SIST EN ISO 4619:2019
(Main)Driers for paints and varnishes (ISO 4619:2018)
Driers for paints and varnishes (ISO 4619:2018)
This document specifies the requirements and the corresponding test methods for driers for paints,
varnishes and related products. It applies to driers in the solid or liquid form. It does not apply to
emulsifiable driers.
Trockenstoffe für Beschichtungsstoffe (ISO 4619:2018)
Dieses Dokument legt die Anforderungen und die entsprechenden Prüfverfahren für Trockenstoffe für Beschichtungsstoffe und ähnliche Produkte fest. Die Anforderungen beziehen sich auf feste oder flüssige Trockenstoffe. Sie beziehen sich nicht auf emulgierbare Trockenstoffe.
Siccatifs pour peintures et vernis (ISO 4619:2018)
Le présent document fixe des spécifications et les méthodes d'essai correspondantes des siccatifs pour peintures, vernis et produits assimilés. Il s'applique aux siccatifs sous forme solide ou liquide. Il ne s'applique pas aux siccatifs émulsionnables.
Sušilniki za barve in lake (ISO 4619:2018)
Ta dokument določa zahteve in ustrezne preskusne metode za sušilnike za barve, lake in sorodne izdelke. Uporablja se za sušilnike v trdni ali tekoči obliki. Ne uporablja se za emulzivne sušilnike.
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN ISO 4619:2019
01-marec-2019
1DGRPHãþD
SIST EN ISO 4619:2012
SIST ISO 4619:1998
Sušilniki za barve in lake (ISO 4619:2018)
Driers for paints and varnishes (ISO 4619:2018)
Trockenstoffe für Beschichtungsstoffe (ISO 4619:2018)
Siccatifs pour peintures et vernis (ISO 4619:2018)
Ta slovenski standard je istoveten z: EN ISO 4619:2018
ICS:
87.100 Oprema za nanašanje Paint coating equipment
premazov
SIST EN ISO 4619:2019 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN ISO 4619:2019
---------------------- Page: 2 ----------------------
SIST EN ISO 4619:2019
EN ISO 4619
EUROPEAN STANDARD
NORME EUROPÉENNE
December 2018
EUROPÄISCHE NORM
ICS 87.060.99 Supersedes EN ISO 4619:2010
English Version
Driers for paints and varnishes (ISO 4619:2018)
Siccatifs pour peintures et vernis (ISO 4619:2018) Trockenstoffe für Beschichtungsstoffe (ISO 4619:2018)
This European Standard was approved by CEN on 4 November 2018.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2018 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 4619:2018 E
worldwide for CEN national Members.
---------------------- Page: 3 ----------------------
SIST EN ISO 4619:2019
EN ISO 4619:2018 (E)
Contents Page
European foreword . 3
2
---------------------- Page: 4 ----------------------
SIST EN ISO 4619:2019
EN ISO 4619:2018 (E)
European foreword
This document (EN ISO 4619:2018) has been prepared by Technical Committee ISO/TC 35 "Paints and
varnishes" in collaboration with Technical Committee CEN/TC 139 “Paints and varnishes” the
secretariat of which is held by DIN.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by June 2019, and conflicting national standards shall be
withdrawn at the latest by June 2019.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN ISO 4619:2010.
According to the CEN-CENELEC Internal Regulations, the national standards organizations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria,
Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia,
France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta,
Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.
Endorsement notice
The text of ISO 4619:2018 has been approved by CEN as EN ISO 4619:2018 without any modification.
