SIST EN 60454-2:2007
(Main)Pressure-sensitive adhesive tapes for electrical purposes -- Part 2: Methods of test
Pressure-sensitive adhesive tapes for electrical purposes -- Part 2: Methods of test
This part of IEC 60454 specifies methods of test for pressure-sensitive adhesive tapes for electrical purposes.
Selbstklebende Bänder für elektrotechnische Anwendungen -- Teil 2: Prüfverfahren
Rubans adhésifs sensibles à la pression à usages électriques -- Partie 2: Méthodes d'essai
Décrit les méthodes pour déterminer la résistance mécanique et électrique et les propriétés adhésives des rubans adhésifs sensibles à la pression, et contient les méthodes d'essai à utiliser.
Samolepilni trakovi za električne namene - 2. del: Preskuševalne metode (IEC 60454-2:2007)
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 60454-2:2007
01-december-2007
1DGRPHãþD
SIST EN 60454-2:1998
6DPROHSLOQLWUDNRYL]DHOHNWULþQHQDPHQHGHO3UHVNXãHYDOQHPHWRGH,(&
Pressure-sensitive adhesive tapes for electrical purposes - Part 2: Methods of test (IEC
60454-2:2007)
Selbstklebende Bänder für elektrotechnische Anwendungen - Teil 2: Prüfverfahren (IEC
60454-2:2007)
Rubans adhésifs sensibles a la pression a usages électriques - Partie 2: Méthodes
d'essai (IEC 60454-2:2007)
Ta slovenski standard je istoveten z: EN 60454-2:2007
ICS:
29.035.20 3ODVWLþQLLQJXPHQLL]RODFLMVNL Plastics and rubber insulating
PDWHULDOL materials
SIST EN 60454-2:2007 en,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
EUROPEAN STANDARD
EN 60454-2
NORME EUROPÉENNE
September 2007
EUROPÄISCHE NORM
ICS 17.220.99; 29.035.20 Supersedes EN 60454-2:1995
English version
Pressure-sensitive adhesive tapes for electrical purposes -
Part 2: Methods of test
(IEC 60454-2:2007)
Rubans adhésifs sensibles Selbstklebende Bänder
à la pression à usages électriques - für elektrotechnische Anwendungen -
Partie 2: Méthodes d'essai Teil 2: Prüfverfahren
(CEI 60454-2:2007) (IEC 60454-2:2007)
This European Standard was approved by CENELEC on 2007-09-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2007 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60454-2:2007 E
---------------------- Page: 2 ----------------------
EN 60454-2:2007 - 2 -
Foreword
The text of document 15/377/FDIS, future edition 3 of IEC 60454-2, prepared by IEC TC 15, Solid
electrical insulating materials, was submitted to the IEC-CENELEC parallel vote and was approved by
CENELEC as EN 60454-2 on 2007-09-01.
This European Standard supersedes EN 60454-2:1995.
This revision includes improved text regarding the flame test (Clause 20), improved text on adhesion
(Clause 11) and new Figures 9a and 9b.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
(dop) 2008-06-01
national standard or by endorsement
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2010-09-01
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 60454-2:2007 was approved by CENELEC as a European
Standard without any modification.
__________
---------------------- Page: 3 ----------------------
- 3 - EN 60454-2:2007
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication Year Title EN/HD Year
- - Self-adhesive tapes - Determination of peel EN 1939 2003
adhesion properties
IEC 60216-1 2001 Electrical insulating materials - Properties of EN 60216-1 2001
thermal endurance -
Part 1: Ageing procedures and evaluation of
test results
IEC 60216-2 2005 Electrical insulating materials - Thermal EN 60216-2 2005
endurance properties -
Part 2: Determination of thermal endurance
properties of electrical insulating materials -
Choice of test criteria
IEC 60216-3 2006 Electrical insulating materials - Thermal EN 60216-3 2006
endurance properties -
Part 3: Instructions for calculating thermal
endurance characteristics
IEC 60243-1 1998 Electrical strength of insulating materials - EN 60243-1 1998
Test methods -
Part 1: Tests at power frequencies
IEC 60426 2007 Electrical insulating materials - Determination EN 60426 2007
of electrolytic corrosion caused by insulating
materials - Test methods
IEC 60454-3 Series Pressure-sensitive adhesive tapes for EN 60454-3 Series
electrical purposes -
Part 3: Specifications for individual materials
IEC 60589 1977 Methods of test for the determination of ionic HD 381 S1 1979
impurities in electrical insulating materials by
extraction with liquids
ISO 383 1976 Laboratory glassware - Interchangeable - -
conical ground joints
ISO 527-3 1995 Plastics - Determination of tensile properties - EN ISO 527-3 1995
Part 3: Test conditions for films and sheets
ISO 2194 1991 Industrial screens - Woven wire cloth, - -
perforated plate and electroformed sheet -
Designation and nominal sizes of openings
ISO 3071 2005 Textiles - Determination of pH of aqueous EN ISO 3071 2006
extract
