SIST EN 60623:2002
(Main)Secondary cells and batteries containing alkaline or other non-acid electrolytes - Vented nickel-cadmium prismatic rechargeable single cells
Secondary cells and batteries containing alkaline or other non-acid electrolytes - Vented nickel-cadmium prismatic rechargeable single cells
Specifies tests and requirements for vented nickel-cadmium prismatic secondary single cells.
Akkumulatoren und Batterien mit alkalischem oder anderem nicht-säurehaltigen Elektrolyten - Geschlossene prismatische wiederaufladbare Nickel-Cadmium-Einzelzellen
Accumulateurs alcalins ou autres accumulateurs à électrolyte non acide - Eléments individuels parallélépipédiques rechargeables ouverts au nickel-cadmium
Spécifie les essais et les prescriptions applicables aux éléments individuels parallélépipédiques rechargeables ouverts au nickel-cadmium.
Secondary cells and batteries containing alkaline or other non-acid electrolytes - Vented nickel-cadmium prismatic rechargeable single cells
General Information
Relations
Standards Content (Sample)
SLOVENSKI SIST EN 60623:2002
izdaja
STANDARD
september 2002
Secondary cells and batteries containing alkaline or other non-acid electrolytes -
Vented nickel-cadmium prismatic rechargeable single cells
ICS 29.220.30 Referenčna številka
SIST EN 60623:2002(en)
© Standard je založil in izdal Slovenski inštitut za standardizacijo. Razmnoževanje ali kopiranje celote ali delov tega dokumenta ni dovoljeno
---------------------- Page: 1 ----------------------
EUROPEAN STANDARD EN 60623
NORME EUROPÉENNE
EUROPÄISCHE NORM November 2001
ICS 29.220.99 Supersedes EN 60623:1995
English version
Secondary cells and batteries containing alkaline
or other non-acid electrolytes -
Vented nickel-cadmium prismatic rechargeable single cells
(IEC 60623:2001)
Accumulateurs alcalins ou autres Akkumulatoren und Batterien
accumulateurs à électrolyte non acide - mit alkalischem oder anderem
Eléments individuels parallélépipédiques nicht-säurehaltigen Elektrolyten -
rechargeables ouverts au nickel-cadmium Geschlossene prismatische
(CEI 60623:2001) wiederaufladbare Nickel-Cadmium-
Einzelzellen
(IEC 60623:2001)
This European Standard was approved by CENELEC on 2001-10-01. CENELEC members are bound to
comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and
notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic,
Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands,
Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2001 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60623:2001 E
---------------------- Page: 2 ----------------------
EN 60623:2001 - 2 -
Foreword
The text of document 21A/327/FDIS, future edition 4 of IEC 60623, prepared by SC 21A, Secondary
cells and batteries containing alkaline or other non-acid electrolytes, of IEC TC 21, Secondary cells
and batteries, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as
EN 60623 on 2001-10-01.
This European Standard supersedes EN 60623:1995.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2002-07-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2004-10-01
Annexes designated "normative" are part of the body of the standard.
In this standard, annex ZA is normative.
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 60623:2001 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following note has to be added for the standard indicated:
IEC 61434 NOTE Harmonized as EN 61434:1996 (not modified).
__________
---------------------- Page: 3 ----------------------
- 3 - EN 60623:2001
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
This European Standard incorporates by dated or undated reference, provisions from other
publications. These normative references are cited at the appropriate places in the text and the
publications are listed hereafter. For dated references, subsequent amendments to or revisions of any
of these publications apply to this European Standard only when incorporated in it by amendment or
revision. For undated references the latest edition of the publication referred to applies (including
amendments).
NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.
Publication Year Title EN/HD Year
1)
IEC 60050-486 - International Electrotechnical --
Vocabulary
Chapter 486: Secondary cells and
batteries
IEC 60051 Series Direct acting indicating analogue EN 60051 Series
electrical measuring instruments and
their accessories
1)
IEC 60410 - Sampling plans and procedures for--
inspection by attributes
IEC 60417 Series Graphical symbols for use on equipment EN 60417 Series
1)
IEC 60485 - Digital electronic d.c. voltmeters and--
d.c. electronic analogue-to-digital
converters
1)
IEC 61438 - Possible safety and health hazards in--
the use of alkaline secondary cells and
batteries - Guide to equipment
manufacturers and users
1)
Undated reference.
---------------------- Page: 4 ----------------------
NORME
CEI
INTERNATIONALE IEC
60623
INTERNATIONAL
Quatrième édition
STANDARD
Fourth edition
2001-09
Accumulateurs alcalins ou autres accumulateurs
à électrolyte non acide –
Eléments individuels parallélépipédiques
rechargeables ouverts au nickel-cadmium
Secondary cells and batteries containing alkaline
or other non-acid electrolytes –
Vented nickel-cadmium prismatic rechargeable
single cells
© IEC 2001 Droits de reproduction réservés ⎯ Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in
utilisée sous quelque forme que ce soit et par aucun procédé, any form or by any means, electronic or mechanical,
électronique ou mécanique, y compris la photocopie et les including photocopying and microfilm, without permission in
microfilms, sans l'accord écrit de l'éditeur. writing from the publisher.
