Industrial fans - Vocabulary and definitions of categories (ISO 13349:1999)

This European Standard provides a vocabulary and defines categories for general purpose industrial fans and their component parts. It is applicable to any fan used for industrial purposes, including the ventilation of buildings and mines, but excluding ceiling, pedestal and similar circulation types of fans such as those commonly used for non-industrial purposes.

Industrieventilatoren - Terminologie und Klassifizierung (ISO 13349:1999)

Diese Internationale Norm enthält die Terminologie für Universalventilatoren und deren Komponenten und legt
eine Klassifizierung fest. Sie ist anwendbar auf alle Ventilatoren für industrielle Zwecke, einschließlich der
Lüftung von Gebäuden und Untertagebauwerken. Ausgenommen sind Decken-, Stand- und vergleichbare
Umwälzventilatoren, die für gewöhnlich für nichtindustrielle Zwecke Verwendung finden.

Ventilateurs industriels - Vocabulaire et définitions des catégories (ISO 13349:1999)

L'IEC 60846-2:2015 est applicable aux instruments portables ou transportables de mesure et/ou de surveillance de l'équivalent de dose (ou du débit d'équivalent de dose) ambiant et/ou directionnel pour les rayonnements externes bêta, X et gamma d'énergie jusqu'à 10 MeV, dans des situations d'urgence. L'objet de la présente Norme internationale est de spécifier les exigences de conception et les caractéristiques d'aptitude à la fonction des instruments de mesure d'équivalent de dose (ou du débit d'équivalent de dose) destinés à la détermination de l'équivalent de dose (ou du débit d'équivalent de dose) ambiant et/ou directionnel tel que défini dans le rapport ICRU 47, pour les situations d'urgence. La modification technique majeure par rapport à l'édition précédente consiste en une mise à jour prenant en compte l'édition révisée de l'IEC 60846-1:2009. Cette Norme internationale IEC 60846-2 doit être utilisée conjointement avec l'IEC 60846-1:2009.

Industrijski ventilatorji - Izrazi in definicije kategorij (ISO 13349:1999)

General Information

Status
Withdrawn
Publication Date
10-Feb-2009
Withdrawal Date
19-Jul-2010
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
20-Jul-2010
Due Date
12-Aug-2010
Completion Date
20-Jul-2010

Relations

Buy Standard

Standard
EN ISO 13349:2009
English language
43 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN ISO 13349:2009
01-april-2009
Industrijski ventilatorji - Izrazi in definicije kategorij (ISO 13349:1999)
Industrial fans - Vocabulary and definitions of categories (ISO 13349:1999)
Ventilateurs industriels - Vocabulaire et définitions des catégories (ISO 13349:1999)
Ta slovenski standard je istoveten z: EN ISO 13349:2008
ICS:
01.040.23 7HNRþLQVNLVLVWHPLLQVHVWDYQL Fluid systems and
GHOL]DVSORãQRUDER 6ORYDUML components for general use
(Vocabularies)
23.120 =UDþQLNL9HWUQLNL.OLPDWVNH Ventilators. Fans. Air-
QDSUDYH conditioners
SIST EN ISO 13349:2009 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN ISO 13349:2009

---------------------- Page: 2 ----------------------

SIST EN ISO 13349:2009
EUROPEAN STANDARD
EN ISO 13349
NORME EUROPÉENNE
EUROPÄISCHE NORM
October 2008
ICS 01.040.23; 23.120

English Version
Industrial fans - Vocabulary and definitions of categories (ISO
13349:1999)
Ventilateurs industriels - Vocabulaire et définitions des
catégories (ISO 13349:1999)
This European Standard was approved by CEN on 2 October 2008.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the
official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,
France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,
Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36  B-1050 Brussels
© 2008 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 13349:2008: E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------

