Guide to use of low voltage harmonized cables

This HD provides a guide to the proposed  safe use of harmonised electric cables as  presently covered in the various parts of  HD 21 and HD 22. These cables should  only be used within the limits given and in  the manner described in this HD. This HD  should be read in conjunction with other  HDs or ENs relating to particular types of  equipment or installation conditions.  Legal or statutory requirements do take  precedence over the guidance given in  this document.

Leitfaden für die Verwendung harmonisierter Niederspannungsstarkstromleitungen

Guide d'emploi des câbles harmonisés à basse tension

Vodilo za uporabo nizkonapetostnih harmoniziranih kablov

General Information

Status
Withdrawn
Publication Date
11-Feb-2009
Withdrawal Date
18-Oct-2021
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
19-Oct-2021
Due Date
11-Nov-2021
Completion Date
19-Oct-2021

Relations

Buy Standard

Amendment
HD 516 S2:1999/A2:2009
English language
8 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST HD 516 S2:1999/A2:2009
01-marec-2009
Vodilo za uporabo nizkonapetostnih harmoniziranih kablov
Guide to use of low voltage harmonized cables
Leitfaden für die Verwendung harmonisierter Niederspannungsstarkstromleitungen
Guide d'emploi des câbles harmonisés à basse tension
Ta slovenski standard je istoveten z: HD 516 S2:1997/A2:2008
ICS:
29.060.20 Kabli Cables
SIST HD 516 S2:1999/A2:2009 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST HD 516 S2:1999/A2:2009

---------------------- Page: 2 ----------------------

SIST HD 516 S2:1999/A2:2009

HARMONIZATION DOCUMENT
HD 516 S2/A2

DOCUMENT D'HARMONISATION
October 2008
HARMONISIERUNGSDOKUMENT

ICS 29.060.20


English version


Guide to use of low voltage harmonized cables



Guide d'emploi des câbles  Leitfaden für die Verwendung
harmonisés à basse tension harmonisierter
Niederspannungsstarkstromleitungen





This amendment A2 modifies the Harmonization Document HD 516 S2:1997; it was approved by CENELEC
on 2008-09-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for implementation of this amendment at national level.

Up-to-date lists and bibliographical references concerning such national implementations may be obtained
on application to the Central Secretariat or to any CENELEC member.

This amendment exists in three official versions (English, French, German).

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia,
Slovenia, Spain, Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels


© 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. HD 516 S2:1997/A2:2008 E

---------------------- Page: 3 ----------------------

SIST HD 516 S2:1999/A2:2009
HD 516 S2:1997/A2:2008 – 2 –
Foreword

This amendment to Harmonization Document HD 516 S2:1997 was prepared by the Technical
Committee CENELEC TC 20, Electric cables.

The text of the draft was submitted to the Unique Acceptance Procedure and was approved by
CENELEC as amendment A2 to HD 516 S2:1997 on 2008-09-01.

The following dates were fixed:

– latest date by which the existence of the amendment
has to be announced at national level (doa) 2009-03-01
– latest date by which the amendment has to be implemented
at national level by publication of a harmonized
national standard or by endorsement (dop) 2009-09-01

– latest date by which the national standards conflicting
with the amendment have to be withdrawn (dow) 2010-09-01
_________

---------------------- Page: 4 ----------------------

SIST HD 516 S2:1999/A2:2009
– 3 – HD 516 S2:1997/A2:2008
Table 1A – Intended Usage of Single Core PVC Cables for Fixed Wiring

Add the following new columns for HD 21.15:


Standard HD 21.15 HD 21.15
Clause number 4/5 6/7
Code designation H07Z1 H05Z1
Conductor type U R K U R K

1. METHOD OF INSTALLATION (5)
+ + + - - -
1.1 In conduit (6)
+ + + +(1) +(1) +(1)
1.2 In cable trunking (6)
+ + + - - -
1.3 In cable ducting (6)
+(3) +(3) +(3) +(3) +(3) +(3)
1.4 In cable wiring of electric appliances and equipment
Notes: (1) Signalling and control circuits only.
 (2) For installation at low temperatures.
 (3) For use in normal temperature zones.
 (4) For use in higher temperature zones.
 (5) The presence of water in contact with the cable is not acceptable.
 (6) The maximum conductor temperature at which the particular cable should operate will depend upon the limiting
temperature of the other cables and accessories with which it is in contact.
 '+' = Acceptable application.
 '-' = Not suitable.

---------------------- Page: 5 ----------------------

SIST HD 516 S2:1999/A2:2009
HD 516 S2:1997/A2:2008 – 4 –
Supplement to Table 1A – Specific Guidance for Use of Single Core PVC Cables for Fixed
Wiring

Add the following entries for Part 15:

1 2 3
Part No. Recommended use Comments
PART 15 Installation in surface mounted or Suitable for fixed protected installation in,
embedded conduits, or similar closed or on, lighting and control gear for
Single core non-sheathed halogen free
systems, particularly for situations in voltages up to 1 000 V a.c. or, up to
cables for fixed wiring of rated voltage
which low emission of smoke and 750 V d.c. to earth.
450/750 V
corrosive gases are required in the case
Clause 4 H07Z1-U and H07Z1-R
of burning.
Clause 5 H07Z1-K
Type 2 cables are for use where special
fire performance is necessary, or where

local conditions or regulations require
increased levels of public safety (for
example in hospitals, cinemas or
schools). They are especially suitable for
use where cables are installed in
bunches.
PART 15 Fixed protected installation inside Suitable for installation in surface
appliances and in, or on, lighting fittings, mounted or embedded conduits, only for
Single core non-sheathed halogen free
particularly for situations in which low signalling or control circuits.
cables for fixed wiring of rated voltage
emission of smoke and corrosive gases
300/500 V
are required in the case of burning.
Clause 6 H05Z1-U and H05Z1-R

Clause 7 H05Z1-K
The maximum permitted conductor temperature for cables to Part 15 in normal use is
70 °C.

These cables are not intended to provide circuit integrity in case of fire.

The defined tests for smoke and halogen free gases relates only to the cables, and
not to cable and conduit together.