3
---------------------- Page: 5 ----------------------
SIST EN ISO 4619:2019
---------------------- Page: 6 ----------------------
SIST EN ISO 4619:2019
INTERNATIONAL ISO
STANDARD 4619
Third edition
2018-11
Driers for paints and varnishes
Siccatifs pour peintures et vernis
Reference number
ISO 4619:2018(E)
©
ISO 2018
---------------------- Page: 7 ----------------------
SIST EN ISO 4619:2019
ISO 4619:2018(E)
COPYRIGHT PROTECTED DOCUMENT
© ISO 2018
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting
on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address
below or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Fax: +41 22 749 09 47
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii © ISO 2018 – All rights reserved
---------------------- Page: 8 ----------------------
SIST EN ISO 4619:2019
ISO 4619:2018(E)
Contents Page
Foreword .v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Descriptions . 2
4.1 Solid driers . 2
4.2 Liquid driers . 2
4.3 Metals used . 2
4.4 Acids used. 2
5 Requirements and test methods . 2
6 Sampling . 3
7 Methods of test for solid driers . 3
7.1 Appearance and consistency. 3
7.2 Colour . 3
7.3 Solubility (miscibility) in solvents, raw linseed oil or other drying media. 4
7.4 Stability of solution . 4
7.5 Suspended solid matter . 4
7.6 Volatile matter . 5
7.7 Acidity . 5
7.7.1 Principle . 5
7.7.2 Reagents . 5
7.7.3 Apparatus . 5
7.7.4 Preparation of the ion-exchange column . 6
7.7.5 Procedure . 7
7.7.6 Expression of results . 7
8 Methods of test for liquid driers . 7
8.1 Appearance . 7
8.2 Colour . 7
8.3 Solubility (miscibility) in solvents, raw linseed oil or other drying media. 7
8.4 Stability of solution . 8
8.5 Viscosity . 8
9 Methods for determination of metal content of driers containing only one metal .9
9.1 General . 9
9.2 Cobalt [ethylene diaminetetraacetic acid (EDTA) titrimetric method] . 9
9.2.1 Reagents . 9
9.2.2 Procedure .10
9.2.3 Expression of results .10
9.3 Manganese (EDTA titrimetric method) .11
9.3.1 Reagents .11
9.3.2 Procedure .11
9.3.3 Expression of results .11
9.4 Zinc (EDTA titrimetric method) .12
9.4.1 Reagents .12
9.4.2 Procedure .12
9.4.3 Expression of results .12
9.5 Calcium (EDTA titrimetric method) .12
9.5.1 Reagents .12
9.5.2 Procedure .13
9.5.3 Expression of results .13
9.6 Iron (Iodometric method) .13
9.6.1 Principle .14
© ISO 2018 – All rights reserved iii
---------------------- Page: 9 ----------------------
SIST EN ISO 4619:2019
ISO 4619:2018(E)
9.6.2 Reagents .14
9.6.3 Procedure .14
9.6.4 Expression of results .15
9.7 Zirconium (EDTA titrimetric method) .15
9.7.1 Reagents .15
9.7.2 Procedure .15
9.7.3 Expression of results .16
9.8 Barium .16
9.8.1 General.16
9.8.2 Method A (gravimetric method) .16
9.8.3 Method B (acidimetric method) .17
10 Methods for determination of metal contents of mixed driers .18
11 Test report .19
Bibliography .20
iv © ISO 2018 – All rights reserved
---------------------- Page: 10 ----------------------
SIST EN ISO 4619:2019
ISO 4619:2018(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www .iso .org/directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www .iso .org/patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and
expressions related to conformity assessment, as well as information about ISO's adherence to the
World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT) see www .iso
.org/iso/foreword .html.
This document was prepared by Technical Committee ISO/TC 35, Paints and varnishes.
This third edition cancels and replaces the second edition (ISO 4619:1998), which has been technically
revised. The main changes compared to the previous edition are as follows:
— the concentration of phenolphthalein indicator solution in 7.7.2.6 has been reduced to 0,5 % following
actual requirements;
— the determination of lead has been deleted;
— the normative references have been updated;
— the text has been editorially revised.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www .iso .org/members .html.
© ISO 2018 – All rights reserved v
---------------------- Page: 11 ----------------------
SIST EN ISO 4619:2019
---------------------- Page: 12 ----------------------
SIST EN ISO 4619:2019
INTERNATIONAL STANDARD ISO 4619:2018(E)
Driers for paints and varnishes
CAUTION — The procedures described in this document are intended to be carried out by
qualified chemist or by other suitably trained and/or supervised personnel. The substances and
procedures used in this document can be injurious to health if adequate precautions are not
taken. It is the responsibility of the user of this document to establish appropriate health and
safety practices prior to its use.