SIST EN ISO 13349:2009
EN ISO 13349:2008 (E)
Contents Page
Foreword.3

2

---------------------- Page: 4 ----------------------

SIST EN ISO 13349:2009
EN ISO 13349:2008 (E)
Foreword
The text of ISO 13349:1999 has been prepared by Technical Committee ISO/TC 117 “Industrial fans” of the
International Organization for Standardization (ISO) and has been taken over as EN ISO 13349:2008 by
Technical Committee CEN/TC 156 “Ventilation for buildings” the secretariat of which is held by BSI.
This European Standard shall be given the status of a national standard, either by publication of an identical
text or by endorsement, at the latest by April 2009, and conflicting national standards shall be withdrawn at the
latest by April 2009.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.
Endorsement notice
The text of ISO 13349:1999 has been approved by CEN as a EN ISO 13349:2008 without any modification.

3

---------------------- Page: 5 ----------------------

SIST EN ISO 13349:2009

---------------------- Page: 6 ----------------------

SIST EN ISO 13349:2009
INTERNATIONAL ISO
STANDARD 13349
First edition
1999-10-01
Industrial fans — Vocabulary and
definitions of categories
Ventilateurs industriels — Vocabulaire et définitions des catégories
A
Reference number
ISO 13349:1999(E)

---------------------- Page: 7 ----------------------

SIST EN ISO 13349:2009
ISO 13349:1999(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO
member bodies). The work of preparing International Standards is normally carried out through ISO technical
committees. Each member body interested in a subject for which a technical committee has been established has
the right to be represented on that committee. International organizations, governmental and non-governmental, in
liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical
Commission (IEC) on all matters of electrotechnical standardization.
Draft International Standards adopted by the technical committees are circulated to the member bodies for voting.
Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote.
International Standard ISO 13349 was prepared by Technical Committee ISO/TC 117, Industrial fans.
Annex A of this International Standard is for information only.
©  ISO 1999
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic
or mechanical, including photocopying and microfilm, without permission in writing from the publisher.
International Organization for Standardization
Case postale 56 • CH-1211 Genève 20 • Switzerland
Internet iso@iso.ch
Printed in Switzerland
ii

---------------------- Page: 8 ----------------------

SIST EN ISO 13349:2009
© ISO
ISO 13349:1999(E)
Introduction
This International Standard reflects the importance of a standardized approach to the terminology of fans.
The need for an International Standard has been evident for some considerable time. To take just one example, the
coding of driving arrangements differs from manufacturer to manufacturer. What one currently calls Arrangement 1
may be known by another as Arrangement 3. The confusion for the customer is only too apparent. For similar
reasons, it is essential to use standardized nomenclature to identify particular parts of a fan.
Wherever possible, in the interests of international comprehension, this International Standard is in agreement with
similar documents produced by Eurovent, AMCA, VDMA (Germany), AFNOR (France) and UNI (Italy). They have,
however, been built on where the need for amplification was apparent.
Use of this International Standard will lead to greater understanding among all parts of the air-moving industry. It is
hoped that manufacturers, consultants, contractors and users will adopt and refer to this International Standard as
soon as possible.
iii

---------------------- Page: 9 ----------------------

SIST EN ISO 13349:2009

---------------------- Page: 10 ----------------------

SIST EN ISO 13349:2009
INTERNATIONAL STANDARD  © ISO ISO 13349:1999(E)
Industrial fans — Vocabulary and definitions of categories
1 Scope
This International Standard provides a vocabulary and defines categories for general purpose industrial fans and
their component parts. It is applicable to any fan used for industrial purposes, including the ventilation of buildings
and mines, but excluding ceiling, pedestal and similar circulation types of fans such as those commonly used for
non-industrial purposes.
2 Normative references
The following standards contain provisions which, through reference in this text, constitute provisions of this
International Standard. At the time of publication the editions indicated were valid. All standards are subject to
revision, and parties to agreements based on this International Standard are encouraged to investigate the
possibility of applying the most recent editions of the standards listed below. Members of IEC and ISO maintain
registers of currently valid International Standards.
ISO 5801:1997, Industrial fans — Performance testing using standardized airways.
1
)
ISO 5802:— ,
Industrial fans — Performance testing in situ.
ISO 13350:1999, Industrial fans — Performance testing of jet fans.
ISO 13351:1996, Industrial fans — Dimensions.
3 Definitions
For the purposes of this International Standard, the following definitions apply.
3.1
fan
rotary-bladed machine which receives mechanical energy and utilizes it by means of one or more impellers fitted
with blades to maintain a continuous flow of air or other gas passing through it and whose work per unit mass does
not normally exceed 25 kJ/kg
NOTE 1 The term "fan" is taken to mean the fan as supplied without any addition to the inlet or outlet, except where such
addition is specified.
NOTE 2 Fans are defined according to their installation category, function, fluid path and operating conditions.
NOTE 3 If the work per unit mass exceeds a value of 25 kJ/kg, the machine is termed a turbocompressor. This means that,
3
for a mean stagnation density through the fan of 1,2 kg/m , the fan pressure will not exceed 1,2 ´ 25 kJ/kg, i.e. 30 kPa, and the
pressure ratio will not exceed 1,30 since atmospheric pressure is approximately 100 kPa.