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http://www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
Q
PRICE CODE
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue
---------------------- Page: 5 ----------------------
60623 © IEC:2001 – 3 –
CONTENTS
FOREWORD . 7
INTRODUCTION .9
1 General. 11
1.1 Scope . 11
1.2 Normative references. 11
1.3 Definitions. 11
1.4 Parameter measurement tolerances . 13
2 Designation and marking. 13
2.1 Cell designation . 13
2.2 Cell termination. 15
2.3 Marking. 15
2.4 Safety recommendations . 15
3 Dimensions . 15
4 Electrical tests .19
4.1 Charging procedure for test purposes. 19
4.2 Discharge performance . 19
4.2.1 Discharge performance at 20 °C. 19
4.2.2 Discharge performance at +5 °C. 19
4.2.3 Discharge performance at –18 °C . 21
4.2.4 High rate current test. 21
4.3 Charge retention . 23
4.4 Endurance . 23
4.4.1 Endurance in cycles . 23
4.4.2 Permanent charge endurance. 25
4.5 Charge acceptance at constant voltage . 25
4.6 Overcharge . 25
4.7 Vent plug operation . 25
4.8 Electrolyte retention test. 27
4.8.1 Test procedure. 27
4.8.2 Acceptance criteria:. 27
4.9 Storage. 27
5 Mechanical tests . 27
6 Physical appearance . 27
7 Conditions for approval and acceptance . 29
7.1 Type approval . 29
7.2 Batch acceptance. 31
Bibliography . 32
---------------------- Page: 6 ----------------------
60623 © IEC:2001 – 5 –
Figure 1 – Example of a vented prismatic cell in steel container with two terminals and
four lugs . 15
Table 1a – Dimensions for vented nickel-cadmium prismatic cells in steel containers. 17
Table 1b – Dimensions for vented nickel- cadmium prismatic cells in plastic containers. 17
Table 2 – Measurement tolerances in millimetres (valid for widths and lengths). 17
Table 3 – Discharge performance at 20 °C. 19
Table 4 – Discharge performance at +5 °C. 21
Table 5 – Discharge performance at –18 °C. 21
Table 6 – High currents values. 23
Table 7 – Endurance in cycles . 25
Table 8 – Constant voltage charging conditions. 25
Table 9 – Sequence of tests for type approval. 29
Table 10 – Recommended test sequence for batch acceptance. 31
---------------------- Page: 7 ----------------------
60623 © IEC:2001 – 7 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
SECONDARY CELLS AND BATTERIES CONTAINING ALKALINE
OR OTHER NON-ACID ELECTROLYTES –
VENTED NICKEL-CADMIUM PRISMATIC RECHARGEABLE
SINGLE CELLS
FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, the IEC publishes International Standards. Their preparation is
entrusted to technical committees; any IEC National Committee interested in the subject dealt with may
participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. The IEC collaborates closely with the International Organization
for Standardization (ISO) in accordance with conditions determined by agreement between the two
organizations.
2) The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an
international consensus of opinion on the relevant subjects since each technical committee has representation
from all interested National Committees.
3) The documents produced have the form of recommendations for international use and are published in the form
of standards, technical specifications, technical reports or guides and they are accepted by the National
Committees in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with one of its standards.
6) Attention is drawn to the possibility that some of the elements of this International Standard may be the subject
of patent rights. The IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60623 has been prepared by subcommittee 21A: Secondary cells
and batteries containing alkaline or other non-acid electrolytes, of IEC technical committee 21:
Secondary cells and batteries.
This fourth edition cancels and replaces the third edition published in 1990, Amendment 1
(1992) and Amendment 2 (1992), and constitutes a technical revision.
The text of this standard is based on the following documents:
FDIS Report on voting
21A/327/FDIS 21A/329/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 3.
The committee has decided that the contents of this publication will remain unchanged until
2006-01. At this date, the publication will be
reconfirmed;
withdrawn;
replaced by a revised edition, or
amended.
---------------------- Page: 8 ----------------------
60623 © IEC:2001 – 9 –
INTRODUCTION
Traditionally the manufacturers and users of alkaline secondary cells and batteries have
expressed the current used to charge and discharge these cells and batteries as a multiple of
the capacity. For example, a current of 20 A used to charge a cell with a rated capacity (C Ah)
of 100 Ah would be expressed as C/5 A or 0,2 C A. This method of current designation has
been used in earlier standards relating to alkaline secondary cells and batteries.
Comments have been made, however, that this method of current designation is dimensionally
incorrect, in that a multiple of the capacity (ampere-hours) will be in ampere-hours and not, as
required for current, in amperes. As a result of these comments, the method described in
IEC 61434 has been used in this standard.
In brief, the method states that the reference test current (I ) is expressed as:
t
C Ah
n
I A =
t
1 h
where
C is the rated capacity declared by the manufacturer in ampere-hours (Ah), and
n
n is the time base in hours (h) for which the rated capacity is declared.
---------------------- Page: 9 ----------------------
60623 © IEC:2001 – 11 –
SECONDARY CELLS AND BATTERIES CONTAINING ALKALINE
OR OTHER NON-ACID ELECTROLYTES –
VENTED NICKEL-CADMIUM PRISMATIC RECHARGEABLE
SINGLE CELLS
1 General
1.1 Scope
This International Standard specifies marking, designation, dimensions, tests and requirements
for vented nickel-cadmium prismatic secondary single cells.
NOTE In this context, "prismatic" refers to cells having rectangular sides and base.
When there exists an IEC standard specifying test conditions and requirements for cells used
in special applications and which is in conflict with this standard, the former shall take
precedence.
1.2 Normative references
The following normative documents contain provisions which, through reference in this text,
constitute provisions of this International Standard. For dated references, subsequent
amendments to, or revisions of, any of these publications do not apply. However, parties to
agreements based on this International Standard are encouraged to investigate the possibility
of applying the most recent editions of the normative documents indicated below. For undated
references, the latest edition of the normative document referred to applies. Members of IEC
and ISO maintain regist
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.