risk of misunderstanding.
11

---------------------- Page: 13 ----------------------
R1 R2
SIST-TP CEN/TR 17603-20-20:2022
CEN/TR 17603-20-20:2022 (E)
5
Power distribution by LCLs/RLCLs
5.1 General architecture
A generic architecture for a Latching Current Limiter, or LCL, is shown in Figure 5-1.
Note that the diagram in Figure 5-1 is given only as a reference, without losing generality, and some of
the features thereby reported can be actually realised differently.
Common LCL design alternatives are discussed further in section 5.2.
Without losing in generality, the general architecture is hereby explained for the distribution by LCLs.
For the specific case of Retriggerable Latching Current Limiter, or RLCL, refer to section 5.3.
LCL
S1
Rs
Vbus
Diff.
Amplifier
Current
Sensor
Switch, driver and
Timer
Trip-off
current sensor
section
D1
D2
UVLO
D3
R
OFF
Flip Memory Cell
Undervoltage
Flop
and Switch
section
ON Q1
S Q
Supply

Figure 5-1: LCL generic block diagram
The Latching Current Limiter, or LCL, is a switch-able, latching, retriggerable over-current/overload
protection placed between a power source and the relevant load.
The LCL can be commanded ON and OFF and its status is normally latched by a relevant memory
cell.
12

---------------------- Page: 14 ----------------------
SIST-TP CEN/TR 17603-20-20:2022
CEN/TR 17603-20-20:2022 (E)
Typically, an LCL presents a minimum residual resistance between power input and power output
during nominal operation (i.e. when the switch is commanded closed).
In case of an overload, e.g. when the load current request exceeds a prefixed threshold, the LCL enters
current limitation and a time counter is activated.
If the overload condition persists for a given time duration (called trip-off time), the time counter
commands the LCL OFF.
Normally there should be an external command activation to reset the LCL into its original ON state.
Note that the LCL identifies a function: therefore it is independent from the number of power switches
or MOSFETs used to implement the function itself.
The functionality of the LCL, in relation to the block diagram in Figure 5-1, is detailed in section 5.2.
5.2 Functionality
Overview
The basic elements of an LCL are the following:
• the section containing the switch, the driver and the current sensor,
• the section relevant to the trip-off timer,
• the section relevant to the memory cell and switch supply section,
• the undervoltage protection (UVP) section,
• the auxiliary supply section (not shown in Figure 5-1), and
• the telemetry section.
Each basic element is discussed in a dedicated section in the present chapter.
Switch, driver and current sensor
The switch is generally constituted by an enhancement MFET, either P or N channel, even though
other devices could be used (for example, bipolar transistors for lower current applications).
It is called “switch” in relation to the switching capability of the LCL (e.g. it can apply or remove
power from the load), but actually it operates either in ohmic “ON” mode or in linear mode according
to the load current being below or above a specified threshold.
13

---------------------- Page: 15 ----------------------
R1 R2
SIST-TP CEN/TR 17603-20-20:2022
CEN/TR 17603-20-20:2022 (E)
S1
Rs
Vbus
Diff.
Amplifier
Current
Sensor
Switch, driver and
Trip-off
Timer
current sensor
section
D1
D2
UVLO
D3
R
OFF
Flip Memory Cell
Undervoltage
Flop
and Switch
section ON Q1
S Q
Supply