1)
To be published.
1

---------------------- Page: 11 ----------------------

SIST EN ISO 13349:2009
© ISO
ISO 13349:1999(E)
3.2
air
in this International Standard, an abbreviation for the expression "air or other gas"
3.3
standard air
3
by convention, air with a density of 1,2 kg/m
3.4  Fan installation types according to the arrangement of ducting (see figure 1)
3.4.1
installation type A
installation with free inlet and free outlet
[ISO 5801 and ISO 5802]
3.4.2
installation type B
installation with free inlet and ducted outlet
[ISO 5801 and ISO 5802]
3.4.3
installation type C
installation with ducted inlet and free outlet
[ISO 5801 and ISO 5802]
3.4.4
installation type D
installation with ducted inlet and ducted outlet
[ISO 5801 and ISO 5802]
3.5  Types of fan according to their function
3.5.1
ducted fan
fan used for moving air within a duct
NOTE Such a fan may be arranged in an installation of type (B), (C) or (D) (see figures 2, 3 and 5).
3.5.2
partition fan
fan used for moving air from one free space to another separated from the first by a partition having an aperture in
which or on which the fan is installed
NOTE Such a fan should be arranged in an installation of type (A) (see figure 6).
3.5.3
jet fan
fan used for producing a jet of air in a space and unconnected to any ducting (see figures 7 and 8)
NOTE The air jet may be used for example for adding momentum to the air within a duct, a tunnel or other space, or for
intensifying the heat transfer in a determined zone.
3.6  Fan types according to the fluid path within the impeller
3.6.1
centrifugal fan
fan in which the air enters the impeller with an essentially axial direction and leaves it in a direction perpendicular to
this axis (see figure 2)
2

