Flexible insulating sleeving -- Part 3: Specifications for individual types of sleeving -- Sheet 233: Heat-shrinkable fluoroelastomer sleeving, flame retarded, fluid resistant, shrink ratio 2:1

This standard gives the requirements for two types of heat-shrinkable, flame retarded, fluid resistant1), nominal shrink ratio 2:1, fluoroelastomer sleeving for use at temperatures up to 200 °C: - Type A: thick wall; - Type B: thin wall. These sleevings are normally supplied with internal diameters up to 51 mm, and the standard colour is black. Sizes or colours other than those specifically listed in this standard may be available as custom items. These items shall be considered to comply with this standard if they comply with the property requirements listed in Tables 3, 4, 5 and 6 except for . dimensions and mass Materials which conform to this specification meet established levels of performance. However, the selection of a material by a user for a specific application should be based on the actual requirements necessary for adequate performance in that application and not based on this specification alone.

Isolierschläuche -- Teil 3: Anforderungen für einzelne Schlauchtypen -- Blatt 233: Fluorelastomer-Wärmeschrumpfschläuche, flammwidrig, flüssigkeitsbeständig, Schrumpfverhältnis 2:1

Gaines isolantes souples -- Partie 3: Spécifications pour types particuliers de gaines -- Feuille 233: Gaines thermorétractables en fluoroélastomère, retardées à la flamme, résistant aux fluides, rapport de rétreint 2:1

Gibke izolacijske cevi – 3. del: Specifikacije posameznih vrst cevi – 233. list: Toplotno skrčljive fluoroelastomerne cevi, ognjevarne, odporne proti tekočinam, skrčno razmerje 2:1 (IEC 60684-3-233:2006)

General Information

Status
Published
Publication Date
30-Jun-2006
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Jul-2006
Due Date
01-Jul-2006
Completion Date
01-Jul-2006

Relations

Buy Standard

Standard
EN 60684-3-233:2006
English language
14 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI SIST EN 60684-3-233:2006

STANDARD
julij 2006
Gibke izolacijske cevi – 3. del: Specifikacije posameznih vrst cevi – 233. list:
Toplotno skrčljive fluoroelastomerne cevi, ognjevarne, odporne proti
tekočinam, skrčno razmerje 2:1 (IEC 60684-3-233:2006)
Flexible insulating sleeving – Part 3: Specifications for individual types of sleeving –
Sheet 233: Heat-shrinkable fluoroelastomer sleeving, flame retarded, fluid
resistant, shrink ratio 2:1 (IEC 60684-3-233:2006)
ICS 29.035.20 Referenčna številka
SIST EN 60684-3-233:2006(en)
©  Standard je založil in izdal Slovenski inštitut za standardizacijo. Razmnoževanje ali kopiranje celote ali delov tega dokumenta ni dovoljeno

---------------------- Page: 1 ----------------------

EUROPEAN STANDARD
EN 60684-3-233

NORME EUROPÉENNE
March 2006
EUROPÄISCHE NORM

ICS 29.035.20 Supersedes EN 60684-3-233:1998


English version


Flexible insulating sleeving
Part 3: Specifications for individual types of sleeving
Sheet 233: Heat-shrinkable fluoroelastomer sleeving,
flame retarded, fluid resistant, shrink ratio 2:1
(IEC 60684-3-233:2006)


Gaines isolantes souples Isolierschläuche
Partie 3: Spécifications pour types Teil 3: Anforderungen für einzelne
particuliers de gaines Schlauchtypen
Feuille 233: Gaines thermorétractables Blatt 233: Fluorelastomer-
en fluoroélastomère, retardées Wärmeschrumpfschläuche, flammwidrig,
à la flamme, résistant aux fluides, flüssigkeitsbeständig,
rapport de rétreint 2:1 Schrumpfverhältnis 2:1
(CEI 60684-3-233:2006) (IEC 60684-3-233:2006)




This European Standard was approved by CENELEC on 2005-11-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, the Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels


© 2006 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60684-3-233:2006 E

---------------------- Page: 2 ----------------------

EN 60684-3-233:2006 - 2 -
Foreword
The text of document 15/231/FDIS, future edition 2 of IEC 60684-3-233, prepared by IEC TC 15,
Standards on specifications for electrical insulating materials, was submitted to the IEC-CENELEC
parallel vote and was approved by CENELEC as EN 60684-3-233 on 2005-11-01.
This European Standard supersedes EN 60684-3-233:1998.
The main change with regard to EN 60684-3-233:1998 concerns the replacement of the thermal
endurance test, according to EN 60216, by a long-term ageing test, i.e. 3 000 h, at the maximum
recommended temperature for such use, in order to furnish thermal test data within a workable time
frame.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
(dop) 2006-11-01
national standard or by endorsement
– latest date by which the national standards conflicting
(dow) 2008-11-01
with the EN have to be withdrawn
This European Standard makes reference to International Standards. Where the International Standard
referred to has been endorsed as a European Standard or a home-grown European Standard exists, this
European Standard shall be applied instead. Pertinent information can be found on the CENELEC web
site.
__________
Endorsement notice
The text of the International Standard IEC 60684-3-233:2006 was approved by CENELEC as a European
Standard without any modification.
__________

---------------------- Page: 3 ----------------------

INTERNATIONAL IEC


STANDARD 60684-3-233





Second edition
2006-01


Flexible insulating sleeving –
Part 3:
Specifications for individual types of sleeving –
Sheet 233: Heat-shrinkable fluoroelastomer
sleeving, flame retarded, fluid resistant, shrink
ratio 2:1

 IEC 2006  Copyright - all rights reserved
No part of this publication may be reproduced or utilized in any form or by any means, electronic or
mechanical, including photocopying and microfilm, without permission in writing from the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
PRICE CODE
Commission Electrotechnique Internationale M
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
For price, see current catalogue

---------------------- Page: 4 ----------------------

– 2 – 60684-3-233  IEC:2006(E)
CONTENTS

FOREWORD.3
INTRODUCTION.5

1 Scope.6
2 Normative references.6
3 Designation .7
4 Conditions of test.7
5 Requirements .7
6 Sleeving conformance.7
7 Breakdown voltage .11

Table 1 – Type A Dimensional and mass requirements .8
Table 2 – Type B Dimensional and mass requirements .8
Table 3 – Property requirements .9
Table 4 – Requirements for breakdown voltage .12
Table 5 – Resistance to selected fluids.12
Table 6 – Additional property requirements.12

---------------------- Page: 5 ----------------------

60684-3-233  IEC:2006(E) – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
___________

FLEXIBLE INSULATING SLEEVING –

Part 3: Specifications for individual types of sleeving –
Sheet 233: Heat-shrinkable fluoroelastomer sleeving,
flame retarded, fluid resistant, shrink ratio 2:1


FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60684-3-233 has been prepared by IEC technical committee 15:
Standards on specifications for electrical Insulating materials.
This second edition cancels and replaces
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.