Figure 5-2: Switch, driver and current sensor
It is to point out that the switch and the current sensing resistor (or sensing element), is not placed on
the power line connected to ground: this is a mandatory feature if the LCL power output is
distributed outside the unit containing the LCL itself (as it happens on the main bus protected outputs
in the power system Distribution Unit or PDU). The reason is that the power output lines need to be
protected versus accidental short circuit to ground due to failures in the connectors, in the harness, or
in the supplied load.
[5.2.3.2.1.a] Current limitation section – Switch element, position
[5.2.3.3.1.a] Current limitation section – Current sensing element, position
The relevant switch driver is usually inherently included in the same circuit implementing the current
sensing feature: when the LCL is commanded ON, the switch is normally in ohmic “ON” mode and
presents either a low ohmic characteristic (for MFETs, ON channel resistance, or RDSON) or anyhow a
low voltage drop (as in the case of a BJT switch).
[5.4.5.1.1.a], [5.4.5.1.1.b], [5.4.5.1.1.c] Voltage drop – Voltage drop
In case of an overload, it is necessary that the switch is quickly brought outside ohmic “ON” mode
condition and into linear one, in order to reduce the relevant surge current conditions (causing also
relevant system EMC conducted and radiated disturbances) and the switch power/thermal stress.
The speed of response is function of the MFET gate charge and it is a figure of merit of the current
sensing circuit.
[5.4.1.1.1.a], [5.4.1.1.1.b], [5.4.1.1.1.c], [5.4.1.1.1.d], [5.4.1.1.1.e], [5.4.1.1.1.f] Overall requirements - Current
overshoot
The current sensor is in charge of regulating the current in overload situation, by modulating the gate
voltage of the switch: the accuracy of the gate voltage is function of the current sensing circuit and the
relevant reference voltages used in the design.
[5.2.1.1.1.a], [5.2.1.1.1.b] HLCL/LCL class – HLCL/LCL class
[5.2.2.1.1.a] RLCL class – RLCL class
[5.2.3.1.1.a] Current limitation section - Range
In case more than one MOSFET is used, it is important to have a dedicated current control per
MOSFET to ensure current sharing in limitation.
14

---------------------- Page: 16 ----------------------
R1 R2
SIST-TP CEN/TR 17603-20-20:2022
CEN/TR 17603-20-20:2022 (E)
If two or more MOSFETs are used in parallel with one single limiter, each MOSFET should be able to
handle the total limitation current.
The current sensor is also sometimes used to derive a current telemetry signal, which is normally
referred to ground.
An important observation is that the LCL/RLCL needs to contain a provision to circulate (free-wheel)
the current circulating in the load (or harness) inductance, when the LCL/RLCL is either commanded
OFF or it opens the line after an overload.
This is normally achieved by placing an anti-parallel diode to the output of the LCL itself.
[5.2.7.7.1.a] Conditions at start-up/switch-off – switch-off
Trip-off section
Overview
The LCL trip-off section is in charge to start the “counting” of the overload condition duration, and to
set the LCL status to OFF after the relevant trip-off time has elapsed.
S1
Rs
Vbus
Diff.
Amplifier
Current
Sensor
Switch, driver and
Trip-off
Timer current sense
section
D1
D2
UVLO
D3
R
OFF
Flip Memory Cell
Undervoltage
Flop
and Switch
section ON Q1
S Q
Supply

Figure 5-3: Trip-off section
[5.2.1.1.1.a], [5.2.1.1.1.b] LCL/HLCL class – LCL/HLCL class
NOTE Specifically minimum and maximum trip-off time.
[5.2.2.1.1.a] RLCL class – RLCL class
NOTE Specifically minimum and maximum trip-off time.
[5.2.4.1.1.a] Trip-OFF section - Range
It can be triggered by a signal coming from the current sense section, which identifies that the current
limitation has been entered as a consequence of an overload, or by the differential reading of the
voltage across the switch (as shown in Figure 5-1).
When the differential voltage across the switch is over a prefixed threshold, a timer is started to count
the trip-off time.
The timer is usually implemented by means of a simple resistive-capacitive (RC) element in
combination with a comparator, or a digital counter/comparator.
If the timer is implemented by a RC low-pass filter, the voltage across the capacitor mimics the
temperature developed at the junction of the LCL MFET switch under current limiting conditions.
15

---------------------- Page: 17 ----------------------
SIST-TP CEN/TR 17603-20-20:2022
CEN/TR 17603-20-20:2022 (E)
To understand this concept, it is useful to think of the electrical equivalence of a thermal network (see
following Table 5-1 and Figure 5-4).
Table 5-1: Thermal electrical network equivalence
Electrical domain
Thermal domain
Current A Power W
Voltage V Temperature °C
Resistance Ohm Thermal Resistance °C/W
Capacity F Thermal Capacity J/°C

ELECTRICAL THERMAL
DOMAIN DOMAIN
Equivalence
Vsource Tsource
Isource Psource
I P
V V
1 2 T T
1 2
R Rth
I P
V V
3 4 T T
3 4
C Cth