---------------------- Page: 12 ----------------------

SIST EN ISO 13349:2009
© ISO
ISO 13349:1999(E)
NOTE 1 The centrifugal fan is also known as a radial-flow fan.
NOTE 2 The impeller may have one or two inlet(s) and may or may not include a shroud and/or a backplate (centreplate)
(see figure 14).
NOTE 3 The impeller is defined as "backward-curved or inclined", "radial" or "forward-curved" depending on whether the
outward direction of the blade at the periphery is backward, radial or forward relative to the direction of the rotation (see
figure 14).
NOTE 4 A centrifugal fan may be of the low, medium or high pressure type, according to the aspect ratio of fan inlet diameter
to outside diameter of the impeller. These terms indicate that the pressure generated at a given flowrate is low, medium or
high.
NOTE 5 Figure 5 shows a cross-section through a family of impellers having the same inlet diameter. Fans with ratios of fan
inlet/outside impeller diameter of greater than approximately 0,63 are considered "low aspect ratio", and lower than
approximately 0,4 are considered "high aspect ratio". Medium aspect ratio centrifugal fans are intermediate between these two
figures.
NOTE 6 The impeller diameter and the casing scroll radii increase with the pressure range for which the fan is designed.
NOTE 7 These categories will also be affected by the ability to run at the necessary peripheral speed (see 5.2 and table 1).
3.6.2
axial-flow fan
fan in which the air enters and leaves the impeller along essentially cylindrical surfaces coaxial with the fan (see
figure 3)
NOTE 1 An axial-flow fan may be of the low, medium or high pressure type according to the aspect ratio of hub diameter to
outside impeller diameter. These terms indicate that the pressure generated at a given flowrate is low, medium or high.
NOTE 2 Figure 10 shows a cross-section through a family of impellers having the same outside diameter. Fans with ratios of
hub/outside impeller diameter of less than approximately 0,4 are considered "low aspect ratio", and greater than approximately
0,71 are considered "high aspect ratio". Medium aspect ratio axial fans are intermediate between these two figures.
NOTE 3 These categories will also be affected by the ability to run at the necessary peripheral speed.
3.6.2.1
contra-rotating fan
axial-flow fan which has two impellers arranged in series and rotating in opposite directions
3.6.2.2
reversible axial-flow fan
axial-flow fan which is specially designed to rotate in either direction regardless of whether the performance is
identical in both directions
3.6.2.3
propeller fan
axial-flow fan having an impeller with a small number of broad blades of uniform material thickness and designed to
operate in an orifice
3.6.2.4
plate mounted axial-flow fan
axial-flow fan in which the impeller rotates in an orifice or spigot of relatively short axial length, the impeller blades
being of aerofoil section
3.6.2.5
vane axial fan
axial-flow fan suitable for ducted applications which has guide vanes before or after the impeller, or both
3.6.2.6
tube axial fan
axial-flow fan without guide vanes, suitable for ducted applications
3

---------------------- Page: 13 ----------------------

SIST EN ISO 13349:2009
© ISO
ISO 13349:1999(E)
3.6.3
mixed-flow fan
fan in which the fluid path through the impeller is intermediate between the centrifugal and axial-flow types (see
figures 7 and 11)
3.6.4
cross-flow fan
fan in which the fluid path through the impeller is in a direction essentially at right angles to its axis both entering and
leaving the impeller at its periphery (see figure 12)
3.6.5
ring-shaped fan
air moving device for which the circulation of fluid in the toric casing is helicoidal
NOTE The rotation of the impeller, which contains a number of blades, creates a helicoidal trajectory which is intercepted
by one or more blades depending on the flowrate. The impeller transfers energy to the fluid (see figure 13).
3.6.6
multi-stage fan
fan having two or more impellers working in series (2-stage fan, 3-stage fan, etc.)
NOTE 1 Multi-stage fans may have guide vanes and/or interconnecting ducts between successive impellers.
NOTE 2 The blades of an impeller may be either of a profiled section (as an aerofoil) or of uniform thickness (see figure 14).
3.6.7
tubular centrifugal fan
fan having a centrifugal impeller used in an inline ducted configuration (see figure 4)
3.6.8
bifurcated fan
fan having an axial, mixed-flow or centrifugal impeller in an inline configuration where the direct-drive motor is
separated from the flowing air stream by means of a compartment or tunnel (see figure 25 Bd)
3.7  Types of fan according to operating conditions
3.7.1
general purpose fan
fan suitable for handling air which is nontoxic, not saturated, noncorrosive, nonflammable, free from abrasive
particles and within a temperature range from 2 20 °C to + 80 °C (maximum temperature 40 °C if the motor and/or
the fan bearings are in the air stream)
3.7.2
special purpose fan
fan used for special operating conditions (see 3.7.2.1 to 3.7.2.11)
NOTE 1 A fan may have a combination of special features.
NOTE 2 The operating conditions stated below represent a typical range, but the list is not necessarily complete. Other types
having special features to suit specific applications should be agreed between the manufacturer and purchaser.
3.7.2.1
hot gas fan
fan used for handling hot gases continuously
NOTE 1 Special materials shall be incorporated as necessary for the fan which may have a direct or indirect drive.
NOTE 2 The motor on a direct-drive fan may be either in the air stream or separated from it.
NOTE 3 Indirect-drive fans should incorporate a means for cooling belts, bearings or other drive components where
necessary (see 5.3.2 for designation).
4