---------------------- Page: 4 ----------------------
EN 60454-2:2007 - 4 -
Publication Year Title EN/HD Year
ISO 3599 1976 Vernier callipers reading to 0,1 and 0,05 mm - -
ISO 10093 1998 Plastics - Fire tests - Standard ignition EN ISO 10093 1998
sources
---------------------- Page: 5 ----------------------
INTERNATIONAL IEC
STANDARD 60454-2
Third edition
2007-06
Pressure-sensitive adhesive tapes
for electrical purposes –
Part 2:
Methods of test
PRICE CODE
Commission Electrotechnique Internationale X
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
For price, see current catalogue
---------------------- Page: 6 ----------------------
– 2 – 60454-2 © IEC:2007(E)
CONTENTS
FOREWORD.5
1 Scope.7
2 Normative references .7
3 Conditioning and specimen preparation .8
4 Determination of thickness .8
4.1 Test apparatus .8
4.2 Test specimens .8
4.3 Procedure .8
4.4 Results.8
5 Determination of width.8
5.1 Method A.8
5.2 Method B.9
5.3 Method C .9
6 Determination of roll length.10
6.1 Principle.10
6.2 Method A – Measurement of turns method .10
6.3 Method B – Length sensor method .11
7 Corrosion-related properties .11
7.1 General .11
7.2 Preparation of water extract for pH and conductivity determinations .11
7.3 Determination of pH value of water extract .12
7.4 Determination of conductivity of water extract .12
7.5 Detection of corrosive sulfur .13
7.6 Insulation resistance method .14
7.7 Visual method .14
7.8 Wire tensile strength method .14
8 Tensile strength and elongation at break .15
8.1 Apparatus.15
8.2 Test specimens .15
8.3 Procedure .15
8.4 Results.15
9 Low-temperature properties.15
9.1 Principle.15
9.2 Test specimen.16
9.3 Procedure .16
9.4 Flexibility.16
9.5 Electric strength .16
9.6 Results.16
10 Resistance to penetration at elevated temperatures .17
10.1 Apparatus.17
10.2 Test specimens .17
10.3 Procedure .17
10.4 Results.17
11 Adhesion .17
---------------------- Page: 7 ----------------------
60454-2 © IEC:2007(E) – 3 –
11.1 Principle.17
11.2 Materials .18
11.3 Apparatus.18
11.4 Test samples and test pieces .19
11.5 Procedure .20
11.6 Expression of results.20
12 Adhesion to backing at low temperatures.21
12.1 Test specimens .21
12.2 Procedure .21
12.3 Results.21
13 Shear adhesion to backing after liquid immersion .21
13.1 Apparatus.21
13.2 Test specimens .21
13.3 Procedure .22
13.4 Results.22
14 Curing properties of thermosetting adhesive tapes .22
14.1 Bond separation during thermal treatment (adhesive to backing) .22
14.2 Bond separation after thermal treatment (adhesion to backing) .22
15 Flagging tests.23
15.1 Principle.23
15.2 Apparatus.23
15.3 Test specimens .23
15.4 Preparation of specimens for test .24
15.5 Test conditions.24
15.6 Results.24
16 Water vapor permeability.24
16.1 Apparatus.24
16.2 Test specimens .24
16.3 Procedure .25
16.4 Results.25
17 Electric strength .25
17.1 General .25
17.2 Test specimens .25
17.3 Procedure .25
17.4 Results.25
18 Electric strength after humid conditioning .26
19 Resistance to flame propagation .26
19.1 Principle.26
19.2 Apparatus.26
19.3 Test specimen.26
19.4 Procedure .27
19.5 Results.27
20 Flame test .27
20.1 Principle.27
20.2 Apparatus.28
20.3 Preparation of test specimen .28
20.4 Procedure .29
20.5 Results.29
---------------------- Page: 8 ----------------------
– 4 – 60454-2 © IEC:2007(E)
21 Thermal endurance .29
21.1 Determination of thermal endurance (based on IEC 60216-1 and IEC 60216-2).29
21.2 Voltage breakdown.30
21.3 Loss of mass.31
Annex A (normative) Rollers to be used in various tests.40
Bibliography.41
Figure 1 – Measuring device for determination of roll length of tape (measurement of
turns method) .32
Figure 2 – Measuring device for determination of roll length of tape (length sensor
method) .32
Figure 3 – Sequence of bends .33
Figure 4 – Dielectric strength test in water .33
Figure 5 – Sketch of penetration tester .34
Figure 6 – Steel test plate.35
Figure 7 – Arrangement for stripping the tape from the plate.35
Figure 8 – Flagging test – Preparation of test specimen.36
Figure 9a – Draught protection device .37
Figure 9b – Use of Bunsen burner and sliding plate with draught protection device.37
Figure 9 – Flame test enclosures .37
Figure 10 – Essential dimensions for flame test (proportions exaggerated for clarity of
details) .38
Figure 11 – Dimensions of wedge .39
Table 1 – Conditioning for low temperature properties .16
---------------------- Page: 9 ----------------------
60454-2 © IEC:2007(E) – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
PRESSURE-SENSITIVE ADHESIVE TAPES
FOR ELECTRICAL PURPOSES –
Part 2: Methods of test
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60454-2 has been prepared by IEC technical committee 15: Solid
electrical insulating materials.