Figure 5-4: Thermal electrical network equivalence
When the timer predefined trip-off time duration is elapsed, the LCL is switched OFF.
A time diagram illustrating the qualitative current profile of an overload event is shown in Figure 5-5.
We can identify two different modes of operation for the current limitation:
a. the first current limitation mode occurs when an LCL is enabled with a command and then
starts to charge the input filter capacitance in the load (Figure 5-6, right). In this case a negligible
overshoot in the current profile can be expected and achieved.
b. the second case (Figure 5-6, left) is when the LCL is enabled and a sudden overload like a short
circuit occurs (in this case, a larger current overshoot can occur).
16

---------------------- Page: 18 ----------------------
SIST-TP CEN/TR 17603-20-20:2022
CEN/TR 17603-20-20:2022 (E)
The specification and understanding of these two cases are important to clarify when compatibility
tests and analyses are made on real hardware at equipment level.
Curre nt Ove rshoot De cay
Time
Time to Curre nt
Overshoot
Current
Overshoot
Excess
Current
±10% of
Excess
Current
Max
Limitation
Actual
Current
{
Min
Max
Nom
...

SLOVENSKI STANDARD
kSIST-TP FprCEN/TR 17603-20-20:2021
01-oktober-2021
Vesoljska tehnika - Smernice za električno načrtovanje in zahteve vmesnikov za
napajanje
Space engineering - Guidelines for electrical design and interface requirements for
power supply
Raumfahrttechnik - Richtlinien für die elektrische Konstruktion und
Schnittstellenanforderungen für die Stromversorgung
Ta slovenski standard je istoveten z: FprCEN/TR 17603-20-20
ICS:
49.140 Vesoljski sistemi in operacije Space systems and
operations
kSIST-TP FprCEN/TR 17603-20-20:2021 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
kSIST-TP FprCEN/TR 17603-20-20:2021

---------------------- Page: 2 ----------------------
kSIST-TP FprCEN/TR 17603-20-20:2021


TECHNICAL REPORT
FINAL DRAFT
FprCEN/TR 17603-20-20
RAPPORT TECHNIQUE

TECHNISCHER BERICHT

August 2021
ICS 49.140

English version

Space engineering - Guidelines for electrical design and
interface requirements for power supply
 Raumfahrttechnik - Richtlinien für die elektrische
Konstruktion und Schnittstellenanforderungen für die
Stromversorgung


This draft Technical Report is submitted to CEN members for Vote. It has been drawn up by the Technical Committee
CEN/CLC/JTC 5.

CEN and CENELEC members are the national standards bodies and national electrotechnical committees of Austria, Belgium,
Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia,
Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.

Warning : This document is not a Technical Report. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a Technical Report.





















CEN-CENELEC Management Centre:
Rue de la Science 23, B-1040 Brussels
© 2021 CEN/CENELEC All rights of exploitation in any form and by any means Ref. No. FprCEN/TR 17603-20-20:2021 E
reserved worldwide for CEN national Members and for
CENELEC Members.

---------------------- Page: 3 ----------------------
kSIST-TP FprCEN/TR 17603-20-20:2021
FprCEN/TR 17603-20-20:2021 (E)
Table of contents
European Foreword . 5
Introduction . 6
1 Scope . 7
2 References . 8
3 Terms, definitions and abbreviated terms . 9
3.1 Terms from other documents . 9
3.2 Abbreviated terms. 9
4 Explanations . 11
4.1 Explanatory note . 11
4.2 How to use this document . 11
5 Power distribution by LCLs/RLCLs . 12
5.1 General architecture . 12
5.2 Functionality . 13
5.2.1 Overview . 13
5.2.2 Switch, driver and current sensor . 13
5.2.3 Trip-off section . 15
5.2.4 Memory cell and switch supply section . 18
5.2.5 Undervoltage protection section . 19
5.2.6 Auxiliary supply section . 21
5.2.7 Telemetry section . 21
5.3 Retriggerable Latching Current Limiter case . 22
5.4 Heater Latching Current Limiter case. 23
5.5 Reference power bus specification . 24
5.6 Performance, state of the art . 24
5.7 Critical requirements and important issues . 28
5.7.1 Overview . 28
5.7.2 Nominal conditions (LCL fully operational) . 28
5.7.3 Fault conditions (partially or fully failed LCL) . 51
5.7.4 RLCL specific requirements . 60
2

