CEN/TC 165/WG 4 - Gullies and tops a.s.o.
To establish European Standards for gullies (e.g. street gullies), drainage channels, gully tops, manhole tops (e.g. covers/gratings for manholes and inspection chambers), and other ancillary components (e.g. fixed ladders, steps etc.) including requirements, testing and quality control.
Gullies and tops a.s.o.
To establish European Standards for gullies (e.g. street gullies), drainage channels, gully tops, manhole tops (e.g. covers/gratings for manholes and inspection chambers), and other ancillary components (e.g. fixed ladders, steps etc.) including requirements, testing and quality control.
General Information
This European Standard is applicable to gully tops and manhole tops made of mild steel, stainless steel and aluminium alloys whether in combination with concrete or not, with a clear opening up to and including 1 000 mm for covering gullies, manholes and inspection chambers for installation in areas subjected to pedestrian and/or vehicular traffic.
It is applicable to manhole tops and gully tops for use in:
- areas which can only be used by pedestrians and pedal cyclists (at least class A 15),
- pedestrian areas and comparable areas, car parks or car parking decks (at least class B 125),
- the area of kerbside channels of roads which, when measured from the kerb edge, extends a maximum of 0,5 m into the carriageway and a maximum of 0,2 m into the pedestrian area (at least class C 250),
- carriageways of roads (including pedestrian streets), hard shoulders and parking areas, for all types of road vehicles (at least class D 400),
- areas imposing high wheel loads, e.g. docks, aircraft pavements (at least class E 600),
- areas imposing particularly high wheel loads, e.g. aircraft pavements (class F 900).
This European Standard is not applicable in isolation but only in combination with EN 124 1 and gives guidance for combinations of covers/gratings made from steel or aluminium alloys with frames according to EN 124 2 and EN 124 4, EN 124 5 and EN 124 6.
Fabrication of manhole tops and gully tops in accordance with this standard is limited to cold forming, mechanical crimping or welding together component parts made from metal plate, strip or bar or rolled or extruded metal sections.
This European Standard is not applicable to:
- manhole tops and gully tops made of aluminium tread plates for use in carriageways of roads (class D 400) and areas imposing high wheel loads (Classes E 600 and F 900),
- concave gratings for classes D 400 installed in carriageways of roads and hard shoulders and concave gratings for classes F 900 and E 600.
- gratings/covers as part of prefabricated drainage channels according to EN 1433,
- floor and roof gullies in buildings which are specified in EN 1253 (all parts), and
- surface boxes.
- Standard36 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard is applicable to gully tops and manhole tops made of flake graphite cast iron and/or spheroidal graphite cast iron whether in combination with concrete or not, with a clear opening up to and including 1 000 mm for covering gullies, manholes and inspection chambers for installation within areas subjected to pedestrian and/or vehicular traffic.
It is applicable to manhole tops and gully tops for use in:
- areas which can only be used by pedestrians and pedal cyclists (at least class A 15),
- pedestrian areas and comparable areas, car parks or car parking decks (at least class B 125),
- the area of kerbside channels of roads which, when measured from the kerb edge, extends a maximum of 0,5 m into the carriageway and a maximum of 0,2 m into the pedestrian area (at least class C 250),
- carriageways of roads (including pedestrian streets), hard shoulders and parking areas, for all types of road vehicles (at least class D 400),
- areas imposing high wheel loads, e.g. docks, aircraft pavements (at least class E 600),
- areas imposing particularly high wheel loads, e.g. aircraft pavements (class F 900).
This European Standard is not applicable in isolation but only in combination with EN 124 1 and gives guidance for combinations of covers/grating made from cast iron with frames according to EN 124 3, EN 124 4, EN 124 5 and EN 124 6.
This European Standard is not applicable to:
- fillings installed on site, e.g. concrete, paving blocks, etc.,
- concave gratings for classes D 400 installed in carriageways of roads and hard shoulders and concave gratings for classes F 900 and E 600,
- gratings/covers as part of prefabricated drainage channels according to EN 1433,
- floor and roof gullies in buildings which are specified in EN 1253 (all parts), and
- surface boxes.
- Standard32 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard is applicable to manhole tops and gully tops with a clear opening up to and including 1 000 mm for covering gullies, manholes and inspection chambers installed in areas subjected to pedestrian and/or vehicular traffic. It specifies definitions, classification, general principles of design, performance requirements and test methods for gully tops and manhole tops according to:
- EN 124 2, for gully tops and manhole tops made of cast iron;
- EN 124 3, for gully tops and manhole tops made of steel or aluminium alloy;
- EN 124 4, for gully tops and manhole tops made of steel reinforced concrete;
- EN 124 5, for gully tops and manhole tops made of composite materials;
- EN 124 6, for gully tops and manhole tops made of polypropylene (PP), polyethylene (PE) or unplasticized poly(vinyl chloride) (PVC-U).
Part 1 is only applicable in combination with at least one of the standards EN 124 2, EN 124 3, EN 124 4, EN 124 5 and EN 124 6 each of which has this Part 1 as an integral part.
This European Standard is not applicable to:
- gratings/covers as part of prefabricated drainage channels according to EN 1433,
- floor and roof gullies in buildings which are specified in EN 1253 1,
- surface boxes.
- Standard45 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard is applicable to manhole tops and gully tops made of composite materials C1, C2 and C3 by using suitably controlled automatic processes that produce a single structure and that do not contain multiple pieces bonded together, with a clear opening up to and including 1 000 mm for covering gullies, manholes and inspection chambers for installation within areas subjected to pedestrian and/or vehicular traffic.