---------------------- Page: 14 ----------------------

SIST EN ISO 13349:2009
© ISO
ISO 13349:1999(E)
3.7.2.2
smoke-ventilating fan
fan suitable for handling hot smoke for a specified time/temperature profile
NOTE 1 Special materials are incorporated as necessary for the fan, which may have a direct or indirect drive.
NOTE 2 The motor may be either in the air stream on a direct-drive fan, or separated from it.
NOTE 3 Indirect-drive fans incorporate a means for cooling belts, bearings or other drive components where necessary (see
5.3.3 for categorization).
3.7.2.3
wet-gas fan
fan suitable for handling air containing particles of water or any other liquid
3.7.2.4
gas-tight fan
fan with a suitable sealed casing to match a specified leakage rate at a specified pressure
NOTE Depending upon the leakage specification, this can involve special attention being paid to all services which
penetrate the casing, such as inspection means, lubricator fittings and electrical supply, as well as the details of the connecting
flanges (see 5.3.4 for categorization).
3.7.2.5
dust fan
fan suitable for handling dust-laden air, designed to suit the dust being handled
3.7.2.6
conveying fan
transport fan
fan suitable for the conveying of solids (e.g. wood chips, textile waste, pulverized materials) and dust entrained in
the air stream, designed to suit the material being conveyed
NOTE A conveying/transport fan may be of direct or indirect type, depending on whether or not the handled material
passes through the impeller.
3.7.2.7
nonclogging fan
fan having an impeller designed to minimize clogging by virtue of its detailed shape, or by the use of special
materials
NOTE The fan may also incorporate other features to allow the use of cleaning sprays and to facilitate the removal of any
material.
3.7.2.8
abrasion-resistant fan
fan designed to minimize abrasion, having parts that are especially subject to wear constructed in suitable abrasion-
resistant materials and/or easily replaceable
3.7.2.9
corrosion-resistant fan
fan constructed in suitable corrosion-resistant materials or suitably treated to minimize corrosion by specified agents
3.7.2.10
spark-resistant fan
ignition-protected fan
fan with features designed to minimize the risk of sparks or hot spots resulting from contact between moving and
stationary parts that may cause the ignition of dust or gases
NOTE No bearings, drive components or electrical devices should be placed in the air or gas stream, unless they are
constructed in such a manner that failure of that component cannot ignite the surrounding gas stream (see 5.3.4 for
categorization).
5

---------------------- Page: 15 ----------------------

SIST EN ISO 13349:2009
© ISO
ISO 13349:1999(E)
3.7.2.11
powered roof ventilator
fan designed for mounting on a roof and having exterior weather protection
3.8  Fan elements
3.8.1
fan inlet
opening, usually circular or rectangular, through which the air first enters the fan casing
NOTE 1 If the fan is provided with an inlet-connecting flange or spigot, the fan inlet dimensions are measured inside this
connection. The inlet area is the gross area measured inside this flange, i.e. no deductions are made for blockages such as
motors, bearing supports, etc.
NOTE 2 When the inlet area is not clearly defined, it should be agreed between the parties to the contract.
3.8.2
fan outlet
opening, usually circular or rectangular, through which the air finally leaves the fan casing
NOTE 1 If the fan is provided with an outlet connecting flange or spigot, the fan outlet dimensions are measured inside this
connection. When the fan is delivered with a diffuser and the performance is quoted with this fitted, the area of the fan outlet is
to be taken as equal to the outlet area of the diffuser.
NOTE 2 When the outlet area is not clearly defined, it should be agreed between the parties to the contract.
NOTE 3 For the special requirements of jet fans, see ISO 13350.
3.8.3
impeller tip diameter
maximum diameter measured over the tips of the blades of the impeller (see ISO 13351)
3.8.4
size designation
nominal impeller tip diameter, defined as the impeller tip diameter on which the design of that fan is based
4 Units and symbols
The following primary units and symbols for the parameters listed shall be used.
Parameter Symbol Unit
3
Volume flowrate q m /s
v
Fan pressure Pa
p
F
Power P W
Torque Nm
3
Gas density r kg/m
Impeller tip speed u m/s
Outlet or duct velocity v m/s
Rotational frequency n r/s
Rotational speed N r/min
Dimensions mm
2
Moment of inertia kg×m
Stress Pa
Energy kJ
Temperature q K
Work per unit mass y kJ/kg
Thrust kN
6