---------------------- Page: 4 ----------------------
kSIST-TP FprCEN/TR 17603-20-20:2021
FprCEN/TR 17603-20-20:2021 (E)
5.7.5 Applicable rating/derating rules . 61
5.7.6 Load input filter damping . 63
Annex A LCL generic block diagram . 65
Annex B Generic Power Distribution diagram by LCLs . 66
Annex C LCL timing diagram . 67
Annex D Dragging effect . 68
Annex E LCL Transient Mode Stability Verification . 71
Annex F Reliable RLCL retrigger disable approach . 73
Annex G APEC 2013 paper “MOSFET Gate Open Failure Analysis in Power
Electronics” . 75
Annex H ESPC 2014 paper “Approach to design for stability a system
comprising a non-ideal current source and a generic load” . 76
Annex I ESPC 2014 paper “LCL current control loop stability design” . 77

Figures
Figure 5-1: LCL generic block diagram . 12
Figure 5-2: Switch, driver and current sensor . 14
Figure 5-3: Trip-off section . 15
Figure 5-4: Thermal electrical network equivalence . 16
Figure 5-5: LCL overload timing diagram . 17
Figure 5-6: Comparison between nominal turn ON (right) and overload caused by a
short circuit (left) . 17
Figure 5-7 : Memory cell and switch supply section . 18
Figure 5-8 : Undervoltage protection section . 19
Figure 5-9, UVP timing diagram . 20
Figure 5-10: RLCL overload timing diagram . 22
Figure 5-11: HLCL application . 23
Figure 5-12: LCL overload timing diagram, alternative behaviour . 27
Figure 5-13, Generic power distribution diagram by LCL. . 28
Figure 5-14: Typical start-up current profile of a DC/DC converter attached to a voltage
source and a series switch. . 31
Figure 5-15: Typical start-up current profile of a DC/DC converter attached to a LCL . 31
Figure 5-16: Possible LCL output voltage when input bus voltage is rising . 34
Figure 5-17: LCL current limitation control loop example . 36
Figure 5-18, Stability and time domain transients . 37
3

---------------------- Page: 5 ----------------------
kSIST-TP FprCEN/TR 17603-20-20:2021
FprCEN/TR 17603-20-20:2021 (E)
Figure 5-19: LCL time domain measurement set-up . 37
Figure 5-20: LCL impedance versus power supply and switch impedance . 38
Figure 5-21: Thermal and electrical behaviour under current limitation mode . 40
Figure 5-22: MFET Thermal impedance, example . 40
Figure 5-23: Electrical and thermal behaviour mismatch under repetitive overload . 41
Figure 5-24: LCL Behaviour under repetitive overload and UVP activation. . 44
Figure 5-25: Complex payload with an internal distribution system . 45
Figure 5-26: LCL followed by a switch . 46
Figure 5-27: Complex load with cascaded LCLs . 47
Figure 5-28: LCL connections. 49
Figure 5-29: Additional switch on power system (LCL) side . 54
Figure 5-30: Additional switch on load side. 54
Figure 5-31: Switch power dissipation in event of D-G short circuit failure . 56
Figure 5-32: Switch voltage drop in event of D-G short circuit failure . 57
Figure 5-33: Maximum safe operating area, example (red arrows indicate power limit in
transient application) . 62

Tables
Table 5-1: Thermal electrical network equivalence . 16
Table 5-2, LCLs, state of the art performances . 25

4

---------------------- Page: 6 ----------------------
kSIST-TP FprCEN/TR 17603-20-20:2021
FprCEN/TR 17603-20-20:2021 (E)
European Foreword
This document (FprCEN/TR 17603-20-20:2021) has been prepared by Technical Committee
CEN/CLC/JTC 5 “Space”, the secretariat of which is held by DIN.
It is highlighted that this technical report does not contain any requirement but only collection of data
or descriptions and guidelines about how to organize and perform the work in support of 16603-20.
This Technical report (FprCEN/TR 17603-20-20:2021) originates from ECSS-Q-HB-20-20A.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such
patent rights.
This document has been prepared under a mandate given to CEN by the European Commission and
the European Free Trade Association.
This document has been developed to cover specifically space systems and has therefore precedence
over any TR covering the same scope but with a wider domain of applicability (e.g.: aerospace).