Attention is particularly drawn to the health hazards of heavy metals which might be a
constituent of driers (e.g. cobalt, cerium, zirconium, vanadium).
1 Scope
This document specifies the requirements and the corresponding test methods for driers for paints,
varnishes and related products. It applies to driers in the solid or liquid form. It does not apply to
emulsifiable driers.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
ISO 150, Raw, refined and boiled linseed oil for paints and varnishes — Specifications and methods of test
ISO 1523, Determination of flash point — Closed cup equilibrium method
ISO 2592, Petroleum and related products — Determination of flash and fire points — Cleveland open
cup method
ISO 2811-1, Paints and varnishes — Determination of density — Part 1: Pycnometer method
ISO 3251, Paints, varnishes and plastics — Determination of non-volatile-matter content
ISO 3696, Water for analytical laboratory use — Specification and test methods
ISO 4618, Paints and varnishes — Terms and definitions
ISO 15528, Paints, varnishes and raw materials for paints and varnishes — Sampling
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 4618 and the following apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https: //www .iso .org/obp
— IEC Electropedia: available at http: //www .electropedia .org/
3.1
drier
compound, usually a metallic soap, that is added to products drying by oxidation in order to accelerate
this process
© ISO 2018 – All rights reserved 1
---------------------- Page: 13 ----------------------
SIST EN ISO 4619:2019
ISO 4619:2018(E)
4 Descriptions
4.1 Solid driers
Solid driers are materials which can be manufactured in a hard, soft (highly viscous) or powder form.
4.2 Liquid driers
Liquid driers are materials which are supplied as solutions in organic solvents, usually white spirit.
All these types of driers, when dissolved in solvents (normally hydrocarbons), impart specific drying
properties depending on the metal used.
4.3 Metals used
The following metals are normally used: cobalt, manganese, zinc, calcium, cerium (or other rare earths),
iron, zirconium, vanadium, barium, aluminium, strontium, etc.
NOTE In this document, methods for determination of metal content are given only for those metals which
are in common use.
4.4 Acids used
The following acids are used: fatty acids of linseed oils, tall-oil fatty acids, resinic acids, naphthenic
acids, 2-ethylhexanoic acid, fatty iso-acids with 9 carbon atoms, other fatty acids with 9 to 11 carbon
atoms, etc.
5 Requirements and test methods
5.1 Driers for paints shall conform to the requirements given in Table 1.
Table 1 — Requirements and test methods
Test method
Characteristic Requirement
Solid driers Liquid driers
Clear and uniform;
Appearance no suspended matter 7.1 8.1
or sediment
As agreed between To be agreed
Consistency, if required the interested parties between the —
interested parties
As agreed between
Colour 7.2 8.2
the interested parties
Solubility (miscibility) in solvent, raw lin- No separation or
7.3 8.3
seed oil and other drying media deposit
Clear solution; no
Stability of solution clouding, gelation or 7.4 8.4
sedimentation
of liquid driers
max. 0,1 — 7.5
Suspended solid % (mass fraction)
matter
As agreed between
of solid driers 7.5 —
the interested parties
a
Tolerance (absolute value) on the metal content declared or agreed.