---------------------- Page: 16 ----------------------

SIST EN ISO 13349:2009
© ISO
ISO 13349:1999(E)
4.1 Multiples of primary units
The choice of the appropriate multiple or submultiple of an SI unit is governed by convenience. The multiple chosen
for a particular application shall be that which will lead to numerical values within a practical range (e.g. kilopascal
for pressure, kilowatts for power and megapascal for stress).
4.2 Units of time
The second is the SI base unit of time, although outside SI the minute has been recognized by CIPM as necessary
to retain for use because of its practical importance. Manufacturers may, therefore, continue with the use of r/min
for rotational speed.
4.3 Temperature of air/gas
The kelvin is the SI base unit of thermodynamic temperature and is preferred for most scientific and technological
purposes. The degree Celsius (°C) is acceptable for practical applications.
5 Fan categories
5.1 General
Fans may be categorized according to:
a) suitability for the fan pressure;
b) suitability of construction (including features required for smoke ventilation, gas tightness and ignition
protection);
c) driving arrangement;
d) inlet and outlet conditions;
e) method of fan control;
f) rotation and position of parts;
g) characteristic dimensions.
Examples of the use of the definitions and categories to identify a fan in a specification are given in annex A.
5.2 Suitability for the fan pressure
A fan may also be defined as being low, medium or high pressure, according to the level of work per unit mass, and
whether the influence of compressibility of the air or gas being handled has to be taken into account. For a detailed
account of these considerations, refer to ISO 5801.
A low-pressure fan is then defined as having a pressure ratio less than 1,02 and a reference Mach No. of less than
0,15. This corresponds to a pressure rise of less than 2 kPa when handling standard air.
A medium-pressure fan is defined as having a pressure ratio greater than 1,02 and less than 1,1. The reference
Mach No. shall be less than 0,15. This corresponds to a pressure rise of 2 kPa to 10 kPa.
A high-pressure fan is defined as having a pressure ratio and pressure rise greater than the above.
5.2.1 Work per unit mass
A convention is used for all industrial fans except jet fans (see ISO 13350), denoting the work per unit mass as the
quotient of air power and mass flowrate. The fan pressure is approximately equal to the product of work per unit
mass and the mean stagnation density of the fluid within the fan.
7