This document is currently submitted to the CEN CONSULTATION.
5

---------------------- Page: 7 ----------------------
kSIST-TP FprCEN/TR 17603-20-20:2021
FprCEN/TR 17603-20-20:2021 (E)
Introduction
The power distribution by Latching Current Limiters, or LCLs, has been widely used in almost all
European satellites for some decades as an effective way to achieve a very controlled and reliable load
connection and disconnection from the satellite main bus, including power management in case of
overload and load short circuit failures.
Additionally, power distribution by LCLs minimises inrush current events due to load filters charging
(see section 5.7.2.3), and for this reason effectively allows the reduction of the loads filters themselves.
On the other side power distribution by LCLs has always been matter of “local” discussion and
review, while no attempt has been done so far to collect all the available information in a congruent
and explanatory handbook and to allow a product-oriented specification as presently done with
ECSS-E-ST-20-20.
This handbook complements ECSS-E-ST-20-20, and it is directed at the same time to power system
engineers, who are specifying and procuring units containing LCLs for power distribution and
protection, and to power electronics design engineers, who are in charge of designing and verifying
power distribution by LCLs.
For the system engineers, this document explains the detailed issues at circuit level and the impacts of
the requirements for the design of LCLs.
For design engineers, this document gives insight and understanding on the rationales of the
requirements on their designs.
It is important to notice that the best understanding of the topic of Power Distribution based by LCLs
is achieved by the contextual reading of both the present handbook and the ECSS-E-ST-20-20.
Note that the present issue of the handbook covers electrical design and interface requirements for
power distribution based on Latching Current Limiters only.
Future issues of the present handbook will cover additional power interfaces.
6

---------------------- Page: 8 ----------------------
kSIST-TP FprCEN/TR 17603-20-20:2021
FprCEN/TR 17603-20-20:2021 (E)
1
Scope
In general terms, the scope of the consolidation of LCLs power distribution interface requirements in
the ECSS-E-ST-20-20 and the relevant explanation in the present handbook is to allow a more
recurrent approach for the specific designs offered by power unit manufacturers, at the benefit of the
system integrators and of the Agency, thus ensuring:
 better quality,
 stability of performances, and
 independence of the products from specific mission targets.
A recurrent approach enables power distribution manufacturing companies to concentrate on
products and a small step improvement approach that is the basis of a high quality industrial output.
In particular, the scope of the present handbook is:
 to explain the principles of operation of power distribution based on LCLs,
 to identify important issues related to LCLs, and
 to give some explanations of the requirements set up in the ECSS-E-ST-20-20 for power
distribution based on LCLs, for both source and load sides.
7

---------------------- Page: 9 ----------------------
kSIST-TP FprCEN/TR 17603-20-20:2021
FprCEN/TR 17603-20-20:2021 (E)
2
References
EN Reference Reference in text Title
EN 16601-00-01 ECSS-S-ST-00-01 ECSS system - Glossary of terms
EN 17603-20-20 ECSS-E-ST-20-20 Space engineering - Electrical design and
interface requirements for power supply
EN 16602-30-02 ECSS‐Q‐ST‐30‐02 Space product assurance - Failure modes, effects
(and criticality) analysis (FMEA/FMECA)
EN 16602-30-11 ECSS-Q-ST-30-11 Space product assurance - Space product
assurance, Derating – EEE components
ESA PSS-02-10 Vol.1 Power standard
Issue 1, Nov. 1992
IEEE CFP13APE-USB MOSFET Gate Open Failure Analysis in Power
(2013) Electronics, IEEE Applied Power Electronics
Conference and Exposition, Long Beach,
California, 17-21 March 2013, pp. 189-196
(reported as Annex G in the present HB)
ESA SP‐719 (2014) Approach to design for stability a system
comprising a non-ideal current source and a
generic load, 10th European Space Power
Conference, Noordwijkerhout, The Netherlands,
13-17 May 2014 (reported as Annex H in the
present HB)
ESA SP‐719 (2014) LCL current control loop stability design, 10th
European Space Power Conference,

