This European Standard gives requirements and the corresponding test/assessment methods applicable to leak detection kits (leak detector) based on the measurement of pressure change. Leak detection kits are intended to be used with double skin, underground or above ground, pressurized or non-pressurized, tanks or pipework designed for water polluting liquids/fluids. The kits are usually composed of:
-   measuring device;
-   evaluation device;
-   alarm device;
-   pressure generator;
-   pressure relief device;
-   liquid stop device;
-   condensate trap.

  • Standard
    66 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard gives requirements and the corresponding test/assessment methods applicable to leak detection lining kits and leak detection jacket kits. Leak detection lining kits and leak detection jackets kits intended to be used as post-installed to create an interstitial space or leakage containment in single skin underground or above ground, non-pressurized, tanks designed for water polluting liquids. The kit has to be used only in conjunction with leak detection kits covered by prEN 13160-2 to prEN 13160-4.

  • Standard
    51 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard gives requirements and the corresponding test/assessment methods applicable to leak detection kits based on the detection of the presence of liquid and/or vapour in interstitial spaces, leakage containments or monitoring wells. The kits are usually composed by:
- sensing device(s);
- evaluation device;
- alarm device.

  • Standard
    38 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the general principles for leak detection systems for use with double-skin tanks, single-skin tanks and pipework designed for water polluting fluids.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard gives requirements and the corresponding test/assessment methods applicable to leak detection kits based on the drop of the liquid level in the leak detection liquid reservoir. Leak detection kits are intended to be used with double skin, underground or above ground, non-pressurized, tanks designed for water polluting liquids.
The liquid leak detection kits are usually composed of:
- sensing device (liquid sensor);
- evaluation device;
- alarm device.

  • Standard
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard gives requirements and corresponding test\assessment methods applicable to leak detection kits, based upon volumetric loss from within the tank and/or pipework system. The kits usually comprise:
- Measuring Device
- Evaluation Device
- Alarm Device
Intended use:
Leak Detection kits are intended to be used in\with single or double skin underground tanks or single or double skin underground and/or aboveground, pipework designed for flammable liquids having a flash point not exceeding 100 °C.

  • Standard
    73 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for leak detection systems - class V for use with systems designed for fuels which are flammable, having a flash point up to but not exceeding 100 °C.

  • Standard
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the general principles for leak detection systems for use with double-skin
tanks, single-skin tanks and pipework designed for water polluting fluids.

  • Draft
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for leak detection systems – class II for use with doubleskin
tanks designed for water polluting fluids.

  • Draft
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This draft European Standard specifies the requirements for leak detection systems, class IV, for use only with liquids as defined in the scope of EN 13352:2002.

  • Draft
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2009-05-12 EMA: CEN/TC 221 disbanded by resolution BT C88/2008. The work of CEN/TC 221/SC 2 is transfered to CEN/TC 393.
CMC - Modification to A.4.5 (editorial error)

  • Corrigendum
    2 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements for leak detection systems - class IV for use only with liquids as defined in the scope of EN 13352.

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies the requirements for leak detection systems - class II for use with double-skin systems designed for water polluting fluids.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies the requirements for leak detection systems - class I for use with double-skin systems, designed for water polluting fluids.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies the general principles for leak detection systems for use with double-skin tanks, single-skin tanks and pipework designed for water polluting fluids.

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies the requirements for leak detection systems - class III for use in the interstitial space of double-skin systems or in leakage containments of single skin systems designed for water polluting fluids.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies the type test of the interstitial space and the general requirements and test methods for leak protecting linings and leak protecting jackets which are parts of leak detection systems.

  • Standard
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies the requirements for leak detection systems - class V for use with systems designed for fuels which are flammable having a flash point up to but not exceeding 100 °C.

  • Standard
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day