---------------------- Page: 17 ----------------------

SIST EN ISO 13349:2009
© ISO
ISO 13349:1999(E)
5.2.2 Fan categories
Depending on its peripheral speed, a fan impeller will develop more or less pressure. This International Standard
defines a range of "fan categories" where the fan pressure at maximum efficiency and maximum rotational speed is
not less than the value given in table 1. In any event, this defined fan pressure shall not exceed 95 % of the
maximum pressure developed by the fan at its maximum speed.
5.2.3 Changes in air density
These categories shall also be used to indicate whether or not the change in air density within the fan shall be
considered. For a low-pressure fan this change may be neglected. For a high-pressure fan, this change shall not be
neglected, whereas for a medium-pressure fan, it may or may not be neglected depending on the desired accuracy.
Detailed mechanical design and construction of the rotational elements will be determined by the peripheral speed
and, therefore, the pressure for which the fan is specified.
Table 1 — Categorization of fan according to level of work per unit mass
Work per unit mass “Maximum” fan pressure
Fan
Code Category
(for standard air)
description
kJ/kg kPa
Low pressure L > 0 and < 0,6 > 0 and < 0,7 0
> 0,6 and < 0,83 > 0,7 and < 11
> 0,83 and < 1,33 > 1 and < 1,6 2
> 1,33 and < 1,67 > 1,6 and < 2,0 3
Medium pressure M > 1,67 and < 3 > 2,0 and < 3,6 4
> 3 and < 5,25 > 3,6 and < 6,3 5
> 5,25 and < 8,33 > 6,3 and < 10 6
High pressure H > 8,33 and < 13,33 > 10 and < 16 7
> 13,33 and < 18,67 > 16,0 and < 22,4 8
> 18,67 and < 25 >22,4 and < 30 9
Turbocompressors > 25 > 30
5.3 Suitability of construction
5.3.1 Categorization according to casing construction
Fans are used for a variety of purposes (see 3.7). The air or gas handled may be clean or contain moisture or solid
particles and may be at ambient or other temperature. Connection to its associated ducting can be via flexible
elements or alternatively it may be attached directly, such that the casing has to withstand additional loads due to
the dead weight of these connections. Where a high or low temperature is present, further loading can result from
the effects of expansion or contraction. Casing thickness and/or stiffening are also determined by the ability to
withstand the specified fan pressure and dynamic loads and by the need for a margin to counter the effects of any
erosion or corrosion. For all these and other reasons, different methods of casing construction and different casing
thicknesses are appropriate to the application.
The categorization in table 2 reflects current practice and shall be used only to assist specification. It in no way
indicates any form of grading. Category 1 is as valid for clean air ventilation as Category 3 is preferred for heavy
industrial requirements.
8

---------------------- Page: 18 ----------------------

SIST EN ISO 13349:2009
© ISO
ISO 13349:1999(E)
Table 2 — Categorization according to method of casing construction
Casing
Category Typical casing features Usage
thickness
1 Lockformed, spot welded or screwed — Light HVAC < 0,0025 D
construction. Cradle or angle frame
mounting Clean air
2 Lockformed, seam welded or continuously — Heavy HVAC > 0,0025 D
welded construction. Semi-universal
design with bolted on side-plates — Light industrial
Light dust or moisture
3 Fully welded fixed discharge — Heavy industrial > 0,00333 D
• Dirty air containing
moisture and/or solids, or
• High pressure, or
• High power
NOTE D is the nominal impeller diameter, in millimetres.
5.3.2 Designation for hot-gas fan
Where a fan is suitable for continuous operation up to a stated maximum temperature (hot gas fan, see 3.7.2.1), this
should be indicated on the conventional fan rating plate itself.
The following designation shall be used:
T, followed by the maximum temperature, in degrees Celsius, for continuous operation.
EXAMPLE  T/500 denotes a fan rated for a maximum continuous temperature of 500 °C.
5.3.3 Designation and recommended categorization for smoke-ventilating fans (see 3.7.2.2)
If the fan is also, or only, capable of short-term operation at a high temperature, this information shall be clearly
stated on a separate label.
The following designation shall be used:
HT, followed by temperature in degrees Celsius and time, at the stated temperature, in hours or decimals of an
hour.
EXAMPLE  HT/300/0,5, denotes "a high-temperature fan rated for operation at 300 °C for 0,5 h (i.e. 30 min)".
The recommended categories for smoke-ventilating fan are given in table 3.
9

---------------------- Page: 19 ----------------------

SIST EN ISO 13349:2009
© ISO
ISO 13349:1999(E)
Table 3 — Recommended categorization of smoke-ventilating fans
Temperature Coding Maximum Minimum
category air/gas temperature operating time
°C h
A HT/150/5,0 150 5,0
B HT/200/2,0 200 2,0
C HT/250/1,0 250 1,0
D HT/300/1,0 300 1,0
E HT/400/2,0 400 2,0
F HT/600/1,5 600 1,5
G HT/850/1,0 850 1,0
5.3.4 Categorization for gas-tight fans (see 3.7.2.4)
Gas-tight fans shall be categorized in accordance with table 4. The amount of leakage is dependent on the pressure
within the fan casing and the time for which this must be maintained. The leakage rate is obtained by blocking off
the fan inlet and outlet and 'pumping up' or extracting the casing using an auxiliary
...