Noordwijkerhout, The Netherlands, 13-17 May
2014 (reported as Annex I in the present HB)
8

---------------------- Page: 10 ----------------------
kSIST-TP FprCEN/TR 17603-20-20:2021
FprCEN/TR 17603-20-20:2021 (E)
3
Terms, definitions and abbreviated terms
3.1 Terms from other documents
a. For the purpose of this document, the terms and definitions from ECSS-S-ST-00-01 apply, in
particular for the following terms:
1. redundancy
2. active redundancy
3. hot redundancy
4. cold redundancy
5. fault
6. fault tolerance
b. For the purpose of this document, the terms and definitions from ECSS-E-ST-20-20 apply.
3.2 Abbreviated terms
For the purpose of this document, the abbreviated terms from ECSS-S-ST-00-01 and the following
apply:
Abbreviation Meaning
A analysis
BJT bipolar junction transistor
EOL end-of-life
ESTEC European Space Technology and Research Centre
I inspection
LCL latching current limiter
MFET MOS field effect transistor
MOS metal oxide semiconductor
OVP overvoltage protection
PCDU power conditioning and distribution unit
PDU power distribution unit
RDSON drain source resistance in on state (for MFET)
RLCL retriggerable LCL
9

---------------------- Page: 11 ----------------------
kSIST-TP FprCEN/TR 17603-20-20:2021
FprCEN/TR 17603-20-20:2021 (E)
Abbreviation Meaning
RoD review of design
S3R sequential unit switching regulator
SOA safe operating area
SPFF single point failure free
T test
TWTA travelling wave tube amplifier
UVP undervoltage protection
WCA worst case analysis

10

---------------------- Page: 12 ----------------------
kSIST-TP FprCEN/TR 17603-20-20:2021
FprCEN/TR 17603-20-20:2021 (E)
4
Explanations
4.1 Explanatory note
The present handbook refers to the electrical interface requirements defined in the ECSS-E-ST-20-20.
The ECSS-E-ST-20-20 requirements are referred to in this handbook by using following convention
and are indicated in italic font:
[requirement number] feature - sub-feature.
For example:
Requirement 5.2.3.2.1a.
Clause Heading 3 title = "Current Limitation Section"
Clause Heading 4 title = "Switch element, positions"
 [5.2.3.2.1.a.] Current Limitation Section – Switch element, position
See also, for more information, Annex A of ECSS-E-ST-20-20.
In addition:
 each requirement (i.e. any statement containing a “shall” in the standard) is marked with red
text.
 each recommendation (i.e. any statement containing a “should” in the standard) is marked with
blue text.
Keywords are highlighted in bold. A keyword is a word that either has a special meaning in the
contest of the chapter in which it appears, or highlight a concept.
4.2 How to use this document
For the best utilisation of this document, it is recommended to print it together with the ECSS-E-ST-20-20
and to consult Annex A, Annex B and Annex C separately and at the same time when reading the
document core.
In this way, the discussion and the rationale explanation of each individual requirement are clearer and
there is the minimum risk of misunderstanding.
11

---------------------- Page: 13 ----------------------
R1 R2
kSIST-TP FprCEN/TR 17603-20-20:2021
FprCEN/TR 17603-20-20:2021 (E)
5
Power distribution by LCLs/RLCLs
5.1 General architecture
A generic architecture for a Latching Current Limiter, or LCL, is shown in Figure 5-1.
Note that the diagram in Figure 5-1 is given only as a reference, without losing generality, and some of
the features thereby reported can be actually realised differently.
Common LCL design alternatives are discussed further in section 5.2.
Without losing in generality, the general architecture is hereby explained for the distribution by LCLs.
For the specific case of Retriggerable Latching Current Limiter, or RLCL, refer to section 5.3.
LCL
S1
Rs
Vbus
Diff.
Amplifier
Current
Sensor
Switch, driver and
Timer
Trip-off
current sensor
section
D1
D2
UVLO
D3
R
OFF
Flip Memory Cell
Undervoltage
Flop
and Switch
section
ON Q1
S Q
Supply