It is applicable to manhole tops and gully tops for use in:
- areas which can only be used by pedestrians and pedal cyclists (class A 15),
- pedestrian areas and comparable areas, car parks or car parking decks (class B 125),
- the area of kerbside channels of roads which, when measured from the kerb edge, extends a maximum of 0,5 m into the carriageway and a maximum of 0,2 m into the pedestrian area (class C 250),
and in addition to manhole tops for use in
- carriageways of roads (including pedestrian streets), hard shoulders and parking areas, for all types of road vehicles (class D 400).
This European Standard is not applicable in isolation but only in combination with EN 124-1 and gives guidance for combinations of covers/gratings made from composite materials with frames according to EN 124-2, EN 124-3, EN 124-4 and EN 124-6.
This document is not applicable to:
- manhole tops and gully tops manufactured by means of hand lay-up method,
- gratings/covers as part of prefabricated drainage channels according to EN 1433,
- floor and roof gullies in buildings which are specified in EN 1253 (all parts), and
- surface boxes.
- Standard38 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard is applicable to precast gully tops and manhole tops made of steel reinforced concrete with a clear opening up to and including 1 000 mm for covering gullies, manholes and inspection chambers for installation within areas subjected to pedestrian and/or vehicular traffic.
It is applicable to manhole tops and gully tops for use in
- areas which can only be used by pedestrians and pedal cyclists (at least class A 15),
- pedestrian areas and comparable areas, car parks or car parking decks (at least class B 125),
- the area of kerbside channels of roads which, when measured from the kerb edge, extends a maximum of 0,5 m into the carriageway and a maximum of 0,2 m into the pedestrian area (at least class C 250),
- carriageways of roads (including pedestrian streets), hard shoulders and parking areas, for all types of road vehicles (at least class D 400),
- areas imposing high wheel loads, e.g. docks, aircraft pavements (at least class E 600),
- areas imposing particularly high wheel loads, e.g. aircraft pavements (Group 6, class F 900).
This European Standard is not applicable in isolation but only in combination with EN 124 1 and gives guidance for combinations of covers/gratings made of steel reinforced concrete with frames according to EN 124 2, EN 124 3, EN 124 5 and EN 124 6.
This European Standard is not applicable to:
- concave gratings for class D 400 installed in carriageways of roads and hard shoulders and concave gratings for classes F 900 and E 600;
- gratings/covers as part of prefabricated drainage channels according to EN 1433;
- floor and roof gullies in buildings which are specified in EN 1253 (all parts); and
- surface boxes.
- Standard32 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard applies to manhole tops and gully tops made of Polypropylene (PP), Polyethylene (PE) or unplasticized poly(vinyl chloride) (PVC-U) by a moulding or extrusion process, with a clear opening up to and including 1 000 mm for covering gullies, manholes and inspection chambers for installation within areas subjected to pedestrian and/or vehicular traffic.
It is applicable to manhole tops and gully tops for use in
- areas which can only be used by pedestrians and pedal cyclists (class A 15), and
- pedestrian areas and comparable areas, car parks or car parking decks (class B 125).
This European Standard gives guidance for combinations of covers/grating made of PP, PE or PVC–U with frames according to EN 124 2, EN 124 3, EN 124 4 and EN 124 5.
This European Standard is not applicable in isolation but only in combination with EN 124 1.
This European Standard is not applicable to:
- rodding point covers according to EN 13598 1;
- gratings/covers as part of prefabricated drainage channels according to EN 1433;
- floor and roof gullies in buildings which are specified in EN 1253 (all parts);
- surface boxes.
- Standard38 pagesEnglish languagesale 10% offe-Library read for1 day
This standard applies to permanently fixed ladders in manholes. It specifies the performance criteria for the mechanical stability and resistance providing protection against falling.
The ladders specified in this European Standard are suitable for use in sewage, rainwater, surface water and, subject to the requirements of national regulations, potable water environments.
- Standard32 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements for prefabricated linear drainage channels for the collection and conveyance of surface water when installed within areas subject to pedestrian and/or vehicular traffic. It applies to grid units, slot units and kerb units up to a clear opening of 1000 mm.
- Standard58 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard55 pagesGerman languagesale 10% offe-Library read for1 day
This standard specifies general requirements and testing methods for steps manufactured from cast iron, steel or aluminium, for use in manholes and other underground man entry chambers as a means of access.
This standard specifies performance criteria for mechanical stability and resistance providing protection against falling. Corresponding test methods and evaluation of conformity are included.
The steps specified in this European Standard are suitable for use in sewage, surface water and, subject to the requirements of national regulations, potable water environments.
Where steps are to be used in particular corrosive environments, e.g. industrial effluents, additional protection may be required.
This standard does not apply for steps moulded in prefabricated manholes of the same material.
- Standard35 pagesEnglish languagesale 10% offe-Library read for1 day
This standard specifies test methods for gullies for buildings according to prEN 1253-1: 1997 and access covers in accordance with prEN 1253-4.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
This standard classifies gullies, gives guidance for places of installation and specifies requirements for the construction, design, performance and marking of factory made gullies for buildings, irrespective of material, for use in drainage systems operating under gravity including siphonic systems. Note: Although normally used to convey domestic waste water, industrial waste water and rainwater, gullies can convey other waste water provided there is no risk of damage to components or of injury to health. This standard does not apply to gully tops and manhole tops which are specified in EN 124.
- Standard13 pagesEnglish languagesale 10% offe-Library read for1 day