2 © ISO 2018 – All rights reserved
---------------------- Page: 14 ----------------------
SIST EN ISO 4619:2019
ISO 4619:2018(E)
Table 1 (continued)
Test method
Characteristic Requirement
Solid driers Liquid driers
As agreed between
Viscosity, only for liquid driers — 8.5
the interested parties
As agreed between
Volatile matter at 105 °C 7.6 7.6
the interested parties
As agreed between
Flashpoint ISO 2592 ISO 1523
the interested parties
As agreed between To be agreed
Density the interested parties between the ISO 2811-1
interested parties
As agreed between
Acidity or basicity 7.7 7.7
the interested parties
As agreed between To be agreed To be agreed
Drying characteristics the interested parties between the between the
interested parties interested parties
±0,2 % (mass
up to 10 % (mass fraction)
a
fraction)
above 10 % (mass fraction) ±0,3 % (mass
a
to 20 % (mass fraction) fraction)
Metal content
Clause 9 or Clause 10
(range)
above 20 % (mass fraction) ±0,4 % (mass
a
to 30 % (mass fraction) fraction)
±0,5 % (mass
above 30 % (mass fraction)
a
fraction)
a
Tolerance (absolute value) on the metal content declared or agreed.
5.2 Driers named according to the commercial name of the main acid used shall contain at least 90 %
of this acid, except for driers based on naphthenic acids, which shall contain at least 70 % of these acids,
expressed as a percentage of the total mass of acid present.
NOTE The type and content of the acids can be determined by gas-chromatographic (GC) analysis, except in
the case of naphthenic acids.
6 Sampling
Take a representative sample of the drier to be tested, as specified in ISO 15528.
7 Methods of test for solid driers
During the analysis, use only reagents of recognized analytical grade and only water of at least grade 3
purity in accordance with ISO 3696.
7.1 Appearance and consistency
Examine the sample visually for uniformity. If the consistency is specified, a method for its
determination shall be agreed between the interested parties.
7.2 Colour
Dissolve 1 part by mass of the drier in 1 part by mass of white spirit or other agreed solvent and
compare the colour against an agreed sample or colour standard.
© ISO 2018 – All rights reserved 3
---------------------- Page: 15 ----------------------
SIST EN ISO 4619:2019
ISO 4619:2018(E)
7.3 Solubility (miscibility) in solvents, raw linseed oil or other drying media
Slowly heat, raising the temperature at a rate of 1 °C/min, 5 g of the drier and 20 g of an agreed solvent
(or drying medium) under reflux on a sand bath, with stirring, until a homogeneous solution is obtained.
Allow to cool to room temperature and examine the solution for clarity, clouding and any separation or
deposit.
7.4 Stability of solution
Allow 3 portions of the solution obtained by the method specified in 7.3 to stand for 7 days in stoppered
bottles, one at each of the following temperatures:
a) 0 °C;
b) ambient temperature;
c) 50 °C.
After 1 day and again after 7 days, examine the solutions for clarity, clouding sedimentation or gelation.
The bottle used for the test at 50 °C shall be able to withstand the pressure generated.
7.5 Suspended solid matter
Weigh, to the nearest 0,1 g, 5 g of solid drier (or 10 g of liquid drier) into a glass flask and dissolve in
(or dilute with) 100 g of white spirit or an agreed solvent. Stopper the flask, allow to stand at ambient
temperature for 3 days, then filter off the sediment or suspended matter using a glass filter crucible of
porosity P 16 (see ISO 4793). Wash the residue on the filter with the solvent and dry it at 105 °C for 3 h.
Cool to ambient temperature and weigh to the nearest 1 mg.
Calculate the suspended solid matter SSM, as a percentage mass fraction, using Formula (1):
m
1
SSM=×100 (1)
m
0
4 © ISO 2018 – All rights reserved
---------------------- Page: 16 ----------------------
SIST EN ISO 4619:2019
ISO 4619:2018(E)
where
m is the mass, in grams, of the test portion;
0
m is the mass, in grams, of the residue.
1
7.6 Volatile matter
Proceed in accordance with ISO 3251, taking a flat-bottomed glass of aluminium dish and a test portion
of (1,00 ± 0,02) g. Place the dish with the test portion in the air oven, maintained at (105 ± 2) °C. Leave it
in the oven at this temperature for 3 h.
7.7 Acidity
7.7.1 Principle
A solution of the drier in toluene/propan-2-ol is passed through a strong acid cation exchanger and the
total acid in the eluate is determined. From the total acid determined, the acid combined with the metal
is subtracted.
If a negative value for the acidity is obtained, the
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.