Figure 5-1: LCL generic block diagram
The Latching Current Limiter, or LCL, is a switch-able, latching, retriggerable over-current/overload
protection placed between a power source and the relevant load.
The LCL can be commanded ON and OFF and its status is normally latched by a relevant memory
cell.
12

---------------------- Page: 14 ----------------------
kSIST-TP FprCEN/TR 17603-20-20:2021
FprCEN/TR 17603-20-20:2021 (E)
Typically, an LCL presents a minimum residual resistance between power input and power output
during nominal operation (i.e. when the switch is commanded closed).
In case of an overload, e.g. when the load current request exceeds a prefixed threshold, the LCL enters
current limitation and a time counter is activated.
If the overload condition persists for a given time duration (called trip-off time), the time counter
commands the LCL OFF.
Normally there should be an external command activation to reset the LCL into its original ON state.
Note that the LCL identifies a function: therefore it is independent from the number of power switches
or MOSFETs used to implement the function itself.
The functionality of the LCL, in relation to the block diagram in Figure 5-1, is detailed in section 5.2.
5.2 Functionality
5.2.1 Overview
The basic elements of an LCL are the following:
 the section containing the switch, the driver and the current sensor,
 the section relevant to the trip-off timer,
 the section relevant to the memory cell and switch supply section,
 the undervoltage protection (UVP) section,
 the auxiliary supply section (not shown in Figure 5-1), and
 the telemetry section.
Each basic element is discussed in a dedicated section in the present chapter.
5.2.2 Switch, driver and current sensor
The switch is generally constituted by an enhancement MFET, either P or N channel, even though
other devices could be used (for example, bipolar transistors for lower current applications).
It is called “switch” in relation to the switching capability of the LCL (e.g. it can apply or remove
power from the load), but actually it operates either in ohmic “ON” mode or in linear mode according
to the load current being below or above a specified threshold.
13

---------------------- Page: 15 ----------------------
R1 R2
kSIST-TP FprCEN/TR 17603-20-20:2021
FprCEN/TR 17603-20-20:2021 (E)
S1
Rs
Vbus
Diff.
Amplifier
Current
Sensor
Switch, driver and
Trip-off
Timer
current sensor
section
D1
D2
UVLO
D3
R
OFF
Flip Memory Cell
Undervoltage
Flop
and Switch
section ON Q1
S Q
Supply

Figure 5-2: Switch, driver and current sensor
It is to point out that the switch and the current sensing resistor (or sensing element), is not placed on
the power line connected to ground: this is a mandatory feature if the LCL power output is
distributed outside the unit containing the LCL itself (as it happens on the main bus protected outputs
in the power system Distribution Unit or PDU). The reason is that the power output lines need to be
protected versus accidental short circuit to ground due to failures in the connectors, in the harness, or
in the supplied load.
[5.2.3.2.1.a] Current limitation section – Switch element, position
[5.2.3.3.1.a] Current limitation section – Current sensing element, position
The relevant switch driver is usually inherently included in the same circuit implementing the current
sensing feature: when the LCL is commanded ON, the switch is normally in ohmic “ON” mode and
presents either a low ohmic characteristic (for MFETs, ON channel resistance, or RDSON) or anyhow a
low voltage drop (as in the case of a BJT switch).
[5.4.5.1.1.a], [5.4.5.1.1.b], [5.4.5.1.1.c] Voltage drop – Voltage drop
In case of an overload, it is necessary that the switch is quickly brought outside ohmic “ON” mode
condition and into linear one, in order to reduce the relevant surge current conditions (causing also
relevant system EMC conducted and radiated disturbances) and the switch power/thermal stress.
The speed of response is function of the MFET gate charge and it is a figure of merit of the current
sensing circuit.
[5.4.1.1.1.a], [5.4.1.1.1.b], [5.4.1.1.1.c], [5.4.1.1.1.d], [5.4.1.1.1.e], [5.4.1.1.1.f] Overall requirements - Current
overshoot
The current sensor is in charge of regulating the current in overload situation, by modulating the gate
voltage of the switch: the accuracy of the gate voltage is function of the current sensing circuit and the
relevant reference voltages used in the design.
[5.2.1.1.1.a], [5.2.1.1.1.b] HLCL/LCL class – HLCL/LCL class
[5.2.2.1.1.a] RLCL class – RLCL class
[5.2.3.1.1.a] Current limitation section - Range
In case more than one MOSFET is used, it is important to have a dedicated current control per
MOSFET to ensure current sharing in limitation.
14