This third edition cancels and replaces the second edition published in 1994, and constitutes
a technical revision. This revision includes improved text regarding the flame test (Clause 20),
the improved text on adhesion (Clause 11) and a new Figures 9a and 9b.
The text of this standard is based on the following documents:
FDIS Report on voting
15/377/FDIS 15/387/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
---------------------- Page: 10 ----------------------
– 6 – 60454-2 © IEC:2007(E)
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all the parts in the IEC 60454 series, under the general title Pressure-sensitive
adhesive tapes for electrical purposes, can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in
the data related to the specific publication. At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
A bilingual version of this publication may be issued at a later date.
---------------------- Page: 11 ----------------------
60454-2 © IEC:2007(E) – 7 –
PRESSURE-SENSITIVE ADHESIVE TAPES
FOR ELECTRICAL PURPOSES –
Part 2: Methods of test
1 Scope
This part of IEC 60454 specifies methods of test for pressure-sensitive adhesive tapes for
electrical purposes.
2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 60216-1:2001, Electrical insulating materials – Properties of thermal endurance – Part 1:
Ageing procedures and evaluation of test results
IEC 60216-2:2005, Electrical insulating materials – Thermal endurance properties – Part 2:
Determination of thermal endurance properties of electrical insulating materials – Choice of
test criteria
IEC 60216-3:2006, Electrical insulating materials – Thermal endurance properties – Part 3:
Instructions for calculating thermal endurance characteristics
IEC 60243-1:1998, Electrical strength of insulating materials – Test methods – Part 1: Tests
at power frequencies
IEC 60426:2007, Test methods for determining electrolytic corrosion with insulating materials
IEC 60454-3 (all parts), Pressure-sensitive adhesive tapes for electrical purposes – Part 3:
Specifications for individual materials
IEC 60589:1977, Methods of test for the determination of ionic impurities in electrical
insulating materials by extraction with liquids
ISO 383: 1976, Laboratory glassware – Interchangeable conical ground joints
ISO 527-3:1995, Plastics – Determination of tensile properties – Part 3: Test conditions for
films and sheets
ISO 2194:1991, Industrial screens – Woven wire cloth, perforated place and electroformed
sheet – Designation and nominal sizes of openings
ISO 3071:2005, Textiles – Determination of pH of the aqueous extract
ISO 3599:1976, Vernier callipers reading to 0,1 and 0,05 mm
ISO 10093:1998, Plastics – Fire tests – Standard ignition sources
EN 1939:2003, Self-adhesive tapes − Determination of peel adhesion properties (The peel
adhesion test method of Clause 11 is based on test method A of EN 1939:2003. This standard
is the result of the harmonisation of AFERA 5001 and PSTC-1,2,3 and 4, ASTM 3330/D,
ASTM 3330/M and agreed by JATMA.)
NOTE EN: European Norm (Europe) − AFERA: Association des fabricants européens de rubans auto-adhésifs −
PSTC: Pressure sensitive tape council (USA) − ASTM: American society for testing and materials (USA) − JATMA:
Japanese adhesive tapes manufacturers association.
---------------------- Page: 12 ----------------------
– 8 – 60454-2 © IEC:2007(E)
3 Conditioning and specimen preparation
Unless otherwise specified, rolls are to be conditioned for at least 24 h at (23 ± 2) °C and
(50 ± 5) % relative humidity and all test procedures are to be carried out in this atmosphere.
Remove and discard the three outer turns before taking any test specimens from the
conditioned roll. Specimen preparation shall be done with care in a clean environment.
Specific specimen preparation details will be included with the appropriate test method.
Further conditioning of test specimens may be required.
4 Determination of thickness
4.1 Test apparatus
A dead-weight thickness gauge having two ground and concentric circular surfaces, flat within
0,001 mm and parallel to within 0,003 mm. The upper surface shall be 6 mm to 8 mm in
diameter and the lower surface larger than the upper one. The upper surface shall move on
the axis perpendicular to the two faces.
The gauge shall be graduated to read directly to 0,002 mm. The frame of the thickness gauge
shall be of such rigidity that a load of 15 N applied to the gauge housing, out o
...