---------------------- Page: 16 ----------------------
R1 R2
kSIST-TP FprCEN/TR 17603-20-20:2021
FprCEN/TR 17603-20-20:2021 (E)
If two or more MOSFETs are used in parallel with one single limiter, each MOSFET should be able to
handle the total limitation current.
The current sensor is also sometimes used to derive a current telemetry signal, which is normally
referred to ground.
An important observation is that the LCL/RLCL needs to contain a provision to circulate (free-wheel)
the current circulating in the load (or harness) inductance, when the LCL/RLCL is either commanded
OFF or it opens the line after an overload.
This is normally achieved by placing an anti-parallel diode to the output of the LCL itself.
[5.2.7.7.1.a] Conditions at start-up/switch-off – switch-off
5.2.3 Trip-off section
5.2.3.1 Overview
The LCL trip-off section is in charge to start the “counting” of the overload condition duration, and to
set the LCL status to OFF after the relevant trip-off time has elapsed.
S1
Rs
Vbus
Diff.
Amplifier
Current
Sensor
Switch, driver and
Trip-off
Timer current sense
section
D1
D2
UVLO
D3
R
OFF
Flip Memory Cell
Undervoltage
Flop
and Switch
section ON Q1
S Q
Supply

Figure 5-3: Trip-off section
[5.2.1.1.1.a], [5.2.1.1.1.b] LCL/HLCL class – LCL/HLCL class
NOTE Specifically minimum and maximum trip-off time.
[5.2.2.1.1.a] RLCL class – RLCL class
NOTE Specifically minimum and maximum trip-off time.
[5.2.4.1.1.a] Trip-OFF section - Range
It can be triggered by a signal coming from the current sense section, which identifies that the current
limitation has been entered as a consequence of an overload, or by the differential reading of the
voltage across the switch (as shown in Figure 5-1).
When the differential voltage across the switch is over a prefixed threshold, a timer is started to count
the trip-off time.
The timer is usually implemented by means of a simple resistive-capacitive (RC) element in
combination with a comparator, or a digital counter/comparator.
If the timer is implemented by a RC low-pass filter, the voltage across the capacitor mimics the
temperature developed at the junction of the LCL MFET switch under current limiting conditions.
15

---------------------- Page: 17 ----------------------
kSIST-TP FprCEN/TR 17603-20-20:2021
FprCEN/TR 17603-20-20:2021 (E)
To understand this concept, it is useful to think of the electrical equivalence of a thermal network (see
following Table 5-1 and Figure 5-4).
Table 5-1: Thermal electrical network equivalence
Electrical domain
Thermal domain
Current A Power W
Voltage V Temperature °C
Resistance Ohm Thermal Resistance °C/W
Capacity F Thermal Capacity J/°C

ELECTRICAL THERMAL
DOMAIN DOMAIN
Equivalence
Vsource Tsource
Isource Psource
I P
V V
1 2 T T
1 2
R Rth
I P
V V
3 4 T T
3 4
C Cth

Figure 5-4: Thermal electrical network equivalence
When the timer predefined trip-off time duration is elapsed, the LCL is switched OFF.
A time diagram illustrating the qualitative current profile of an overload event is shown in Figure 5-5.
We can identify two different modes of operation for the current limitation:
a. the first current limitation mode occurs when an LCL is enabled with a command and then
starts to charge the input filter capacitance in the load (Figure 5-6, right). In this case a negligible
overshoot in the current profile can be expected and achieved.
b. the second case (Figure 5-6, left) is when the LCL is enabled and a sudden overload like a short
circuit occurs (in this case, a larger current oversh
...